Manual Intel SR1500AL

180 pages 3.16 mb
Download

Go to site of 180

Summary
  • Intel SR1500AL - page 1

    Intel ® Ser ver System SR1500AL User’ s Guide A Guide f or T echnical ly Qual ified Assemble rs of In tel® Identifie d Subassemblie s/ Produ cts Intel Ord er Number D3 1970-002 ...

  • Intel SR1500AL - page 2

    ii Intel ® Server System SR1500AL User’s Guide Disclaimer Information in this document is provided in connection wit h Intel® products. No license, e xpress or implied, b y estoppel or otherwise, to any intellectual proper ty rights is granted by this document. E xcept as provided in Intel's T erm s and Conditions of Sale f or such product ...

  • Intel SR1500AL - page 3

    Intel ® Server System SR1500AL User’s Guide iii ...

  • Intel SR1500AL - page 4

    iv Intel ® Server System SR1500AL User’s Guide § ...

  • Intel SR1500AL - page 5

    Preface About this Manu al Thank you for purchasing and using the Intel ® Server System SR1500AL. This manual is written for system technici ans who are responsible for troubleshooting, upgrading, and repairing this server sy stem. This document provides reference information, feature information, and step by step instructions on how to add and re ...

  • Intel SR1500AL - page 6

    vi Intel ® Server System SR1500AL User’s Guide There are two versions of this server system: the Intel ® Server System SR1500ALSAS (SAS/SA T A version) and the Intel ® Server System SR1500AL (SA T A only version). The contents of each server system are listed below . Intel ® Server System SR1500ALSAS Contents Yo u r I n t e l ® Server System ...

  • Intel SR1500AL - page 7

    Intel ® Server System SR1500AL User’s Guide vii Intel ® Server System SR1500AL Contents Y our Intel ® Server System SR1500AL sh ips with the following items: • Intel ® Server Board S5000P AL, installed in the server system • One 600 W power sup ply module, installed in the server system • A box of hardware components, referre d to below ...

  • Intel SR1500AL - page 8

    viii Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 9

    Safety Inf ormation Impor tant Safety Instructions Read all caution and safety statements in th is docu ment before performing any of the instructions. See also Intel Server Boards an d Server Chassis Safety Information on the Intel ® Server Deployment T oolkit 2.0 CD and/o r at http://support.intel.com/support/ motherboards/server/sb/cs-010770.ht ...

  • Intel SR1500AL - page 10

    x Intel ® Server System SR1500AL User’s Guide 重要安全指导 在执行任何指令之前, 请阅读本文档中的 所有注意事项及安全声明 。 和/或 http://su pport.inte l.com/support /motherboard s/server /sb/CS-010770.h tm 上的 Intel Server Boards and Serv er Chassis Safe ty Information(《Inte l 服务器主板与服务? ...

  • Intel SR1500AL - page 11

    Intel ® Server System SR1500AL User’s Guide xi Wa r n i n g s Heed safety instructions: Before working with yo ur se rver product, whether yo u are using this gui de or any other resource as a re ference, pay close attention t o the safety instructions. Y ou must adhere to the ass embly instructions in this guide to ensure and maintain complianc ...

  • Intel SR1500AL - page 12

    xii Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 13

    Intel ® Server System SR1500AL User’s Guide xiii T able of Contents Preface .............. ................. ................................ .............. ............... .............. ............. .. v About this Manual ................................................................................. ................................. v Manu ...

  • Intel SR1500AL - page 14

    xiv Intel ® Server System SR1500AL User’s Guide Removing the Front Bezel ......................................................................... .................. 25 Installing the Front Bezel ........................................................................... .................. 26 Removing and Installing the System Cover ............ ...

  • Intel SR1500AL - page 15

    Intel ® Server System SR1500AL User’s Guide xv Installing the Server Board ...... ..................................................... ............................... 62 Removing the Server Board .............. ..................................................... ..................... 63 Replacing the Backup Battery ........................... ...

  • Intel SR1500AL - page 16

    xvi Intel ® Server System SR1500AL User’s Guide Problems with Newly Installed Ap plication Software ................................................... 92 Problems with Application Software t hat Ran Correctly Earlier .................................. 92 Devices are not Recognized under Device Manager (Microsof t* Windows* Operating System) ... ...

  • Intel SR1500AL - page 17

    Intel ® Server System SR1500AL User’s Guide xvii English ............................................. ..................................................... ..................... ........ 135 Server Safety Information ....................................................................... ................... 135 Safety Warnings and Cautions .... ...

  • Intel SR1500AL - page 18

    xviii Intel ® Server System SR1500AL User’s Guide Advertencias sobre el montaje en bastidor ............................................... ................ 155 Descarga electrostática (ESD) .................................................................................. 155 Otros riesgos ...................................................... ...

  • Intel SR1500AL - page 19

    Intel ® Server System SR1500AL User’s Guide xix List of Figures Figure 1. Intel ® Integrated Server System SR1500AL .............................. ................................ 3 Figure 2. ChassisComponents ....................................................... ........................................... 6 Figure 3. Server Board Connector a ...

  • Intel SR1500AL - page 20

    xx Intel ® Server System SR1500AL User’s Guide Figure 42. I Installing a Full Height Add-In Card ..................................................................... 52 Figure 43. Removing a Full Height Add-In Card .................................................... ................. 53 Figure 44. Installing the I/O Expansion Mo dule to the Se ...

  • Intel SR1500AL - page 21

    Intel ® Server System SR1500AL User’s Guide xxi List of T ables Table 1. Server System Refe rences ............................................. ............................................ 1 Table 2. Intel ® Server System SR1500AL Feature Summary ................................................... 4 Table 3. NIC LED Descriptions .............. ...

  • Intel SR1500AL - page 22

    xxii Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 23

    1 Ser ver System References If you need more information about this pr oduct or information about the accessories that can be used with this server ch assis, use the following resources. T able 1. Server System References For this information or software Use this Document or Software F or in-depth technical inf or mation about the server system, in ...

  • Intel SR1500AL - page 24

    2 Intel ® Server System SR1500AL User’s Guide Hardware (peripheral boards, adapter cards) and operating systems that hav e been tested with this product T ested HardwareOperating Systems List F ound at: http://suppor t.intel.com/suppor t/m otherboards/ser ver/S5000P AL/ T o make sure y our system f alls within the allowed power b udget P o wer B ...

  • Intel SR1500AL - page 25

    2 Ser ver System Features This chapter briefly describes the main feat ures of the server system. This c hapter provides illustrations of the pro duct, a list of the server sy stem features, and diagrams showing the location of import ant compon en ts and co nn ections on the server sy stem. Figure 1. Intel ® Integrated Server System SR150 0AL TP0 ...

  • Intel SR1500AL - page 26

    4 Intel ® Server System SR1500AL User’s Guide Ta b l e 2 summarizes the features of the server system. T able 2. Intel ® Server System SR1500AL Feature Summary Feature Description Dimensions • 1.7 03 inches (43.25 mm) high • 16.930 inches (430 mm) wide • 27.25 inches (692 mm) deep • 31 pounds (14.1 kg) - max chassis weight Ser ver Board ...

  • Intel SR1500AL - page 27

    Intel ® Server System SR1500AL User’s Guide 5 Hard Drive Controller Options • Three ESB2 3Gb/s SA T A por ts (Note: 6 SA T A connectors are on the ser ver board; only 3 SA T A connectors are used in the system) • Up to three SAS drives are suppor ted (SR1500ALSAS only) • Intel ® Embedd ed Ser ver RAID T e chnology II with SW RAID le vels ...

  • Intel SR1500AL - page 28

    6 Intel ® Server System SR1500AL User’s Guide Chassis Component Identification This section helps you identify th e components of your server system. If you are near the system, you can also use the Quick Reference Label provided on the inside of the chassis cover to assist in id entifying components. Internal Components Figure 2. ChassisCompone ...

