Manual Oregon Scientific WR602

20 pages 0.3 mb
Download

Go to site of 20

Summary
  • Oregon Scientific WR602 - page 1

    EN 1 Portable Public Alert Radio Model: WR602 USER MANUAL CONTENTS Introduction ............................................................ 2 About the National Weather Radio System ......... 2 Consumer Electronics Association (CEA) .......... 2 Product Overview .................................................... 3 Front View .................... ...

  • Oregon Scientific WR602 - page 2

    EN 2 INTRODUCTION Thank you for selecting the Oregon Scientific TM Portable Public Alert Radio (WR602). This device operates on the same radio frequencies used by the National Weather Radio (NWR) and can send you NOAA alert messages to warn you about weather and other environmental dangers. This lightweight, splashproof radio is constructed of dura ...

  • Oregon Scientific WR602 - page 3

    EN 3 1. LCD 2. TR / HM: Press and hold to select travel or home mode 3. EXIT : Press to exit any display or setting (clock is default setting) 4. / : Increase / decrease settings; increase / decrease volume; enable / disable alarm 1 or 2; scroll up or down to select county code 5. 9V AC / DC adapter 6. LED indicator: Red / green LED indicates radio ...

  • Oregon Scientific WR602 - page 4

    EN 4 BACK VIEW 1. Antenna 2. Neck strap: Insertion point for neck strap 3. : Press to activate 8-minute snooze and / or backlight for 5 seconds 4. : Press and hold to turn power ON / OFF; press to switch between NOAA ON / Standby / Mute / OFF modes 5. External speaker jack 6. RESET hole 7. Battery compartment RECHARGING CRADLE AND AC / DC ADAPTER B ...

  • Oregon Scientific WR602 - page 5

    EN 5 NECK STRAP GETTING ST ARTED BA TTERIES Rechargeable batteries are included and must be used if you want to use the recharging cradle. However , the unit can use 3 x UM-3 (AA) 1.5V batteries. Insert the rechargeable battery by putting the piece at the end of the wire into the indentation at the bottom right of the battery compartment: Insert ba ...

  • Oregon Scientific WR602 - page 6

    EN 6 T o switch between the clock mode displays, press MENU . T o switch between the radio status mode displays, press . NOTE Leaving the radio in NOAA ON mode will consume substantially more power . T o save power , set the unit to NOAA Standby when you are not listening to radio broadcasts. T o change clock, alarm, channel and location settings: ...

  • Oregon Scientific WR602 - page 7

    EN 7 NOAA ALERT MESSAGES MESSAGE CODES USED BY THE NWR When the NWR airs urgent warnings, a digital code known as Specific Area Message Encoding (SAME) is included as part of the message. This coding system contains specific information including the localized geographical area affected and the expiration time of the message. The WR108 retrieves an ...

  • Oregon Scientific WR602 - page 8

    EN 8 NOTE Many counties have been subdivided into as many as 9 smaller subsections. The numbers 1-9 in the far left column of the SAME code identifies specific subsections of a county . If a county has not been subdivided, the first digit of the SAME code will be 0. CHANNELS ABOUT RADIO CHANNELS The NWR radio channels work in the same way as a regu ...

  • Oregon Scientific WR602 - page 9

    EN 9 T o set the location: 1. Navigate to “Set Location” setting mode as shown in the Changing Settings section. 2. Select where you want to store the location e.g. C1. 3 . Select the 6-digit number e.g. “000000”. (“----“ means the location is disabled.) 4. Select “Name” or “FIPS”. • If you select “Name” you can select fir ...

  • Oregon Scientific WR602 - page 10

    EN 10 1 2 3 4 5 6 7 8 9 county will be received. T o receive all of the alerts for a given county , insert 0 into the county sub-section. A county can be subdi vi ded as follows: 1 Northwest 2 North Central 3 Northeast 4 West Central 5 Central 6 East Central 7 Southwest 8 South Central 9 Southeast RECEPTION TEST The fact that you can get clear voic ...

  • Oregon Scientific WR602 - page 11

    EN 11 INTERPRETING NOAA ALERT MESSAGES This product is equipped to receive all required NOAA and Emergency Alert System (EAS) events. When an EAS event is sent by the NWS, any 1 of the following NOAA alert messages will be displayed on your radio: “WARNING”, “W A TCH”, or “ADVISORY”. The unit can store up to 8 NOAA alert messages. Addit ...

