  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 1

    IBM E Rs e rv e r Cisco Systems Inte lligent Gigabi t Ether net Switch Module f or the IBM E ser v er BladeCenter System Message Guide Cisco IOS R eleas e 12.1 (14)A Y ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 2

    Note: Bef ore using this inf or mation and the pro duc t it su ppo rts, read th e g enera l i nf or mation i n Ap pen dix B .“Getting hel p and t echnica l assist ance” and Append ix C .“Notices”. 12 1 First Edition (J une 2004) 2 © Copyright In ternationa l Business Machines Corpo ration 2004. All rights re served. US Government Users R e ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 3

    © Copyright IBM Corp. 2004 1 Contents Prefac e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 A udienc e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Pur pose . . . . . . . . . . . . . . . . . . . . ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 4

    2 BookTitle change in s pecial and import ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 5

    © Copyright IBM Corp. 2004 3 Preface A u dience This g uide is for the netwo rking professional m anaging th e Cisco S ystems Int elligent Gigabi t Ether net Sw itch Module, hereafter referred to as the switch . Before using this guide, you should hav e ex per ience wor king with the switch and it s sof tware f eatures. Purpos e This g uide desc r ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 6

    4 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM E server BladeCenter System Mes sage Guide install ing, conf iguring , or upgradin g the switch, refer to the re lease notes for the late st inf or mat ion. • Cisco S ystems Inte lligent Gi gabit Ethe rn et Switch Module for the IBM eS er ver BladeCen ter System Command Refere ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 7

    Preface 5 — How to inst all the ma nagement m odule — How to configur e and use th e manag ement modu le • BladeCen ter HS20 I nstallati on and User ’ s Gu ide (for each blade se rver typ e) These doc uments are i n PDF on the IBM Blad eCenter Docu mentation C D . Each provides g eneral inform ation abou t a blade ser ver , i ncludin g: — ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 8

    6 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM E server BladeCenter System Mes sage Guide ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 9

    © Copyright IBM Corp. 2004 7 Chapter 1. System Message Over vie w This g uide desc ribes the switch-speci fic syste m messa ges. During operation, t he system software sen ds these mes sages t o the consol e (and, op tionally , to a loggi ng ser ver on another system) . Not all s ystem mess ages in dicate proble ms with your system . Some mes sage ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 10

    8 Cisco Systems Intelligent Gigabit Ethernet Switch Module for the IBM E server BladeCenter System Mes sage Guide • SEVERITY is a si ngle-digi t code from 0 to 7 that r eflects the sev erity of the conditi on. The lower the numb er , the more se riou s the si tuation. Ta b l e 2 lists t he message se verity levels. • MNEMONIC is a code th at un ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 11

    Chapter 1. System Message O verview 9 This is a sample s ystem messa ge: %EC-5-UNBUNDLE:Interface Gi0/2 left the port-channel Po2 The messa ges in Ch apter 2 “Me ssage and Re cov er y Procedur es, ” are de scrib ed in alphabeti cal order by facility cod e with the m ost sev ere (lowest number) errors descr ibed fir st. Err or Messa ge T racebac ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 12

    10 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 13

    © Copyright IBM Corp. 2004 11 Chapter 2. Message a nd Recovery Pr ocedures This cha pter desc ribes the switch system messages in alp habetical o rder by f acility . Within e ach facility , the me ssages are listed b y sev erity le vels 0 to 7; 0 is the highest sev erity le v el, and 7 is the l owest se v er ity lev el. Each m essage i s f ollowed ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 14

    12 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide CIGESM Messages This section contains the Cisco Sy stems Intelligent Gigabit Ethernet Switch Module (CIGESM) messages. PLA TFORM_CIGESM-2-O VER_THERMAL_THRESH2: Th e Switch Mod ule has excee ded its sec ond thermal thresho ld. Explan ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 15

    Chapter 2. Message and Recovery Pr ocedures 13 PLA TF ORM_CIGESM-5-DISABLE_EXTERN: Re quest fr om Ma nagement M odule: disa ble all e x ternal ethernet ports gi0/ 17 - 20 . Explanation This message means that the switch received a request from the management module to shut down ports 17 to 20. Response No action is required. PLA TFORM_CIGESM-5-DISA ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 16

