    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s OWNER'S MANUAL D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 o f 4 0 Including Installation Instruc tions And Warranty Information TO SUIT HEAT PUMP STORAGE WATER HEATER MODELS Compact: 150-08ACW-134 270-11AC3-134 340-11AC3-134 340-17ACW-134 Titan Split: 340TI ...

  • Quantum 270-11AC3-134 - page 2

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 o f 4 0 Contents Sec tio n 1: APP LIAN CE D ETA ILS ................................................................................................. 5 1a: Owner’s Details ............................................. ...

  • Quantum 270-11AC3-134 - page 3

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 o f 4 0 4c: Caution W hen Left Op erating But Unused........................................................................... 14 Sec tio n 5: SAFE TY I NFO RMA TION .................................................... ...

  • Quantum 270-11AC3-134 - page 4

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 4 o f 4 0 10b.2: Second Level: Press SE T+DOWN for 6 seconds .......................................................... 26 10b.3: Third Level: Press UP+DOWN for 6 sec onds .................................. ......... 26 1 ...

  • Quantum 270-11AC3-134 - page 5

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Section 1: APPL IANCE DETA ILS For future convenience, please fill in the following details and retain with your original invoice. 1a: Owner’s Details Surname: …………………………………… Given Name(s): ….……………………….... Address: ……………… ...

  • Quantum 270-11AC3-134 - page 6

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Sectio n 2: INTR ODUCTION Quantum Energy Technologies 2a: One Of The Worlds Most Energy Efficient Methods Of Wa ter Heating Production W e thank you for your decision to purchase a Qu antum Energy Technologies Heat Pum p Water Heater, which will reward you with many y ears of low e ...

  • Quantum 270-11AC3-134 - page 7

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s 2c: Features Of Your Quantum Wat er Heat er 1. Fully welded steel tank with class X vitr eous enam el lining for superior corrosion resistance and longer life. 2. Indirect heat transfer eliminates tank hot spots. 3. One of the most energy efficient Heat Pum p systems in the world. 4 ...

  • Quantum 270-11AC3-134 - page 8

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 8 o f 4 0 3a.2: Corrosion Protection Fittings and the Shell Surface in contact with the wa ter are to be galvanica lly comp atible. Sealants and / or Teflon plum bing tape should be used on potentially galvanically incom ...

  • Quantum 270-11AC3-134 - page 9

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 9 o f 4 0 3f: Cold Water Connection An approved isolating valve, appr oved non-return valve, line strainer (op tional but recom mended), and union mu st be fitted between the supply m ain a nd the RP ¾ / 20mm socket in t ...

  • Quantum 270-11AC3-134 - page 10

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 0 o f 4 0 3m: Electrical Connection Quantum water heaters are designed for singl e-phase 220/240V A.C supply only. A certified electrician must carry o ut all electrical work accor ding to the local supply authority reg ...

  • Quantum 270-11AC3-134 - page 11

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s 3n.1: Refrigeration Tube Siz es Quantum Model Copper Tube Siz e - Inlet Copper Tube Size - Outlet 340 TIH-134 3 / 8 Inch (9.5mm ) 5 / 8 Inch (15.9mm ) * When the evaporator is below the tank level on the Titan model use 12.7mm(1/2”) outlet tube. 3o: Caution Regarding Drilling Meta ...

  • Quantum 270-11AC3-134 - page 12

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Figure 1: Installation Diagram (Compact Systems) D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 2 o f 4 0 Orie ntat ion if multiple Com pact units are Condensation Drain Power Cord 100 m m Mi n Wal l 500 m m Min be ing ins talled . i.e. fan to face out. Wat e r Conn ...

  • Quantum 270-11AC3-134 - page 13

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Figure 2: Installation Diagram (Split Systems) D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 3 o f 4 0 Power Connect ion Wat e r Connect ions 35° 32° 100 m m Mi n 2 0 0 m m i M n Wa ll PTR Valve Front Access Tank Orientation Diagram For Split Units ...

  • Quantum 270-11AC3-134 - page 14

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Section 4: OPERAT ING INSTRUCTIONS 4a: Filling The Water Heater Open all hot water taps. Open isolating valve at th e cold-wa ter inlet and allow the water heater to fill until water flows through the system . Close each hot water tap after the ai r is expelled from its line. 4b: Wa ...

  • Quantum 270-11AC3-134 - page 15

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s 5b: Important Note Regarding PTR Valve The Pressure & Temperature relief valve should be checked for adequate perform ance or replaced at intervals not exceeding 5 years, or less in areas where there is a high incidence of water deposits. Providing there is som e discharge from ...

