  • Lucent Technologies 61227A - page 1

    Lucent Technologies Bell Labs Innovations CIB 3140 (533B) Memory Module (61227A) (106433691) CIB 3140 Comcode 106433691 Issue 2 January 1997 ...

  • Lucent Technologies 61227A - page 2

    Memory Modul e When installed in the MERLIN ® Plus system control unit, this memory module (Figure 1) upgrades your system to the MERLIN Plus Communi- cations System Release 2. MEMORY MODULE Figure 1 MERLIN Plus Communications System Release 2 Memory Module The new system features available with this memory module are listed below. For further inf ...

  • Lucent Technologies 61227A - page 3

    NOTE: This memory module also houses a battery that preserves all programming for at least four days in case of a power failure. In addition, a 450F adapter is included to provide a connection between the control unit and the Data Collector, and to allow the Data Collector and the Busy Buster feature to share the same jack on the voice terminal mod ...

  • Lucent Technologies 61227A - page 4

    Loosened screw Removing the Front and Top Covers From the control Unit 4 5 6 7 Figure 2 To Insert the new memory module, first grasp its plastic handle on the front and align the four pin guides at each corner of the module with the rectangular opening at the top of the control unit (Figure 3). Push the module in until the gold pins insert fully in ...

  • Lucent Technologies 61227A - page 5

    Memory module Figure 3 Inserting and Removing the Memory Module 8 Plug the power cord back into the outlet and set the power switch on the control unit to On. 9 Replace the front cover on the control unit. Remember, you will have to readminister and reprogram your sets as described in Section 3, "Administering the System," of your new Sys ...

  • Lucent Technologies 61227A - page 6

    Customer Administerable Timer The Customer Administerable Timer is used in conjunction with the Call Forwarding and Remote Line Access features. The timer disconnects calls made via Call Forwarding and/or Remote Line Access after these calls reach a system-wide call duration limit. The Customer Administerable Timer can be set to a value of from 1 t ...

  • Lucent Technologies 61227A - page 7

    Lucent Technologies Bell Labs Innovations Copyright © 1996, Lucent Technologies All Rights Reserved Printed in U.S.A. ...

Manufacturer Lucent Technologies Category Computer Hardware

Documents that we receive from a manufacturer of a Lucent Technologies 61227A can be divided into several groups. They are, among others:
- Lucent Technologies technical drawings
- 61227A manuals
- Lucent Technologies product data sheets
- information booklets
- or energy labels Lucent Technologies 61227A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lucent Technologies 61227A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lucent Technologies 61227A, service manual, brief instructions and user manuals Lucent Technologies 61227A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lucent Technologies 61227A.

A complete manual for the device Lucent Technologies 61227A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lucent Technologies 61227A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lucent Technologies 61227A.

A complete Lucent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lucent Technologies 61227A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lucent Technologies 61227A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lucent Technologies 61227A, that we can find in the current document
3. Tips how to use the basic functions of the device Lucent Technologies 61227A - which should help us in our first steps of using Lucent Technologies 61227A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lucent Technologies 61227A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lucent Technologies 61227A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lucent Technologies 61227A?

Use the form below

If you did not solve your problem by using a manual Lucent Technologies 61227A, ask a question using the form below. If a user had a similar problem with Lucent Technologies 61227A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)