    14 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PLA T FORM_CIGESM-5-UNDR_THERMAL_T HRESH1: The Switch Module has reco vered fr om fir st thermal thresho ld. Explanation This message means that the s witch tem perature no longer e xceeds the first ther mal threshold of 167°F (75° ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 17

    Chapter 2. Message and Recovery Pr ocedures 15 CMP Messages This section contains the Cluster Membership Protocol (CMP) messages. CMP-5-ADD: The Devic e is added to the cl uster (Cluster Name: [chars] , CMDR IP Ad dress [inet] ). Explanation This message means that the de vice is added to the cluster . [ chars] is the cluster name, and [inet] is th ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 18

    16 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide DO T1X Messages This section contains the 802.1X authorization messages. DO T1X_MOD-3 -NULLPTR: Unexpecte d null poi nter in [chars ] at [dec] . Explanation This message means that an internal software error occurred. [chars] is the ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 19

    Chapter 2. Message and Recovery Pr ocedures 17 DTP Messages This section contains the Dynamic T runking Protocol (DTP) messages. DTP-4-MEM_ UNA V AIL: Memory was not a v ailable to perf orm the trunk negotiatio n action. Explanation This message means that the system is unab le to negotiate trunks because of a lack of memor y . Response Reduce othe ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 20

    18 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide DTP-5-TR UNKPOR T ON: P ort [chars] has becom e [chars] trunk. Explanation This message means that the interf ace changed from an access to a tr unk. The first [chars] is the interf ace , and the second [chars] is the encapsulation. ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 21

    Chapter 2. Message and Recovery Pr ocedures 19 EC-5-CANNO T_BUNDLE_ QOS: Remo ved [char s] fr om port channel because a Qo S policy canno t be supported acro ss m ultiple DFC c ard s. Explanation This message means the specified por t cannot join the por t channel because the QoS policy attached to the por t channel cannot suppor t the multiple Dis ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 22

    20 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide EC-5-L3DONTBNDL1: [chars ] suspended : P AgP not ena bled on the remote p ort. Explanation This message means that P or t Aggregation Protocol (P AgP) is enabled on a La y er 3 interf ace , but the r emote por t does not hav e P AgP ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 23

    Chapter 2. Message and Recovery Pr ocedures 21 EC-5-NOP A G P: Inv alid EC mode. P AgP not enabled. Explanation This message means that P A gP is not included in the IOS image and that the EtherChannel mode cannot be set to desirab le or auto . Response Obtain an image wi th P A gP included, or set the mode to on b y using the c hannel- gr oup chan ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 24

    22 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide ETHCNTR-3-LOO P_B A CK_DETECTED:, Lo op-bac k detect ed on [chars ] . The port is f or ced to linkdo w n. Explanation This message means that t he loop-bac k condi tion might be caused by a balun cable being accidentally connected to ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 25

    Chapter 2. Message and Recovery Pr ocedures 23 PLA TFORM_CA T2950-3-MEM_ COPY_F AILURE: In v alid cop y [dec ] fo r t a bl e [chars] . Explanation This message means that there was an attempt to read or write an inv alid copy of the s witch internal memor y . [dec] is the inv alid copy number f or the table , and [chars] is the name of the ASIC mem ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 26

    24 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PLA TFORM_ CA T2950-3-MEM_WRITE_F AILURE: Write memo ry failed for memory [c hars] at inde x [dec] . Explanation This message means that an attempt to write to a location in the internal chip memor y f ailed, which might occur becaus ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 27

    Chapter 2. Message and Recovery Pr ocedures 25 PLA TFORM_CA T2950-3-REG_READ _F AILUR E: Register re ad faile d for [chars] in [chars] Explanation This message means that t he register r ead f ailed for register [char s] in [chars ] . An at temp t to read a v alid location in the internal chip regi ster f ailed. This could be due to a hardwar e def ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 28

    26 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PLA TFORM_CA T29 50-3-SYSTEM_I NFO_F A ILURE: The bo ard inf ormation co uld not be read co rr ectly , initializ ation failed. Explanation This message means that, during switch driv er initialization, there was a f ailure to read th ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 29

