  • Pelco WCS1-4 - page 1

    WCS1-4 Environmental Power Supply C561M-E (8/05) ® INST ALLA TION/OPERA TION ...

  • Pelco WCS1-4 - page 2

    2 C561M-E (8/05) IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified service personnel and conform to all local codes. 6. Use only installation methods and materials capable of supporting four times the maximum ...

  • Pelco WCS1-4 - page 3

    C561M-E (8/05) 3 DESCRIPTION The WCS1-4 is a mutliple power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra ® and Esprit ® . The WCS1-4 is capable of powering up to four units and can handle pan/tilt, heater , blower , and camera operation. The WCS1-4 ...

  • Pelco WCS1-4 - page 4

    4 C561M-E (8/05) INST ALLA TION MOUNTING INSTRUCTIONS To mount the power supply directly to a wallboard, wall, or concrete refer to Figures 1 through 3 and do the following: 1. Remove the retaining screw from the door latch of the WCS1-4 power supply . 2. Open the door of the WCS1-4 power supply , and then remove the plug(s) from the required condu ...

  • Pelco WCS1-4 - page 5

    C561M-E (8/05) 5 FUSE INST ALLA TION The WCS1-4 power supply is shipped from the factory with a 1.6-amp fuse installed for 100/120 V AC input power . T o use input power of 240 VAC, change the 1.6-amp fuse to a 500-milliamp fuse (supplied). To change the fuse remove the lid to the fuse holder (refer to figure 4) located inside the power supply and ...

  • Pelco WCS1-4 - page 6

    6 C561M-E (8/05) OUTPUT WIRING To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to T able A and determine the output connection needed for your camera, dome, or positioning system. Refer to Figure 4, for the proper connector strip connections. 2. Attach one output wire to eith ...

  • Pelco WCS1-4 - page 7

    C561M-E (8/05) 7 CABLE CONNECTIONS AND REQUIREMENTS Table A. Wiring Distances The following are the recommended maximum distances to wire the WCS1-4 to a Spectra III or Esprit positioning system. To determine the correct voltage tap: 1. Pick the unit type. 2. Find the wire gauge used (22 gauge is not recommended). 3. Determine which secondary outpu ...

  • Pelco WCS1-4 - page 8

    8 C561M-E (8/05) MAINTENANCE There are no user -serviceable parts except for the fuse. If the transformer in the WCS1-4 does not work properly , the entire environmental power supply needs to be returned to the factory for repair . Refer to the Wa rranty and Return Information for instructions on returning the WCS1-4. Clean the outer surface of the ...

  • Pelco WCS1-4 - page 9

    C561M-E (8/05) 9 SPECIFICA TIONS ELECTRICAL Input V oltage: Selectable 100, 120, 240 V AC, 50/60 Hz via the Primary Line Input connector strip Output V oltage/Power: Selectable 24 V AC (T ap A), 26 VAC (T ap B), or 28 VAC (T ap C) at 100 V A via the Secondary Output T ap’ s connector strip Fusing: One fuse. Select from one of the following suppli ...

  • Pelco WCS1-4 - page 10

    10 C561M-E (8/05) Figure 5. WCS1-4 Dimension Drawing NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES. 6.50 (16.51) 5.63 (14.30) 4.50 (11.43) 6.44 5.88 (14.94) 4.00 (10.16) 7.88 (20.02) (16.36) ...

  • Pelco WCS1-4 - page 11

    C561M-E (8/05) 11 W ARRANTY AND RETURN INFORMA TION ® Pelco, the Pelco logo, Spectra, Genex, Coaxitron, Legacy , Esprit, Camclosure, Spectra III, and Spectra III SE are registered trademarks of Pelco. © Copyright 2003, Pelco. All rights reserved. REVISION HISTORY Manual # Date Comments C561M 11/97 Original version. C561M-A 12/98 Changed model num ...

  • Pelco WCS1-4 - page 12

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada Singapore ® ...

Manufacturer Pelco Category Video Gaming Accessories

Documents that we receive from a manufacturer of a Pelco WCS1-4 can be divided into several groups. They are, among others:
- Pelco technical drawings
- WCS1-4 manuals
- Pelco product data sheets
- information booklets
- or energy labels Pelco WCS1-4
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pelco WCS1-4.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pelco WCS1-4, service manual, brief instructions and user manuals Pelco WCS1-4. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pelco WCS1-4.

Similar manuals

A complete manual for the device Pelco WCS1-4, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pelco WCS1-4 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pelco WCS1-4.

A complete Pelco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pelco WCS1-4 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pelco WCS1-4, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pelco WCS1-4, that we can find in the current document
3. Tips how to use the basic functions of the device Pelco WCS1-4 - which should help us in our first steps of using Pelco WCS1-4
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pelco WCS1-4
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pelco WCS1-4 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pelco WCS1-4?

Use the form below

If you did not solve your problem by using a manual Pelco WCS1-4, ask a question using the form below. If a user had a similar problem with Pelco WCS1-4 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)