Manual ADTRAN T200 IDSL

18 pages 0.14 mb
Download

Go to site of 18

Summary
  • ADTRAN T200 IDSL - page 1

    1 61220010L2-5, Issue 3 61220010L2-5C Section 61220010L2-5C Issue 3, April 2001 CLEI # NCT1TX2B _ _ T200 IDSL OCU-R Remote T ermination Unit Installation and Maintenance Trademarks: Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective holders. 1. GENERAL This practice ...

  • ADTRAN T200 IDSL - page 2

    2 61220010L2-5, Issue 3 61220010L2-5C 2. OPTIONS Options and rate are selected with the front panel DIP switches as shown in Figure 1 and listed in Table 1. Customer Interface Transmit Line Build Out When -10 dB (SW1-1) is ON, the IDSL OCU-R transmits a -10 dB AMI signal across the 4-wire customer interface toward the CSU/DSU. When OFF is selected ...

  • ADTRAN T200 IDSL - page 3

    3 61220010L2-5, Issue 3 61220010L2-5C C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. Quality Monitor (QM) When QM (SW1-2) is ON, the IDSL OCU-R monitors the customer interface for errors. If excessive errors are detected the unit blocks customer data transmission and sends Abnormal Station ...

  • ADTRAN T200 IDSL - page 4

    4 61220010L2-5, Issue 3 61220010L2-5C Wiring The ADTRAN IDSL OCU-R may be mounted in any standard T400/T200 housing, or the following ADTRAN T400/T200 housings: CAUTION On span-powered units, ensure ground continuity exists between the unit, the housing, and a known approved ground source. Span Power Applications • Single Mount Housing P/N 121200 ...

  • ADTRAN T200 IDSL - page 5

    5 61220010L2-5, Issue 3 61220010L2-5C LED Indication The IDSL OCU-R front panel LEDs display the operating status. The LEDs are described in Table 5 . 4. TESTING Loopback Testing Loopback tests can be performed from the Central Office (CO) to verify proper loop and IDSL OCU-R operation. The IDSL OCU-R provides a network loopback in response to an O ...

  • ADTRAN T200 IDSL - page 6

    6 61220010L2-5, Issue 3 61220010L2-5C IDSL/DDS Trouble Code The IDSL/DDS system provides a quick diagnosis in the case of a circuit condition where continuity is broken when the IDSL/DDS circuit uses ADTRAN U- BR1TEs with DDS Loopback capability in the central office or remote terminal. The trouble code type received by a tester determines whether ...

  • ADTRAN T200 IDSL - page 7

    7 61220010L2-5, Issue 3 61220010L2-5C All existing latching loopbacks can also be disabled by pressing the TEST or LBK pushbutton on the U-BR1TE or remote unit, respectively. NOTE The remote end test feature is only supported when the upstream U-BR1TE is an ADTRAN D4 or Series 5 U-BR1TE with DDS Loopback capability. Other U-BR1TEs will ignore the l ...

  • ADTRAN T200 IDSL - page 8

    8 61220010L2-5, Issue 3 61220010L2-5C Table 8. Definition of Screen Abbreviations Abbreviation and Definition ES – Error ed Seconds: A count of the number of seconds in which at least one code violation was detected on a  digital circuit.  • IDSL Interface ....Second in which a CRC error occurs.  • Customer DDS Interface. ...

  • ADTRAN T200 IDSL - page 9

    9 61220010L2-5, Issue 3 61220010L2-5C To conduct a terminal session, connect a VT100 or compatible test set to the OCU-R via the front panel DB-9 connector, then press the space bar three times to initiate the session. The Main Menu will appear, as illustrated in Figure 9 . The Main Menu provides access to detailed performance and configuration inf ...

  • ADTRAN T200 IDSL - page 10

    10 61220010L2-5, Issue 3 61220010L2-5C Figure 11 shows the System Status screen. Figure 12 shows Detailed Status for both network and customer loops. Figure 11. System Status Screen CIRCUIT ID:IDSL Test Unit 07/25/00 02:31:30 System Status Screen Channel Bank DDS Loop ____________ ____________ | UBR1TE | | OCU-R | | | | |------> | | | | | | | | ...

