    English Français Deutsch Italiano Español Nederlands   Türkçe IM-MC-521-E-01-03/2013 9063366-4A Digital Ear Thermometer Model Gentle T emp ® 521 Instruction Manual ...

  • Omron 9063366-4A - page 2

    1 EN Import ant Safety Information T o assu re the cor rec t use of the pr odu ct basic s afe ty measu re s should alway s be followed in clud ing the pr ecaution s liste d bel ow . Wa r n i n g: • Ind ic ates a pot enti al ly ha zar dous si tuat io n whi ch, i f no t avo ide d, coul d r esu lt in dea th or s eri ous i njur y . • C ondu cting s ...

  • Omron 9063366-4A - page 3

    2 Impo rt ant Sa fety In for matio n • D o no t to uch the infr ared s enso r wit h a finger or breath e o n it. • D o no t at tempt m ea sureme nts whe n the u nit is wet as in accurat e r eadings ma y result. • C heck t he symbol o n th e di splay befor e an d after t he m easur em ent so t hat the measu rem ent is take n in the appro pria ...

  • Omron 9063366-4A - page 4

    3 EN 1. Overview Main unit: Display: Infrared sensor Buzzer Battery icon Memory icon Probe cover icon Ear temperature Surface temperature Room temperature T emperature mode Probe Probe cap Probe cover detector Display ON/MEM button Battery cover pick hole Battery compartment Connection ring Probe cover S T A R T button ...

  • Omron 9063366-4A - page 5

    4 2. Prep aration 2 .1 Removing the Insu lating T a pe Pull the insulating t a pe out from the battery comp artme nt by catching the outer p art for the first ti me . The un it is tu rn ed on and after 1 m inu te the r oo m tem per ature will app ear o n th e display . No te s: • The room tempera tur e r em ains on the display even after the unit ...

  • Omron 9063366-4A - page 6

    2. Prep ar at ion 5 EN 2 .3 Setting the Buzzer The bu zzer is onl y av ailab le in the Ear Measur em ent Mo de . The buzzer is se t on as def ault . 1. Press the ON/MEM button to tur n on the unit. 2. Press and hold t he ON/MEM button for 3 s econds . The “ ” symbo l flas hes on the disp lay . 3. Relea se the ON/MEM butt on. The “ ” symbo l ...

  • Omron 9063366-4A - page 7

    2. Prep ar at ion 6 2 .4 Att aching a Probe Cover Alwa ys us e a ne w an d unda maged OM RON MC -EP2 p robe cove r . 1. Gently twist of f the probe cap. No te : Do n ot forcibly r emove the probe cap . 2. Place a new probe c over on the connection ring. No te : Th e a dhesive side of p robe c ove r should be upward . 3. Insert the probe into th e p ...

  • Omron 9063366-4A - page 8

    7 EN 3. Using the Unit 3 .1 T aking a Reading No te s: • Make su re the pr obe cover is attach ed correct ly . • It is reco mm ended tha t yo u mea sure 3 time s with the sam e e ar . If t he 3 m easu reme nts are differe nt, selec t th e highest tem pe rature . Ear Measurement Mode 1. Press the ON/MEM butt on. All sy mbo ls appe ar on the disp ...

  • Omron 9063366-4A - page 9

    3. Usi ng the Un it 8 Measur ing the temperature of an infant Measu ri ng on a lyi ng bab y . Meas urin g on a sittin g baby . Ligh tly s upp ort the c hild’s body . Lightl y su pport th e chil d’ s bo dy and sli ghtly pu ll the ea r towa rds the bac k. Whil e sli ght ly pu lling the ear ba ck, cove r the e xte rnal audito ry can al with the pr ...

  • Omron 9063366-4A - page 10

    3. Usi ng the Un it 9 EN 3. Press the ST ART button. The measu re ment is c omp lete in 1 sec ond with a long bee p. The display will lig ht up a nd the “ ” symb ol will flash for 5 se con ds. No te : Y o u can take an othe r mea sur ement after the disp lay ligh t tu rns off with 2 be eps. Make sure “ ” sym bol re main s lit. 4. Remove the ...

  • Omron 9063366-4A - page 11

    3. Usi ng the Un it 10 Surfa ce Mode The unit is se t in t he Ea r M eas ureme nt M ode a s defaul t . The S urfa ce M easure me nt mod e is n ot inten ded for th e body te mper atur e mea sur emen t. The surfac e m ode shows th e a ctual an d u nad justed s urfa ce tem per ature which is differe nt fro m th e bod y tem per ature. It c an h elp you ...

  • Omron 9063366-4A - page 12

    3. Usi ng the Un it 11 EN 3 .2 Using the Memory Function This unit autom atica lly stor es the res ults up to 25 se ts after e ach me asu remen t. No te : If t he memor y is fu ll, the u nit will delet e th e oldes t re adin g. 1. Press the ON/MEM button to tur n on the unit. 2. Press the ON/MEM button again. The m emory n umbe r ap pears on the di ...

  • Omron 9063366-4A - page 13

    12 4. T ro ubleshootin g an d Main tenance 4 .1 T he Icons and Err or Messa ges Error Display Cause Remed y Device stab ilization in p rocess. W a it until stops fla shin g. Pro ve cover is n ot attache d corre ctly . Attach the pr ob e cover again u ntil stops fl ashing. Battery is low . Re pla ce th e batt ery . (Re fer to s ecti on 4 .3) Measu r ...

