  • Sanyo E11A202U - page 1

    Uninterruptibl e Power Suppl y SANUPS E1 1A202U Instruction Manual M0007125 B ...

  • Sanyo E11A202U - page 2

    ...

  • Sanyo E11A202U - page 3

    Intr oducti on Thank you fo r choos ing the SANUPS ( E1 1A202U). SA VE THESE INSTRUCTIONS This manual c ontains imp ortant instr uctions for E1 1A202U that should be followe d during installatio n and main tenance of the UPS an d batteri es.T o use th e UPS cor rectl y and safel y , read th is manu al before u sing the UPS. After reading, p lease k ...

  • Sanyo E11A202U - page 4

    − 1 − 1. Safety Prec autions PRECAUTIONS (IMPOR T ANT SAFE TY INSTRU CTIONS) Before installing, o perat ing, perfor ming maintenanc e or inspecting the UPS, be sure to read t his manual and accom panyi ng docu ments carefu lly to obtai n a cl ear u nders tandin g of th e in formati on rel ated t o its opera tion, safe ty and import ant prec aut ...

  • Sanyo E11A202U - page 5

    − 2 − 1. Installation Precautions CAUTION • The UPS sho uld be installed only by technically qualif ied perso nnel. Improper installation can result in electri c shock, bodily i njury , an d/or fire . • Never operat e or st ore th e UPS i n the fol lowin g envir onmen tal con diti ons. Doi ng so ma y ca use the UPS to malfunct ion, sus tain ...

  • Sanyo E11A202U - page 6

    − 3 − 3. Operatin g Precau tions DANG ER • Immediate ly shut th e UPS off if it malfuncti ons, or if an unusual od or or noise is obser ved. Failur e to do so may res ult in a f ire. • T o avoid el ectric shock , do not open the c over of the UPS. CAUTION • Risk of electr ic shock, do not remove cover , No us er serviceable p art insid e. ...

  • Sanyo E11A202U - page 7

    − 4 − 4. Radio Frequency I nterference CAUTION • This equipm ent has be en tested and found to comply with the limit s for a Clas s A d igital device , pursuant to part 1 5 of the FC C Rul es. T hese l imits a re d esigned to p rovid e reas onabl e prote ction agai nst ha rmful interf erenc e when the equ ipmen t is ope rated i n a comm erci ...

  • Sanyo E11A202U - page 8

    − 5 − 7. Batt ery Hand ling Precau tions CAUTION • Risk of explosio n if battery is replaced by an incorrect type • Dispos e of us ed batt eries a ccordi ng to th e instru ctions . • Batte ry servicing s hould be per formed by te chnically qualifie d perso nnel. Keep unqualified p ersonne l away from batter ies. • Replac e batte ries on ...

  • Sanyo E11A202U - page 9

    − 6 − 2. For Proper Operation 2.1 Input Power Requirements (1) Please use UPS as a commercial power suppl y in the region and the output voltage of UPS are matched ref erring to the table be low . MODEL AC input volt age AC input fre quency NOTE E1 1A 202U001 120V (+15%,- 20%) 50 or 60Hz ( ± 5%) ※ E1 1A 202U001 J 100,1 10,115,120V (+15%, -20 ...

  • Sanyo E11A202U - page 10

    − 7 − (3) Power supply environm ent If the UPS is used in a n environment s ubject to long and frequent p ower outages (m ore than once a week), t he batteries may not receiv e s ufficient charge, which could res ult in foreshortened ba ttery life and prema ture battery failure. (4) If the UPS is not operat ed for a long period, the b atteries ...

  • Sanyo E11A202U - page 11

    − 8 − 4. Overview The SA NUPS E1 1A is a stationary-t ype uninterruptibl e power supply desi gned to provide high-quality , stable AC power to critica l equipment that re quires continuous, uninterrupted power . The UPS is compri sed of rectifier , charger , inverter , batter y , and utili ty power transfer (bypass ) circuits. In the event of f ...

