Summary
  • Napoleon Fireplaces BGP42 - page 1

    1 W415-0381 / H / 12.07.07 W415-0381 / H / 12.07.07 $10.00 ...

  • Napoleon Fireplaces BGP42 - page 2

    2 W415-0381 / H / 12.07.07 20-22 FINISHING Door , Louvre & Panel Removal & Installation Grate Installation Log Placement / Glowing Embers V ermiculite Charcoal Embers Charcoal Lumps 22 OPTIONAL BL OWER INST ALLA TION 22-23 OPTIONAL F AN INST ALLA TION / GD36 THERMOSTATIC SENSOR CON- TROL 23 OPERA TION / MAINTENANCE Operating Instructions Ma ...

  • Napoleon Fireplaces BGP42 - page 3

    3 W415-0381 / H / 12.07.07 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test ...

  • Napoleon Fireplaces BGP42 - page 4

    4 W415-0381 / H / 12.07.07 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BGD42 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practices vary from region to region and it is important t ...

  • Napoleon Fireplaces BGP42 - page 5

    5 W415-0381 / H / 12.07.07 FIGURE 1 INST ALLA TION O VERVIEW FIGURE 2 ...

  • Napoleon Fireplaces BGP42 - page 6

    6 W415-0381 / H / 12.07.07 A terminal shall not terminate dir ectly abov e a sidewalk or pav ed drivew ay which is loca ted between two single f amily dwellings and serves both dw ellings . Local codes or regula tions may requir e dif fer ent clear ances . Do not allow the inside liner to bunc h up on horizontal or ver- tical runs and elbows . Keep ...

  • Napoleon Fireplaces BGP42 - page 7

    7 W415-0381 / H / 12.07.07 MINIMUM AIR TERMINAL L OCA TION CLEARANCES 32 32 32 32 32 32 4 Using a soffit heat shield (W585-0096), or equivalent, the distance may be reduced to a minimum of 18”. It is recommended to maximize the distance to the vinyl clad soffits. ** FIGURE 3 ...

  • Napoleon Fireplaces BGP42 - page 8

    8 W415-0381 / H / 12.07.07 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading is completed, the bottom air slot is located a minimum of 12" above grade. FIGURES 4 a-b FIGURE 5 TYPICAL VENT INST ALLA TIONS NO TE: When ter minating v er tically , the restrictor plat ...

  • Napoleon Fireplaces BGP42 - page 9

    9 W415-0381 / H / 12.07.07 VER TICAL TERMINA TION HORIZONT AL TERMINA TION vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical rise is equal to or greater than the horizontal run horizontal run + v erti- cal rise to maximum of 40 feet vertical rise is less than horizontal run ...

  • Napoleon Fireplaces BGP42 - page 10

    10 W415-0381 / H / 12.07.07 ELBOW VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMIN A TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE6 45º FIGURE 7 90° H 1 H 2 when (H T ) < (V T ) Simple venting confi guration (only one 45º and 90° elbow) for the following symbols used in the ...

  • Napoleon Fireplaces BGP42 - page 11

    11 W415-0381 / H / 12.07.07 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 8 REQUIRED VERTICAL RISE I ...

  • Napoleon Fireplaces BGP42 - page 12

    12 W415-0381 / H / 12.07.07 90° 90° V 1 H 1 H 2 V 2 45° 90° 45° VERTICAL TERMIN A TION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 1 ...

  • Napoleon Fireplaces BGP42 - page 13

    13 W415-0381 / H / 12.07.07 H 1 VERTICAL TERMIN A TION For vent confi gurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 feet when (H T ) > (V T ) Simple venting confi gurations See graph to determine the required vertical rise V T for the required ...

  • Napoleon Fireplaces BGP42 - page 14

    14 W415-0381 / H / 12.07.07 1. Determine the air terminal location, cut and frame 10 3/4" square openings in the ceiling and the roof to provide the minimum 1" clear- ance between the vent pipe and any combustible material. T ry to center the vent pipe location midway between two joist to prevent having to cut them. Use a plumb bob to lin ...

  • Napoleon Fireplaces BGP42 - page 15

    15 W415-0381 / H / 12.07.07 DO NOT CLAMP THE FLEXIBLE LINER FIGURE 24b 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an al- ternate method suitable to the authority having jurisdiction or the optional roof support. 2. Stretch the in ...

  • Napoleon Fireplaces BGP42 - page 16

    16 W415-0381 / H / 12.07.07 FIGURE 25 5. Remove nails from the shingles, above and to the sides of the chimney . Place the fl ashing over the air terminal connector leaving a min. 3/4” of the air terminal connector showing above the top of the fl ashing. Slide the fl ashing underneath the sides and upper edge of the shingles. Ensure that the a ...

  • Napoleon Fireplaces BGP42 - page 17

    17 W415-0381 / H / 12.07.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 21. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 3. Apply hig ...

