Manual Bryant 280ANV

18 pages 2.1 mb
Download

Go to site of 18

Summary
  • Bryant 280ANV - page 1

    280ANV EVOLUTI ON R EXTREME V ARIABLE SP EED HEA T PUMP WITH PURON r REFR IGERANT (2 - - 5 T on) Installation Instructions NOTE : Read the en tire in structio n manu al b efo re starting the in stallatio n. T ABLE OF CONTENTS PA G E N O . SAFETY CONSIDERA TI ONS 2 ................................................................... INST ALLA TION RE ...

  • Bryant 280ANV - page 2

    2 Inf or ma ti on in t he se ins t al l at ion ins t ruc t ions per ta i ns only t o 280ANV se r ie s uni ts . SAF ETY CONSIDERA TI ONS Imp ro per installatio n , adju stmen t, alteration , service, m ain tenan ce, or use ca n ca us e explos i on, fi re , el ec t ri c al s hoc k, or other condi t ions w hic h ma y ca us e de a t h, per s onal inj u ...

  • Bryant 280ANV - page 3

    3 In stal la tion Reco mmend ati on s In som e cases n o ise in the living area has been traced to g as puls a ti ons f rom im prope r i nst a ll a ti on of equi pment . 1. Loca te unit awa y from windows , pati os , dec ks , etc . whe re unit oper at i on sound m ay di s tur b c ust ome r . 2. In n o ise sen sitive ap p lication s (su ch as b ed r ...

  • Bryant 280ANV - page 4

    4 Step 2 — In stal l o n a S oli d , L evel Mou n tin g Pa d If c ondi ti ons or loc a l code s r equi r e the uni t be at ta c hed to pad, ti e down bolt s shoul d be us e d a nd fa s te ne d thr ough knoc kouts provi de d in uni t ba s e pan. Ref e r t o uni t mount ing pa t te r n i n Fi g. 3 to det e rmi ne ba s e pan si z e and knockout hol ...

  • Bryant 280ANV - page 5

    5 Ste p 7 — Make P iping Conne ct ions ! W ARNING PERSONAL INJUR Y AND UNIT DAM AGE HAZARD Fai l ure t o fol l ow thi s wa rni ng could r e s ult i n per s onal i njur y or death . Rel i eve pr e ss ur e and re c over a ll re fr i ger a nt bef ore sys te m re pa ir or f i nal uni t di spos a l. U se a l l se r vic e por ts and open al l fl ow- - ...

  • Bryant 280ANV - page 6

    6 Outdoor Unit Connected to Fac tory - - App roved Ind oor Unit Outdoor uni t c onta i ns c orr e ct s ys te m re f ri ge ra nt c har ge f or oper a ti on wit h fa c tor y- - approve d, AHRI- - ra te d s ma ll e st i ndoor uni t whe n conne c te d by 15 f t. (4.57 m) of fi e ld- - suppli e d or factory - - accesso ry tu bin g , and facto ry - - s u ...

  • Bryant 280ANV - page 7

    7 500 MINUTES 0 1 23 4 5 67 1000 1500 LEAK IN SYSTEM V ACUUM TIGHT TOO W E T TIGHT DR Y SYSTEM 2000 MICRONS 2500 3000 3500 4000 4500 5000 A95424 A95424 Fig . 7 - - Deep V acu um Gra p h Fi nal T ubi ng Ch eck IMPOR T ANT : Chec k t o be c e r ta in f a ct or y tubi ng on both indoor and outdoor uni t has not shif t ed duri ng s hi pme nt. Ens ure t ...

  • Bryant 280ANV - page 8

    8 Step 10 — In sta ll Acces so ries Th ere are n o refrig eratio n circu it or electrical accesso ries req uired or availab le for installatio n with in the un it. E x ternal to th e u nit, th e same accesso ries su ch as the liq u id line so len o id, s upport f e et , snow r ac k, wi nd baf f le et c ., a r e avai l abl e on o the r Br yant uni ...

  • Bryant 280ANV - page 9

    9 Crankcase Heater Operat ion Th is u nit h as an in ternal cran k case heater that will b e energized du rin g the off cycle and is in tellig ently d eman d ed b y th e sy stem to pre ve nt the c ompr e ss or f rom bei ng the col de st par t of the s yst e m thu s en han cin g t he reliab ility. Th e cran kcase h eater w ill fu nctio n as ne e de ...

  • Bryant 280ANV - page 10

    10 Th e co n tro l b o ard accum u lates com presso r run tim e. A s th e accum u lated run tim e appro ach es the selected defrost in terval time, the c ont rol boa r d monit ors t he c oil t em per a tur e s ens or f or a def ros t dem and . If a d efro st d eman d ex ists, a d efro st cy cle w ill be in itiated at the en d of th e selected time ...