  • Sanyo E11A202U - page 12

    − 9 − 5. Exter nal Dimensions and Part Names 5.1 Front and Back Panels Depth: 565 mm (22.24 inch) W e ight: 29 kg (63.93 lbs) No. Name Label Function ① Control panel and indicators - Control p anel for c ontrol ope rations, UP S status display , and function settings ② Forced by pass switc h Forced Bypass Switc h to bypass UPS during main ...

  • Sanyo E11A202U - page 13

    − 10 − 5.2 Control Panel and Indicators Functions No. Label Status dis play Lit Not lit Slow b link Fast blink LED0 I NPUT Input po wer status Norm al input - Input error - LED1 OUTPUT UPS output p o wer status Inverte r operati on OFF Bypass operati on - LED2 ECONOMY Operation mode Econom y mode operat ion (*1 ) OFF (*3) - - LED3 DO ...

  • Sanyo E11A202U - page 14

    − 11 − 5.3 External Interf aces UPS back panel No. Name Function ① PC I/F (PC interface) (RS-232C) Allows y ou to contr ol the UP S from a c omputer (PC or work station) by u sing the supplied powe r management software. Insta ll the power management softw are (*2) on the c omputer , and connec t the compu ter to t he UPS with the sup plied n ...

  • Sanyo E11A202U - page 15

    − 12 − 6. Installation CAUTION ! ・ When insta lling the UPS , carefully f ollow the instructi ons in this Instr uction Ma nual. ・ Install the UPS on a st able s urface that c an bear th e weight (29 k g, 63.93 lbs). This surfac e should be flat, so th e UPS cann ot fall a nd cause b odily injury . ・ The possib ility of v ibration a nd s ...

  • Sanyo E11A202U - page 16

    − 13 − 6.4 Preparat ion Before Ins tallation CAU TI ON ! ・ W ear insulated g loves and take other precaut ions when c onnecting the batter ies. Otherw ise electric shock c an result. ・ There is a constant vo ltage (max . approx. 4 8V : approx. 12V × 4) at the bat tery terminals . Do not touch them with your ha nds or short circuit them. ...

  • Sanyo E11A202U - page 17

    − 14 − 6.5 Attaching the Stand CAUTION ! ・ Unless t he UPS is s ecured s olidly in place, it c an shift or fall duri ng seismic events ( earthquakes) or whe n it is subj ected to s hock or v ibration, po ssibly causing b odily injury . ・ Be careful not to g et your hands caught when installing the stand. Proceed as follows to atta ch the ...

  • Sanyo E11A202U - page 18

    − 15 − 6.6 Mounting a Rack Mount T ype UPS CAU TIO N ! ・ Be carefu l to avo id straini ng your lowe r back when m oving and in stalli ng the UPS. ・ The UPS w eighs about 29 k g (63.93 lbs). Always get at least one other perso n to help you in stall it. B odily inj ury can result if the UPS falls. ・ The UPS can fall whe n it is moved or ...

  • Sanyo E11A202U - page 19

    − 16 − 7. W iring CAUT ION ! ・ Check that input and output p ower plugs ar e firmly seated. D o not exceed the rated capaci ty when connecting load s to the output terminals. Check that plugs and ca rds are fir mly seat ed in the external int erfaces. Fai lure to ob serve these pr ecautions c an result in elect ric shock, fire, or b odily i ...

  • Sanyo E11A202U - page 20

    − 17 − ③ Connect the inpu t power plugs of the load device s to the ou tput terminals. MODEL Output term inal ca pacity Note E1 1A202U001 125V 20A receptacl e × 4pcs. (NEMA 5-20R) The total output from all output re ceptacles mus t not exceed 2. 0kV A ( 1.4kW ) If yo u must ma ke a sin gle-wire ground ed connect ion, always connect the g ...

