Manual Whistler 205563

15 pages 0.17 mb
Download

Go to site of 15

Summary
  • Whistler 205563 - page 1

    OWNER’S MANUAL 200/400 W A TT POWER INVERTERS THE WHISTLER GROUP , INC. CORPORA TE HEADQUARTERS 13016 N. W alton Blvd. Bentonville, AR 72712 TEL (479) 273-6012 FX (479) 273-2927 www .whistlergroup.com CUSTOMER RETURN CENTER 1201 N. Dixieland Rd. Rogers, AR 72756 Consumer Relations T el (800) 531-0004 Email: info@whistlergr oup.com P/N 205563 © 2 ...

  • Whistler 205563 - page 2

    1 If you have questions concerning the operation of this Whistler product please call customer service: 1-800-531-0004 Hours: Monday - Friday 8:00 am - 5:00 pm CT or visit www .whistlergr oup.com Please keep the receipt in a safe place. Y ou may r egister your product online at www .whistlergr oup.com. If the unit is returned without a dated pr oof ...

  • Whistler 205563 - page 3

    A Wor d About WHISTLER Power Inverters. WHISTLER inverters convert low voltage, direct curr ent (DC) to 110 volt alternating household current (AC). The AC output is called “modified sine wave”. See “T echnical Operating Principles” section for more information. Depending on the model and its rated capacity , WHISTLER inverters draw power e ...

  • Whistler 205563 - page 4

    INVERTER BASICS Getting Started Power equipment and appliances which operate with motors or tubes requir e an initial surge of power to get them up and running. This power surge is r eferred to as the "starting load" or "peak load." (By comparison, electrical devices such as standard light bulbs do not r equire a lar ge starting ...

  • Whistler 205563 - page 5

    INVERTER BASICS Don’t Push It. Although your WHISTLER inverter has the capacity to pro- vide power output (excess current) equal to appr oximately two times its rated wattage capacity for a very brief period, it is designed to operate equipment and appliances with start up load wattage ratings no higher than its own maxi- mum continuous wattage r ...

  • Whistler 205563 - page 6

    OPERA TION Making the Connection. This inverter is designed to connect to your 12 volt battery using the light socket plug or by the supplied battery cables (for appliances over 150 watts* 400 watt model). Making The Connection. 1. Make certain that the inverter rocker switch is in the OFF (O) position. 2. Connect the lighter plug or hardwir e cabl ...

  • Whistler 205563 - page 7

    • The use of an extension cor d from the inverter to the appli- ance or equipment being operated will not significantly decrease the power being generated by the inverter . For best operating results, the extension cor d should be no more than 50 feet long. • Check fr equently to ensure that the input and output con- nections are secur e. Loose ...

  • Whistler 205563 - page 8

    13 ADDITIONAL FEA TURES Automatic Shut Down & Related Safety Features. Each inverter has an unique LED indicator warning light sys- tem which operates in conjunction with the automatic shut down feature . These indicator lights operate as follows: GREEN LED: System ready . RED LED: System overload/automatic shut down. YELLOW LED: Open fuse Y ou ...

  • Whistler 205563 - page 9

    2. Low Battery V oltage Alarm/Shutdown Protection a) When the input voltage from the 12 volt power sour ce drops below 10.5 volts, an audible tone will be hear d. This is the low battery voltage alarm. b) The inverter will automatically shut down when the input voltage drops below 9.5 volts. This pr otects the battery from completely draining. In t ...

  • Whistler 205563 - page 10

    17 16 OPERA TING PRINCIPLES OPERA TING PRINCIPLES majority of AC voltmeters are calibrated for RMS voltage and assume that the measured waveform will be a pur e sine wave. Consequently , these meters will not read the RMS modified sine wave voltage correctly and, when measuring your WHISTLER inverter output, the meters will read about 20 to 30 volt ...

  • Whistler 205563 - page 11

    • Befor e attempting to use medical equipment see page 4. • Use only fuses which conform with the design specifica- tions outlined in this manual. • When operating the inverter with the engine of f, start the engine every hour and let it run for at least 10 minutes to rechar ge the battery . • In the event of automatic shut down, turn the i ...

  • Whistler 205563 - page 12

    21 20 TROUBLESHOOTING TROUBLESHOOTING PROBLEM: Low Battery Alarm On All The Time Problem Solution Input voltage below Keep input voltage above 10.5 volts. 10.5 volts to maintain regulation. Poor or weak battery Replace battery . condition. Inadequate power being Use lower gauge wire. delivered to the inverter (400 watt model) or excessive voltage d ...

  • Whistler 205563 - page 13

    SPECIFICA TIONS 23 22 TROUBLESHOOTING PROBLEM: TV Does Not Work Problem Solutio n TV does not turn on T ry rocking the ON/OFF switch of the inverter while leaving the TV ON (see page 7). Contact TV manufacturer for start-up surge and/or to find out if TV is compatible with a modified sine wave. A larger inverter may be requir ed. WHISTLER 200 WA TT ...

  • Whistler 205563 - page 14

    W ARRANTY IMPORT ANT : Whistler will not assume responsibility for loss or damage incurred in shipping. Ther efore, please ship your unit insured with r eturn receipt requested. 2. Include with your unit the following information, clearly printed: • Y our name and street addr ess (for shipping via UPS), a daytime telephone number , (No P .O. Box ...

  • Whistler 205563 - page 15

    W ARRANTY Service Out Of W arranty Units will be repair ed at “out of warranty” service rates when: • The unit’ s original warranty has expired. • Dated store receipt is not supplied. • The unit has been returned without its serial number . • The unit has been abused, modified, installed improperly , or had its housing removed. The mi ...

Manufacturer Whistler Category Welding System

Documents that we receive from a manufacturer of a Whistler 205563 can be divided into several groups. They are, among others:
- Whistler technical drawings
- 205563 manuals
- Whistler product data sheets
- information booklets
- or energy labels Whistler 205563
All of them are important, but the most important information from the point of view of use of the device are in the user manual Whistler 205563.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Whistler 205563, service manual, brief instructions and user manuals Whistler 205563. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Whistler 205563.

Similar manuals

A complete manual for the device Whistler 205563, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Whistler 205563 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Whistler 205563.

A complete Whistler manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Whistler 205563 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Whistler 205563, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Whistler 205563, that we can find in the current document
3. Tips how to use the basic functions of the device Whistler 205563 - which should help us in our first steps of using Whistler 205563
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Whistler 205563
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Whistler 205563 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Whistler 205563?

Use the form below

If you did not solve your problem by using a manual Whistler 205563, ask a question using the form below. If a user had a similar problem with Whistler 205563 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)