    UNVENTED (VENT -FREE) PROP ANE/LP GAS LOG HEA TER Heat Majic™ Models FVF18PW , FVF24PW, and FVF30PW (Millivolt) Remote Ready ALSO DESIGN-CER TIFIED AS A VENTED DECORA TIVE APPLIANCE OWNER’S OPERA TION AND INST ALLA TION MANUAL P I L O T O F F O N LO O F F O N A U T O HI Save this manual for future reference. WARNING: If the information in this ...

  • FMI FVF18PW - page 2

    2 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED SAFETY INFORMA TION DANGER: Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly. G ...

  • FMI FVF18PW - page 3

    3 105194 OWNER’S MANUAL A U T O O F F O N O F F P I L O T O N H I L O H I L O PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1/NFPA 54 *. *Available from: American National Standards Institute, Inc. 1430 Bro ...

  • FMI FVF18PW - page 4

    4 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223.1/NFPA 54, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Co ...

  • FMI FVF18PW - page 5

    5 105194 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the ro ...

  • FMI FVF18PW - page 6

    6 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within ...

  • FMI FVF18PW - page 7

    7 105194 OWNER’S MANUAL LOG SIZING REQUIREMENTS Log Minimum Firebox Size Height Depth Front Rear * Width Width 18" 17" 14" 24" 20" 24" 17" 14" 28" 21" 30" 17" 14" 34" 24" INSTALLATION AND CLEARANCES (Vent-Free Operation Only) WARNING: Maintain the mini- mum clearances. If ...

  • FMI FVF18PW - page 8

    8 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED INST ALLA TION Continued Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening. ...

  • FMI FVF18PW - page 9

    9 105194 OWNER’S MANUAL Figure 7 - Minimum Mantel Clearances When Using Hood INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood MANTEL CLEARANCES In addition to meeting noncombustible mate- rial clearances, you must also meet required clearances between fireplace opening and mantel shelf. If you do not meet the clear ...

  • FMI FVF18PW - page 10

    10 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED INST ALLA TION Continued INSTALLING HEATER BASE ASSEMBLY WARNING: If installing in a sunken fireplace, special care is needed. You must raise the fire- place floor to allow access to heater control panel. This will in- sure adequate air flow and guard against soot ...

  • FMI FVF18PW - page 11

    11 105194 OWNER’S MANUAL CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator be- tween the heater and propane/LP supply. Inst ...

  • FMI FVF18PW - page 12

    12 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED ON POSITION OFF POSITION Figure 15 - Equipment Shutoff Valve Open Closed Equipment Shutoff Valve Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and ...

  • FMI FVF18PW - page 13

    13 105194 OWNER’S MANUAL A U T O O F F O N A U T O O F F O N O F F P I L O T O N H I L O H I L O INST ALLA TION Continued Figure 16 - Checking Gas Joints WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury. ...

  • FMI FVF18PW - page 14

    14 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED O F F P I L O T O N L O I H AUTO OFF ON 1. STOP! Read the safety inf ormation in column 1. 2. Make sure equipment shutoff valv e is fully open. 3. Set switch in OFF position. OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low t ...

  • FMI FVF18PW - page 15

    15 105194 OWNER’S MANUAL Figure 21- Pilot Ignitor Electrode Pilot Burner 9. Slightly push in and turn contr ol knob counterclockwise to the ON position. 10. W ait one minute and switch selector switch to the ON position to light b urner . Note: AUT O is only functional when using GWMT1 or GWMS2 op- tional accessories. 11. Set flame adjustment kno ...

  • FMI FVF18PW - page 16

    16 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED OPERA TING HEA TER Continued Figure 22 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation Selector Switch in Remote Position (Optional Remote Control) ON OFF REMOTE O F F P I L O T O N L O I H Control Knob in On Position Fl ...

  • FMI FVF18PW - page 17

    17 105194 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor ...

  • FMI FVF18PW - page 18

    18 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensation noticed on windows Heater produces a whistling noise when burner is lit Wh ...

  • FMI FVF18PW - page 19

    19 105194 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Follow the gas supplier ’ s instructions. • If you canno ...

  • FMI FVF18PW - page 20

    20 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call F ...

  • FMI FVF18PW - page 21

    21 105194 OWNER’S MANUAL SPECIFICA TIONS Heat Majic ™ 18" Heat Majic ™ 24" and 30" Remote Ready Remote Ready Btu 17,500/27,000 19,000/31,500 Type Gas Propane/LP Only Propane/LP Only Ignition Piezo Piezo Pressure Manifold 8.0" W.C. 8.0" W.C. Inlet Gas Pressure (in. of water) Maximum 14" 14" Minimum* 11" ...

  • FMI FVF18PW - page 22

    22 105194 UNVENTED PROP ANE/LP GAS LOG HEA TER FIREPLACE MANUF ACTURERS INCORPORA TED ILLUSTRA TED PA R T S BREAKDOWN HEAT MAJIC ™ LOG MODELS FVF18PW, FVF24PW, AND FVF30PW 4 13 13 14 22 13 8 18 7 6 10 9 1 12 5 23 16 15 17 3 11 2 10 19 24 19 20 21 O F F P I L O T O N H I L O O F F P I L O T O N H I L O ...

  • FMI FVF18PW - page 23

    23 105194 OWNER’S MANUAL P AR TS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 20 of this manual. KEY PART NUMBER FOR NO. FVF18PW FVF24PW FVF30PW DESCRIPTION QTY. 1 105186-01 105186-02 105186-03 Log, 1 Piece 1 2 103778-01 103778-01 103778-01 ODS P ...

  • FMI FVF18PW - page 24

    105194-01 Rev. D 03/02 NOT A UPC KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model S ...

Manufacturer FMI Category Gas Heater

Documents that we receive from a manufacturer of a FMI FVF18PW can be divided into several groups. They are, among others:
- FMI technical drawings
- FVF18PW manuals
- FMI product data sheets
- information booklets
- or energy labels FMI FVF18PW
All of them are important, but the most important information from the point of view of use of the device are in the user manual FMI FVF18PW.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals FMI FVF18PW, service manual, brief instructions and user manuals FMI FVF18PW. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product FMI FVF18PW.

Similar manuals

A complete manual for the device FMI FVF18PW, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use FMI FVF18PW by users. Manuals are usually written by a technical writer, but in a language understandable to all users of FMI FVF18PW.

A complete FMI manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual FMI FVF18PW - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the FMI FVF18PW, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the FMI FVF18PW, that we can find in the current document
3. Tips how to use the basic functions of the device FMI FVF18PW - which should help us in our first steps of using FMI FVF18PW
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with FMI FVF18PW
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of FMI FVF18PW in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning FMI FVF18PW?

Use the form below

If you did not solve your problem by using a manual FMI FVF18PW, ask a question using the form below. If a user had a similar problem with FMI FVF18PW it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)