  • Intel SR1500AL - page 29

    Intel ® Server System SR1500AL User’s Guide 7 Server Board Connector and Component Locations Figure 3. Server Boar d Connector and Component Locations TP02071 M N O L J K V U S T R W Q P PP MM LL KK II HH GG FF EE DD CC BB AA Z Y X B A E D F H G C I NN OO QQ JJ A. BIOS Bank Select Jumper B. Intel ® 6321ESB IO Controller Hub C. I/O Expansion Mod ...

  • Intel SR1500AL - page 30

    8 Intel ® Server System SR1500AL User’s Guide Configuration J umper s Figure 4. BIOS Select J umper Jumper Name Jumper Purpose BIOS Select If pins 1-2 are jumpered, the BIOS in the lower bank will be selected on the next reset. These pins should be jumpered on 2-3 for normal operation. TP02087 3 BIOS Select 1-2: Force Lower Bank 2-3: Normal Oper ...

  • Intel SR1500AL - page 31

    Intel ® Server System SR1500AL User’s Guide 9 Figure 5. Reco very Jumper s Jumper Name Jumper Purpose CMOS Clear If pins 2-3 are j umpered, the CMOS settings will be cleared on the next reset. These pins should be jumpered on 1-2 for normal operation. P ass word Clear If pins 2-3 are j umpered, administrator and u ser passw ords will be cleared ...

  • Intel SR1500AL - page 32

    10 Intel ® Server System SR1500AL User’s Guide Intel ® Light Guided Diagnostics The server board contains diagnostic LEDs to help you identify failed and failing components, and to help you identify the ser ver from among several servers. Except for the ID LED, the status LED, and the 5V stan dby LED, the LEDs turn on (amber) only if a failure ...

  • Intel SR1500AL - page 33

    Intel ® Server System SR1500AL User’s Guide 11 Bac k P anel Connectors Figure 7. Bac k P anel Connector s The NIC LEDs at the right and left of eac h NIC provide the following information. A. Mouse B. K eyboard C. Serial P or t B (RJ45) D . NIC 1 (10/100/10 00 Mb) E. NIC 2 (10/100/1000 Mb) F . Video G. USB P or t 6 H. USB P or t 5 T able 3. NIC ...

  • Intel SR1500AL - page 34

    12 Intel ® Server System SR1500AL User’s Guide SAS/SA T A Backplanes The system can support either an active SAS (Product Code - ASR1500SASBP) or a passive SAS/SA T A backplane (Product Code - ASR1500P ASBP). The backplanes provide the platform support for peripheral drives and hot-swap SAS or SA T A hard drives. T o eliminate several cables, th ...

  • Intel SR1500AL - page 35

    Intel ® Server System SR1500AL User’s Guide 13 Figure 9. P assive Bac kplane Components RAID Suppor t The Intel ® Serve r System SR1500AL provides an embedde d SA T A controller that supports both 1.5 and 3. 0 Gbps data transfer rates. The Intel ® Server System SR1500ALSAS provid es SAS and SA T A support. Bo th systems can be configured fo r ...

  • Intel SR1500AL - page 36

    14 Intel ® Server System SR1500AL User’s Guide Fr ont of Server System Standar d Contr ol P anel The diagram below shows the features availabl e on the standard control panel. Another option is the Intel ® Local Control Panel, which is discussed next. Callout Feature Function A. B. NIC 2 Activity LED NIC 1 Activity LED Continuous green light in ...

  • Intel SR1500AL - page 37

    Intel ® Server System SR1500AL User’s Guide 15 Figure 10. Standar d Contro l P anel Intel ® Local Contr ol P anel The diagram below shows the features available on the Intel ® Local Control Panel. J . USB 2.0 P or t Allows y ou to attach a USB component to the front of the chassis. K. NMI Button Puts the ser ver in a halt-state for diagnostic ...

  • Intel SR1500AL - page 38

    16 Intel ® Server System SR1500AL User’s Guide Figure 11. Intel ® Local Contr ol P anel Bezels The optional front bezels provide a snap-on design that allows for maximum airflow through the server chassis. T wo bezels are available. One fits a system that has the standard control panel installed. The other is used for a chassis with the other I ...

  • Intel SR1500AL - page 39

    Intel ® Server System SR1500AL User’s Guide 17 Rear of Server System Figure 12. Server System Bac k A. PS2 mouse connector H. USB 2 connector B. PCI card brac ket (lo w profile) I. Video connector C. PCI card brac ket (full height) J . NIC 1 conne ctor D . AC P ower Receptacle K. NIC 2 connector E. Management Network Interface (optional) L. RJ45 ...

  • Intel SR1500AL - page 40

    18 Intel ® Server System SR1500AL User’s Guide P eripheral Devices The server system provides lo cations and hardware for in stalling hard drives, a USB floppy drive, and an opt ical drive. The drives must be purchased separately . The followi ng figure shows the available options. . Figure 13. Optional P eripherals Har d Disk Drives The server ...

  • Intel SR1500AL - page 41

    Intel ® Server System SR1500AL User’s Guide 19 Slimline Optical Drive Carrier The slimline optical drive carrier can be used with an optional optical drive. One slimline carrier is included with your server system; th e optical drive must be purchased separately . Y ou cannot install b oth an optical drive and a US B floppy drive. The slimline o ...

  • Intel SR1500AL - page 42

    20 Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 43

    3 Har dware Installations and Upgrades Bef ore Y ou Begin Before working with your server product, pay close attention to the “Safety Information” at the beginning of this manual. T ools and Supplies Needed • Phillips* (cross head) screwd rivers (#1 bit and #2 bit) • Needle nosed pliers • Antistatic wrist strap and cond uctive foam pad (r ...

  • Intel SR1500AL - page 44

    22 Intel ® Server System SR1500AL User’s Guide Fixed Brac ket Rack Mount Installation 1. Fully extend a rail asse mbly; the finger tab for the extension lock is revealed. 2. Press the finger tab and slide the inside rail from the middle rail until it completely separates. Note: The middle rail and outer rail cannot be separated. 3. Position an i ...

  • Intel SR1500AL - page 45

    Intel ® Server System SR1500AL User’s Guide 23 22. Fully extend the left and ri ght rails un til the extension locks have engaged and the rails will not push back in. The rail sy stem is now ready to receive the chassis. Caution: Lifting and placing the chassis in the rails is a two-person job. If needed, use an appr opriate lifting device. 23. ...

  • Intel SR1500AL - page 46

    24 Intel ® Server System SR1500AL User’s Guide 1 1. Slide the server chassis all the way into the rack. 12. Use the rack screws (#10-32 x 3/4) to se cure the chassis and rack handles into the rack. T ool-less Rail Rack Mount Servicing 1. T o service the system, pull the system out from the rack. 2. Disconnect the power cable(s) and proceed with ...

  • Intel SR1500AL - page 47

    Intel ® Server System SR1500AL User’s Guide 25 Remo ving the Fr ont Bezel Use the steps below if your sy stem includes a front bezel. 1. Unlock the bezel. 2. Disconnect any cables attached to the control panel. 3. Pull the bezel from the server syst em. Figure 16. Remo ving the Fr ont Bezel TP02199 ...

  • Intel SR1500AL - page 48

    26 Intel ® Server System SR1500AL User’s Guide Installing the Fr ont Bezel Use the steps below if your system includes e ither the standard front bezel or the front bezel for the Intel ® Local Control Panel. The front bezel is optional. 1. At eac h end of the bezel, line up the center notch on the bezel with the center guide on the rack handles ...

  • Intel SR1500AL - page 49

    Intel ® Server System SR1500AL User’s Guide 27 2. Turn of f all peripheral devices connected to the server . T urn off the server . 3. Disconnect the AC power cord(s). 4. Remove the safety screw if it is inst alled. See letter "A" in the figure below . 5. While holding in the blue button at the top of the server system in (see letter & ...

  • Intel SR1500AL - page 50

    28 Intel ® Server System SR1500AL User’s Guide Figure 19. Installing the Server System Co ver Remo ving and Installing the Pr ocessor Air Duct Always operate your server serve r system with the processor air duct in place. The air duct is required for proper airflow within the server system. For instructions on adding or replacing a pr ocessor , ...