  • Napoleon Fireplaces BGP42 - page 18

    18 W415-0381 / H / 12.07.07 FIGURE 33 This Mobile/Manufactured Home Listed appliance comes factory equipped with a means to secure the unit. The fi replace is equippe d with two 1/4" diameter holes located in the front left and right corners of the base. For mobile home installations, the fi replace must be fastened in place. Use #10 hex hea ...

  • Napoleon Fireplaces BGP42 - page 19

    19 W415-0381 / H / 12.07.07 FIGURE 34 FIGURES 36a-c TOP SLOT FINISHING MA TERIAL CORNER POST NAILING TA B A B C CENTRE HOLE NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner po ...

  • Napoleon Fireplaces BGP42 - page 20

    20 W415-0381 / H / 12.07.07 MINIMUM MANTEL AND ENCLOSURE CLEARANCES FIGURES 37a FIGURES 37b Combustible mantel clearance can vary according to the mantel depth. FIGURE 36. Use the graph to help evaluate the clearance needed. Curtains, above the fi replace, must not be positioned lower than the 5" distance required for the 2" combustible ...

  • Napoleon Fireplaces BGP42 - page 21

    21 W415-0381 / H / 12.07.07 Remove the backing of the logo supplied and place on the glass view- ing door , as indicated. FIGURE 40 LOG O ½" ½" LOGO PLA CEMENT PORCELAIN REFLECTIVE P ANELS 1. Remove the upper louvres, and open the glass door . Remove the logs. 2. Remove the two securing screws located on either fi rebox side. 3. Place ...

  • Napoleon Fireplaces BGP42 - page 22

    22 W415-0381 / H / 12.07.07 FIGURE 44 FIGURE 48 FIGURE 49 FIGURE 45 FIGURE 50 INST ALLA TION T O BE DONE BY A QUALIFIED INST ALLER and must be electrically con- nected and grounded in ac- cordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NATIONAL ELECTRICAL C ...

  • Napoleon Fireplaces BGP42 - page 23

    23 W415-0381 / H / 12.07.07 Unplug the power cord from the receptacle. Connect all wires as shown. Attach and secure the sen- sor assembly bracket to the securing stud located next to the receptacle/ junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the fi rebox wall. Plug the power ...

  • Napoleon Fireplaces BGP42 - page 24

    24 W415-0381 / H / 12.07.07 FIGURE 57 Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minutes for the fi nal fl ame colour to be established ...

  • Napoleon Fireplaces BGP42 - page 25

    25 W415-0381 / H / 12.07.07 # P ART NO. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE** 4 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0801 PROP ANE GAS PILOT ASSEMBL Y 5 W455-0069 NA TURAL GAS PILOT INJECTOR 5 W455-0067 PROP ANE GAS PILOT INJECTOR 6 W725-0025 NA TURAL GAS V AL VE 6 W725-0026 PROP ANE V AL V ...

  • Napoleon Fireplaces BGP42 - page 26

    26 W415-0381 / H / 12.07.07 ...

  • Napoleon Fireplaces BGP42 - page 27

    27 W415-0381 / H / 12.07.07 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button igniter . - check if the push button igniter needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. - replace ...

  • Napoleon Fireplaces BGP42 - page 28

    28 W415-0381 / H / 12.07.07 White / grey film forms. Sulphur from fuel is being depos- ited on glass, logs or combustion chamber surfaces. - clean the glass with a recommended gas fi replace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned off regularly , the glass may become permanently marked. Main burner fl ame is a bl ...

Manufacturer Napoleon Fireplaces Category Outdoor Fireplace

Documents that we receive from a manufacturer of a Napoleon Fireplaces BGP42 can be divided into several groups. They are, among others:
- Napoleon Fireplaces technical drawings
- BGP42 manuals
- Napoleon Fireplaces product data sheets
- information booklets
- or energy labels Napoleon Fireplaces BGP42
All of them are important, but the most important information from the point of view of use of the device are in the user manual Napoleon Fireplaces BGP42.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Napoleon Fireplaces BGP42, service manual, brief instructions and user manuals Napoleon Fireplaces BGP42. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Napoleon Fireplaces BGP42.

A complete manual for the device Napoleon Fireplaces BGP42, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Napoleon Fireplaces BGP42 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Napoleon Fireplaces BGP42.

A complete Napoleon Fireplaces manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Napoleon Fireplaces BGP42 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Napoleon Fireplaces BGP42, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Napoleon Fireplaces BGP42, that we can find in the current document
3. Tips how to use the basic functions of the device Napoleon Fireplaces BGP42 - which should help us in our first steps of using Napoleon Fireplaces BGP42
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Napoleon Fireplaces BGP42
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Napoleon Fireplaces BGP42 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Napoleon Fireplaces BGP42?

Use the form below

If you did not solve your problem by using a manual Napoleon Fireplaces BGP42, ask a question using the form below. If a user had a similar problem with Napoleon Fireplaces BGP42 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)