  • Sanyo E11A202U - page 21

    − 18 − 8. Preparations Befor e Operation Check the fol lowing items before st arting operation: ① V isually inspect the UPS to verify that t here is no visibl e damage. ② Check that the UPS is connected to a utility power source that meets the input specification s. ③ Chec k that the input breaker MAIN MCCB is set to “OFF”. ④ Check ...

  • Sanyo E11A202U - page 22

    − 19 − 9. Operating Procedures 9.1 UPS St artup (Normal Oper ation) Check that the INPUT indicato r has changed from blin king to lit, and then proceed to step ② . ・ The gree n LOADLEVEL 25 to 100% indi cator and the red LOADLEVEL O.L indicato r light according to the load connected to the UPS. ・ The green ECON OMY indica tor lights w hen ...

  • Sanyo E11A202U - page 23

    − 20 − 9.2 UPS St artup (Battery Power ) During a power ou tage, low voltage, o r other trouble with the AC input power to the UPS, you can supply power t o the inverter output from the bu ilt-in batteries. ※ Retur n to the Nor mal Operatio n and batter ies are c harged. Hold fo r about 6 seco nds Buzzer Musical tr ill LEDs Green IN PUT Blink ...

  • Sanyo E11A202U - page 24

    − 21 − 9.3 Outage S imulation T est Y ou should perform a tes t of whether the UPS operat es properly during a power outa ge. Proper operati on is as described bel ow . Note Perform th is test before powering the connected loa d devices on. Note If your ut ility pow er breaker panel is to o far away t o access c onveniently , you can also per f ...

  • Sanyo E11A202U - page 25

    − 22 − 9.4 UPS Shutdown ( Daily) Note Do not to uch MAIN MCCB when yo u perform a d aily shutdown. Leave it set to the “ON” pos ition. *Note The length o f time to keep held down varies depending on the set ting of item “ ⑨ switch res ponse time” in §10. 1 “Setup Menu It em List”. Operat e as follows. When “1 se cond” is sele ...

  • Sanyo E11A202U - page 26

    − 23 − 10. User Sett ing s 10.1 Setup Menu Item List Y ou can configure t he UPS by sett ing the menu item s in th e following list. Configu re it accordin g to your environ ment and requirements . The con trols and indica tors on the control panel are used to set items in the Se tup menu. For d etails, se e §10.2 “ Setup Menu Operatio ns” ...

  • Sanyo E11A202U - page 27

    − 24 − Note: Changes to some m enu items do not take effect until you rest art the UPS. These item s are indicated b y (RESTART) in t he "Menu It em" column. If a restart is required, be sure to power off the load devices b efore resetting. See §9.5 “UPS Shutdown (If N ot to Be Used for More Than a W eek)” for informatio n ab out ...

  • Sanyo E11A202U - page 28

    − 25 − T wo be eps s ound f rom th e buzz er . The setting is saved and the UP S returns to n ormal op eratio n. 10.2 Setup Menu Oper ations Set all menu it ems with the following procedure. This example shows how to se t the “UPS operati on mode” ite m to “Economy”. ① W ith MAIN MCCB on the back p ane l set to “ON”, che ck that t ...

  • Sanyo E11A202U - page 29

    − 26 − 1 1. Maintenance and Inspecti on 1 1.1 Daily Inspection Check the cont rol panel LED indicators to conf irm that no error is indicated. Remove any dust or dirt adhering to the intake and exhaust vents and fan. No other specia l inspection or main tenance is required. 1 1.2 Periodic Inspection Inspect the fol lowing items once every 6 mon ...

  • Sanyo E11A202U - page 30

    − 27 − 1 1.4 Battery Maintenance CAUTION ! ・ Interna l maintenance a nd inspe ction should be perfor med only by t e chnical ly qualified p ersonnel. E lectric shoc k, injur y , burning, s moke or file could otherwis e result . ・ Batterie s should be re placed periodical ly . Batteries used after thei r service life has passed may cause a ...

