Manual National Instruments FPT-1015

33 pages 0.58 mb
Download

Go to site of 33

Summary
  • National Instruments FPT-1015 - page 1

    FP T -1015 User Manual FPT -1015 User Manual December 2006 372051A-01 ...

  • National Instruments FPT-1015 - page 2

    Support Worldwide Technical Support and Product Info rmation ni.com National Instruments Corporate Headquarters 11500 North Mopac Expressway Aust in, Texas 78759-3504 USA Tel: 512 683 0100 Worldwide Offices Australia 1800 300 800, Austria 43 0 662 45 79 90 0, Belgium 32 0 2 757 00 20, Brazil 55 11 3262 3599, Canada 800 433 3488, China 86 21 6555 78 ...

  • National Instruments FPT-1015 - page 3

    Important Information Warranty The FPT-1015 is warranted against defects in materials and workmanship for a period of one year from the date of s hipment, as e videnced by receipts or other documentation. National Instruments will, at its option, repair or replace equi pment that proves to be defect ive during the warranty period. This warrant y in ...

  • National Instruments FPT-1015 - page 4

    Compliance Compliance with FCC/Canada Radio Frequency Interference Regulations Determining FCC Class The Federal Communications Commission (FCC) has rules to protect wireless co mmunications from inte rference. The FCC places digital electronics into two classes. These classes are known as Class A (for use in industrial-commercial locations onl y) ...

  • National Instruments FPT-1015 - page 5

    Conventions The follo wing con ventions are used in this manual: » The » symbol leads you through nested menu items and dialog box options to a final action. The sequence File»Page Setup»Options directs yo u to pull down the File menu, select the Page Setup item, and select Options from the last dialog box. This icon denotes a n ote, which aler ...

  • National Instruments FPT-1015 - page 6

    © National Instruments Corporation vii FPT-1015 User Manual Contents Chapter 1 General Information Introduction ............. .............. .............. .............. .............. .............. ............... .............. ... .1 - 1 Connectors .............. .............. .............. .............. ........... ............... ....... ...

  • National Instruments FPT-1015 - page 7

    © National Instruments Corporatio n 1-1 FPT -1015 User Manual 1 General Information This chapter includes an overvi ew of the FPT-1015 human machine interface (HMI). Introduction The FPT-1015 is a 15 in. color TFT LCD flat panel monitor for industrial applications. With the optional t ouchscreen, this monitor is a user-friendly system control inte ...

  • National Instruments FPT-1015 - page 8

    Chapter 1 General Information FPT -1015 User Manual 1-2 ni.com USB T ype B T ouchscreen Connector The FPT-1015 includes this connector and a touchscreen cable if a touchscreen is installed. You must connect it to the PC US B port. DC 12 V Power In This connector connects to the DC 12 V switching pow er supply. ...

  • National Instruments FPT-1015 - page 9

    © National Instruments Corporatio n 2-1 FPT -1015 User Manual 2 Mounting This chapter explains how to mount the FPT-1015. Important Safety Information Before setting up the FPT-1015, read these safety instructions carefully. Disconnect this equipment from an y A C outlet before cleaning. Use a da mp cloth. Do not use liquid or spray detergents for ...

  • National Instruments FPT-1015 - page 10

    Chapter 2 Mountin g FPT -1015 User Manual 2-2 ni.com If one of the following situations ar ises, ha ve service personnel check the equipment: • The power cord or plug is damaged. • Liquid has penetrated into the equipm ent. • The equipment has been exposed to moisture. • The equipment does not work well, o r you cannot get it to work accord ...

  • National Instruments FPT-1015 - page 11

    Chapter 2 Mounting © National Instruments Corporatio n 2-3 FPT -1015 User Manual W all Mounting The FPT-1015 wall mounting kit is optional. As shown in Figure 2-1 , screw the hook and wall-mounted br ackets to the wall and attach the FPT-1015 to the bracket. Figure 2-1. W all Mounting Hook Brack et W all-Mounting Brac ket ...

  • National Instruments FPT-1015 - page 12

    Chapter 2 Mountin g FPT -1015 User Manual 2-4 ni.com Panel Mounting Refer to Figure 2-2 and follow these steps to inst all the FPT-1015 in a panel: 1. Place the panel-mounting brackets on the FPT -1015. 2. Fasten the panel-mounting brackets with the screws. 3. Insert the FPT -1015 in the panel. 4. T ighten the screws to fasten the FPT -1015 to the ...

  • National Instruments FPT-1015 - page 13

    Chapter 2 Mounting © National Instruments Corporatio n 2-5 FPT -1015 User Manual Rack Mounting The rack mounting kit is optional. As sh own in Figure 2-3, you can directly mount the FPT-1015 in a standard 19 in. rack and secure it with four screws. Figure 2-3. Rack Mounting ...

