  • Empire Comfort Systems BF-10-2 - page 1

    INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL UNVENTED ROOM HEA TER MODELS BF-10-2 BF-20-2 BF-30-2 W ARNING: If not installed, operated and ma in ta in ed in acc or da nc e with the man uf ac tu r - er's instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness. Th ...

  • Empire Comfort Systems BF-10-2 - page 2

    16943-7-0907 Page 2 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas ...................................................................................................... 4 Introduction .......... ...

  • Empire Comfort Systems BF-10-2 - page 3

    16943-7-0907 Page 3 THIS IS A HEA TING APPLIANCE DO NOT OPERA TE THIS APPLIANCE WITHOUT FRONT P ANEL INST ALLED. • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented r oom heater having an input rating of mor e than 10,000 Btu per hour shall not be installed in a b ...

  • Empire Comfort Systems BF-10-2 - page 4

    16943-7-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can af fect your sensitivity or ability to detect that odor . Sometimes other odors in the are ...

  • Empire Comfort Systems BF-10-2 - page 5

    16943-7-0907 Page 5 Qualified Installing Agency Installation and replacement of gas piping, gas utilization equip - ment or accessories and repair and servicing of equipment shall be performed only by a qualified agency . The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a ...

  • Empire Comfort Systems BF-10-2 - page 6

    16943-7-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 Btu (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat app ...

  • Empire Comfort Systems BF-10-2 - page 7

    16943-7-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, especially for the size and type of gas supply ...

  • Empire Comfort Systems BF-10-2 - page 8

    16943-7-0907 Page 8 SRS-18* and SRS-30 Floor Stand Installation 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 5. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line. * SRS-18 floor stand can not be used in a bedroom installation. BF-10 must be wall ...

  • Empire Comfort Systems BF-10-2 - page 9

    16943-7-0907 Page 9 On Sheet Rock W all 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) plastic expansion anchors provided into the holes. 3. T ighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors. Do not completely tighten screwheads to the plastic expansion anc ...

  • Empire Comfort Systems BF-10-2 - page 10

    16943-7-0907 Page 10 T O TURN OFF GAS T O APPLIANCE 1. STOP! Read the safety information above. 2. Set thermostat (gas control knob) to lowest setting. 3. T urn off all electric power to the appliance (if applicable). 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. W ait ten (10) minutes to clear out any ...

  • Empire Comfort Systems BF-10-2 - page 11

    16943-7-0907 Page 1 1 Piezo Pilot Ignitor Instructions Depressing the ignitor button completely causes a spark to occur at the pilot. T o light the pilot, it is important that the electrode be 1/8" (3mm) from the pilot. The spark must occur at the point the pilot flame hits the thermocouple. On a new installation with air in the gas line, it ...

  • Empire Comfort Systems BF-10-2 - page 12

    16943-7-0907 Page 12 The correct flame will be blue and will extend beyond the thermo- couple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 1 1 Oxygen Depletion Sensor Pilot (Figur e 12) When the pilot has a large yellow tip flame, clean t ...

  • Empire Comfort Systems BF-10-2 - page 13

    16943-7-0907 Page 13 Glass Removal, Cleaning and Glass Replacement 1. Remove chrome grill from reflector . 2. Slide glass upward to remove glass from chrome grill. 3. Clean glass with a non-abrasive household glass cleaner and warm water . Gas fireplace glass cleaner can also be used. 4. Align glass with rails on chrome grill and slide glass down ...

  • Empire Comfort Systems BF-10-2 - page 14

    16943-7-0907 Page 14 1. Spark electrode does not pr oduce spark. a. Spark electrode broken - replace. b. Ignitor wire ma y not be attache d to spa rk elect rode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode pr oduces spark but pilot does not light. a. No gas to heater - turn on gas. b. PILOT p ...

  • Empire Comfort Systems BF-10-2 - page 15

    16943-7-0907 Page 15 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. P AR TS LIST 1 13347 CASING SIDE ASSEMBL Y - LEFT (BF-10 ) 1 13348 CASING SIDE ASSEMBL Y - LEFT (BF-20, BF-30) 2 SR ...

  • Empire Comfort Systems BF-10-2 - page 16

    16943-7-0907 Page 16 P AR TS VIEW ...

  • Empire Comfort Systems BF-10-2 - page 17

    16943-7-0907 Page 17 INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on SRS-18 or SRS-30 optional floor stand there is adequate access area available to install the optional blower . 1. T urn "OFF" ...

  • Empire Comfort Systems BF-10-2 - page 18

    16943-7-0907 Page 18 P ARTS LIST Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri- cal Code, ANSI/NFP A 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protec - tio ...

  • Empire Comfort Systems BF-10-2 - page 19

    16943-7-0907 Page 19 SER VICE NOTES ...

  • Empire Comfort Systems BF-10-2 - page 20

    16943-7-0907 Page 20 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

Manufacturer Empire Comfort Systems Category Electric Heater

Documents that we receive from a manufacturer of a Empire Comfort Systems BF-10-2 can be divided into several groups. They are, among others:
- Empire Comfort Systems technical drawings
- BF-10-2 manuals
- Empire Comfort Systems product data sheets
- information booklets
- or energy labels Empire Comfort Systems BF-10-2
All of them are important, but the most important information from the point of view of use of the device are in the user manual Empire Comfort Systems BF-10-2.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Empire Comfort Systems BF-10-2, service manual, brief instructions and user manuals Empire Comfort Systems BF-10-2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Empire Comfort Systems BF-10-2.

A complete manual for the device Empire Comfort Systems BF-10-2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Empire Comfort Systems BF-10-2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Empire Comfort Systems BF-10-2.

A complete Empire Comfort Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Empire Comfort Systems BF-10-2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Empire Comfort Systems BF-10-2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Empire Comfort Systems BF-10-2, that we can find in the current document
3. Tips how to use the basic functions of the device Empire Comfort Systems BF-10-2 - which should help us in our first steps of using Empire Comfort Systems BF-10-2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Empire Comfort Systems BF-10-2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Empire Comfort Systems BF-10-2 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Empire Comfort Systems BF-10-2?

Use the form below

If you did not solve your problem by using a manual Empire Comfort Systems BF-10-2, ask a question using the form below. If a user had a similar problem with Empire Comfort Systems BF-10-2 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)