  • Quantum 270-11AC3-134 - page 16

    Owner’ s Manual Quantum Energy T echnologies 6d: Ser vice Ca ution – Bef ore Any Work Is Carried Out Before any electrical components are inspected the System MUST be turned off at the power switch / hot water circuit breake r. Do not touc h wiring or any electrical com ponents without supervision or training to Austra lian (or equivalent) stan ...

  • Quantum 270-11AC3-134 - page 17

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 7 o f 4 0 6f.2: Five Year Service (By Authorized Personnel Only) The five-year service should be carried out by a li censed tradesperson every five years. It is recomm ended that your local Quantum distributo r carry ou ...

  • Quantum 270-11AC3-134 - page 18

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 1 8 o f 4 0 6f.4: Flushing Of Water Tank As with other hot water heater tanks, dissolved solids in the water or scale m ay accum ulate in the bottom of the water tank form ing sludge. This is ge nerally less of a problem ...

  • Quantum 270-11AC3-134 - page 19

    Owner’ s Manua l Q u a n t u m Energy T echnologies Section 7: RECOGNITION OF ABNORM AL OPERATION 7a: Pressure & Temperatu re Relief Valve Running It is not unusual for the Pressure & Tem perature Relief valve to allow a small quantity of water to escape during the heating cycle. The am ount of di scharge will depend on hot water us age. ...

  • Quantum 270-11AC3-134 - page 20

    Owner’ s Manua l Q u a n t u m Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 0 o f 4 0 4. Replace faulty tap washers and have your plumber rectify any leaking pipe work. 5. Have any new appliances been instal led that might be using the extra power? 6. If there are no water leakages around the build ing and ...

  • Quantum 270-11AC3-134 - page 21

    Owner’s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Section 8: WARRANTY CERTIFICATE QUANTUM HOT WATER UNIT MANUFACTURE D BY QUANTUM ENERG Y TECHNOLOGIES PTY LTD Terms Of Warranty QUANTUM ENERGY TECHNOLO GIES PTY LTD (the Company ) WARRANTS “THIS QUANTUM ENERGY SYSTEM” (t he uni t) against faul ty workma nship, m ate rials and def ...

  • Quantum 270-11AC3-134 - page 22

    Owner’ s Manua l Quantum Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 2 o f 4 0 8a: Items Not Covered By Warranty □ Service calls due to: • Dirty Filters. • Blown Fuses • Incorrect Operation. • Tripped Circuit Breakers. • Main Isolator Switched Off. • Blocked Drains (Eva porator or PTR Valve). ...

  • Quantum 270-11AC3-134 - page 23

    Owner’ s Manual Q u a n t u m Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 3 o f 4 0 Section 9: SPECIFICATIONS Tanks are Dual Entry, Fully W elded w ith Class X Vitreous Ena m el lining. Figure 3: Specifications & Dimens ions A B 540mm Diameter 150ACW-134 A B 540mm Di ameter 150ACW-134 Dimensions(mm) Mo ...

  • Quantum 270-11AC3-134 - page 24

    Owner’s Manual Quantum Energy T echnologies Figure 4: Split Fin Coil Evaporator – 340 TIH-134 D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 4 o f 4 0 635 400 500 3 / 8 ” Discharge Line 5 / 8 ” Suction Line 660 Air Flow Refrigeration Connect ion Power Cable 100 1 1 0 5 0 4 0 150 A qualified ref rigeration technician m ust i ...

  • Quantum 270-11AC3-134 - page 25

    Owner’ s Manua l Quantum Energy T echnologies Section 10: OPERATION & ADJUSTMENT OF TH E DIGITAL CONTROLLER Caution: Alteration of the Digital Controllers progr amm ing & settings without authorisation fro m Quantum Energy T echnologies will void your warranty . This section is provided ONL Y for qualified refrigeration technicians to ass ...

  • Quantum 270-11AC3-134 - page 26

    Owner’ s Manua l Quantum Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 6 o f 4 0 10b.1: First Level: Press SET + UP for 6 Seconds t10 Compressor start time delay; 1 to 30 m in adjustable. Factory setting 10 min. p10 Interval for compressor start after stop; 3 to 30 min adjustable. Fa ctory setting 10 min. d1 ...

  • Quantum 270-11AC3-134 - page 27

    Owner’ s Manua l Quantum Energy T echnologies D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 7 o f 4 0 10d: De-Icing Only if the temperature, measured by the evaporator sensor , is below 0 ℃ will the de-icing function operate. When the compressor has been operating for 45 min (1 st Level F45) and the evaporator tem perature is ...

  • Quantum 270-11AC3-134 - page 28

    Owner’s Manual Quantum Energy T echnologies Figure 5: Layout Of Digital Controller Programming Buttons D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 2 8 o f 4 0 LCD Display Up But ton S e t B u t t o n D o w n B u t t o n ...

