  • National Instruments cFP-DO-403 - page 1

    FIELDPOINT ™ OPERATING INSTRUCTIONS AND SPECIFICATIONS FP-DO-403 and cFP-DO-403 16-Channel, 5 to 30 V Sinking Digit al Output Module These operating instructions descri be ho w to install and use the National Instruments FP-DO-403 a nd cFP-DO-40 3 digital output modules, referred to inclusi v ely as the [c]FP-DO-403. F or information about config ...

  • National Instruments cFP-DO-403 - page 2

    [c]FP-DO-403 2 ni.com 2. Align the FP-DO-403 alignment slots with the guide rails o n the terminal base. 3. Press firmly to seat the FP-DO-403 on the terminal base. When the module is firmly seated, the te rminal base latch locks it into place. Figure 1. Installing the FP-DO-403 Installing the cFP-DO-403 The cFP-DO-403 mounts on a Compact FieldPoin ...

  • National Instruments cFP-DO-403 - page 3

    © National Instruments Corp. 3 [c]FP-DO-403 Figure 2. Installing the cFP-DO-403 Wiring the [c]FP-DO-403 The FP-TB- x terminal base has conne ctions for each FP-DO-403 output channel and for an external supply to po wer field devices. The cFP-CB- x connector block provides the same connections for the cFP-DO-403. Each channel has one output termina ...

  • National Instruments cFP-DO-403 - page 4

    [c]FP-DO-403 4 ni.com loads on the output channels, up to 2 A per channel. 1 Connect the external po wer supply to multiple V and V SUP terminals and to multiple C and COM terminals as need ed to ensure that the maximum current through any terminal is 2 A or less. Install a 2 A maximum, fast-act ing fuse (F2A 250V) between the external po wer suppl ...

  • National Instruments cFP-DO-403 - page 5

    © National Instruments Corp. 5 [c]FP-DO-403 Figure 3. Wiring for Low-Current Applica tions Wiring for High-Current Applications If your application requires more than 2 A combined current through all channels of the [c]F P-DO-403, wire your application as shown in Figure 4. Install a 2 A maximum, f ast-acting fuse (F2A 250V) in series with each lo ...

  • National Instruments cFP-DO-403 - page 6

    [c]FP-DO-403 6 ni.com Digital Output Circuit The [c]FP-DO-403 digital output ch annels are optically isolated from the rest of the FieldPoint bank . In the ON state, a transistor is turned on between the V OUT terminal and the ex ternal supply (the C and COM terminals). In the OFF stat e, this transistor is turned of f, allowing only a smal l leaka ...

  • National Instruments cFP-DO-403 - page 7

    © National Instruments Corp. 7 [c]FP-DO-403 mount the flyback diode within 18 in. of the load. Figure 5 shows a flyback diode connected to an inductiv e load. Figure 5. Connection to Inductive Load with Flyback Diode Although the [c]FP-DO-403 contains flyback diodes to pre vent excessi vely high voltage from damaging the module, National Instrumen ...

  • National Instruments cFP-DO-403 - page 8

    [c]FP-DO-403 8 ni.com 250 V rms Measurement Cate gory II contin uous isolation, ve rified by 2,300 V rms , 5 s dielectric withst and test. The [c]FP-DO-403 provides double insulation (compliant with IEC 61010-1) for working v oltages of 250 V rms 1 . Safety standards (such as those published by UL and IEC) requir e the use of double insulation betw ...

  • National Instruments cFP-DO-403 - page 9

    © National Instruments Corp. 9 [c]FP-DO-403 •D o not use the [c]FP-DO-403 as the only isolating barrier between human cont act and working v o ltages higher than 250 V rms . • Operate the [c]FP-DO-403 only at or belo w Pollution Degree 2. Pollution De gree 2 means that only nonconductive pollution occurs in most case s. Occasionally , ho wever ...

  • National Instruments cFP-DO-403 - page 10

    [c]FP-DO-403 10 ni.com Caution For Zone 2 applications, install a protection device across the e xternal power supply and the COM terminal. The device must pre vent the external po wer supply voltage from e xceeding 42 V if there is a transient ov ervoltage conditi on. Special Conditions for Hazard ous Locations Use in Europe The [c]FP-DO-403 has b ...

  • National Instruments cFP-DO-403 - page 11

    © National Instruments Corp. 11 [c]FP-DO-403 Power Requirements Power from network module ............ 600 mW Safety Isolat ion Voltage Isolation voltage is v erified by a dielectric withstand te st. Channel to ground Continuous .............. ......... .......... 250 V rms , Measurement Category II Dielectric withstand... ......... ........ 2 ,30 ...

  • National Instruments cFP-DO-403 - page 12

    [c]FP-DO-403 12 ni.com Safety This product is designed to meet the requirements of the following standards of safety for electric al equipment for measurement, control, and laboratory use: • IEC 61010-1, EN-61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certif ications, refer to the product label or visit ni.com/certification , ...

  • National Instruments cFP-DO-403 - page 13

    © National Instruments Corp. 13 [c]FP-DO-403 contains the en vironmental regulat ions and directi v es with which NI complies, as well as othe r en vironmental information not included in this document. Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of their lif e cycle, all products must be sent to a WEEE re c ycling cen ...

  • National Instruments cFP-DO-403 - page 14

    [c]FP-DO-403 14 ni.com Where to Go for Support For more information about settin g up the FieldPoint system, refer to these National Instruments documents: • FieldPoint network module user manual • Other FieldPo int I/O m odule operating instructions • FieldPoint terminal base and connector block operating instructions Go to ni.com/support fo ...

  • National Instruments cFP-DO-403 - page 15

    © 2002–2007 Nati onal Instruments Corp. All rights reserved. 373354C-01 Aug07 National Instruments, NI, n i.com, and LabVIEW are trademarks of National I nstruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments tra demarks. Other product and company names ment ioned herein are trad ...

Manufacturer National Instruments Category Network Router

Documents that we receive from a manufacturer of a National Instruments cFP-DO-403 can be divided into several groups. They are, among others:
- National Instruments technical drawings
- cFP-DO-403 manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments cFP-DO-403
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments cFP-DO-403.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments cFP-DO-403, service manual, brief instructions and user manuals National Instruments cFP-DO-403. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments cFP-DO-403.

A complete manual for the device National Instruments cFP-DO-403, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments cFP-DO-403 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments cFP-DO-403.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments cFP-DO-403 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments cFP-DO-403, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments cFP-DO-403, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments cFP-DO-403 - which should help us in our first steps of using National Instruments cFP-DO-403
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments cFP-DO-403
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments cFP-DO-403 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments cFP-DO-403?

Use the form below

If you did not solve your problem by using a manual National Instruments cFP-DO-403, ask a question using the form below. If a user had a similar problem with National Instruments cFP-DO-403 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)