    Chapter 2. Message and Recovery Pr ocedures 27 PM-3-INTERNALERROR: P ort Ma nager Internal Software Error [cha rs] : [chars] : [dec] : [c hars] Explanation This message means an internal software error occurred in the IOS P or t Manager . The arguments prov ide details about the f ailure that technical suppor t can analyze. Response Find out mo re ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 30

    28 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PM-4-B A D_COOKIE: [char s ] was dete cted. Explanation This message means that the por t manager detected an in v alid request. [chars] is the inv al id request. Response Find out mo re about the error by usin g the sho w tech- supp ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 31

    Chapter 2. Message and Recovery Pr ocedures 29 PM-4-B A D_VLAN_ID: An in v alid vlan id ( [dec ] ) was detecte d. Explanation This message means that the por t manager detected an inva lid request. [dec] is the V LAN ID . Response Find out mo re about the error by usin g the sho w tech-s upp ort privil eged EXEC co mmand and by cop ying the error m ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 32

    30 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide PM-4-INT_F AILUP: [chars] fa iled to come up. No internal VLAN av ailab le. Explanation This message means that the port manager failed to allocate an inter nal VLAN, and the interf ace cannot come up. [chars] is the interf ace name. ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 33

    Chapter 2. Message and Recovery Pr ocedures 31 PM-4-T OO_MANY_APP: Applic ation ' [c hars] ' exceed ed r egist rat ion limit . Explanation This message means that the por t manager detected an in v alid request. [chars] is the application. Response Find out mo re about the error by usin g the sho w tech-s upp ort privil eged EXEC co mmand ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 34

    32 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SP AN-3-UNKN_ERR: An internal error oc curred during a SP AN operation. Explanation This message means that SP AN detected an error in its internal operation. Response The error might be transient. T r y the SP AN operation again. If ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 35

    Chapter 2. Message and Recovery Pr ocedures 33 SP ANTREE-2-CHNL_MISCFG: Detec ted loop due to ether c hannel m isconfiguratio n of [chars ] [chars] Explanation This message means that a loop that caused the misconfiguration of a channel group has been detected. An e xample of such a misconfigur ation would be when the por ts on one side of the Ethe ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 36

    34 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SP ANTREE-2-PVSTSIM_F AIL: Superior PVST BPDU rece ived on VL AN [dec] port [ch ars] , c laiming r oot [dec] : [enet] . In voking roo t guar d to bloc k the port. Explanation This message means that when a per- VLAN spanning-tree plu ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 37

    Chapter 2. Message and Recovery Pr ocedures 35 SP ANTREE-2-ROO TGU ARD_BLOCK: Root guar d bloc king port [chars] on [chars] . Explanation This message means that on the listed interf ace a BPDU was receiv ed that adv er tises a superior spanning-tree root bridge (lower bridge ID , low e r path cost, and so f or th) than that in use. The interf ace ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 38

    36 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide This is performed b y the STP subsystem at system initialization because the maximum number of ports on a par ticular platform does not c hange . The first [dec] is the n umber of bits f or the por t number , and the second and third ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 39

    Chapter 2. Message and Recovery Pr ocedures 37 SP ANTREE-7-BLOCK-PORT -TYPE: Blocking [chars ] on [ch ars] . Incon sistent port type. Explanation This message means that the listed interf ac e is being held in the spanning-tree bloc king state until the port-type inconsistency is reso lv ed. The first [chars] is the interf a ce, and the second [cha ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 40

    38 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SP ANTREE_F AST M essa ges This section contains the spanni ng-tree f ast-conv ergence message. SP ANTREE_F AST -7-PORT_FWD_ UPLINK: [chars] [chars ] mo ved to Forwar ding (UplinkF ast). Explanation This message means that the listed ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 41

    Chapter 2. Message and Recovery Pr ocedures 39 SW_VLAN Messages This section contains the VLAN manager messages. The VLAN manager receiv es inf or mation from the VTP and enab les the proper VLAN membership on all interf aces through the port manager . SW_VLAN-3-VLAN_PM_NO TIFICA TION_F AILURE: VLAN Manager synchr onization failure with P ort Manag ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 42