  • Omron 9063366-4A - page 14

    4. Tro ubl esh oot in g an d M ain ten anc e 13 EN The am bien t tempe ra ture i s n ot w ithin the ran ge betw een 1 0°C and 40 °C ( 50°F - 1 04° F). All ow the t her mo meter to re st in a ro om fo r at l east 30 m inu tes a t room te mpera tur e: 10°C and 40 °C (5 0° F - 1 04° F) . Err or 5-9 , th e system is n ot funct ionin g prop er l ...

  • Omron 9063366-4A - page 15

    4. Tro ubl esh oot in g an d M ain ten anc e 14 4 .2 M aintenance • Please check th e d evice if d amage d a fter it is dro pp ed. If unsu re, please c ontact the OM RON r et a il ou tlet or distribut or for having t he dev ice ch ecke d. • The p robe i s the mo st d elicate part of the uni t . Use care w hen clean ing the Infrar ed sens or to ...

  • Omron 9063366-4A - page 16

    4. Tro ubl esh oot in g an d M ain ten anc e 15 EN 4 .3 Replacing the Batte ry Ba ttery: CR2 03 2 Lithium Butt on Batte ry No te : T o pro tect the en viron ment, disca rd the use d b atteries in a ccordan ce w ith th e local r egu lations r ega rding waste d isposa l pr ocedur e. Dispos al can be do ne at your retail store o r a t appro pr iate co ...

  • Omron 9063366-4A - page 17

    16 5. T ec hnica l Dat a Product Descri ption: Digi tal E ar Thermo meter Model: G entle T emp 521 (MC-521- E) Sen sing Unit: Thermopil e T e mperatur e Display: 4- digit, °F display in 0.1 degre e incremen ts 3-digit , °C display in 0.1 degre e increme nts Measu rement Ac curacy: Ear Measure ment Mode ± 0.2°C (± 0.4 °F) within 3 5.5°C to 42 ...

  • Omron 9063366-4A - page 18

    5. T echnical Da ta 17 EN Notes: • T he speci ficat ion may be change d wi thout pr ior notic e. • T his O MRON pr oduct is pro duc ed und er the stric t qu ality s ystem of OM RON HEAL T HCARE Co. L td., Japan. • T his device fu lfills the provisio ns o f the E C di rective 9 3 /4 2/EE C (Med ical De vice Direct ive) and the E urope an S t a ...

  • Omron 9063366-4A - page 19

    5. T echnical Da ta 18 OMRON Digi tal Ear Thermomet e r Model: Gentle T em p 521 (MC-521-E) Information for accompanying documents in the s cope o f IEC60601-1-2:2007 Important i n formation regarding Electro Magnetic Compatibility (E MC) With the increased number of el ectronic devices such as PC’ s and mobile (cellul ar) telephones , medical de ...

  • Omron 9063366-4A - page 20

    19 EN 6. Some Useful Information 6 .1 T emperature mea suremen t s t aken within the ear The Ge ntle T em p 521 Digital E ar Th erm omete r d etects the infr ared h eat give n off by the ea rdrum an d s urrou nding tiss ues, an d it c onverts this hea t into a n e quivalen t ea r temp era ture. The Gentle T em p 521 is less threat enin g to a child ...

  • Omron 9063366-4A - page 21

    6. Some Us eful In form atio n 20 As a mbi ent temp er ature, sw eat, or sa liva ea sily affects body temper atu re mea sure d unde r th e arm o r th e ton gue , re adin gs ma y be l owe r than the cor e temp era tur e. T ympan ic te mpera tur e mea sur eme nt accu ra tely r eflec ts the brain tem per ature an d can lead to a qu icker detect ion o ...

  • Omron 9063366-4A - page 22

    6. Some Us eful In form atio n 21 EN 6 .3 Ear temp erature c omp ared to other types of b ody temperatu re The no rmal te mp eratur e va ries acco rd ing to d ifferent loca tions on the body . 6 .4 Questions and ans wers How many tim es can I measur e conse cutivel y? Y ou can me asu re con secu tively up t o th ree tim es. The m ain unit will the ...

  • Omron 9063366-4A - page 23

    6. Some Us eful In form atio n 22 Is the te mperature m easured in th e right ea r different from tha t measu red in the lef t ear? Am ong he alth y people , th ere sho uld be no sig nifica nt differenc e in t he m easur em ent resu lts. Differenc es may b e cau sed by t he fo llo win g rea son s: 1) The in fra red se nsor is not in serted in t he ...

  • Omron 9063366-4A - page 24

    Manufacturer EU-representative OMRON HEAL THCARE Co., Ltd. 53, Kunotsubo, T erado-cho, Muko, Kyoto, 617-0002 JAP AN OMRON HEAL THCARE EUROPE B.V . Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www .omron-healthcare.com OMRON HEAL THCARE UK L TD. Opal Drive, Fox Milne, Milton Keynes, MK15 0DG, U.K. OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH Gott ...

Manufacturer Omron Category Thermometer

Documents that we receive from a manufacturer of a Omron 9063366-4A can be divided into several groups. They are, among others:
- Omron technical drawings
- 9063366-4A manuals
- Omron product data sheets
- information booklets
- or energy labels Omron 9063366-4A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron 9063366-4A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron 9063366-4A, service manual, brief instructions and user manuals Omron 9063366-4A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron 9063366-4A.

Similar manuals

A complete manual for the device Omron 9063366-4A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron 9063366-4A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron 9063366-4A.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron 9063366-4A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron 9063366-4A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron 9063366-4A, that we can find in the current document
3. Tips how to use the basic functions of the device Omron 9063366-4A - which should help us in our first steps of using Omron 9063366-4A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron 9063366-4A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron 9063366-4A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron 9063366-4A?

Use the form below

If you did not solve your problem by using a manual Omron 9063366-4A, ask a question using the form below. If a user had a similar problem with Omron 9063366-4A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)