  • National Instruments FPT-1015 - page 14

    Chapter 2 Mountin g FPT -1015 User Manual 2-6 ni.com Desktop Stand Mounting The desktop stand kit is optional. As shown in Figure 2-4, attach the desktop stand bracket to the rear of the monitor with two screws. Figure 2-4. Desktop Stan d Mounting Power Adapter Mounting Attach the power adapter bracket to th e rear of the FPT-1 015 monitor using fo ...

  • National Instruments FPT-1015 - page 15

    © National Instruments Corporation A-1 FPT-1015 User Manual A Specifications Physical Construction ........... .............. ...... ........ .... Heavy-duty steel chassis Front Panel ...................... .............. ......... Al-Mg, NEMA4/IP65 compliant Control ............. ............... .............. ......... Onscreen display (OSD) con ...

  • National Instruments FPT-1015 - page 16

    Appendix A Specifications FPT-1015 User Manu al A-2 ni.com Dimensions 383 [15.07] 307 [12.08] 372.6 [14.66] 308.26 [12.13] 270.59 [10.65] 296.6 [11.67] 214.1 [8.42] 15 [0.59] 4.5 [0.17] 18.5 [0.72] 48.13 [1.89] 100 [3.93] 75 [2.95] 100 [3.93] 75 [2.95] ...

  • National Instruments FPT-1015 - page 17

    Appendix A Specifications © National Instruments Corporation A-3 FPT-1015 User Manual T ouchscreen Type ...... .............. .............. ................. .... 8 wire, analog resistive Resolution .............. .............. ................. . 1024 × 1024 Light transmission ...................... ..... ....... 75% (gouge hardness is greater ...

  • National Instruments FPT-1015 - page 18

    Appendix A Specifications FPT-1015 User Manu al A-4 ni.com Sensor board ......................... .............. ....Chemical strengthened glass with 4 H hardness standard (test condition: ASTM D33 63-92A) Ball drop test .............. .............. ......... .. ....Able to bear a 225 g steel ball dropped from 660 m m elevation without breaking Ac ...

  • National Instruments FPT-1015 - page 19

    Appendix A Specifications © National Instruments Corporation A-5 FPT-1015 User Manual Environmental Maximum altitude ......................... ......... 2,000 m Pollution Degree .... .............. .............. .... 2 Indoor use only T ouchscreen Operating temperature range ......... ......... –20 to 50 °C, 2 weeks at 50 °C/90% relative hum ...

  • National Instruments FPT-1015 - page 20

    Appendix A Specifications FPT-1015 User Manu al A-6 ni.com Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for elect rical equipment for measurement, control, and laboratory use: • EN 55024, CISPR 24 EMC requireme nts • EN 55022, CISPR 22 Emissions; Class A • EN 55011, CISPR 11 ...

  • National Instruments FPT-1015 - page 21

    © National Instruments Corporation B-1 FPT-1015 User Manual B Display T iming Mode and OSD Supported Input T iming Modes The FPT -1015 supports and automatically recog nizes the frequencies listed in T able B-1. Note Even if you use the preset timing, you may need to adjust functions such as horizontal period, CLK-delay , and display pos ition. Th ...

  • National Instruments FPT-1015 - page 22

    Appendix B Display T iming Mode an d OSD FPT-1015 User Manu al B-2 ni.com Keypad Interface T able B-2 lists key functions. Power Indicator LED Status The ke ypad interface includes a dual-colo r LED dri ver to indicate status a s follows: • Green—The board detects an input signal and sends an output signal to the LCD panel. • Orange—No sign ...

  • National Instruments FPT-1015 - page 23

    Appendix B Display T iming Mode and OSD © National Instruments Corporation B-3 FPT-1015 User Manual OSD Function Each selected OSD function v alue is stored into LCD memory after an SEL signal input or timeout. The stored va lues are not af fected if the po wer is of f. Howe v er , the selected v alue is not av ailable if a selected mode is change ...

  • National Instruments FPT-1015 - page 24

    © National Instruments Corporation C-1 FPT-1015 User Manual C T ouchscreen This appendix explains ho w to install and configure the FPT -10 15 touchscreen. Introduction The FPT-1015 touchscreen uses advan ced 8-wire resistive technology, providing more accurate sensing capaci ty than other technologies. The touchscreen is specially designed for to ...

  • National Instruments FPT-1015 - page 25

    Appendix C T ouchscreen FPT-1015 User Manu al C-2 ni.com Standard Calibration When you click this button, arrows appear pointing to red squares. Use your finger or stylus to touch the red squares in sequence. After you touch the fifth red square, calibration is complete. T o skip, press <Esc>. Note T o access the Adv anced Calib ration opti o ...

