Manual Vanguard Heating 36" Flame Oak Log

26 pages 0.56 mb
Download

Go to site of 26

Summary
  • Vanguard Heating 36" Flame Oak Log - page 1

    UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER V ariable Manually-Contr olled Models Also Design-Certified As V ented Decorative Appliances ® Save this manual for future reference. This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. * Aftermarket: Completion of sale, not f ...

  • Vanguard Heating 36" Flame Oak Log - page 2

    2 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning re- semble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at ...

  • Vanguard Heating 36" Flame Oak Log - page 3

    3 104309 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire P ...

  • Vanguard Heating 36" Flame Oak Log - page 4

    4 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® PROVIDING ADEQUATE VENTILATION The following ar e excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually T ight Construction 2. ...

  • Vanguard Heating 36" Flame Oak Log - page 5

    5 104309 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the ro ...

  • Vanguard Heating 36" Flame Oak Log - page 6

    6 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ...

  • Vanguard Heating 36" Flame Oak Log - page 7

    7 104309 OWNER’S MANUAL LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Rear * Width Width 18" 17" 14" 24" 20" 24" 17" 14" 28" 21" 30" 17" 14" 34" 24" 36" 17" 14" 40" 30" INSTALLATION AND CLEARANCES (Vent-Free Operation Only) Fi ...

  • Vanguard Heating 36" Flame Oak Log - page 8

    8 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening. Noncombus- tible ...

  • Vanguard Heating 36" Flame Oak Log - page 9

    9 104309 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear ...

  • Vanguard Heating 36" Flame Oak Log - page 10

    10 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel. This will in- sure adequate air flow and guard against sooting. Raise firep ...

  • Vanguard Heating 36" Flame Oak Log - page 11

    11 104309 OWNER’S MANUAL CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane sup- ply. This heater requires an exter- nal regulator (not supplied). Install the external regulator between the heater and propane supply. Install ...

  • Vanguard Heating 36" Flame Oak Log - page 12

    12 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ON POSITION OFF POSITION Figure 15 - Manual Shutoff Valve Open Closed Manual Shutoff Valve Figure 16 - Checking Gas Joints WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks ...

  • Vanguard Heating 36" Flame Oak Log - page 13

    13 104309 OWNER’S MANUAL INST ALLA TION Continued WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. INSTALLING LOGS It is very important to install the logs exactly as instructed. Do not modify logs. Only us ...

  • Vanguard Heating 36" Flame Oak Log - page 14

    14 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® 1. STOP! Read the safety inf ormation, column 1. 2. Make sur e manual shutoff valve is fully open. 3. Set switch in OFF position. OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result cau ...

  • Vanguard Heating 36" Flame Oak Log - page 15

    15 104309 OWNER’S MANUAL Figure 20- Pilot Ignitor Electrode Pilot Burner 8. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. After 30 seconds, release contr ol knob . • If control knob does not pop out when released, contact a qualif ied service person or gas supplier f or repairs. Note: If pilot goes out, repeat steps 4 thro ...

  • Vanguard Heating 36" Flame Oak Log - page 16

    16 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® IMPORT ANT: This remote control has been specially engineered to take an air temperature sample e v- ery 5.5 minutes in the A UTO mode. It will not respond immediately to the temperature setting being turned up or do wn. IMPORT ANT : The hand-held re- mote control unit must be ne ...

  • Vanguard Heating 36" Flame Oak Log - page 17

    17 104309 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor ...

  • Vanguard Heating 36" Flame Oak Log - page 18

    18 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensation noticed on windows Heater produces a whistling noise when burner is lit White powder resid ...

  • Vanguard Heating 36" Flame Oak Log - page 19

    19 104309 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re ...

  • Vanguard Heating 36" Flame Oak Log - page 20

    20 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® SPECIFICA TIONS Golden Oak Golden Oak 18" Remote 24”,30”,and 36" Ready Remote Ready Btu (Variable) 16,000/30,000 20,000/39,000 Type Gas Propane Only Propane Only Ignition Piezo Piezo Pressure Manifold 8.0" W.C. 8.0" W.C. Inlet Gas Pressure (in. of water) M ...

  • Vanguard Heating 36" Flame Oak Log - page 21

    21 104309 OWNER’S MANUAL CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleanin ...

  • Vanguard Heating 36" Flame Oak Log - page 22

    22 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX™ GOLDEN OAK LOG MODELS VYD18PR, VYD24PR, VYD30PR, AND VYD36PR 4 13 13 14 22 13 8 18 7 6 9 1 12 5 23 16 15 17 3 11 2 10 10 19 24 19 20 21 O F F P I L O T O N H I L O O F F P I L O T O N H I L O * Note: The Golden Oak Log (104254-01) for ...

  • Vanguard Heating 36" Flame Oak Log - page 23

    23 104309 OWNER’S MANUAL P ARTS LIST VYD18PR, VYD24PR, VYD30PR, AND VYD36PR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY PART NUMBER FOR NO. VYD18PR VYD24PR VYD30PR VYD36PR DESCRIPTION QTY. 1 103517-01 102785-02 103519-01 104254 ...

  • Vanguard Heating 36" Flame Oak Log - page 24

    24 104309 UNVENTED PROP ANE/LP GAS LOG HEA TER V ANGUARD FLAME-MAX ® ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual. MAN ...

  • Vanguard Heating 36" Flame Oak Log - page 25

    25 104309 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Vanguard Heating 36" Flame Oak Log - page 26

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED ...

Manufacturer Vanguard Heating Category Indoor Fireplace

Documents that we receive from a manufacturer of a Vanguard Heating 36" Flame Oak Log can be divided into several groups. They are, among others:
- Vanguard Heating technical drawings
- 36" Flame Oak Log manuals
- Vanguard Heating product data sheets
- information booklets
- or energy labels Vanguard Heating 36" Flame Oak Log
All of them are important, but the most important information from the point of view of use of the device are in the user manual Vanguard Heating 36" Flame Oak Log.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Vanguard Heating 36" Flame Oak Log, service manual, brief instructions and user manuals Vanguard Heating 36" Flame Oak Log. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Vanguard Heating 36" Flame Oak Log.

A complete manual for the device Vanguard Heating 36" Flame Oak Log, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Vanguard Heating 36" Flame Oak Log by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Vanguard Heating 36" Flame Oak Log.

A complete Vanguard Heating manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Vanguard Heating 36" Flame Oak Log - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Vanguard Heating 36" Flame Oak Log, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Vanguard Heating 36" Flame Oak Log, that we can find in the current document
3. Tips how to use the basic functions of the device Vanguard Heating 36" Flame Oak Log - which should help us in our first steps of using Vanguard Heating 36" Flame Oak Log
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Vanguard Heating 36" Flame Oak Log
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Vanguard Heating 36" Flame Oak Log in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Vanguard Heating 36" Flame Oak Log?

Use the form below

If you did not solve your problem by using a manual Vanguard Heating 36" Flame Oak Log, ask a question using the form below. If a user had a similar problem with Vanguard Heating 36" Flame Oak Log it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)