  • Sanyo E11A202U - page 31

    − 28 − 1 1.5 Battery T est Y ou can pe rform automat ic and manual te sts of the built-in and ex ternally con nected batterie s. Y ou can do this without st opping the load devices conne cted to the UPS. When it is shipped from the fa ctory , the UPS is set up to perfor m an automatic battery test once every 6 m onths. T o change the autom atic ...

  • Sanyo E11A202U - page 32

    − 29 − 1 1.6 Battery Exchange Y ou can exchange the ba tteries without stoppi ng the load devices. H owever , this should be done as quickly as possibl e, because the UPS will be unable to pro vide backup power in the event of a power ou tage. When exchangi ng the batteries ,replace the al l batteries. CAUTION ! ・ The batter y pack weighs a ...

  • Sanyo E11A202U - page 33

    − 30 − ⑦ Co nfir m the "Forc ed Byp ass swi tch. ( Usual in verte r side) ⑧ Attach the ba ttery cover and f i x this cover wit h 1 screw . ⑨ Attach the fr ont panel. ⑩ Reset the remaining bat tery service life wi th item ⑯ “Re set remaining batte ry life” in §10.1 “Se tup Menu Ite m List”. Fo r detail s, see § 10 “Use ...

  • Sanyo E11A202U - page 34

    − 31 − 1 1.7 Bypass Breaker Reset CAUTION ! Always po wer the UPS off befo re resetting the b ypass breaker . Fai lure to do so can cau se elec tric shock . Be car eful to av oid injur y or elec tric shock . If the bypass breaker trips, the red AL ARM indicator lights and out put from the output termin als sto ps. Proceed as follows to reset ...

  • Sanyo E11A202U - page 35

    − 32 − 12. T roubleshooting If a problem occurs , check the condition of the equipm ent and perform countermea sures as listed in the ta ble below . CAUTION ! ・ Interna l maintenance a nd inspe ction should be perf ormed only by technical ly qualified per sonnel. E lectric shoc k, injury , burning , fuming or fire could o therwise resul t. ...

  • Sanyo E11A202U - page 36

    − 33 − Condi tion Countermea sure No reco very from utility power so urce failure . Utility power sour ce failure o ccurs frequen tly . ・ Check whether MA IN MCC B on the back panel of the U PS is in the “ON” positi on. (If MAIN MCCB is set to the “OFF” positio n during normal o peration, the same operation as for a utili ty power sou ...

  • Sanyo E11A202U - page 37

    − 34 − 13. Alarm Sou nds The alarm buzzer e mits sound patterns to aler t you to failures a nd error conditions in the UPS. Check the so und pattern and re fer to the f ollowing table to for the ste ps to take. Sound Pattern UPS Status What to Do This is a mec hanical failure. Contact your supplier . During by pass operati on The bypass bre ake ...

  • Sanyo E11A202U - page 38

    − 35 − 14. Maintenance Bypass Power Supply (Option) Y ou can combine this UPS wit h an optional Maintenance Bypa ss Unit. In the event of a failure in the UPS, you c an then exchange the UPS after manually switchi ng from bypass power supply to maint enance bypass power supply . Note The foll owing descr iption ap plies to u se with an optional ...

  • Sanyo E11A202U - page 39

    − 36 − 15. Functional Descr iption 15.1 Basic Op eration (1) Normal Operation In normal opera tion, the UP S switches automatica lly * betwee n the three mode s (a) to ( c) depending on t he state of th e power . * The UP S does not swit ch automatical ly when item ① “UPS operation m ode” in § 10.1 “Setup Menu It em List” is set to ? ...

  • Sanyo E11A202U - page 40

    − 37 − (c) Econom y m ode The UPS switches to Economy mode when the input power vol tage is within a certain range and the out put power fa ctor is above a c ertain value. In Ec onomy mode, the UPS receives power fro m the utility power source and supplies it to the load. At th e same time, the inverte r is connecte d to the load and read y to ...