  • Intel SR1500AL - page 51

    Intel ® Server System SR1500AL User’s Guide 29 Figure 20. Remo ving the Pr ocessor Air Duct TP02201 ...

  • Intel SR1500AL - page 52

    30 Intel ® Server System SR1500AL User’s Guide Installing the Pr ocessor Air Duct 1. Observe the safety and ESD precautions at the be ginning of this book. See " “Safety Information” . 2. Power down the server and unplug a ll peripheral devices and the AC po wer cable(s). 3. Remove the server system co ver . For instructions, see “Rem ...

  • Intel SR1500AL - page 53

    Intel ® Server System SR1500AL User’s Guide 31 Figure 22. Installing the Pr ocessor Air Duct Installing and Remo ving Memory The silkscreen on the board for the DIMMs displays DIMM A1, DIMM A2, DIMM B1, DIMM B2, DIMM C1, DIMM C2, DIMM D1 and DIMM D2 starting from the center of the board. See "Memory" for a discussion of the memory requ ...

  • Intel SR1500AL - page 54

    32 Intel ® Server System SR1500AL User’s Guide Figure 23. Installing the Memory 6. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position (see letter “A ” in the figure above). 7. Holding the DIMM by the edges, re move it from its anti-static package. 8. Position the DIMM above the socket. Alig n the ...

  • Intel SR1500AL - page 55

    Intel ® Server System SR1500AL User’s Guide 33 1 1. Replace the system's cover and reconnect th e AC power cord(s). For instructions on installing the system's cover , see “Installing the System Cover” . Remo ving DIMMs T o remove a DIMM, follow these steps: 1. Obs erve the safety and ESD precautions in “Safety Information” . 2 ...

  • Intel SR1500AL - page 56

    34 Intel ® Server System SR1500AL User’s Guide 4. Remove the system's cove r . For instructions, see “Removing the System Cover” . 5. Remove the processor air duct. For instructions, see “Re moving the Processor Air Duct” . 6. Remove the heat sink, if installed. 7. Locate the processor socket and raise the socket handle completely ( ...

  • Intel SR1500AL - page 57

    Intel ® Server System SR1500AL User’s Guide 35 10. Remove the protective socket cover (see Figure 26 ). Note: Retain the pr otective socket cover for use w hen r emoving a processor that will not be re p l a c e d . Figure 26. Remo ving the Soc ket Co ver 1 1 . Lower the CPU load plate and lower the socket lever completely . Installing the Heat ...

  • Intel SR1500AL - page 58

    36 Intel ® Server System SR1500AL User’s Guide Figure 27. Installing the Heat Sink (2U P assive Heat Sink Shown) 4. Reinstall and reconnect any parts you removed or disconnected to rea ch the processor sockets. 5. Replac e the system's cover and reconnect the AC power cord(s). For instructions on installing the system's cover , see “ ...

  • Intel SR1500AL - page 59

    Intel ® Server System SR1500AL User’s Guide 37 9. Raise the CPU load pla te. 10. Remove the processor . 1 1 . If installing a repl acement processor , see “Installing the Processor” . Otherwise, install the protective socket cover over the empty processor socket and reinstall the s y s t e m ’s c o v e r. Remo ving and Installing the Small ...

  • Intel SR1500AL - page 60

    38 Intel ® Server System SR1500AL User’s Guide Remo ving the Small Air Baffle 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” . 2. Power down the server and unplug a ll peripheral devices and the AC po wer cable(s). 3. Remove the server system co ver . For instructions, see “Removing the Sy ...

  • Intel SR1500AL - page 61

    Intel ® Server System SR1500AL User’s Guide 39 Figure 29. Installing the Small Air Baffle 3. Insta ll the server system cover . For inst ructions, see “Installing the System Cover” . 4. Plug all peripheral devic es and th e AC power cable(s) into the server . Installing and Remo ving a Hot-s wap Har d Drive Up to three hot-swap SAS or SA T A ...

  • Intel SR1500AL - page 62

    40 Intel ® Server System SR1500AL User’s Guide Figure 30. Remo ving Hot-swap Disk Carrier fr om the Ser ver System 4. Remove the four screws that atta ch the plastic retention device or the p reviously installed hard drive to the drive carrier . T w o screws are at each side of the retention device or the hard drive. Store the plastic retention ...

  • Intel SR1500AL - page 63

    Intel ® Server System SR1500AL User’s Guide 41 Figure 32. Installing Har d Drive into Carrier 9. With the black lever in the fully open po sition, slide the drive assembly into the server system. The green latch at the front of the drive carrier must be to the right. Do not push on the black drive carrier leve r unt il the lever begins to close ...

  • Intel SR1500AL - page 64

    42 Intel ® Server System SR1500AL User’s Guide Remo ving a SAS or SA T A Hot-swap Har d Disk Drive 1. Remove the front bezel if it is installed. For instructions, see “Removing the F ront Bezel” . 2. Press in on the green latch at the front of the hard drive carrier . 3. Pull out on the black lever to s lide the carrier from the server syste ...

  • Intel SR1500AL - page 65

    Intel ® Server System SR1500AL User’s Guide 43 Installing a Slimline Optical Drive or Internal USB Floppy 1. Obs erve the safety and ESD precautions at the beginning of this bo ok. See “Safety Information” . 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the front be zel if it is installed. Fo ...

  • Intel SR1500AL - page 66

    44 Intel ® Server System SR1500AL User’s Guide Figure 35. Installing an Optical Drive Assemb ly into the Server System 14. Install the server system cover . For instructions, see “Installing the System Cover” . 15. (Optional) Install the front bezel. For instructions, see “Installing the Front Bezel” . 16. Plug all peripheral devices and ...

  • Intel SR1500AL - page 67

    Intel ® Server System SR1500AL User’s Guide 45 Figure 36. Remo ving the Slimline Optical Drive Assemb ly fr om the Server System 7. Pre ss downward on the side of the tray (see letter “A”) and disengage the drive from the two metal tabs on the opposite side of the tray . 8. Slide the optical drive out (see lette r “B”) to remove it from ...

  • Intel SR1500AL - page 68

    46 Intel ® Server System SR1500AL User’s Guide Figure 37. Remo ving the Slimline Optical Drive fr om the T ray Filling Empty Server System Bays A filler panel, drive blank, or empty drive carrier must be installed into an empty drive bay . T o access the drive bays, remove the front bezel if it is installed. For instructions, see “Removing the ...

  • Intel SR1500AL - page 69

    Intel ® Server System SR1500AL User’s Guide 47 Installing and Remo ving the PCI Riser Assemb l y Remo ving the PCI Riser Assembl y T o remove the PCI riser assembly , use the following instructions. 1. Obs erve the safety and ESD precautions at the beginning of this bo ok. See “Safety Information” . 2. Power down the server and unplug all pe ...

  • Intel SR1500AL - page 70

    48 Intel ® Server System SR1500AL User’s Guide 8. If you need to add or replace a PCI add-in card , see “Installing and Removing a PCI Add-in Card” . 9. If you need to add or replace a PCI riser connector , see “Replacin g a PCI Riser Card” . 10. If you removed the PCI riser assembly for another procedure, continue with that procedure. I ...

  • Intel SR1500AL - page 71

    Intel ® Server System SR1500AL User’s Guide 49 Replacing a PCI Riser Car d Caution: PCI riser connectors ar e NOT hot swappable. Befor e removing or r eplacing the riser connector , you must first tak e the server out of service, turn off all peripheral devices connected to the system, turn off the system by pr essing the po wer button, and unpl ...

  • Intel SR1500AL - page 72

    50 Intel ® Server System SR1500AL User’s Guide Figure 40. Remo ving the PCI Express* Riser Car d fro m the Server System 10. Install the replacement ri ser connector , if desired. For instructions, see “Installing the PCI-X* Riser Card into the Server System” . 1 1. Install the PCI add-in card(s) if desired. For instructions, see “Installi ...

