Manual Agilent Technologies 16048A

21 pages 0.91 mb
Download

Go to site of 21

Summary
  • Agilent Technologies 16048A - page 1

    Agilent 1604 8A T est Leads Operation and Service Manual Fourth Edition Agilent T echnologi es Japan, Ltd. Agilent PN 160 48-9000 1 March 2 000 Print ed in: Japan ...

  • Agilent Technologies 16048A - page 2

    2 Notices The in format ion con tained in this docume nt is subjec t to ch ange withou t n otice. This docu ment contains p ropri etary infor mation that is p rotec ted by c opyright. All rights are rese rved. No p art of t his doc ument may be pho tocopi ed, rep roduced, or transl ated to a nother language wi thout the prior writ ten consent of t ...

  • Agilent Technologies 16048A - page 3

    3 • Ground The Instr ument T o avoid electri c shock hazard, t he inst rument chassi s and cabi net must be connecte d to a s afety ea rth gr ound by t he suppli ed power cable with ea rth blade. • DO NOT Operate In An E xplosi ve Atmosphere Do not oper ate the i nstr ument in the prese nce of fl ammable ga sses o r fumes. Operati on of any el ...

  • Agilent Technologies 16048A - page 4

    4 Wa r r a n t y This Ag ilent T echn ologie s inst rument product is war rante d against defec ts in materia l and workmans hip fo r a perio d corre sponding t o the indi vidual warranty periods of it s compone nt product s. Inst rument s are warr anted for a p eriod of o ne year . Fixtures and adapte rs ar e warrant ed for a peri od of 90 days . ...

  • Agilent Technologies 16048A - page 5

    5 Assistance Product ma intena nce agree ments an d other cus t omer a ssistan ce agreements are availa ble for Agilent T echnologi es produc ts. For any as sistance, conta ct your nearest Agilen t T echnologi es Sal es and Servi c e Off ice. Addres ses ar e provide d at t he back of t his manual . Safety S ymbol General definiti ons of safety s ym ...

  • Agilent Technologies 16048A - page 6

    6 ...

  • Agilent Technologies 16048A - page 7

    Contents 7 1. Operation Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 T ypical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Agilent Technologies 16048A - page 8

    8 Contents ...

  • Agilent Technologies 16048A - page 9

    9 1 Operation This oper ating no te prov ides co mplete i nformat ion on th e 16048A T est Le ads. The 16048A is s hown pic toriall y in Figur e 1-1, i ts physic al di mensions ar e given in T able 1-1, a nd typi cal char acteristics related to of fset error are give n in T able 1-2. T o order add ition al copies of th is operat ing not e, use the ...

  • Agilent Technologies 16048A - page 10

    10 Chapter 1 Operation Product Des cription Product Description The 16048A co nsists of a dir ect att achment, 4-terminal pair type fixture which is equip ped w ith f our BNC (m) termi nat ed-co axia l tes t lead s. Th ese te st lead s ar e used to a ttach use r -fabri cated test fi xture s. DC bias le vels of up to ±40 V can be applied to the 160 ...

  • Agilent Technologies 16048A - page 11

    Chapter 1 11 Oper ation Specifications Specifications T able 1-1 Specifications of the 16 048A Function: For use with 4 terminal-pair LCR Meters and Impedance Analy zers. Connector T ype: BNC male Cable Length: Approximately 1m Maximum V oltag e: ± 40V peak max. (AC+DC) W eight: 315 g Safety Stand ards: EN610 10-1:199 3 +A2:1995 IEC6 1010-1: 1990 ...

  • Agilent Technologies 16048A - page 12

    12 Chapter 1 Operation T ypica l Character istics T ypical Characteristics T able 1 -2 T ypical Ch aracteristic s NOTE f is the meas urem ent fr eque ncy in meg ahert z. The incr emen tal er rors c alcul ated from the equation i n the t able for measur ements at f requenci es above 1 MHz are additi ve. Figur e 1-2 Incremental erro r at freq. ³ 1 M ...

  • Agilent Technologies 16048A - page 13

    Chapter 1 13 Oper ation Compensation for Fixtur e Residual Impedance Error Compensation for Fixtur e R esidual Impedance Err or The 16048A ha s inherent stray c apacitan ce, residual in ductanc e, and res idual resist ance that af fect the accura cy of mea sured val ues. T o compe nsate for , or negate, t hese res idual s to minimiz e measur ement ...

  • Agilent Technologies 16048A - page 14

    14 Chapter 1 Operation Compensation for Fixture Residual Impedance Er ror ...

  • Agilent Technologies 16048A - page 15

    15 2 Service ...

  • Agilent Technologies 16048A - page 16

    16 Chapter 2 Serv ice Maintena nce Maintenance An explode d view of the 16 048A (for pa rts i dentifi catio n) is shown in Figure 2-1. Do not dis assemble any furt her than s hown. Maintenance consist s prin cipally o f cleani ng conta cts and r eplacing w orn or d amaged par ts. T ake spe cial car e when cleani ng conta cts. T o order parts, us e ...

  • Agilent Technologies 16048A - page 17

    Chapter 2 17 Service Maintenance Figur e 2-1 Parts Iden tificat ion ...

  • Agilent Technologies 16048A - page 18

    18 Chapter 2 Serv ice Maintena nce T able 2-1 Parts Id entification Reference Agilent Part No. Qty . Description Note 1 * 4 SLEEVE 2 * 4 NUT 3 * 4 NUT 4 * 4 W ASHER 5 * 4 W ASHER 6 2360-0 192 2 SCREW 7 * 1 COVER-BOTTOM 8 * 4 INSULA TOR 9 * 2 CONNECTOR-BNC 10 * 2 CONNECTOR-BNC 1 1 2200-0103 1 S CREW 12 219 0-0206 1 W ASHER 13 160 47-400 00 1 STO PPE ...

  • Agilent Technologies 16048A - page 19

    Chapter 2 19 Service Maintenance *: Not se parat ely repla ceable. 31 1250-01 18 4 CONNECTOR-BNC FEMALE 32 236 0-01 15 2 SCREW 1 thru 30 33 160 32-10021 1 P LA TE 34 219 0-0016 4 W ASHER 35 295 0-0001 4 NUT 36 160 32-10022 1 P LA TE 37 160 32-600 01 1 BNC BRA CKET 31thr u36 a. Agilent interna l -only par t number . Reference Agilent Part No. Qty . ...

  • Agilent Technologies 16048A - page 20

    20 Chapter 2 Serv ice Maintena nce ...

  • Agilent Technologies 16048A - page 21

    REGIONAL SALES AND SUPPORT OFFICES For more information about Agilent Technologies test and measurement products, applications, services, and for a current sales office listing, visit our web site: http://www.agilent.com/find/tmdir. You can also contact one of the following centers and ask for a test and measurement sales representative. 11/29/99 U ...

Manufacturer Agilent Technologies Category Power Supply

Documents that we receive from a manufacturer of a Agilent Technologies 16048A can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 16048A manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 16048A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 16048A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 16048A, service manual, brief instructions and user manuals Agilent Technologies 16048A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 16048A.

A complete manual for the device Agilent Technologies 16048A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 16048A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 16048A.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 16048A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 16048A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 16048A, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 16048A - which should help us in our first steps of using Agilent Technologies 16048A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 16048A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 16048A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 16048A?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 16048A, ask a question using the form below. If a user had a similar problem with Agilent Technologies 16048A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)