  • Konica Minolta PULSOX-300 - page 1

    OXYGEN SA TURA TION MONITOR PULSOX -300 ® Instruction Manual This instrument must be used according to the instructions of the doctor . ...

  • Konica Minolta PULSOX-300 - page 2

    Safety Symbols W arnings and precautions noted in this manual and the instrument are indicated by the following markings, designed to prevent accidents caused by erroneous handling of the equipment. This indicates text consisting of a warning or precaution relating to safety . Please read the text carefully and use the equipment safely . This indic ...

  • Konica Minolta PULSOX-300 - page 3

    1 Foreword Safety Precautions T o ensure correct use of this instrument, read the following points carefully and adhere to them. After you have read this manual, keep it in a safe place where it can be referred to anytime a question arises. W ARNING (Failure to adhere to the following points may result in death or serious injury .) The instrument i ...

  • Konica Minolta PULSOX-300 - page 4

    2 Foreword CAUTION (Failure to adhere to the following points may result in injury or damage to the in- strument or other property .) Do not use batteries other than those specified by KONICA MINOL T A SENSING, INC. When installing batteries in the instrument, make sure that they are correctly oriented according to the mark. If alkali uid from t ...

  • Konica Minolta PULSOX-300 - page 5

    3 Foreword Contents Safety Symbols Safety Precautions ............................................................. 1 Foreword ............................................................................4 Safety Notes ........................................................................... 4 Package Contents...................................... ...

  • Konica Minolta PULSOX-300 - page 6

    4 Foreword Foreword Safety Notes CAUTION: U.S.Federal law restricts this device to sale by or on the order of a physician. The instrument is designed for measurement of the oxygen saturation (SpO 2 ) of arterial blood and the pulse rate. Do not use it for any other purposes, such as warning of sleep apnea and breathing abnormalities. The Oxygen Sat ...

  • Konica Minolta PULSOX-300 - page 7

    5 Foreword Package Contents Before using the instrument, make sure that the following items are present. 1) PULSOX-300 main body × 1 2) Wristband WB-300 × 1 3) AAA-size alkaline battery × 1 4) Instruction manuals • PULSOX-300 instruction manual × 1 • Separate manual (Using manual for Probes) × 1 ✻ The probe is optional. About Probe The f ...

  • Konica Minolta PULSOX-300 - page 8

    6 Foreword System Diagrams and Accessories The instrument consists of the following items. 05,3/ 8 Optional accessories Standard accessories Wristband WB-300 AAA-size alkaline battery Finger Clip Probe SR-5C Spot Check Probe SP-5C Monitor Probe LM-5C Personal Probe SD-5C Extension cable EC-300 Standard accessories Optional accessories ...

  • Konica Minolta PULSOX-300 - page 9

    7 Foreword Names of Parts PULSOX-300 Power button Probe connector Wristband Battery cover Used to start/end measurement. Measurement results and messages are displayed. Connect the probe to this connector . Used to set the instrument on your wrist. The cover can be opened by turning it approximately 90 degrees. Display (LED) ...

  • Konica Minolta PULSOX-300 - page 10

    8 Foreword Notes on Use • This instrument should be used under the following operat - ing conditions. • T emperature of 0 to 40°C (32 to 104°F), relative humidity of 30 to 85%, with no condensation. • Atmospheric pressure of 700 to 1060 hPa (altitude of – 400 to 3000m). • This is a precision instrument. T o avoid the possibility of it b ...

  • Konica Minolta PULSOX-300 - page 11

    9 Foreword Differenc e f ro m t he SaO 2 value to displayed value <T able 1> <T able 2> SaO 2 HbCO SaO 2 Methemoglobin 1% 5% 10% 1% 5% 10% 50 50 70 70 90 90 100 100 Measured value is always lower than th e a ctual value. Displayed value is sometimes higher than th e a ctual value if SaO 2 is around 50%. -0.1 -0.7 -1.5 +0.2 +1.3 +3.2 -0. ...

  • Konica Minolta PULSOX-300 - page 12

    10 Foreword Notes on Storage • This instrument should be stored under the following storage conditions. • T emperature of –10 to 60°C (14 to 140°F), relative humid- ity of 10 to 95%, with no condensation. • Atmospheric pressure of 700 to 1060 hPa (altitude of –400 to 3000m). • When storing the instrument: • Do not store the instrume ...

  • Konica Minolta PULSOX-300 - page 13

    11 Foreword Disposal Method • When disposing of the used battery , insulate the polarity ter - minals with insulating tape etc. If the terminals of the battery come into contact with metal objects, heat generation, explo- sion or re may result. • Make sure that the battery is either disposed of or recycled correctly in accordance with local ...