  • Bryant 280ANV - page 11

    11 0 50 100 150 200 250 300 350 400 0 1 02 03 04 05 06 0 V apor Service V alve Pressure Suction Pressure For use in Heating Charging Mode only Heating Check Chart - 280ANV024/036 See user interface set in Charging Mode Charging In Cooling Mode - 280ANV024/036 (-18ºC) (-12ºC) (-10ºC) (-7ºC) (4ºC) (10ºC) (16ºC) Outdoor Ambient T emperature ºF ...

  • Bryant 280ANV - page 12

    12 MAJOR COMPONENTS V ariab le speed C on tr ol Board The HP cont rol boa rd cont r ols t he fol l owing func t ions : S Co mp resso r sp eed S Conta c tor ope r at i on S Outdoor f a n motor ope ra t ion S Reve r si ng valve ope r at i on S Defro st op eratio n S Lo w am bien t co o ling S Cran k case heater o peratio n S Pressu re sw itch m on it ...

  • Bryant 280ANV - page 13

    13 Pres s ur e Swit ch Pro tection The outdoor unit is e quippe d wi th high pr es s ure s wi tc h. If t he cont r ol se ns es the openi ng of a high pres s ure s wi tc h, it wil l re s pond as fol l ows : 1. D e - - en ergize th e co ntacto r . 2. Kee p the outdoor fa n oper a ti ng f or 15 mi nut es . 3. Dis pla y the a ppropr i at e f aul t code ...

  • Bryant 280ANV - page 14

    14 Outd oo r Coil T hermis tor The outdoor c oi l ther mi st or i s a 10Kohm r es i st or us ed for mu ltiple system o peratio n s. It pro v id es the co il/liq uid lin e temp erature to the h eat p um p b o ard an d user in terface. Lo w amb ient o p eration , defro st in itiatio n, d efro st terminatio n and assistan ce w ith OA T te mpe r at ur ...

  • Bryant 280ANV - page 15

    15 Stat us Codes T abl e 7 shows t he st a tus c ode s fl a she d by the ambe r s ta t us l i ght. Mos t s ys te m pr obl ems ca n be diagnos e d by re a di ng t he sta t us code as fl as he d by t he a mbe r sta t us l ight on the cont rol boar d. The code s a re f l as he d by a se r ie s of s hort a nd long fl a she s of the status lig h t. T h ...

  • Bryant 280ANV - page 16

    16 CB MODEL PL8 FORCED DEFROST J2 1 BRN RED SEC1 SEC2 PWM2 PWM1 INVERTER PL1 PL2 RVS CC PL1 1 PL4 PL6 OCT OA T SPT OST A B C NO USE UTIL LS Y C O COMM ST A TUS YEL BLU EXV PL5 PL3 HPS Utility Inter face* A11544 Fig. 20 - - V ariabl e Spe ed Contr ol Board with op tion a l Utility Rela y CB MODEL PL8 FORCED DEFROST J2 1 BRN RED SEC1 SEC2 PWM2 PWM1 I ...

  • Bryant 280ANV - page 17

    17 T a ble 7 – T roubl esho oti ng F AUL T DESCRI PTIO N SEN T TO UI FLASH COD E (AMBE R LED ) RESET TI ME (minut es) --- --- St andby ON, no f la sh --- --- Va r ia b le C a p ac i ty or E m e r g e n c y Mode 1, p ause --- --- V ariabl e Spee d Range Cutback 1( 2s e cO N ) ,l o n g e rp a u s e ( 1 second O FF) Communi cat ions L oss 16 NA Inva ...

  • Bryant 280ANV - page 18

    18 FINAL CHECKS IMPOR T ANT : IMPOR T ANT : Bef or e le a ving job, be sure to do th e follo win g : 1. E n sure th at all wirin g is ro u ted aw ay from tu b in g and s hee t me ta l e dge s to pre vent r ub- - through or wir e pi nchi ng. 2. Ensur e t ha t a l l wi r ing a nd tubi ng i s s e cur e in unit bef or e a ddi ng pane l s a nd c ove rs ...

Manufacturer Bryant Category Heat Pump

Documents that we receive from a manufacturer of a Bryant 280ANV can be divided into several groups. They are, among others:
- Bryant technical drawings
- 280ANV manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 280ANV
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 280ANV.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 280ANV, service manual, brief instructions and user manuals Bryant 280ANV. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 280ANV.

Similar manuals

A complete manual for the device Bryant 280ANV, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 280ANV by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 280ANV.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 280ANV - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 280ANV, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 280ANV, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 280ANV - which should help us in our first steps of using Bryant 280ANV
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 280ANV
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 280ANV in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant 280ANV?

Use the form below

If you did not solve your problem by using a manual Bryant 280ANV, ask a question using the form below. If a user had a similar problem with Bryant 280ANV it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)