Manual Bryant 664B

22 pages 1.13 mb
Download

Go to site of 22

Summary
  • Bryant 664B - page 1

    1 664B 13 SEER S INGLE - - P ACKAGED H EA T PUMP SYSTEM WITH R - - 22 REF RIGERANT SINGLE AND THREE PHAS E 2 - - 5 NOMINAL T ONS (SIZES 024 - - 060) Installation Instructions NOTE : Read the en tire in structio n m anu al b efore starting th e installatio n . T ABLE OF CONTENTS P AGE SAFETY CONSIDERA TI ONS 2 ......................... INTRODUCTI ON ...

  • Bryant 664B - page 2

    2 SAF ETY CONSIDERA TIONS Installatio n and serv icing o f th is equ ipm en t can b e hazar dous due to m ec ha nic a l a nd e le c tr i ca l com ponent s . Onl y t ra i ned a nd qual i fi e d pers onne l shoul d ins ta l l, r e pai r , or se rvi c e thi s equi pme nt. Untr a ine d per sonne l ca n per for m bas i c mai nt ena nc e func tions suc h ...

  • Bryant 664B - page 3

    3 Wh en desig n ing an d in stalling d u ctwo rk , consid er the follo win g: UNIT DAMAGE HAZARD Failu re to follow th is cautio n may resu lt in damag e to un it com ponent s . Whe n conne cti ng duc twor k t o uni t s, do not dri l l dee pe r than 3 /4 in . (19 mm ) in sh ad ed area sh o wn in Fig . 2 o r co il may be d amag ed . CAUTION ! 19.17 ...

  • Bryant 664B - page 4

    4 A08414 Fig. 5 - - Unit Bas e Dim ens i ons, 664B024- - 060 664B ...

  • Bryant 664B - page 5

    5 TOP CO VER INDOOR THERMOST AT DISCONNECT PER NEC (UNIT AND ELECTRIC HEA TER) FROM POWER SOURCE RETURN AIR POWER AND LOW -VOL T AGE ENTRY COMPOSITE RUST -PROOF BASEP AN CONDENSA TE DRAIN CONNECTION Pow er W ir i n g Control Wiring Condenser Airflow Evaporator Airflow A08207 Fig. 6 - - T ypical I ns tal lat i on T able 1 – Phys ic a l D ata UNIT ...

  • Bryant 664B - page 6

    6 T a bl e 2 – Min imu m Airflo w fo r S afe E lectric Hea ter O pera tio n Unit Si ze Minimum Airflow ( CFM) 5kW 7.5kW 10kW 15kW 20kW 024 500 650 750 -- -- 030 600 800 1050 -- -- 036 600 800 1050 1 150 1200 042 600 800 1050 1 150 1200 048 600 800 1050 1 150 1200 060 600 800 1050 1 150 1200 Step 7 — In sta ll E l ectrical Con n ection s ELECTRI ...

  • Bryant 664B - page 7

    7 HEATER LOW VOLTAGE PLUG A05388 Fig. 8 - - Contr ol Box Wi ri ng 3-PHASE CONNECTIONS T O DISCONNECT PER NEC SINGLE-PHASE CONNECTIONS T O DISCONNECT PER NEC GROUND LEAD UNIT GROUND BLK YEL BLU L L L C00012 Fig . 9 - - L ine P o wer C on n ection s Therm ostat Unit Control G Y W2 W3 R RED GRN YEL O ORN C BRN WH T VIO and subbase Power A05207 Fig. 10 ...

  • Bryant 664B - page 8

    8 c. In sp ect all field - - and factory - - w iring con nectio n s. Be sure th at co n nectio n s are com p leted an d tight. d. Ensure wire s do not t ouch r e fr i ger a nt t ubi ng or s ha rp sheet m etal ed ges. e. In sp ect coil fins. If damag ed d u ring sh ip p ing an d handl i ng, c a re f ull y s tr ai ght en f i ns w it h a f i n com b. ...

  • Bryant 664B - page 9

    9 T a ble 3 – Re quir ed Subc ooli ng A08406 Ste p 4 — Indoor Air f low and Air flo w Adj ust- ments NOTE : For cool ing opera t ion, t he rec omme nded air f low is 350 to 45 0 cfm fo r each 12,0 0 0 Btu h o f rated coolin g cap acity. T able 4 s hows dr y c oil a ir del i ver y f or hor i zont a l di sc har ge unit s. T able s 6- - 8 show pre ...

  • Bryant 664B - page 10

    10 Step 5 — Unit Contr ols All c ompr e ss or s have t he f oll owi ng int e rna l- -prote c ti on contr ol s. HIGH- - PRESSURE RELIEF V AL VE Th is v alv e o p ens when th e pressu re dif feren tial betw een the lo w and h ig h side beco m es e x cessive. LOSS OF CHARGE SWITCH Loca t ed on the outdoor l iqui d l ine i s a low- - pres s ure swi t ...

