    Shop online at FMG-3000 S ERIES Blind version Magmeter U ser ’ s Guide ome ga.com om e g a .c om TM ® www .omega.com e-mail: http://omegamanual.info For latest information and product manual visit www .omegamanual.info. ISO 9001 CERTIFIED CORPORA TE QUALITY ST AMFORD , CT ISO 9002 CERTIFIED CORPORA TE QUALITY MANCHESTER, UK ...

  • Omega FMG3000 - page 2

    It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certifi cation of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certifi cation. The information contained in this document is believed to be correct, but ...

  • Omega FMG3000 - page 3

    1 1 2 3 4 JP2 FREQUENCY OUT DO NOT REMOVE Connect output signals and power to this 4-terminal block. 2. 4. 3. 3. Sensor T ype Pipe Size Jumper Position ½ in. to 2½ in. FMG3001 DN15 to DN65 FMG3002 3 in. to 4 in. DN80 to DN100 FMG3101 5 in. to 6 in. FMG3102 DN125 to DN150 8 in. DN200 FMG3201 10 in. to 12 in. FMG3202 DN250 to DN300 1. Omega FMG-300 ...

  • Omega FMG3000 - page 4

    2 SAFETY INSTRUCTIONS 1. Depressurize and vent system prior to installation or removal. 2. Confi rm chemical compatibility before use. 3. Do not exceed maximum temperature/pressure specifi cations. 4. Wear safety goggles or face shield during installation/service. 5. Do not alter product construction. 6. Disconnect power before attempting any ser ...

  • Omega FMG3000 - page 5

    3 4. Selecting a Location • The FMG-3000 requires a full pipe and a fully developed turbulent fl ow profi le for accurate measurement. • If the piping system harbors air pockets or bubbles, take steps to locate the sensor so the air pockets will not contact the electrodes. • In vertical installations, assemble the unit so the conduit ports ...

  • Omega FMG3000 - page 6

    4 Important: • The directional arrow on the body of the sensor must be pointed DOWNSTREAM. • The FLOW arrow decal can be placed directly on the pipe to identify the direction of fl ow . • Use a cable gland or a liquid tight connector to seal the cable ports from water intrusion. • The yellow housing may be reversed to align the conduit por ...

  • Omega FMG3000 - page 7

    5 6. General Installation and Grounding Tips Sensor conditioning The Magmeter output signal may be unstable immediately after installation. Allowing the sensor to soak in a full pipe (or in a ny container of water) for 24 hours will stabilize the performance. • V ery low conductivity fl uids may require a longer conditioning period. (The Magmete ...

  • Omega FMG3000 - page 8

    6 • The FMG-3001 and FMG-3101 Magmeters output an open collector frequency signal. • A 10 K Ω pull up resistor must be connected between terminals 1 and 2 if the magmeter is used with third-party equipment.. 8. Wiring the FMG-3001 and FMG-3101 with Frequency output 1 2 3 4 5-24 VDC Ground Not used Frequency Out Magmeter 10K Ω Install a pull ...

  • Omega FMG3000 - page 9

    7 9. Calibration Data: K-factors* and Full Scale Current V alues Plastic Installation Fittings: PVC T ees and Saddles PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM SCH 80 PVC TEES FOR SCH 80 PVC PIPE ½ FP-5305 2289.37 604.85 13.10 49.60 ¾ FP-5307 1430.41 377.92 20.97 79.38 1 FP-5310 876.86 231.67 34.21 ...

  • Omega FMG3000 - page 10

    8 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM POL YPROPYLENE FITTINGS (DIN/ISO ,BS, ANSI) ½ FP-5105PO 2192.73 579.32 13.68 51.78 ¾ FP-5107PO 1327.81 350.81 22.59 85.52 1 FP-51 10PO 737.16 194.76 40.70 154.04 1¼ FP-51 12PO 453.46 1 19.81 66.16 250.41 1½ FP-51 15PO 275.03 72.66 109.08 412.86 2 FP-512 ...

  • Omega FMG3000 - page 11

    9 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM CARBON STEEL TEES ON SCH 40 PIPE ½ FMG-5305CS 1572.66 415.50 19.08 72.20 ¾ FMG-5307CS 1086.73 287.1 1 27.61 104.49 1 FMG-5310CS 582.34 153.86 51.52 194.99 1¼ FMG-5312CS 377.48 99.73 79.48 300.81 1½ FMG-5315CS 267.79 70.75 1 12.03 424.02 2 FMG-5320CS 167 ...

  • Omega FMG3000 - page 12

    10 PIPE SIZE FITTING K-Factor K-Factor 20 mA= 20 mA= (IN.) TYPE Gallons Liters* in GPM in LPM BRONZE TEES ON SCH 40 PIPE 1 FP-5310BR 582.34 153.86 51.52 194.99 1¼ FP-5312BR 330.54 87.33 90.76 343.53 1½ FP-5315BR 254.76 67.31 1 17.76 445.71 2 FP-5320BR 157.36 41.58 190.64 721.58 COPPER TEES FITTING ON COPPER PIPE SCH K ½ FP-5305CU 2459.19 649.72 ...

  • Omega FMG3000 - page 13

    11 • Conductivity is less than 20 µS/cm. • Electronic component failure. • 4-20 mA is not scaled same as Loop device. • Loop device is not scaled same as Magmeter . • Range Jumper not placed correctly . • Defective Magmeter • Magmeter installed too close to upstream obstruction. • Magmeter electrodes are coated with solids. • Mag ...

  • Omega FMG3000 - page 14

    12 1 1. Ordering Information OMEGAMAG with Frequency Output FMG3001-PP OMEGAMAG, Blind, Freq, PP/316SS, ½-4 FMG3101-PP OMEGAMAG, Blind, Freq, PP/316SS, 5-8 FMG3201-PP OMEGAMAG, Blind, Freq, PP/316SS,10-12 FMG-3001-PVDF-HA OMEGAMAG, Blind, Freq, PVDF/Hast, ½-4 FMG3101-PVDF-HA OMEGAMAG, Blind, Freq, PVDF/Hast, 5-8 FMG3201-PVDF-HA OMEGAMAG, Blind, F ...

  • Omega FMG3000 - page 15

    W ARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA ’s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’s customers ...

  • Omega FMG3000 - page 16

    6-2551.090-OM (C-4/07) M-4210/0407 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www .omega.com TEMPERATURE • Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies • Wire: Thermocouple, RTD & Thermistor • Calibrators & Ice Point References • Recorder ...

Manufacturer Omega Category Camera Accessories

Documents that we receive from a manufacturer of a Omega FMG3000 can be divided into several groups. They are, among others:
- Omega technical drawings
- FMG3000 manuals
- Omega product data sheets
- information booklets
- or energy labels Omega FMG3000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega FMG3000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega FMG3000, service manual, brief instructions and user manuals Omega FMG3000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega FMG3000.

A complete manual for the device Omega FMG3000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega FMG3000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega FMG3000.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega FMG3000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega FMG3000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega FMG3000, that we can find in the current document
3. Tips how to use the basic functions of the device Omega FMG3000 - which should help us in our first steps of using Omega FMG3000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega FMG3000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega FMG3000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega FMG3000?

Use the form below

If you did not solve your problem by using a manual Omega FMG3000, ask a question using the form below. If a user had a similar problem with Omega FMG3000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)