  • Sanyo E11A202U - page 41

    − 38 − 15.2 Protective Functi ons (1) Overload Protection If the UPS output is overl oaded by exceeding t he cur rent capacity of t he inverter , such as when a computer s ystem boots up, the output sel ector switch automati cally switches the source of AC power from the inverter to the b ypass circuit, without interruption. After a certain per ...

  • Sanyo E11A202U - page 42

    − 39 − 15.3 Protective Functi on T able The following t able shows functions a nd operations which act ivate to protect the UP S. The ○ mar k indicates lit LEDs and buzzer alarms. Operat ion panel (front panel) indic ators Alarms Item INPUT Green OUTPUT Green INV .ON ST AND BY Green ALARM Red O.L Red BA TT . LOW Red Buzzer pattern (*1) Protec ...

  • Sanyo E11A202U - page 43

    − 40 − 15.4 Specif ications Item Stand ard or Performan ce Notes MODEL E1 1A202U 001 E1 1A202U001J (*6) Output ca pacit y 2.0kV A/1.4k W Coolin g sy stem Forc ed air cooli ng T ype of Input pulg NEMA 5-20P NEMA L5-30P (*6) When t he plu g is NEMA _5-20, t he input and output voltage of UPS are 120V . only (For UL rules.) Phases Single phase, 2- ...

  • Sanyo E11A202U - page 44

    − 41 − (*5): The above t able lists standar d specificati ons. Some sp ecifications ar e different for units with long backup tim es. For detai ls, refer to the external battery s pecificatio n instruction m anual. ( * 6 ) : When Input plug is NEMA 5-20P type (M ODEL:E11A202U001), output voltage is 120V only. If you int end to use this UPS w i ...

  • Sanyo E11A202U - page 45

    − 42 − Appendix. Usage notes for SANUPS SOFTW ARE ST ANDALONE When using supp lied “SANUPS SOFTW ARE ST AN DALONE”, please note the following instructions. “Charge ” on the m ain screen of “SANUPS SOFTW ARE ST AND ALONE” For the charge ra te (as a %) of the ba ttery displayed on the main screen of “SANUPS SOFTW ARE S T ANDALONE” ...

  • Sanyo E11A202U - page 46

    − 43 − 1. I n §6.4 (1) “Setting the shutd own trigger conditions”, if “When the battery- low occurs, shutdown execution” is selected as the shutdown trig ger conditions, set the time mo re than 40% of t he presumed backup time dis played on the main s creen. Refer to §6.4 “Sett ing the Shutdown Cond itions” in t he User Guide o f ...

  • Sanyo E11A202U - page 47

    − 44 − LED blinking for setting up menu For the following t wo Menu Item, • “Restart time (battery cha rge rate)” in th e E1 1A Instruction Manual §10.1 “ Setup Menu Item List No. ⑦ ”. • “Low battery voltage signal timing” in the E1 1 A Instruction Manual §10.1 “Se tup Menu Item List No. ⑫ ”. when confirming tw o items ...

Manufacturer Sanyo Category Power Supply

Documents that we receive from a manufacturer of a Sanyo E11A202U can be divided into several groups. They are, among others:
- Sanyo technical drawings
- E11A202U manuals
- Sanyo product data sheets
- information booklets
- or energy labels Sanyo E11A202U
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sanyo E11A202U.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sanyo E11A202U, service manual, brief instructions and user manuals Sanyo E11A202U. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sanyo E11A202U.

Similar manuals

A complete manual for the device Sanyo E11A202U, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sanyo E11A202U by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sanyo E11A202U.

A complete Sanyo manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sanyo E11A202U - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sanyo E11A202U, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sanyo E11A202U, that we can find in the current document
3. Tips how to use the basic functions of the device Sanyo E11A202U - which should help us in our first steps of using Sanyo E11A202U
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sanyo E11A202U
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sanyo E11A202U in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sanyo E11A202U?

Use the form below

If you did not solve your problem by using a manual Sanyo E11A202U, ask a question using the form below. If a user had a similar problem with Sanyo E11A202U it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)