  • Konica Minolta PULSOX-300 - page 14

    12 Preparations Preparations Before starting measurements using this instrument, follow the procedure given below to ensure that measurements are stable. 1) Attaching the Wrist Band Attach the Wrist Band WB-300 (supplied as a standard accessory) to the instrument. Since the WB-300 is made of elastic material, it allows for exibility and comfort ...

  • Konica Minolta PULSOX-300 - page 15

    13 Preparations 4 Pass the other end of the band outward through band xture B. ◆  T ake care not to twist the band. 2) Connecting the probe Connect the probe’s connector plug into the Probe Connector on the instrument. ◆ Make sure that probe’s connector plug is oriented correctly . ◆ Do not connect it in with excessive force. Doing ...

  • Konica Minolta PULSOX-300 - page 16

    14 Preparations 3) Installing the battery Procedure 1 T urn the battery cover clockwise approximately 90 degrees to open the cover . ◆  When turning the cover , keep the flat part of your finger on the cover ’ s catch. This facilitates opening the cover with minimum force. 2 Insert the battery into the battery compartment according to the po ...

  • Konica Minolta PULSOX-300 - page 17

    15 Measurement Measurement 1) Starting the Measurement 1 Attach the probe to a nger of an adult patient. 2 Press the Power button. ● The Power is ON, all the elements on the display are displayed for about 2 seconds, and then the display changes to the measurement display . ◆  Until the measurement value has been calculated and displayed, ...

  • Konica Minolta PULSOX-300 - page 18

    16 Measurement 2) Reading the display When the instrument is turned ON, all the elements of the LED will light up. The pulse level, pulse rate and SpO 2 value are displayed during measurement. Pulse rate (P .R.) If an error occurs, an error message mainly about P .R. will be displayed. Battery indicate Flashing when battery is nearly empty . Pulse ...

  • Konica Minolta PULSOX-300 - page 19

    17 Measurement 3) Ending the Measurement About Auto Power-Off function The instrument has an auto power-off function that operates independently . If no probe is connected to the PULSOX ("C" blinks) or no probe is attached to the patient ("L" blinks) continuously for more than 2 minutes, the Power is automatically switched off. ...

  • Konica Minolta PULSOX-300 - page 20

    18 Check Points T rouble Shootings Error Messages The instrument display error messages when the error occurs. Check and correspond to them correctly . %RROR-ESSAGES #AUSE 3OLUTION s  #ONNECTTHEPROBETOTHE 05,3/8PROPERLY7HENUSING THEOPTIONAL%XTENSION#ABLE %#CONNECTTH ...

  • Konica Minolta PULSOX-300 - page 21

    19 Check Points s  #HECKTHATTHEPROBEISPROPERLY ATTACHEDTO THEPATIENT)FT HEPROBE ISPROPERLYATTACHEDBUTTHIS ME SSAG ES TILL AP PEAR S THE CIR CUL ATIO N INT HEARE ABEING MEASU REDMA YNOT BE GOOD -OV ETH EPRO BETO AN AREA ...

  • Konica Minolta PULSOX-300 - page 22

    20 Check Points %RROR-ESSAGES #AUSE 3OLUTION s  !TTACHTHEPROBETOTHEBODY CORRECTLY)FTHISMESSAGEIS DISPLAYEDWHENTHEUNITISATTACHED TOTHEPATIENTCORRECTLYTHE MEASUREMENTCONDITIONSARE REGARDEDASBLOODCIRCULATIONOR OTHERCIRCULATORYPROBLEMS? ...

  • Konica Minolta PULSOX-300 - page 23

    21 Check Points %RROR-ESSAGES #AUSE 3OLUTION 4HISMESSAGEINDICATESTHATTHE MEASUREDVALUEISOUTSIDETHE ACCURACYGUARANTEEDRANGE s 4HE3P/  VALUEISBELOW THELOWERL IMIT3P/   OFTHEMEASUREMENT RANGE4HEMEASURED VALUEWILLSTILLBE? ...

  • Konica Minolta PULSOX-300 - page 24

    22 Check Points Maintenance and Inspection • Before using the instrument, make sure that there is no dam - age to the instrument, no damage or wire-breakage in the probe cable and the instrument operates correctly and safely . Cleaning • Dampen a soft cloth with neutral detergent or water , wipe the instrument with it, then wipe off carefully w ...