  • Oregon Scientific WR602 - page 12

    EN 12 NA TURE OF ACTIV A TION SP ANISH FRENCH MESSAGE Administrative Message Mensaje administrativo Message administratif ADVISORY Avalanche W atch Vigilancia de avalancha V eille d'avalanche WA TCH Avalanche W arning Aviso de avalancha Alerte d'avalanche WARNING Biological Hazard W arning Aviso de riesgo biológico Alerte risque biologiq ...

  • Oregon Scientific WR602 - page 13

    EN 13 Flash Flood Statement Advertencia de inundaciones relámpago B u l l e t i n spécial de crue subite ADVISOR Y Flash Flood W arning Aviso de inundaciones relámpago Alerte de crue subite W ARNING Flood W atch Vigilancia de inundación V eille d'inondation W A TCH Flood Statement Advertencia de inundación B u l l e t i n spécial de risq ...

  • Oregon Scientific WR602 - page 14

    EN 14 Radiological Hazard W arning Aviso de peligro radiológico Alerte de risque radiologique WARNING Required Monthly T est Prueba mensual obligatoria T est mensuel obligatoire ADVISORY Required Weekly T est Prueba semanal obligatoria T est hebdomadaire obligatoire ADVISORY Special Marine W arning Aviso especial de la Marina Alerte martime spéci ...

  • Oregon Scientific WR602 - page 15

    EN 15 NOTE The 4 “Unrecognized” messages above will appear when a new NOAA alert message is created and broadcasted. The unit will not be able to recognize the message as it is not in the software database. CLOCK & CALENDAR T o set the time and date, navigate to “Set Clock” setting mode as shown in the Changing Settings section. The ord ...

  • Oregon Scientific WR602 - page 16

    EN 16 alcohol-free, mild detergent. Avoid dropping the product or placing it in a high-traffic location. • Do not subject the main unit to extreme force, shock, or fluctuations in temperature or humidity . • Do not tamper with the internal components. • Do not mix new and old batteries or batteries of different types. • Remove the batteries ...

  • Oregon Scientific WR602 - page 17

    EN 17 Daily alarm 2 x 1-minute duration alarms Snooze 8-minute snooze GENERAL SPECIFICA TIONS Battery type Rechargeable batteries or 3 x UM-3 or AA size 1.5V (optional only) AC / DC adapter 9V Unit dimensions 5.4 (L) x 3 (W) x 1.4 (D) inches (137 x 74 x 35 mm) Unit weight 4.5 oz (131 g) without batteries Operating temp 23 ° F to 122 ° F (-5 ° C ...

  • Oregon Scientific WR602 - page 18

    EN 18 and receiver . • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio / TV technician for help. DECLARA TION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number(l ...

  • Oregon Scientific WR602 - page 19

    EN 19 Portable Public Alert Radio Model: WR 602 USER MANUAL WR602_EN 27/6/07, 12:58 PM 19 ...

  • Oregon Scientific WR602 - page 20

    EN 20 © 200 7 Oregon Scientific. All rights reserved. 086-003868-019 WR602_EN 27/6/07, 12:58 PM 20 ...

Manufacturer Oregon Scientific Category Portable Radio

Documents that we receive from a manufacturer of a Oregon Scientific WR602 can be divided into several groups. They are, among others:
- Oregon Scientific technical drawings
- WR602 manuals
- Oregon Scientific product data sheets
- information booklets
- or energy labels Oregon Scientific WR602
All of them are important, but the most important information from the point of view of use of the device are in the user manual Oregon Scientific WR602.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Oregon Scientific WR602, service manual, brief instructions and user manuals Oregon Scientific WR602. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Oregon Scientific WR602.

A complete manual for the device Oregon Scientific WR602, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Oregon Scientific WR602 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Oregon Scientific WR602.

A complete Oregon Scientific manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Oregon Scientific WR602 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Oregon Scientific WR602, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Oregon Scientific WR602, that we can find in the current document
3. Tips how to use the basic functions of the device Oregon Scientific WR602 - which should help us in our first steps of using Oregon Scientific WR602
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Oregon Scientific WR602
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Oregon Scientific WR602 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Oregon Scientific WR602?

Use the form below

If you did not solve your problem by using a manual Oregon Scientific WR602, ask a question using the form below. If a user had a similar problem with Oregon Scientific WR602 it is likely that he will want to share the way to solve it.

Copy the text from the picture