  • National Instruments FPT-1015 - page 26

    Appendix C T ouchscreen © National Instruments Corporation C-3 FPT-1015 User Manual Follo w these steps to enable mult iple displays : 1. In the M ultiple Monitors tab, check the Multiple Monitor Support box. 2. Click Map T ouch Scr eens to assign touch controllers to the displays. 3. When the mapping screen message appears, click OK . 4. T ouch e ...

  • National Instruments FPT-1015 - page 27

    Appendix C T ouchscreen FPT-1015 User Manu al C-4 ni.com Click on T ouch—This option all ows the mouse to have only a click function, and dragging is disabled. Beep Sound Mode Enable Beep Sound—Th is option turns the beep function on and off. Beep on Pen Do wn—In this mode, the beep occurs when the pen goes do wn. Beep on Pen Up—I n this mo ...

  • National Instruments FPT-1015 - page 28

    Appendix C T ouchscreen © National Instruments Corporation C-5 FPT-1015 User Manual Configuring the Rotate Function Follow these steps to configu re the rotate function: 1. Install the rotation software package. 2. Choose the rotat e function in the softw are. The calibration screen appears automatically . T ouch the point, an d rotation is mapped ...

  • National Instruments FPT-1015 - page 29

    Appendix C T ouchscreen FPT-1015 User Manu al C-6 ni.com PenMount Monitor Menu Icon The PenMount Monitor icon ( pm ) appears in the Windows menu bar when you turn on PenMount Monit or in PenMount USB Utilities. PenMount Monitor has the following functions: Control Panel Brings up the PenMount Control Panel. Beep T urns the beep on or of f. Right Bu ...

  • National Instruments FPT-1015 - page 30

    © National Instruments Corporatio n D-1 FPT -1015 User Manual D T echnical Support and Professional Ser vices Visit the following sections of the National Instruments Web site at ni.com for technical support an d professional services: • Support —Online technical support resources at ni.com/support include the following: – Self-Help Resource ...

  • National Instruments FPT-1015 - page 31

    © National Instruments Corporation I-1 FPT-1015 User Manual Index A About function, C-5 adv anced calibration, C-2 C Calibrate function, C-1 calibration adv anced, C-2 plot calibration data, C-2 standard, C-2 CE compliance specif ications, A-6 cleaning, A-6 connectors, 1-1 DC 12 V power in, 1-2 USB type B touchscreen connector, 1-2 VGA port (DB15) ...

  • National Instruments FPT-1015 - page 32

    Index FPT-1015 User Manu al I-2 ni.com mounting, 2-1 desktop stand mounting , 2-6 panel mounting, 2 -4 po wer adapter mounting, 2-6 rack mounting, 2-5 wall mounting, 2-3 OSD function, B-3 menus (table), B-3 PenMount Monitor menu icon, C-6 PenMount rot ating functions, C-4 configuring, C-5 physical specifications, A-1 po wer adapter specif ications, ...

  • National Instruments FPT-1015 - page 33

    Index © National Instruments Corporation I-3 FPT-1015 User Manual PenMount Monitor menu icon, C-6 PenMount rot ating functions, C-4 configuring, C-5 physical specifications, A-1 plot calibration data, C-2 po wer adapter mounting, 2-6 specifications, A-4 po wer indicator LED status, B-2 programming examples (NI resources), D-1 R rack mounting, 2-5 ...

Manufacturer National Instruments Category Camera Accessories

Documents that we receive from a manufacturer of a National Instruments FPT-1015 can be divided into several groups. They are, among others:
- National Instruments technical drawings
- FPT-1015 manuals
- National Instruments product data sheets
- information booklets
- or energy labels National Instruments FPT-1015
All of them are important, but the most important information from the point of view of use of the device are in the user manual National Instruments FPT-1015.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals National Instruments FPT-1015, service manual, brief instructions and user manuals National Instruments FPT-1015. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product National Instruments FPT-1015.

A complete manual for the device National Instruments FPT-1015, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use National Instruments FPT-1015 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of National Instruments FPT-1015.

A complete National Instruments manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual National Instruments FPT-1015 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the National Instruments FPT-1015, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the National Instruments FPT-1015, that we can find in the current document
3. Tips how to use the basic functions of the device National Instruments FPT-1015 - which should help us in our first steps of using National Instruments FPT-1015
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with National Instruments FPT-1015
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of National Instruments FPT-1015 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning National Instruments FPT-1015?

Use the form below

If you did not solve your problem by using a manual National Instruments FPT-1015, ask a question using the form below. If a user had a similar problem with National Instruments FPT-1015 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)