  • Oregon Scientific BAR182HG - page 1

    1 EN DIGIT AL WEA THER FORECASTER WITH REMOTE THERMO-HYGRO SENSOR AND ALARM CLOCK MODEL NO.: BAA182HG USER’S MANUAL INTRODUCTION Congratulations on your purchase of the W eather forecaster with cable free sensor and clock (BAR182HG). This unit has a large four-line liquid crystal display (LCD) for displaying weather forecast information, in/outdo ...

  • Oregon Scientific BAR182HG - page 2

    2 EN A . FRONT DISPLA Y A four line easy-to-read LCD A1. WEA THER FORECAST WINDOW Graphically illustrates a weather forecast B. [ ] BA TTERY-LOW INDICA TOR Activates when the remote-sensor or main unit battery power is low C. [ 1 ] / [ 2 ] ALARM-ON ICONS Appears when the alarm is activated D . [((1))] / [((2))] ALARM ICONS Appears when the respecti ...

  • Oregon Scientific BAR182HG - page 3

    3 EN FEA TURES: REMOTE THERMO-HYGRO SENSOR A. TWO-LINE LCD Displays the current temperature and humidity monitored by the remote unit B . LED INDICA TOR Flashes when the remote sensor transmits a reading C. °C/°F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) D . CHANNEL SLIDE SWITCH Select the remote sensor Channel 1, Channel ...

  • Oregon Scientific BAR182HG - page 4

    4 EN easier synchronization between the transmission and reception of signals. 4. Position the remote unit and main unit within effective transmission range, which, in usual circumstances, is up to 30 meters. Note that the effective range is vastly affected by the building materials and where the main and remote units are positioned. Try various se ...

  • Oregon Scientific BAR182HG - page 5

    5 EN LOW BA TTERY W ARNING When it is time to replace batteries, the respective low-battery indicator will show up when the respective channel is selected. HOW TO USE THE T ABLE ST AND OR W ALL MOUNTING The main unit has a removable table stand, which when connected, can support the unit on a flat surface. Or you can remove the stand and mount the ...

  • Oregon Scientific BAR182HG - page 6

    6 EN T o force a signal search: Press and hold [CHANNEL] & [MEM] for 2-seconds to enforce a 3-minute search. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find discrepancies between the reading shown on the main unit and that on the respective remote unit. HOW TO CHECK ...

  • Oregon Scientific BAR182HG - page 7

    7 EN HOW TO READ THE KINETIC W A VE DISPLA Y The kinetic wave display shows the signal receiving status of the main unit. There are three possible forms: The unit is in searching mode. Transmission data are securely registered. No signal received in search mode. REMOTE SENSOR SCANNING The unit can be set to automatically scan and display readings f ...

  • Oregon Scientific BAR182HG - page 8

    8 EN TEMPERA TURE, HUMIDITY & PRESSURE TREND INDICA T ORS The temperature-trend, humidity-trend and pressure trend indicators show the trends of collected readings. Arrows indicate a rising, steady or falling trend. Note: If the readings goes above or below the measuring range of the main unit or the remote unit ( stated in specification), the ...

  • Oregon Scientific BAR182HG - page 9

    9 EN The high-low displays are as follows: T o set a high or low temperature or humidity alarm: 1. Press [HI/LO] , channel-1 will be displayed. 2. Press [ ] to set the temperature or humidity limit. Each press will increase increments by one degree or percentage. Press and hold the button for a rapid-scrolling sequence by increments of five. Note: ...

  • Oregon Scientific BAR182HG - page 10

    10 EN Cloudy Sunny Forecast Rainy Slightly Cloudy Indicator displays on the unit NOTE: 1. The accuracy of a general pressure-based weather forecast is about 70% to 75%. 2. The weather forecasts from this unit are predictions that cover the next 12 to 24 hours. It may not necessarily reflect the current situation. 3. The “Sunny” icon, as applies ...

  • Oregon Scientific BAR182HG - page 11

    11 EN For the 2nd time zone, which is indicated by the ZONE icon, enter the hour offset using the [ ] and [ ] (CLOCK) buttons and the BAA182HG will calculate the second zone-time accordingly . If there is an item you do not wish to change, simply press [ MODE] to bypass the item. When you are done, press [ MODE ] to exit. The display will return to ...

  • Oregon Scientific BAR182HG - page 12

    12 EN MAINTENANCE When handled properly , this unit is engineered to give you years of satisfactory service. Here are a few product care instructions: 1. Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth. 2. Do not clean the unit with abrasive or corrosive materials. Abrasive c ...

  • Oregon Scientific BAR182HG - page 13

    13 EN NOTE ON COMPLIANCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operations. Warning: Changes or modifications to this unit n ...

  • Oregon Scientific BAR182HG - page 14

    14 EN W ARRANTY This product is warranted to be free of manufacturing defects for a period of 1 year from date of retail purchase. Defective product should be directed to the place of retail purchase for exchange. Should this not be possible, contact our customer care department for assistance and a return material authorization. No returns may be ...

Manufacturer Oregon Scientific Category Radar Detector

Documents that we receive from a manufacturer of a Oregon Scientific BAR182HG can be divided into several groups. They are, among others:
- Oregon Scientific technical drawings
- BAR182HG manuals
- Oregon Scientific product data sheets
- information booklets
- or energy labels Oregon Scientific BAR182HG
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oregon Scientific BAR182HG.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oregon Scientific BAR182HG, service manual, brief instructions and user manuals Oregon Scientific BAR182HG. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oregon Scientific BAR182HG.

A complete manual for the device Oregon Scientific BAR182HG, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oregon Scientific BAR182HG by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oregon Scientific BAR182HG.

A complete Oregon Scientific manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oregon Scientific BAR182HG - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oregon Scientific BAR182HG, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oregon Scientific BAR182HG, that we can find in the current document
3. Tips how to use the basic functions of the device Oregon Scientific BAR182HG - which should help us in our first steps of using Oregon Scientific BAR182HG
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oregon Scientific BAR182HG
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oregon Scientific BAR182HG in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oregon Scientific BAR182HG?

Use the form below

If you did not solve your problem by using a manual Oregon Scientific BAR182HG, ask a question using the form below. If a user had a similar problem with Oregon Scientific BAR182HG it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)