  • Intel SR1500AL - page 73

    Intel ® Server System SR1500AL User’s Guide 51 Installing the PCI-X* Riser Car d 1. Obs erve the safety and ESD precautions at the beginning of this bo ok. See “Safety Information” . 2. Power down the server and unplug all peripheral devices and the AC power cable(s). 3. Remove the se rver system cover . For instructions, se e “Removing th ...

  • Intel SR1500AL - page 74

    52 Intel ® Server System SR1500AL User’s Guide 16. Install the server system cover . For instructions, see “Installing the System Cover” . 17. Plug all peripheral devices and the AC power cable(s) into the server . Installing and Remo ving a PCI Ad d-in Car d The instructions below desc ribe how to install and remove a PCI add-in card. Insta ...

  • Intel SR1500AL - page 75

    Intel ® Server System SR1500AL User’s Guide 53 10. Install the PCI riser assembly into th e server system. For instructions, see “Installing the PCI Riser Assembly” . 1 1 . Install the processor air duct. For instructions, see “Installing the Processor Air Duct” . 12. Install the server system cover . For instructions, see “Installing ...

  • Intel SR1500AL - page 76

    54 Intel ® Server System SR1500AL User’s Guide 10. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” . 1 1. I nstall the server system cover . For instructions, see “Installing the System Cover” . 12. Plug all peripheral devices and the AC power cable(s) into the server . Installing and Remo ving t ...

  • Intel SR1500AL - page 77

    Intel ® Server System SR1500AL User’s Guide 55 7. Insta ll the PCI riser assembly into th e server system. For instructions, see “Installing the PCI Riser Assembly” . 8. Insta ll the processor air duct. For instructions, see “Installing the Processor Air Duct” . 9. Insta ll the server system cover . For inst ructions, see “Installing t ...

  • Intel SR1500AL - page 78

    56 Intel ® Server System SR1500AL User’s Guide 9. Install the processor air duct. For instructions, see “Insta lling the Processor Air Duct” . 10. Install the server system cover . For instructions, see “Installing the System Cover” . 1 1. Plug all peripheral devices and the AC power cable(s) into the server . Installing and Remo ving th ...

  • Intel SR1500AL - page 79

    Intel ® Server System SR1500AL User’s Guide 57 9. Insta ll the PCI riser assembly into th e server system. For instructions, see “Installing the PCI Riser Assembly” . 10. Install the processor air duct. For instructions, see “Installing the Processor Air Duct” . 1 1 . Install the server system cove r . For instructions, see “Installing ...

  • Intel SR1500AL - page 80

    58 Intel ® Server System SR1500AL User’s Guide 1 1. I nstall the server system cover . For instructions, see “Installing the System Cover” . 12. Plug all peripheral devices and the AC power cable(s) into the server . Replacing the Bac k plane Boar d The instructions below describe ho w to replace the backplane board. Remo ving the Bac kplane ...

  • Intel SR1500AL - page 81

    Intel ® Server System SR1500AL User’s Guide 59 6. Loosen the captive screw on the backpl ane board (see letter “A” in the figure below). 7. Hold the backplane boa rd on ly by the edges. Slide the backplane board to the right to release it (see letter “B” in the figure below). 8. Lift the ba ckplane board over the retention pins (see lett ...

  • Intel SR1500AL - page 82

    60 Intel ® Server System SR1500AL User’s Guide Figure 50. Installing the Bac kplane into the Server Sy stem 6. Connect cables as neces sary to the backplane board. A B C AF000371 D ...

  • Intel SR1500AL - page 83

    Intel ® Server System SR1500AL User’s Guide 61 7. Insta ll the bridge board by opening the re tention mechanism (see letter “A” in the figure below) and inserting it into the conn ector on the server board (see letter “B” in the figure below). Close the retention mechanism to hold the bridge board in place. Figure 51. Installing the Brid ...

  • Intel SR1500AL - page 84

    62 Intel ® Server System SR1500AL User’s Guide Installing and Remo ving the Server Boar d Installing the Server Board 1. Observe the safety and ESD precautions at the beginning of this book. See “Safety Information” . 2. Power down the server and unplug a ll peripheral devices and the AC po wer cable(s). 3. Remove the server system co ver . ...

  • Intel SR1500AL - page 85

    Intel ® Server System SR1500AL User’s Guide 63 8. Insta ll the PCI riser assembly . For instructions, see “Installing the PCI Riser Assembly” . 9. Insta ll the processor air duct. For instructions, see “Installing the Processor Air Duct” . 10. Install the server system cover . For instructions, see “Installing the System Cover” . 1 1 ...

  • Intel SR1500AL - page 86

    64 Intel ® Server System SR1500AL User’s Guide 7. Install the replaceme nt server board. For instructions, see “Installing the Server Board” . 8. Install the PCI riser assembly . For instructions, see “Installing the PCI Riser Assembly” . 9. Install the processor air duct. For instructions, see “Insta lling the Processor Air Duct” . ...

  • Intel SR1500AL - page 87

    Intel ® Server System SR1500AL User’s Guide 65 1. Obs erve the safety and ESD precautions in “Safety Information” . 2. Turn of f all peripheral devices connected to the server . T urn off the server . 3. Disconnect the AC power cord(s) from the server . 4. Remove the se rver's cover and locate the battery . See the documentation that ca ...

  • Intel SR1500AL - page 88

    66 Intel ® Server System SR1500AL User’s Guide Replacing the P o wer Supply Caution: The power supply is not h ot-swappable. Befor e removin g or r eplacing the power supply , you must first take the server out of service, turn off all peripheral devices connected to the system, turn off the system by pr essing the power button, and unplug the A ...

  • Intel SR1500AL - page 89

    Intel ® Server System SR1500AL User’s Guide 67 6. Insta ll the server system cover . For inst ructions, see “Installing the System Cover” . 7. Plug all peripheral devic es and th e AC power cable(s) into the server . Replacing the Contr ol P anel The steps for replacing the standard control panel and the Intel ® Local Control Panel are near ...

  • Intel SR1500AL - page 90

    68 Intel ® Server System SR1500AL User’s Guide Figure 57. Remo ving the Intel ® Local Contr ol P anel Module 8. Slide the replacement control panel into the server system (see letter “A”) until it clicks into place. 9. Connect the front panel and USB cables to the c onnectors on the backplane (see letters “B” and “C”). Figure 58. In ...

  • Intel SR1500AL - page 91

    Intel ® Server System SR1500AL User’s Guide 69 Replacing a System F an Caution: The system fans ar e NOT hot swappable. Befor e removin g or r eplacing a fan , you must first take the server out of service, turn off a ll peripheral devices connecte d to the system, turn off the system by pr essing the power butt on, and unp lug the AC power cor ...

  • Intel SR1500AL - page 92

    70 Intel ® Server System SR1500AL User’s Guide Figure 60. I Installing a F an into the F an Module 7. Install the server system cover . For instructions, see “Installing the System Cover” . 8. Plug all pe ripheral devices and the AC power cable(s) into the serv er . Installing and Remo ving the Rac k Handles Installing the Rac k Handles 1. O ...

  • Intel SR1500AL - page 93

    Intel ® Server System SR1500AL User’s Guide 71 Figure 61. I Installing the Rac k Handle 6. Insta ll the server system cover . For inst ructions, see “Installing the System Cover” . 7. Insta ll the front bezel. For instructions, see “Installing the Front Bezel” . 8. Plug all peripheral devic es and th e AC power cable(s) into the server . ...

  • Intel SR1500AL - page 94

    72 Intel ® Server System SR1500AL User’s Guide Figure 62. I Remo ving the Rac k Handle 6. Install the server system cover . For instructions, see “Installing the System Cover” . 7. Plug all pe ripheral devices and the AC power cable(s) into the serv er . AF000378 ...

  • Intel SR1500AL - page 95

    4 Ser ver Utilities Using the BIOS Setup Utility This section describes the BIOS Setup Utility options, which is used to change server configuration defau lts. Y ou can run BIOS Se tup with or without an operating system being present. See “Server Syste m Refe rences” for a link to the Intel ® 5000 Series Chipsets Server Board Family Datasheet ...

