C2473M-C (8/06) 3 Contents Important Safe ty Instruct ions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
-
Pelco IPS-RDPE-2 - page 4
4 C2473M-C (8/06) Important Safety Instructions Prior to installation an d use of this product, the following warnings shou ld be obser ved. 1. Installation and servicin g should be done only by qu alified service personnel and conform to all local codes. 2. Use only re placement parts r ecommended by Pelco . 3. Use stainless steel ha rdware to fas ...
-
Pelco IPS-RDPE-2 - page 5
C2473M-C (8/06) 5 Description Pelco’ s IPS-RDPE-2 dat a port box is an on-sit e service too l designed f or Spectra III ™ SE, Spectra III, Esprit ® , and ExSit e ™ Series positioning systems. The d ata port b ox gives on -site acc ess for setu p and testi ng of the p ositioning system. The IPS-RDPE-2 can be used to locally view vide o and co ...
-
Pelco IPS-RDPE-2 - page 6
6 C2473M-C (8/06) Mounting Instructions W ALL MOUNTING 1. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.9 1 cm) conduit fittings (not supp lied). Close the lid of the IPS- RDPE-2 box. 2. Determin e the mounting lo cation for the IPS-RDP E-2. 3. Use the IPS- RDPE-2 box as a template and ma rk the four fastener positions on the mounting ...
-
Pelco IPS-RDPE-2 - page 7
C2473M-C (8/06) 7 POLE MOUNTING 1. Install the P A402 mount adap ter . Refer t o the instruct ions supplie d with the ad apter . 2. Open the lid of the IPS-RDPE-2 box. Install two 3/4-inch (1.9 1 cm) conduit fittings (not supp lied). Close the lid of the IPS- RDPE-2 box. 3. Attach the IPS-RDPE -2 to the P A402, and secure with the hardware supplied ...
-
Pelco IPS-RDPE-2 - page 8
8 C2473M-C (8/06) Cable/Wire Requirements and Connector Locations Refer to Figure 3 for a layou t of the data port box connector s. It is important to connec t all four communication wires from the IPS-RDPE-2 to the Spectra III dome system or ExSite system. It will not be possible to perform softwa re and lang uage file up loads if th e transmit an ...
-
Pelco IPS-RDPE-2 - page 9
C2473M-C (8/06) 9 Wiring Diagrams The IPS-RDPE-2 is design ed to work in both coaxia l cable and un shi elded twisted pair (UTP) vide o transmis sion s ystems. Installa tion configurat ions include the fo llowing: • Coaxitron Controller with Co ax Video • Coaxitron Controller wit h UTP Vi deo (Passive Receiver Only) • RS-422 (D or P) Protocol ...
-
Pelco IPS-RDPE-2 - page 10
10 C2473M-C (8/06) Figure 5. Coaxitron Controller with UTP Video – Passive Receiver Only NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG. • Refer to the manual su pplied with t he position ing system for w ...
-
Pelco IPS-RDPE-2 - page 11
C2473M-C (8/06) 11 Figure 6. RS-422 (D or P Protocol) Controller with Coax Video – Point-to-Point Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG. • Refer to the manual su ...
-
Pelco IPS-RDPE-2 - page 12
12 C2473M-C (8/06) Figure 7. RS-422 (D or P Protocol) Controller with Coax Video – Home Run Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG. • Refer to the manual su pplied ...
-
Pelco IPS-RDPE-2 - page 13
C2473M-C (8/06) 13 Figure 8. RS-422 (D or P Protocol) Controller with Coax Video – Daisy-Chain Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximum wire gaug e allowed for two-wire communication is 16 A WG. • Refer to the manual su ppl ...
-
Pelco IPS-RDPE-2 - page 14
14 C2473M-C (8/06) Figure 9. RS-422 (D or P Protocol) Controller with UTP Video – Point-to-Point Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG. • Refer to the manual supplied with the back ...
-
Pelco IPS-RDPE-2 - page 15
C2473M-C (8/06) 15 Figure 10. RS-422 (D or P Protocol) Controller wit h UTP Video – Home Run Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG. • Refer to the manual su pplied with t he positio ...
-
Pelco IPS-RDPE-2 - page 16
16 C2473M-C (8/06) Figure 11. RS-422 (D or P Protocol) Controller wit h UTP Vid eo – Daisy-Chain Configuration NOTES: • Input po wer for the IPS-RDPE-2 is 24 VAC only . The max imum wire gau ge allowed fo r power inpu t and outp ut is 12 AWG. • The maximu m wire gauge allowed for U TP is 16 AWG. • Refer to the manual su pplied with t he pos ...
-
Pelco IPS-RDPE-2 - page 17
C2473M-C (8/06) 17 Operation T o view video, control pan /tilt/zoom, or upload rev ised operat ing software a nd language files to a p ositioning s ystem, do the f ollowing: 1. Open th e door of t he IPS-RDPE-2. Opening the door will auto matically disconne ct the controller at the head-e nd and trigger an audible alert at the IPS-RD PE-2 site . NO ...
-
Pelco IPS-RDPE-2 - page 18
18 C2473M-C (8/06) Specifications ELECTRICAL Input V oltage 24 V AC Power Consumpt ion 1 V A Does not inc lude power required fo r position ing system MECHANICAL Construction Aluminum Finish Gray polyester powder coat Cable Entry T wo hole plugs will accommodate 3/4-inch (1.91 cm) conduit fittin gs (not supplied) Mount Meth od Four 0.375- inch (0.9 ...
-
Pelco IPS-RDPE-2 - page 19
The materials used in the manufacture of this docume nt and it s components are compliant to the requirements of Directive 2002/9 5/EC. This equipment contains elec trical or electronic components that must be recy cled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrica l and electronic equi ...
-
Pelco IPS-RDPE-2 - page 20
W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 United States | Canada | United Kingdom | The Netherlands | Singapore | Spain | Scandinavia | France | Middle East ...
Do you have a question concerning Pelco IPS-RDPE-2?
Use the form below
If you did not solve your problem by using a manual Pelco IPS-RDPE-2, ask a question using the form below. If a user had a similar problem with Pelco IPS-RDPE-2 it is likely that he will want to share the way to solve it.