  • Quantum 270-11AC3-134 - page 29

    ...

  • Quantum 270-11AC3-134 - page 30

    ...

  • Quantum 270-11AC3-134 - page 31

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s Appendix A: TROUBLE SHOOTING GUIDE ON QUANTUM WATER HEATERS Models covered in this guide : 800 W att. Compact Air Sourced Dom estic Hot W ater Heater (0.8kW compressor m odels) 1100 W att. Compact Air Sourced Dom estic Hot W ater Heater (1.1kW compressor m odels) 1700 W att . Titan ...

  • Quantum 270-11AC3-134 - page 32

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 2 o f 40 A.2: Thermal Cut Out Trips Off Repeatedly Probable Cause Test / Observation Action 1. Low refrigerant charge. Check refrigerant ch arge. Test for possible leak in the refrigeration circuit. Top up refrigerant ...

  • Quantum 270-11AC3-134 - page 33

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 3 o f 40 A. 3: No Hot Water; Compressor Running Probable Cause Test / Observation Action 1. Tank water drawn off - unit only recently started. W ait until water is heated. If water is not heated in the expected tim e, ...

  • Quantum 270-11AC3-134 - page 34

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s A.5: Testing Undercharge Or Overcharge Of Refrigerant Unlike normal refrigerating or air condition ing systems, the QUANTUM heat pum p operates under a very wide range of evaporating and condensing temp eratures. To identify undercharge or overcharge of refrigeran t gas in the syst ...

  • Quantum 270-11AC3-134 - page 35

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 5 o f 40 A.8: Signs Of Correct Charge During normal operation with the correct am o unt of refrigerant gas, the sight glass should show clear liquid. A very few small bubbles m a y be present when the system is started ...

  • Quantum 270-11AC3-134 - page 36

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 6 o f 40 A.11: Technical Data Fo r Service Person nel – SIAM Compressors – R134a Parameters 150-08ACW-134 270 & 340-11AC3-134 340TIH-134 340-17ACW-134 Superheat setting 1.5Turn(F.Close) 3.5 Turns(7 Turns ) F..O ...

  • Quantum 270-11AC3-134 - page 37

    Owner’ s Manual Q u a n t u m E n e r g y T e c h n o l o g i e s WARRANTY CARD Warranty Registered (Office Use Only) □ P r o d u c t M o d e l : S e r i a l N u m b e r : D a t e M a n u f a c t u r e d : Installation Details I n s t a l l T y p e □ New □ Repla ce Date Installed Old System (T ype) T a n k P o s i t i o n □ External □ I ...

  • Quantum 270-11AC3-134 - page 38

    Owner’ Manual Quantum Energy T echnologies BLANK PAGE D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 8 o f 4 0 ...

  • Quantum 270-11AC3-134 - page 39

    Owner’ Manual Quantum Energy T echnologies NOTES (Own er’s Use) D o c u m e n t n u m b e r : Q D C 0 0 3 0 P D - 1 1 P a g e 3 9 o f 4 0 ...

  • Quantum 270-11AC3-134 - page 40

    MANUFACTURED BY QUANTUM ENERGY TE CHNOLOGIES PTY LTD 56-60 Bourke Road Alexandria NSW 2015 Phone: (02) 4953 9888 Fax (02) 4953 9887 A.B.N: 88 095 959 327 NOTE: Every care has been taken to ensure th e accuracy in preparing this publication. No liability can be accepted for any consequences, which m ay arise as a re sult of its application. Quantum: ...

Manufacturer Quantum Category Water Heater

Documents that we receive from a manufacturer of a Quantum 270-11AC3-134 can be divided into several groups. They are, among others:
- Quantum technical drawings
- 270-11AC3-134 manuals
- Quantum product data sheets
- information booklets
- or energy labels Quantum 270-11AC3-134
All of them are important, but the most important information from the point of view of use of the device are in the user manual Quantum 270-11AC3-134.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Quantum 270-11AC3-134, service manual, brief instructions and user manuals Quantum 270-11AC3-134. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Quantum 270-11AC3-134.

A complete manual for the device Quantum 270-11AC3-134, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Quantum 270-11AC3-134 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Quantum 270-11AC3-134.

A complete Quantum manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Quantum 270-11AC3-134 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Quantum 270-11AC3-134, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Quantum 270-11AC3-134, that we can find in the current document
3. Tips how to use the basic functions of the device Quantum 270-11AC3-134 - which should help us in our first steps of using Quantum 270-11AC3-134
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Quantum 270-11AC3-134
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Quantum 270-11AC3-134 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Quantum 270-11AC3-134?

Use the form below

If you did not solve your problem by using a manual Quantum 270-11AC3-134, ask a question using the form below. If a user had a similar problem with Quantum 270-11AC3-134 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)