  • Intel SR1500AL - page 96

    74 Intel ® Server System SR1500AL User’s Guide “Setup Menu Key Use” describes the keyboard commands you can use in the BIOS Setup menus. T able 4. S etu p Me nu Key U se Ke y to Press Description <F1> Pressing <F1> on any menu in vok es the general help window . Left and r ight arrows The le ft and righ t arrow ke ys are used to ...

  • Intel SR1500AL - page 97

    Intel ® Server System SR1500AL User’s Guide 75 Upgrading the BIOS The upgrade utility allows you to upgrade the BIOS in fl ash me mory . The code and data in the upgrade file in clude the following: • On-board system BIOS, in cluding the recovery code , BIOS Setup Utility , and strings. • On-board video BIOS, and o ther option ROMs for devic ...

  • Intel SR1500AL - page 98

    76 Intel ® Server System SR1500AL User’s Guide Obtaining the Upgr ade Download the BIOS image file to a tem porary folder on your hard d rive. See “Server System References” for a link to the update software. Note: Review the instructions and r elease notes that ar e pr ovided in the re adme file distributed with the BIOS image file befor e ...

  • Intel SR1500AL - page 99

    Intel ® Server System SR1500AL User’s Guide 77 Figure 63. Clear P asswor d Jumper 4. W ait five seconds. 5. Return the Password Clear jumper to the Password Clear Protec t position, covering pins 1 and 2. 6. Close the server chassis. 7. Reconnec t the AC power and power up the server . 8. The password is now cleare d and can be reset by going in ...

  • Intel SR1500AL - page 100

    78 Intel ® Server System SR1500AL User’s Guide Figure 64. Clear CMOS J umper 4. W ait five seconds. 5. Return the CMOS Clear jumper to the CMOS Clear by BMC location, covering pins 1 and 2. 6. Close the server chassis. 7. Reconnect the AC power and power up the system. 8. The CMOS is now cleared and can be reset by going into the BIO S setup. TP ...

  • Intel SR1500AL - page 101

    Appendix A: T echnical Reference Cable Routing When you add or remove components from y our server system, make sure your cables are routed correctly before reinstalling the server system cover . Use cau tion to make sure no cables or wires are pinched and that the airfl ow from the fans is not blocked. Use the figures below to determine the correc ...

  • Intel SR1500AL - page 102

    80 Intel ® Server System SR1500AL User’s Guide SA T A Connections Use the figure below to determ ine the proper SA T A cabling. Figure 66. Connecting SA T A Cables 0 2 1 1 0 2 A A B AF000375 ...

  • Intel SR1500AL - page 103

    Intel ® Server System SR1500AL User’s Guide 81 Figure 67. Cab ling Aroun d the Small Air Baffle 600W Single P o wer Suppl y Input V oltages • 100-127V at 50/60 Hz; 8.55 A max. • 200-240V at 50/60 Hz; 4.3 A max. AF000376 A B ...

  • Intel SR1500AL - page 104

    82 Intel ® Server System SR1500AL User’s Guide 600W Single P o wer Suppl y Output V oltages The table below lists the total wattage av ailable from the power subsystem for each voltage. Ensure that your lo ads do not exceed the combined total wattage of 600 W atts. For information about calcul ating the power usage for your config uration, see & ...

  • Intel SR1500AL - page 105

    Intel ® Server System SR1500AL User’s Guide 83 System En vir onmental Specifications T able 6. System En vironmental Specifications T emperature Non-operating Operating -40 ° to 70 °C. 10 ° to 35 °C; derated 0.5 °C f or e v ery 10 00 ft (305 m) to a maximum of 10,000 ft. Humidity Non-operating 90% relative humidity (non-condensing) at 30 ° ...

  • Intel SR1500AL - page 106

    84 Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 107

    Appendix B: T roub leshooting This chapter helps you identify and solve problems that mi ght occur while you are using the system. For any issue, first ensure you are using the latest firmware and files. Firmware upgrades include updates for BIOS, the Baseboard Ma nagement Controller (BMC), and the hot- swap controller (HSC). See “Server System R ...

  • Intel SR1500AL - page 108

    86 Intel ® Server System SR1500AL User’s Guide Pr ob lems f ollowing Initial System Installation Problems that occur at initial system startup are usually ca used by an incorrect installation or configuration. Hardware failure is a less frequent cause. If the problem you are experiencing is with a specifi c software application, see “Problems ...

  • Intel SR1500AL - page 109

    Intel ® Server System SR1500AL User’s Guide 87 Har d ware Diagnostic T esting This section provides a more detailed approach to identifying a hardware problem and locating its sourc e. Caution: T urn off devices before disconnecting cables : Befor e disconnecting an y periph eral ca bles fr om the system, turn off the system and any external per ...

  • Intel SR1500AL - page 110

    88 Intel ® Server System SR1500AL User’s Guide Specific Pr ob lems and Corrective Actions This section provides possible solu tions for these specific problems: • Power light does not light. • No characters appear on screen. • Characters on the screen appear distorted or incorrect. • System cooling fans do not rotate. • Diskette drive ...

  • Intel SR1500AL - page 111

    Intel ® Server System SR1500AL User’s Guide 89 No Characters Appear on Screen Check the following: • Is the keyboard functioni ng? T est it by turn ing the "Num Lock" function on and of f to make sure the Num Lock light is funct ioning. • Is the video monitor plu gged in and turned on? If you are using a switch box, is it switched ...

  • Intel SR1500AL - page 112

    90 Intel ® Server System SR1500AL User’s Guide • Does this video monitor work correctly if plugged into a dif ferent system? System Cooling F ans Do Not Rotate Pr operly If the system cooling fans are not operating properly , it is an indication of possible system component failure. Check the following: • Is the power-on light lit? If not, s ...

  • Intel SR1500AL - page 113

    Intel ® Server System SR1500AL User’s Guide 91 Cannot Connect to a Server • Make sure the network cable is securely a ttached to the correct connector at the system back panel. • T ry a different network cable. • Make sure you are using the correct and the current drivers. See “Server System References” for a link to the current driver ...

  • Intel SR1500AL - page 114

    92 Intel ® Server System SR1500AL User’s Guide • The network driver file s may be corrupt or deleted. Delete and then reinstall the drivers. • Run diagnostics. System Boots when Installing PCI Car d System Management features require full-tim e "sta ndby" power . This means som e parts of the system have power go ing to them when e ...

  • Intel SR1500AL - page 115

    Intel ® Server System SR1500AL User’s Guide 93 • If the problems are intermittent, there may be a loose cable, dirt in the keyboard (if keyboard input is incorrect ), a m arginal power supply , or other random comp onent failures. • If you suspect that a transient voltage spik e, power outage, or brown out might have occurred, reload the sof ...

  • Intel SR1500AL - page 116

    94 Intel ® Server System SR1500AL User’s Guide LED Inf ormation The Intel ® Server Board S5000P AL includes LEDs th at can aid in troubleshooting your system. A table of these LEDs with a d escription of their use is listed below . BIOS POST Beep Codes The table below lists the POST error beep code s. Prior to syst em video initialization, the ...

  • Intel SR1500AL - page 117

    Intel ® Server System SR1500AL User’s Guide 95 In addition to the beep codes above, additio nal beep codes are provided if an Intel ® Remote Management Module is installed. The Intel ® Remote Management Module provides the following ad ditional beep codes. T able 10. Error Beep Co des Generated by Intel ® Remote Mana gement Module Number of B ...

  • Intel SR1500AL - page 118

    96 Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 119

    Appendix C: Intel ® Server Issue Repor t Form Note: An on-line / automatic submission version of this form is available at http:// support.intel.com/support/motherboar ds/server/ chassis/SR1500/. For the fastest service, please submit your form via the Internet. Date Submitted: ______ ______________ ________________________ ___________ Company Nam ...