    40 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SW_VLAN-4-B AD_ VLAN_CONFIGURA TION_FILE: VLAN configuration file con tained incorrect verification word: [hex] . Explanation This message means that the VLAN configuration file read b y the VLAN manager did not begin with the correc ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 43

    Chapter 2. Message and Recovery Pr ocedures 41 SW_VLAN-4-EXT_VLAN_INTERNAL_ERR OR : Extended VLAN ma nager received an internal error [dec] fr om [chars] : [chars] . Explanation This message means that an une xpected error code w as receiv ed by the VLAN manager from the e xtended-range VLAN configuration software . [dec] is the er ror code. The fi ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 44

    42 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide SW_VLAN-4-ST ARTUP_EX T_VLAN_CONFIG_FILE_F AILED: Failed to configure e x tended range VLAN fr om startup-config. Err or [chars] . Explanation This message means that the VLAN softw are f ailed to use an e xtended-range VLAN configur ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 45

    Chapter 2. Message and Recovery Pr ocedures 43 SW_VLAN-4-VTP_USER_NO TIFICA TION: VTP protocol u ser notificatio n: [char s] . Explanation This message means that the VTP code enc ountered an un usual di agnostic situation. [chars] is a descr iption of the situation. Response Find out mo re about the error by usin g the sho w tech-s upp ort privil ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 46

    44 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide UDLD-3-UDLD_INTERNAL_IF_ERR OR: UDLD internal err or , interface [cha rs] : [chars] . Explanation This message means that a softw are check f ailed dur ing UDLD processing. The first [chars] is the interf ace, and the second [chars] ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 47

    Chapter 2. Message and Recovery Pr ocedures 45 UF AST_MCAST_SW -4-MEM_NO T_A V AILABLE: No memory is a vail able for tr ansmitting UplinkF ast packets o n Vlan [dec ] . Explanation This message means that no memor y is availab le f or sending UplinkF ast pac kets on VLAN [dec] . [dec] is the VLAN number . Response Reduce other system activity to re ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 48

    46 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 49

    © Copyright IBM Corp. 2004 47 Appendix A. Secu rity and QoS Configuration Messages This appe ndix des cribes the switch error m essages f or confi guring network secur ity with acces s contro l lists (ACLs) and for configur ing quali ty of ser vice ( QoS). In Ta b l e 4 , Access C ontrol P arameters ( A CPs) are r ef erred to as masks. F or more i ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 50

    48 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide %Error:System Defined ACEs of TCP/UDP and IP cannot exist together in access-group within a class-map. Check class-map :[class-map name] This error mess age means that a co mbination of Lay er 3 syst em-defined a ccess co ntrol ent r ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 51

    Appendix A. Security and QoS Configuration Messages 49 %Error:Invalid rule This error messa ge means tha t the hardware had a p roblem programming t he resource. Re-ente r the comma nd that you had e ntered before receiv ing the er ror message. If the mes sage rec urs, find out more abou t the error by using the show tech-sup port p rivil eged EXE ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 52

    50 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide %Error:No free masks available This error mess age means that there ar e no fre e masks av ailable f or the user . Y ou mus t use one of the user-defi ned mask s that is al ready config ured. As an alter native, you can free up one o ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 53

    Appendix A. Security and QoS Configuration Messages 51 %Error:FAILURE to reinsert old ACL, errcode=XX This error mess age means that a har dware f ailur e has occurr ed. Dele te the acces s group , and re-en ter the c ommand that you had enter ed before rece iving the error me ssage. If the mes sage rec urs, find out more abou t the error by using ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 54

    52 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide %Error:Policer Configuration Incorrect for this interface. Check the policer rate in policy-map :[policy-map name], class-map :[class-map name]. Please choose either [lower rate] or [upper rate] (bits per second) as the policer rate ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 55

    © Copyright IBM Corp. 2004 53 Appendix B. Gett ing help and technical ass istance If you need hel p , ser vice, or techn ical as sistance o r just want mo re informati on about IBM prod ucts, you will find a wi de variety of so urces available from I BM to assist you. This a ppendix con tains infor mation ab out where t o go for additional inf orm ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 56

