    For Integral Blower Installations: • Requires Integral Blower: Model # VTN600CVA • Requires Round Duct Size (6" Diam.) • Requires Dedicated Branch Cir cuit P ow er Supply • 120 V olt A C• min. 15 Amps., 3 prong receptacle • 60 Hz. • See Steps 3 and 5 for electrical receptacle and duct outlet location For Remote Blower Installatio ...

  • Thermador UCV30 - page 2

    SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS A . Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-related construction. B . Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipme ...

  • Thermador UCV30 - page 3

    Figure 1 Snorkel Filters Suppor t Leg J-Box T op Cap Blower Assembly Wing Nuts INTRODUCTION GENERAL DESCRIPTION The complete Universal Cook‘n‘Vent ® System consists of the ventilator intake and a blower . See Fig. 1. The blower is either an integral (mounted on the vent intake in the cabinet under the cooktop) or a remote (roof or outside wall ...

  • Thermador UCV30 - page 4

    STEP 1 PLAN THE INSTALLATION Carefully follow the planning procedures listed below. See Figure 2. A . Determine whether a remote or integral blower will be used. Remote blower installation requires 5 wires plus a ground wire to run from the Cook‘n’Vent ® to the blower. B. Make sure adequate cabinet and counter space has been provided for unit ...

  • Thermador UCV30 - page 5

    Figure 2 • Be certain to avoid interference with gas and electric supply to cooktop . • Shelving and dra w er depths are dependent upon cooktop depth and setback. Page 4 10-3/8" 8-1/16" 1 2" 1 1 " 1 1 " 10" A B INTEGRAL REMOTE w/ CVT314 REMOTE w/ CVT7 ...

  • Thermador UCV30 - page 6

    FIGURES 3 THR OUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING Figure 3 THROUGH W ALL INST ALLA TION Figure 4 INTEGRAL BLO WER VTN600CVA Ground 12" Min. Wall Cap WC8 Figure 5 THROUGH WALL DUCT INSTALLATION INTEGRAL BLO WER VTN600CVA BLO WER RO T A TED 90° FOR SIDE CONNECTION THROUGH W ALL INST ALLA TION Figure 6 REMO TE BLO WER Duct Attachment Box CVT ...

  • Thermador UCV30 - page 7

    Page 6 ...

  • Thermador UCV30 - page 8

    T ABLE 2. DUCT W ORK INST ALLA TION GUIDELINES • Keep duct runs as short and straight as possible. • Duct fittings (elbows and transitions) reduce air flow efficiency. • Back to back elbows and "S" turns significantly reduces air flow and are not recommended. • A short straight length of duct at the inlet of the remote blower give ...

  • Thermador UCV30 - page 9

    Figure 7 TABLE 3 (in inches) UCV30/36/45 INSTALLATION DIMENSIONS WITH THERMADOR COOKTOPS Table 3 Notes * Dimension "SB" is the minimum distance from the leading edge of the counter to the leading edge of the cutout. + + Dimension "BT" is the thickness of back-splash that provides 1 / 8 " clearance between vent and backsplas ...

  • Thermador UCV30 - page 10

    I NSTALLATION WITH OTHER COOKTOPS WHERE SPECIFIED (SEE PART B) Figure 8 34-1/2" - UCV36 OW CW 28-1/2" - UCV30 1/8" OD CD SB 2-1/4" BT 43-1/2" - UCV45 The installer will need to have the cooktop installation instructions available to complete the installation. All cooktop dimensions should be verified through measure- ment p ...

  • Thermador UCV30 - page 11

    STEP 3 PREPARE DUCT CUTOUTS IN CABINET T ABLE 4 INTEGRAL BLOWER VTN600CVA C D E F G H UCV30 7-1/2 6 1/ 4 15-1/2 9 - UCV36 7-1/2 6 1/ 4 15-1/2 9 - UCV45 7-1/2 6 1/ 4 15-1/2 9 - REMOTE BLOWER VTR600R OR VTR1000Q C D E F G H UCV30 7-1/4 6 - 12-1/4 12-1/4 3 UCV36 7-1/4 6 - 12-1/4 12-1/4 3 UCV45 7-1/4 6 - 12-1/4 12-1/4 3 Page 10 A . Refer to Figure 9. D ...

  • Thermador UCV30 - page 12

    STEP 6 MOUNT VENT & COOKT OP A. Remove grease filters and any packing materials from inside the intake. B. Set the vent intake into rear of countertop opening. Carefully lower it into position so that the flanges on the rear sides and edges fully support the unit hanging from the countertop. C Loosely fasten lower support legs to vent. Hold the ...

  • Thermador UCV30 - page 13

    STEP 7 MOUNT INTEGRAL BLOWER OR Remote Blower Transition MOUNT INTEGRAL BLOWER OR Remote Blower Transition Integral Blower VTN600CVA Only A. Place blower in front of intake inside of cabinet, take conduit and blower wires and guide them towards the right at the floor of the cabinet. B. On each side of blower housing there is a flanged edge. When pl ...

  • Thermador UCV30 - page 14

    STEP 8 VERIFY INSTALLATION, OPERA TION & COOKT OP ALIGNMENT Before performing this procedure, verify that all packing materials were removed from inside the lower enclosure front and that the grease filters have been properly installed. Refer to the Care and Use Manual for instructions regarding filter instal- lation. Plug the vent power cord i ...

  • Thermador UCV30 - page 15

    NO TES ...

  • Thermador UCV30 - page 16

    5551 McFadden Aven ue, Huntington Beach C A, 92649 • 800-735-4328 BSH Home Appliances Corp. • Litho in U.S.A. 10/02 5060004249 (8209) ...

Manufacturer Thermador Category Cooktop

Documents that we receive from a manufacturer of a Thermador UCV30 can be divided into several groups. They are, among others:
- Thermador technical drawings
- UCV30 manuals
- Thermador product data sheets
- information booklets
- or energy labels Thermador UCV30
All of them are important, but the most important information from the point of view of use of the device are in the user manual Thermador UCV30.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Thermador UCV30, service manual, brief instructions and user manuals Thermador UCV30. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Thermador UCV30.

Similar manuals

A complete manual for the device Thermador UCV30, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Thermador UCV30 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Thermador UCV30.

A complete Thermador manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Thermador UCV30 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Thermador UCV30, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Thermador UCV30, that we can find in the current document
3. Tips how to use the basic functions of the device Thermador UCV30 - which should help us in our first steps of using Thermador UCV30
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Thermador UCV30
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Thermador UCV30 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Thermador UCV30?

Use the form below

If you did not solve your problem by using a manual Thermador UCV30, ask a question using the form below. If a user had a similar problem with Thermador UCV30 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)