  • Intel SR1500AL - page 120

    98 Intel ® Server System SR1500AL User’s Guide DIMM Configuration DIMM A1 MB and V endor / part number: ________________ ______________ ____ DIMM A2 MB and V endor / part number: ________________ ______________ ____ DIMM B1 MB and V endor / part number: ___ _____________ ______________ ____ DIMM B2 MB and V endor / part number: ___ _____________ ...

  • Intel SR1500AL - page 121

    Intel ® Server System SR1500AL User’s Guide 99 Hard Driv e Inf or mation Management Inf or mation On-Board Platform Instrumentatio n only __________________ _____________ ____ Intel ® Remote Management Module ___________________ ____________ ________ Control P anel Inf or mation S tandard Control Panel ____________________ ______________ ______ ...

  • Intel SR1500AL - page 122

    100 Intel ® Server System SR1500AL User’s Guide Complete Prob lem Description In the space below , provide a complete description of the steps used to reproduce the problem or a comp lete description of w here the problem can be found. Please also include any details on troubleshooting already done. __________ ___________ ___________ ___________ ...

  • Intel SR1500AL - page 123

    Appendix D: LED Decoder During the system boot process, BIOS execu tes a number of platform configuration processes, each of which is assigned a specific hex POST code number . As each configuration routine is star ted, BIOS will display the gi ven POST code to the POST Code Diagnostic LEDs found on the back ed ge of the server board. T o assist in ...

  • Intel SR1500AL - page 124

    102 Intel ® Server System SR1500AL User’s Guide Figure 68. Diagnostic LED Placeme nt Diagram LSB MSB Back edge of server board USB Po rt USB Po rt Diagnostic LEDs T able 12. Diagnostic LED POST Code De coder Checkpoint Diagnostic LED Decoder Description G=Green, R=Red, A=Amber MSB LSB Host Processor 0x10h OFF OFF OFF R P ower-on initializati on ...

  • Intel SR1500AL - page 125

    Intel ® Server System SR1500AL User’s Guide 103 PCI Bus 0x50h OFF R OFF R Enumer ating PCI busses 0x51h OFF R OFF A Allocating resources to PCI busses 0x52h OFF R G R Hot Plug PCI controller initialization 0x53h OFF R G A Reser ved f or PCI bus 0x54h OFF A OFF R Reser ved f or PCI bus 0x55h OFF A OFF A Reser ved for PCI b us 0x56h OFF A G R Rese ...

  • Intel SR1500AL - page 126

    104 Intel ® Server System SR1500AL User’s Guide 0x93h R OFF G A Enabling the ke yboard 0x94h R G OFF R Clearing keyboard input buff er 0x95h R G OFF A Instructing ke yboard controller to run Self T est (PS2 only) Mouse (PS2 or USB) 0x98h A OFF OFF R Resetting the mouse 0x99h A OFF OFF A Detecting the mouse 0x9Ah A OFF G R Detecting the presence ...

  • Intel SR1500AL - page 127

    Intel ® Server System SR1500AL User’s Guide 105 0XD A A R G R T r ying boot de vice selection 0xDB A R G A T r ying boot device selection 0xDC A A OFF R T r ying boot device selection 0xDE A A G R T r ying boot device selection 0xDF A A G A T r ying boot device selection Pre-EFI Initializat ion (PEI) Core 0xE0h R R R OFF Star te d dispatching ea ...

  • Intel SR1500AL - page 128

    106 Intel ® Server System SR1500AL User’s Guide 0xF Ah A R A R Operating system has requested the system to reset (ResetSystem () has been called) Pre-EFI Initiali zation Module (PEI M) / Recovery 0x30h OFF OFF R R Crisis recovery has been initiated because of a user request 0x31h O FF OFF R A Crisis recove r y ha s been initiated by software (c ...

  • Intel SR1500AL - page 129

    Appendix E: Getting Help Wo r l d W i d e W e b http://support.intel.com/support/motherboards/server/chassis/SR1500. T elephone All calls are billed per incident, levied in local currency at the ap plicable credit card exchange rate plus applicable taxes. (Intel reserves the right to change the pricing for telephone support at any time without no t ...

  • Intel SR1500AL - page 130

    108 Intel ® Server System SR1500AL User’s Guide In Asia-P acific region Australia .... 1800 649931 Cambodia .. 63 2 636 9797 (via Phili ppines) China ......... 800 820 1 100 (toll-free) ................... . 8 621 33104691 (not toll-free) Hong Kong 852 2 844 4456 India ........... 0006517 2 68303634 (manual toll-free. Y ou need an IDD-equipped t ...

  • Intel SR1500AL - page 131

    Intel ® Server System SR1500AL User’s Guide 109 Colombia ... Contact A T&T USA at 01 800 91 1 0010. Once connected , dial 800 84 3 4481 Costa Rica . Contact A T&T USA at 0 800 0 1 14 1 14. Once connected, dial 800 843 4481 Ecuador (Andimate) .... Contact A T&T USA at 1 999 1 19. Once connected, dial 800 843 4 481 (Pacifictel) ..... C ...

  • Intel SR1500AL - page 132

    110 Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 133

    Appendix F: Regulator y and Compliance Inf ormation Pr oduct Regulatory Compliance Wa r n i n g : T o ensure r egulatory compliance, you must adher e to the a ssembly instructions in this guide to ensur e and mainta in compliance with existing pr oduct certifications and appr ovals. Use only th e described, r egulated components specified in this g ...

  • Intel SR1500AL - page 134

    112 Intel ® Server System SR1500AL User’s Guide • CB Certificate & Report, IE C60950 (report to incl ude all country national deviations) • GS License (Germany) • GOST R 50377-92 - License (Russia) • Belarus License (Belarus) • Ukraine License (Ukraine) • CE - Low V oltage Directive 73/23/EEE (Europe) • IRAM Certification (Ar g ...

  • Intel SR1500AL - page 135

    Intel ® Server System SR1500AL User’s Guide 113 Cer tifications / Registrations / Dec larations • UL Certification (US/Canada) • CE Declaration of Conformity (CENELEC Europe) • FCC/ICES-003 Class A Attestation (USA/Canada) • VCCI Certification (Japan) • C-T ick Declaration of Conformity (Australia) • MED Declaration of Conformity (Ne ...

  • Intel SR1500AL - page 136

    114 Intel ® Server System SR1500AL User’s Guide C-Tick Mark A ustralia / New Zealand VCCI Mark ing (Class A) Japan BSMI Cer tification Number & Class A Wa r n i n g Ta i w a n GOST R Marking Russia RRL MIC Mar k K orea China Compulsor y Cer tification Mar k Chi na T able 13. Product Re gulatory Compliance Markings Regulatory Com pliance Regi ...

  • Intel SR1500AL - page 137

    Intel ® Server System SR1500AL User’s Guide 115 Electr oma gnetic Compatibility Notices FCC V erification Statement (USA) This device complies with Part 15 of the FCC Rules. Operatio n is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, incl ud ...

  • Intel SR1500AL - page 138

    116 Intel ® Server System SR1500AL User’s Guide Industry Canada (ICES-003) Cet appareil numérique respecte les limites bruits radioé lectriques applicables aux appareils numériques de Classe A prescrites da ns la norme sur le matériel brouilleur: "Apparelis Numériques", NMB-00 3 édictee par le Ministre Canadian des Communications ...

  • Intel SR1500AL - page 139

    Intel ® Server System SR1500AL User’s Guide 117 K orean Compliance (RRL) Following is the RRL certification information for Korea. English translation of the notice above: 1. T ype of Equipment (Model Name): On License and Product 2. Certification No.: On RRL certificat e. Obtain certificate from local Intel representative 3. Name of Certificati ...

  • Intel SR1500AL - page 140

    118 Intel ® Server System SR1500AL User’s Guide • Add-in boards: must have a printed wiring board flammability rating of minimum UL94V -1. Add-in boards containing ex ternal power connectors and/or lithium batteries must be UL recognized o r UL listed. Any add-in board containing modem telecommunication circuitry must be UL listed. In addition ...