  • ADTRAN T200 IDSL - page 11

    11 61220010L2-5, Issue 3 61220010L2-5C Figure 13 shows the Loopbacks display, allowing loopback testing to be initiated or terminated while graphically displaying the testing status of the IDSL system. Latching Loopback Timeout When latching loopback timeout is enabled, latching loopbacks will drop out after 120 minutes returning the system to norm ...

  • ADTRAN T200 IDSL - page 12

    12 61220010L2-5, Issue 3 61220010L2-5C Clearing PM and Event Log Registers Press “5” at the Performance Monitoring screen (Figure 14) to advance to the Warning screen (not shown). At the Warning screen the user will be prompted to clear registers; “Y” for Yes or “N” for No. Figure 15. U-BR1TE 15-Minute Performance Monitoring Screen Inte ...

  • ADTRAN T200 IDSL - page 13

    13 61220010L2-5, Issue 3 61220010L2-5C Figure 17. Frame Relay 15-Minute Performance Monitoring Screen Figure 18. Frame Relay 24-Hour Performance Monitoring Screen CIRCUIT ID:IDSL Test Unit 07/25/00 02:37:18 Frame Relay 15-Minute Registers IDSL INTERFACE DDS LOOP -INV--FECN--BECN---LMI--%UT -INV--FECN--BECN---LMI--%UT 00000 00000 00000 00000 000 000 ...

  • ADTRAN T200 IDSL - page 14

    14 61220010L2-5, Issue 3 61220010L2-5C The Event Log, shown in Figure 19 , loads and time- stamps IDSL circuit performance anomalies and threshold violations. This screen is a very useful aid in troubleshooting a chronic circuit. It monitors DDS sync loss, DDS open loop, IDSL OCU-R margin, IDSL sync loss, and power-up events. IDSL loop signal-to-no ...

  • ADTRAN T200 IDSL - page 15

    15 61220010L2-5, Issue 3 61220010L2-5C The Set Date and Time screen, Figure 21 , may be used to set the IDSL OCU-R date and time. Once the date and time are configured the performance registers date and time update accordingly. The ADTRAN Information screen, Figure 22 , displays part number, serial number, CLEI code, and unit revision for the IDSL ...

  • ADTRAN T200 IDSL - page 16

    16 61220010L2-5, Issue 3 61220010L2-5C 6. REMOTE PROVISIONING AND DIAGNOSTICS Control Protocol Remote access to provisioning and status information is accomplished using ADTRAN Digital System 6 Message protocol, defined in Control and Diagnostic Procedures Practice, Section 6032991-6. Digital System 6 is supported by the TPI 108/109 and 105 portabl ...

  • ADTRAN T200 IDSL - page 17

    17 61220010L2-5, Issue 3 61220010L2-5C For service, CAPS requests, or further information, contact one of the following numbers: ADTRAN Sales Pricing/Availability (800) 827-0807 ADTRAN Technical Support Pre-sales Applications/Post-sales Technical Assistance (800) 726-8663 Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CST Emergency hours: 7 days/we ...

  • ADTRAN T200 IDSL - page 18

    18 61220010L2-5, Issue 3 61220010L2-5C ...

Manufacturer ADTRAN Category Network Card

Documents that we receive from a manufacturer of a ADTRAN T200 IDSL can be divided into several groups. They are, among others:
- ADTRAN technical drawings
- T200 IDSL manuals
- ADTRAN product data sheets
- information booklets
- or energy labels ADTRAN T200 IDSL
All of them are important, but the most important information from the point of view of use of the device are in the user manual ADTRAN T200 IDSL.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals ADTRAN T200 IDSL, service manual, brief instructions and user manuals ADTRAN T200 IDSL. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product ADTRAN T200 IDSL.

A complete manual for the device ADTRAN T200 IDSL, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use ADTRAN T200 IDSL by users. Manuals are usually written by a technical writer, but in a language understandable to all users of ADTRAN T200 IDSL.

A complete ADTRAN manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual ADTRAN T200 IDSL - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the ADTRAN T200 IDSL, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the ADTRAN T200 IDSL, that we can find in the current document
3. Tips how to use the basic functions of the device ADTRAN T200 IDSL - which should help us in our first steps of using ADTRAN T200 IDSL
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with ADTRAN T200 IDSL
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of ADTRAN T200 IDSL in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning ADTRAN T200 IDSL?

Use the form below

If you did not solve your problem by using a manual ADTRAN T200 IDSL, ask a question using the form below. If a user had a similar problem with ADTRAN T200 IDSL it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)