  • Konica Minolta PULSOX-300 - page 25

    23 Appendix Specication ■ Dual-wavelength pulse type (665nm/880nm) arterial blood oxygen satura- tion measuring instrument • Name: Oxygen Saturation Monitor • Model name: PULSOX-300 ■ Functions: • Measuring range: SpO 2 : 0 to 100% SpO 2 Pulse rate: 30 to 230 bpm • Accuracy: SpO 2 : ±2% SpO 2 (70 to 100% range, 1S.D.) Pulse rate: ± ...

  • Konica Minolta PULSOX-300 - page 26

    24 Appendix Probes (SR-5C, SP-5C, LM-5C, SD-5C) ■ LED-SPD probe ■ T ype • Finger Clip Probe SR-5C • Spot Check Probe SP-5C • Monitor Probe LM-5C • Personal Probe SD-5C ✻ It can be used with one of Extension Cable EC-300 ■ Components that touch the body Cover: Polycarbonate Wrist band: Polyethylene terephthalate, nylon 6 Rating namep ...

  • Konica Minolta PULSOX-300 - page 27

    25 Appendix Appendix Calculation Method for Displayed V alues <Pulse level meter> The pulse level meter displays the transmitted light amount ratio calculated by the following equation. The pulse level is indicated in eight levels (0 to 15%, full scale if over 10%). <Oxygen saturation (SpO 2 )> Updates the moving average of the oxygen s ...

  • Konica Minolta PULSOX-300 - page 28

    26 Appendix EMC Guidance Guidance and manufactures declaration - electromagnetic emissions Guidance and manufactures declaration - electromagnetic immunity The Oxygen Saturation Monitor Model PULSO X-300 is intended for use in the electromagnetic environment specified below. The customer or the user of the Model PULSO X-300 should assure tha ...

  • Konica Minolta PULSOX-300 - page 29

    27 Appendix Guidance and manufactures declaration - electromagnetic immunity The Oxygen Saturation Monitor Model PULSO X-300 is intended for use in the electromagnetic environment specified below. The customer or the user of the Model PULSO X-300 should assure that it is used in such anenvironment. Immunity test IEC 60601 T est level Compliance ...

  • Konica Minolta PULSOX-300 - page 30

    28 Appendix ■ Spectral Absorption of Hb and HbO 2 Absorption coefficient Wa velength Red light Infrared light Measurement Principle This instrument measures the oxygen saturation (SpO 2 ) in arte - rial blood and pulse rate continuously in a non-invasive method by applying optical principles. With this instrument, SpO 2 is dened by the followi ...

  • Konica Minolta PULSOX-300 - page 31

    29 Appendix Relation between Oxygen Saturation and Partial Pressure The relation between oxygen saturation (SpO 2 ) and oxygen partial pressure (PaO 2 ) is shown in the graph below. SpO 2 is the oxygen saturation as measured by pulse oximeters. ■ Oxygen Saturation vs. Oxygen Partial Pressure The curve of the above graph may shift to the right or ...

  • Konica Minolta PULSOX-300 - page 32

    AJF AKK Printed in Japan 9222-1732-34 © 2007-2009 KONICA MINOL T A SENSING, INC. Manufacturer 3-91, Daisen-nishimachi, Sakai-ku, Sakai-shi, Osaka 590-8551, Japan ...

Manufacturer Konica Minolta Category Oxygen Equipment

Documents that we receive from a manufacturer of a Konica Minolta PULSOX-300 can be divided into several groups. They are, among others:
- Konica Minolta technical drawings
- PULSOX-300 manuals
- Konica Minolta product data sheets
- information booklets
- or energy labels Konica Minolta PULSOX-300
All of them are important, but the most important information from the point of view of use of the device are in the user manual Konica Minolta PULSOX-300.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Konica Minolta PULSOX-300, service manual, brief instructions and user manuals Konica Minolta PULSOX-300. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Konica Minolta PULSOX-300.

A complete manual for the device Konica Minolta PULSOX-300, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Konica Minolta PULSOX-300 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Konica Minolta PULSOX-300.

A complete Konica Minolta manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Konica Minolta PULSOX-300 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Konica Minolta PULSOX-300, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Konica Minolta PULSOX-300, that we can find in the current document
3. Tips how to use the basic functions of the device Konica Minolta PULSOX-300 - which should help us in our first steps of using Konica Minolta PULSOX-300
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Konica Minolta PULSOX-300
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Konica Minolta PULSOX-300 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Konica Minolta PULSOX-300?

Use the form below

If you did not solve your problem by using a manual Konica Minolta PULSOX-300, ask a question using the form below. If a user had a similar problem with Konica Minolta PULSOX-300 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)