  • Intel SR1500AL - page 141

    Appendix G: W a rranty Limited W arranty f or Intel® Chassis Subassembl y Pr oducts Intel warrants that the Products (defined here in as the Intel® cha ssis subassembly and all of its various co mponents and software delive red with or as part of the Products) to be delivered hereunde r , if pro perly used and inst alled, will be free from defect ...

  • Intel SR1500AL - page 142

    120 Intel ® Server System SR1500AL User’s Guide This Limited W arranty does not cover damages due to exte rnal causes, including accident, problems with electrical power , usage not in accordance with product instructions, misuse, neglect, alteration, repair , improp er installation, or improper testi ng. W arranty Limitations and Exc lusions Th ...

  • Intel SR1500AL - page 143

    Intel ® Server System SR1500AL User’s Guide 121 • North America and Latin America T o obtain warranty repair for the product, please go to the following W eb site to obtain in structions: http://support.intel.com/support/ motherboards/draform.htm • In Europe and in Asia Contact your orig inal authorized distributor for warranty service. Any ...

  • Intel SR1500AL - page 144

    122 Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 145

    Intel ® Server System SR1500AL User’s Guide 123 Appendix H: Installation/Assemb ly Saf ety Instructions English The power supply in this product contains no user-serviceable par ts. Refer servicing o nly to qualified personnel. Do not attempt to modify or use the supplied AC po wer cord if it is not the e xact type required. A product with more ...

  • Intel SR1500AL - page 146

    124 Intel ® Server System SR1500AL User’s Guide After you ha v e completed the six SAFETY steps abov e, y o u can remov e the system co v ers. T o do this: 1. Unlock and remo v e the padloc k from the ba ck of the system if a padlock has been installed. 2. Remov e and save all scre ws from the covers . 3. Remov e the cover(s). F or proper coolin ...

  • Intel SR1500AL - page 147

    Intel ® Server System SR1500AL User’s Guide 125 Deutsch Benutzer k önnen am Netzgerät die ses Produkts keine Reparaturen vornehmen. Das Produkt en thält möglicherweise mehrere Netzgeräte. W ar tungsarbeiten müssen von qualifizierten T echnikern ausgeführ t werden. V ersuchen Sie nicht, das mitgeliefer te Netzkabel zu änder n oder zu verw ...

  • Intel SR1500AL - page 148

    126 Intel ® Server System SR1500AL User’s Guide SICHERHEISMASSNAHMEN: Immer w enn Sie die Gehäuseabdeckung abnehmen um an das Systeminnere zu gelangen, sollte n Sie folgende Schritte beachten: 1. Schalten Sie alle an Ihr System angeschlossenen P eripher iegeräte aus. 2. Schalten Sie das System mit dem Hauptschalter aus. 3. Ziehen Sie den Strom ...

  • Intel SR1500AL - page 149

    Intel ® Server System SR1500AL User’s Guide 127 Français Das System wurde für den Betrieb in ein er normalen Büroumgebung entwic kelt. Der Standor t sollte: • "sauber und staubfrei sein (Hausstaub ausgeno mmen); • "gut gelüftet und keinen Heizquellen ausgese tzt sein (einschließlich direkter Son neneinstrahlung); • "kei ...

  • Intel SR1500AL - page 150

    128 Intel ® Server System SR1500AL User’s Guide CONSIGNES DE SÉCURITÉ -Lorsque vous ouvrez le boîtier pour accéder à l'intérieur du système, suivez les consignes suivantes: 1. Mettez hors tension tous les pér iphériq ues connectés au système. 2. Mettez le système hors tens ion en mettant l'interrupteur général en position ...

  • Intel SR1500AL - page 151

    Intel ® Server System SR1500AL User’s Guide 129 Español Danger d'explosion si la batter ie n'est pas remontée correctement. Remplacer uniquement av ec une batter ie du même type ou d'un type équivalent recommandé par le f abrican t. Disposez des piles usées selon les instr uctions du f abrica nt. Le système a été conçu p ...

  • Intel SR1500AL - page 152

    130 Intel ® Server System SR1500AL User’s Guide Nótese que el interruptor activado/desactivado en el panel frontal no desconecta l a corriente al terna del sistema. P ara desconectarla, deberá desenchufar todos los cables de corriente alter na de la pared o desconectar la fuente de al imentación. INSTR UCCIONES DE SEGURID AD: Cuando e xtraiga ...

  • Intel SR1500AL - page 153

    Intel ® Server System SR1500AL User’s Guide 131 Chinese Si el sistema ha estado en funcionam iento, el microprocesador y el disipador de calor pueden estar aún cal ientes. T ambié n conviene tener en cuenta que en el chas is o en el tablero puede haber piezas cor tantes o punzantes. P or ello , se recomienda precauci ón y el uso de guantes pr ...

  • Intel SR1500AL - page 154

    132 Intel ® Server System SR1500AL User’s Guide Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti d ell'alimentazione di questo prodotto . È possibile che i l prodotto disponga di più fonti di alimentazione. Non modificare o uti lizzare il cav o di alimentazione in c.a. fornito dal produttore, se non corris ...

  • Intel SR1500AL - page 155

    Intel ® Server System SR1500AL User’s Guide 133 P er il giu sto flusso dell'aria e ra ffreddamento del si stema, rimettere sempre le coper ture del telaio pr ima di riaccendere il siste ma. Operare il sistema senza le coper ture al loro proprio posto potrebbe danneggiare i co mponenti del sistema. Per rimettere le coper ture del telaio : 1. ...

  • Intel SR1500AL - page 156

    134 Intel ® Server System SR1500AL User’s Guide ...

  • Intel SR1500AL - page 157

    Intel ® Server System SR1500AL User’s Guide 135 Appendix I: Safety Inf ormation English Server Safety Inf ormation This document applies to Intel ® server boards, Intel ® server chassis (pedes tal and rack- mount) and installed peripherals. T o reduce the risk of bodily injury , electrical shock, fire, and equipment damage, read this document ...

  • Intel SR1500AL - page 158

    136 Intel ® Server System SR1500AL User’s Guide Intended Application Uses This product was evaluated as Information T echnology Equipment (ITE ), which may be installed in offices, schools, computer rooms, and similar commercial ty pe locations. The suitability of this product for other product categories and environments (such as medical, indus ...

  • Intel SR1500AL - page 159

    Intel ® Server System SR1500AL User’s Guide 137 P ower and Electrical W arnings Caution: The power button , indicated by the stand-by power marking, DOES NOT co mpletely turn off the system AC power , 5V standby power is active whenever the system is plugged in. T o r emove power fr om system, you must unplug the AC power cor d fr om the wall ou ...

  • Intel SR1500AL - page 160

    138 Intel ® Server System SR1500AL User’s Guide System Access W arnings Caution: T o avoid personal injury or pr operty damage, the following safety instruct ions apply whenever accessing the inside of the pr oduct: • T urn off all peripheral devic es connected to this pr oduct. • T urn off the system by pr essing the power button to o ff. ? ...

  • Intel SR1500AL - page 161

    Intel ® Server System SR1500AL User’s Guide 139 Electr ostatic Dischar ge (ESD) Caution: ESD can damage disk drives, boar ds, and other parts. W e r ecommend that you perform all pr ocedur es at an ESD workstation. If one is not availab le, pr ovide some ESD pr otection by wearing an antistatic wrist strap attached to chassis gr ound -- any unpa ...

  • Intel SR1500AL - page 162

    140 Intel ® Server System SR1500AL User’s Guide Deutsch Sicherheitshinweise für den Server Das vorliegende Doku ment bezieht sich auf Inte l ® Serverplatinen, Intel ® Servergehäuse (Standfuß und Rack) sowie installierte Peri pheriegeräte. Es enthält W arnungen und V orsichtsmaß na hmen zur V ermeidung von Ge fahren durch V erletzung, Str ...