    54 BookTitle change in special and import Software service and suppor t Through IB M Suppor t Lin e, y ou can g et telephon e assistan ce, f or a fee , with usa ge, configura tion, and s oftware problems wit h BladeCe nter and x Serie s ser vers, IntelliS tation workstati ons, and appli ances. For inf orm ation abou t which pr oducts ar e suppor te ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 57

    © Copyright IBM Corp. 2004 55 Appendix C. N otices This infor matio n was de veloped for products a nd ser vice s offered in the U.S .A. IBM may not offer the produc ts, ser vices, or features dis cussed in this docum ent in other co untri es. Consult your lo cal IBM re presenta tive f or informat ion on the p roducts and ser v ices curre ntly ava ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 58

    56 BookTitle change in special and import T radema rks The f oll owing ter ms are trademar ks of Inter nationa l Business Ma chines Cor poration in the United States, other countri es, or both: Cisco, Cisco IOS, Cisco Sy stems, the Cis co Systems logo , Cataly st, EtherC hannel, IOS, IP/TV , Pac ket, and SwitchPr obe are re gistered tradem arks o f ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 59

    57 Index Numerics 802.1X aut henticati on message s 16 see DOT 1X messag es A abbrevi ations char , var iabl e fi eld 8 chars, variab le field 8 dec, vari able field 8 enet, var iable field 8 hex, vari able field 8 inet, var iable fiel d 8 access contro l list m essages See AC L messages ACL me ssages 47 applica tion-sp ecific inte grated c ircuit ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 60

    58 Cisco Systems Intelligent Gigabit Ethernet Switch M odule for the IBM E server BladeCenter S ystem Mes sage Guide Ethe rne t con tro ller 21 hardwar e MAC addres s table mana ger 22 LACP 18 MAC addr ess table m anager 22 PAgP 18 per-VLAN sp anni ng -tre e 38 PLATFORM_CA TALYST2950 26 port mana ger 26 port secur ity 31 QoS 47 secu rity 47 SPAN 31 ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 61

    ...

  • Cisco Systems Intelligent Gigabit Ethernet Switch Module - page 62

    IBM@ P art Number : 2 5K8409 ...

Manufacturer Cisco Systems Category Switch

Documents that we receive from a manufacturer of a Cisco Systems Intelligent Gigabit Ethernet Switch Module can be divided into several groups. They are, among others:
- Cisco Systems technical drawings
- Intelligent Gigabit Ethernet Switch Module manuals
- Cisco Systems product data sheets
- information booklets
- or energy labels Cisco Systems Intelligent Gigabit Ethernet Switch Module
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cisco Systems Intelligent Gigabit Ethernet Switch Module.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cisco Systems Intelligent Gigabit Ethernet Switch Module, service manual, brief instructions and user manuals Cisco Systems Intelligent Gigabit Ethernet Switch Module. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cisco Systems Intelligent Gigabit Ethernet Switch Module.

A complete manual for the device Cisco Systems Intelligent Gigabit Ethernet Switch Module, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cisco Systems Intelligent Gigabit Ethernet Switch Module by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cisco Systems Intelligent Gigabit Ethernet Switch Module.

A complete Cisco Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cisco Systems Intelligent Gigabit Ethernet Switch Module - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cisco Systems Intelligent Gigabit Ethernet Switch Module, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cisco Systems Intelligent Gigabit Ethernet Switch Module, that we can find in the current document
3. Tips how to use the basic functions of the device Cisco Systems Intelligent Gigabit Ethernet Switch Module - which should help us in our first steps of using Cisco Systems Intelligent Gigabit Ethernet Switch Module
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cisco Systems Intelligent Gigabit Ethernet Switch Module
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cisco Systems Intelligent Gigabit Ethernet Switch Module in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cisco Systems Intelligent Gigabit Ethernet Switch Module?

Use the form below

If you did not solve your problem by using a manual Cisco Systems Intelligent Gigabit Ethernet Switch Module, ask a question using the form below. If a user had a similar problem with Cisco Systems Intelligent Gigabit Ethernet Switch Module it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)