  • Bryant 664B - page 11

    11 A08209 Fig. 13 - - T ypical Si ngle- - Phase Uni t Ele c tr i cal Di agr am (Si ze s 024- - 042) 664B ...

  • Bryant 664B - page 12

    12 A06405 Fig. 14 - - T ypical Si ngle- - Phase Uni t Ele c tr i cal Di agr am (Si ze s 048- - 060) 664B ...

  • Bryant 664B - page 13

    13 A06325 Fig. 15 - - T ypical Thr ee- -Phase Uni t Ele c tr i cal Di agr am (Si ze s 030- - 042) 664B ...

  • Bryant 664B - page 14

    14 A06326 Fig. 16 - - T ypical Thr ee- -Phase Uni t Ele c tr i cal Di agr am (Si ze s 048- - 060) 664B ...

  • Bryant 664B - page 15

    15 A05209 Fig . 1 7 - - S in gle - - P h ase A ccessory Electric H eater Wiring A06327 Fig . 1 8 - - T hree- - Ph a se Accesso ry Electric Hea ter Wiring 664B ...

  • Bryant 664B - page 16

    16 T a bl e 4 – Dry C o il Air Delivery * Ho rizo nta l Discha rg e (Ded uct 1 0 p er cent fo r 2 08 V olt O pera tio n) 230 VOLT HORIZONTAL DISCHARGE UNIT SIZE SPEED TA P AIR DELIVER Y EX TE RNAL S T A T IC P R ES S URE (IN. WC) 0.1 0. 2 0.3 0.4 0.5 0.6 0. 7 0.8 0.9 1.0 024 1 Watts — 99 100 118 130 142 — — — — CFM — 848 793 757 698 6 ...

  • Bryant 664B - page 17

    17 T a b l e5–C o o l i n gC h a r g i n gC h a r t SUCTION LIN E TEMPERA TUR E ( ° F) Sucti on Line P ressur e (PSI G) OD T emp . ( ° F) 52 54 56 59 61 64 67 70 73 76 79 82 85 89 92 45 51 55 60 64 69 — — — — — — — — — — 55 — — 53 57 62 66 70 — — — — — — — — 65 — — — — 53 57 62 66 71 75 — — ? ...

  • Bryant 664B - page 18

    18 Only qua lif ie d s er vi ce per s onne l shoul d per f orm ma int e nanc e and se r vic e pr oce dur es t ha t re qui re uni t top re mova l . Ref e r t o the foll owi ng top r em oval proc e dure s : 1. Remo v e screws o n unit to p cover su rface. (S av e all screws.) 2. Remove sc rews on unit t op cover f l ange . (Sa ve a ll s c re ws .) 3. ...

  • Bryant 664B - page 19

    19 Step 4 — Ou tdoor Coil, In door Coil, and Conde nsa te D rain Pan Ins pe ct the conde ns e r coi l , eva por at or coi l, a nd conde nsa t e dr ai n pan at least on ce each y ear . Th e coils are easily cleaned w hen d ry ; th erefor e, inspect an d clean the co ils eith er b efo re or after each co o ling season . Rem ov e all obst r uct i on ...

  • Bryant 664B - page 20

    20 STRAINER ACCUMULA TOR COMPRESSOR STRAINER LCS OUTDOOR COIL INDOOR COIL A B D C Check V alves A Open B Closed C Open D Closed LEGEND LCS Loss of Charge Switch Acutrol Metering Device Check V alve (Arrow indicates direction of flow) HEA TING CYCLE 1. Hot gas from compressor flows through the 4-way valve and is directed to the cooling liquid line c ...

  • Bryant 664B - page 21

    21 T a ble 9 – T roubl e shoot i ng Chart SYMPTOM CAUSE REMEDY Comp ressor and o ut door fan will no t start Power f ailur e Call power c ompany Fuse blown or c ircuit br eaker tr ipped Replace fus e or res et cir cuit break er Defectiv e contactor, transformer, control relay , or high- - pr ess ure, loss - - of - -c harge or low - - pres sur e s ...

  • Bryant 664B - page 22

    22 ST AR T - - UP CHECKLIST (REMOVE AND ST ORE IN JOB FIL E) I. PRELI MINAR Y INFORMA TION Mo del No ............................................................................................................................................................ Serial N o ................................................................................. ...

Manufacturer Bryant Category Heat Pump

Documents that we receive from a manufacturer of a Bryant 664B can be divided into several groups. They are, among others:
- Bryant technical drawings
- 664B manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 664B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 664B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 664B, service manual, brief instructions and user manuals Bryant 664B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 664B.

Similar manuals

A complete manual for the device Bryant 664B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 664B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 664B.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 664B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 664B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 664B, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 664B - which should help us in our first steps of using Bryant 664B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 664B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 664B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant 664B?

Use the form below

If you did not solve your problem by using a manual Bryant 664B, ask a question using the form below. If a user had a similar problem with Bryant 664B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)