  • Intel SR1500AL - page 163

    Intel ® Server System SR1500AL User’s Guide 141 Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT -Gerät getestet, da s in Büros, Schulen, Computerräumen u nd ähnlichen öf fentlichen Räumlichkeite n installiert werden kann. Die Eignung dieses Produkts für andere Einsatzb ereiche als IT (z. B. Medizin, Industrie, ...

  • Intel SR1500AL - page 164

    142 Intel ® Server System SR1500AL User’s Guide W arnungen zu Netzspannung und Elektrizität Caution: Dur ch Betätigen der mit dem S tandby-Symbo l gekennzeichneten Netztaste wir d das System NICHT vollständig vom Netz getr ennt. Es sind weiterhin 5 V aktiv , solange das System eingesteckt ist. Um das System vo llständig vom Str om zu tr enne ...

  • Intel SR1500AL - page 165

    Intel ® Server System SR1500AL User’s Guide 143 W arnhinweise für den Systemzugang Caution: Um V erletzungen und Beschädigungen zu verm eide n, sollten Sie vor Arbeiten im Pr oduktinner en folgende Sicherheitsanweis ungen beachten : • Schalten Sie alle am Produkt angeschlossenen Periphe rieg eräte aus. • Schalten Sie das System mit de m N ...

  • Intel SR1500AL - page 166

    144 Intel ® Server System SR1500AL User’s Guide Sie müssen für die gesamte Rack-Einheit eine n Netztrennschalter ein ric hte n. Dieser Netztrennschalter muß leicht zugänglich sein und über ei ne Kennzeichnung verfü gen, die besagt, daß er die S tromzufuhr zur gesamten Einheit steu ert und nich t nur zu de n Servern. Zur V ermeidung von St ...

  • Intel SR1500AL - page 167

    Intel ® Server System SR1500AL User’s Guide 145 • Prüfen Sie, ob Kabel, Erweiterun g skarten sowie weitere Komponenten ordnungsgemäß an ge bracht sind. • Befestigen Sie die Abdeckungen am Gehäus e des Produkts, wie in dessen Anleitung beschrieben. Laser-P eripher iegeräte oder -K omponenten Caution: Beachten Sie zur V ermeidung von S tr ...

  • Intel SR1500AL - page 168

    146 Intel ® Server System SR1500AL User’s Guide Domaines d’utilisation prév us Ce produit a été testé comme équipement informa tique (ITE) et peut être installé dans des bureaux, des écoles, des sall es informatiques et des endro its commerciaux similaires. L ’utilisation du présent produit dans des catégories et environnements de ...

  • Intel SR1500AL - page 169

    Intel ® Server System SR1500AL User’s Guide 147 • Dans les régions sujettes aux orages ma gnétiques, nous vous recommandons d e brancher votre système à un suppresseur de surtension et de déconnecter les lignes de télécommunication de votre modem pendant les orages. • Équipé d’une prise murale reliée à la terre. • Équipé d? ...

  • Intel SR1500AL - page 170

    148 Intel ® Server System SR1500AL User’s Guide niveaux danger eux de tension, de courant et d’ éner gie. Renvoyez-le au fabricant en cas de pr oblème. Lorsque vous remplacez un bloc d’alimentation à chaud, d ébranchez le cordon du bloc d’alimentation en cours de r emplaceme nt avant de le r etirer du serveur . Pour éviter tout risque ...

  • Intel SR1500AL - page 171

    Intel ® Server System SR1500AL User’s Guide 149 • Mettez toutes les vis ou autr es attaches de côté lorsque vous r etir ez les panneaux d’accès. Une fois que vous avez terminé d’ accéder à l’intérieur du pr oduit, r efixez le panneau d’accès avec les vis ou attaches d’origine. • N’essayez pas d’accéder à l’intérieu ...

  • Intel SR1500AL - page 172

    150 Intel ® Server System SR1500AL User’s Guide Déchar ges électr ostatiques (ESD) Attention: Les déchar ges électr ostatiques (ESD) peuvent en dommager les lecteur s de disque dur , les cartes et d’autr es pièces. Il est fortement co nseillé d’effectuer l’ensemble des pr océdur es décrites à un poste de tr avail pr otégé contr ...

  • Intel SR1500AL - page 173

    Intel ® Server System SR1500AL User’s Guide 151 P ériphériques laser Attention: P our éviter tout risque d’e xposition aux r ayonnements et/ou de domma ge pers onnel: • N’ouvr ez pas l’enceinte d’un périphérique laser . • Les périphériques laser ne sont pas réparables par l’utilisateur . • Retournez-les au fabrican t en c ...

  • Intel SR1500AL - page 174

    152 Intel ® Server System SR1500AL User’s Guide Aplicaciones y usos previstos Este producto ha sido ev aluado como equi po de tecnología informática (ITE) que pued e instalarse en oficinas, escuelas, salas de equipos informá ticos o lugares de ámbito comercial similares. Es posible que sea necesar io llevar a cabo una evaluación adicional p ...

  • Intel SR1500AL - page 175

    Intel ® Server System SR1500AL User’s Guide 153 Manipulacién del equipo Reduzca el riesgo de daños pe rsonales o en el equipo: • Respete los requisitos de sanidad y seguridad laborales de su país cuando traslade y levante el equipo. • Utilice medios mecánicos u otros que sean adecuados al trasladar o levantar el equipo. • Para que el p ...

  • Intel SR1500AL - page 176

    154 Intel ® Server System SR1500AL User’s Guide Pr ecaución: P ara e vitar descar gas eléctricas o fue go, r evise l os cables de alimentación que usará con el pr oducto tal y como se describe a continuación: • No intente modificar ni ut ilizar los cables de alimentación de CA si no son exactamente del modelo especificado para ajustarse ...

  • Intel SR1500AL - page 177

    Intel ® Server System SR1500AL User’s Guide 155 • Al r eemplazar una fuente de alimentación de conexión en fu ncionamiento, desenchufe el cable de alime ntación de la fuente de alimenta ción que va a r ee mplazar antes de extraerla del servidor . Pr ecaución: Si el servidor se ha estado ejecutando, los p r ocesador es y disipador es de ca ...

  • Intel SR1500AL - page 178

    156 Intel ® Server System SR1500AL User’s Guide disponible, pr otéjase de a lguna forma contr as las descar gas llevando u n brazalete antiestático cone ctado a la toma de tierra de la car casa (cualqui er superf icie de metal que no esté pintada) del servidor cuando manipule las piezas. Manipule siempr e las tarjetas con el máximo cuidado. ...

  • Intel SR1500AL - page 179

    Intel ® Server System SR1500AL User’s Guide 157 P erif ér icos o dispositiv os láser Pr ecaución Para evitar el riesgo de la exposición a radiaciones o de daños personales: • No abra la caja de ningún periférico o dispositivo láser • Los periféricos o dispositivos láser no pueden ser r eparado s por el usuario • Haga que el fabr ...

  • Intel SR1500AL - page 180

    158 Intel ® Server System SR1500AL User’s Guide ...

Manufacturer Intel Category Home Theater Server

Documents that we receive from a manufacturer of a Intel SR1500AL can be divided into several groups. They are, among others:
- Intel technical drawings
- SR1500AL manuals
- Intel product data sheets
- information booklets
- or energy labels Intel SR1500AL
All of them are important, but the most important information from the point of view of use of the device are in the user manual Intel SR1500AL.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Intel SR1500AL, service manual, brief instructions and user manuals Intel SR1500AL. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Intel SR1500AL.

Similar manuals

A complete manual for the device Intel SR1500AL, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Intel SR1500AL by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Intel SR1500AL.

A complete Intel manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Intel SR1500AL - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Intel SR1500AL, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Intel SR1500AL, that we can find in the current document
3. Tips how to use the basic functions of the device Intel SR1500AL - which should help us in our first steps of using Intel SR1500AL
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Intel SR1500AL
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Intel SR1500AL in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Intel SR1500AL?

Use the form below

If you did not solve your problem by using a manual Intel SR1500AL, ask a question using the form below. If a user had a similar problem with Intel SR1500AL it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)