    Milwa uk ee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter ...

  • Milwaukee MW600 - page 2

    PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the meter. Install the battery into the battery clip connector while observing polarity. D.O. probes are shipped dry. Assemble the probe and prepare it for use, connect it to the meter and proceed as follows. 1. Remove the red and blac ...

  • Milwaukee MW600 - page 3

    PROBE POLARIZATION: • A dissolved oxygen probe must be polarized to function properly. • To polarize the probe, the fully assambled probe must be connected to the meter and the meter must be on. • During polarization (and during measurement), approximately 800 mV is applied to the cathode and anode inside the membrane and a chemical reaction ...

  • Milwaukee MW600 - page 4

    Zero Calibration: • Dip the probe into MA9070 zero oxygen solution and stir gently for 2-3 minutes. • Wait for the probe to reach it’s lowest stable reading. • Adjust the zero D.O. calibration trimmer (located on the front panel) until the display reads "0.0". Slope Calibration: It is suggested to perform the slope calibration in ...

  • Milwaukee MW600 - page 5

    TAKING MEASUREMENTS: Verify the probe is polarized and the probe and meter have been calibrated. Remove the protective cap from probe. Immerse the tip of the probe in the sample to be tested. For accurate dissolved oxygen measurements a minimum water movement of 0.3 m/sec is required. This is to ensure that the oxygen-depleted membrane surface is c ...

  • Milwaukee MW600 - page 6

    5 °C 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 0 m 14.6 13.8 13.1 12.4 11.8 11.3 10.8 10.3 9.9 9.5 9.1 8.7 8.4 8.1 7.8 7.5 7.3 7.1 6.8 6.6 6.4 300 m 14.1 13.3 12.7 12.0 11.4 10.9 10.4 9.9 9.7 9.2 8.8 8.4 8.1 7.8 7.5 7.2 7.1 6.9 6.6 6.4 6.2 600 m 13.6 12.9 12.2 11.6 11.0 10.5 10.1 9.6 9.2 8.7 8.5 8.1 7.8 7.5 7.3 7.0 6.8 6.6 6.3 6.2 ...

  • Milwaukee MW600 - page 7

    6 SALINITY COMPENSATION: The t able below illustrates the change in the solubility of oxygen in air saturated water as a result of chloride concentration or salinity . The t able can also be used to correct the displayed measurement. If you are making measurement s in salt water and know the chloride concentration (or salinity), you can multiply yo ...

  • Milwaukee MW600 - page 8

    7 PROBE & MEMBRANE MAINTENANCE: The D.O. probe body is made of reinforced plastic for maximum durability. A thermistor temperature sensor provides temperature measurements of the tested sample. It is always recommended to keep the protective cap on the probe when not in use, to protect the membrane against damage and dirt. To replace the membra ...

  • Milwaukee MW600 - page 9

    The Platinum cathode should always be bright and untarnished. If it is tarnished or stained, due to contact with certain gases or a damaged membrane cap, the cathode should be cleaned. You can use a clean lint-free cardboard or cloth. Rub the cathode very gently side to side 4-5 times. This will be enough to polish and remove any stains without dam ...

  • Milwaukee MW600 - page 10

    BATTERY REPLACEMENT: When the battery becomes weak the meter will display the low battery indicator " ". When this appears, only a few hours of battery life remain. A low battery will result in unreliable measurements. Prompt battery replacement is required. Battery replacement must take place in a non-hazardous area using an alkaline 9V ...

  • Milwaukee MW600 - page 11

    SPECIFICATIONS: MW600 RANGE 0.0 to 19.9 mg/L RESOLUTION 0.1 mg/L ACCURACY (@25°C) ±1.5% Full Scale TEMPERATURE Automatic from 0 to 30°C COMPENSATION CALIBRATION Manual on 2 points (zero and slope) LCD 3½ digits with symbols PROBE MA840 (included) ENVIRONMENT 0 to 50°C, 95% RH max. BATTERY TYPE 9V alkaline (included) BATTERY LIFE approximately ...

  • Milwaukee MW600 - page 12

    ISTMW600 01/10 Milwa uk ee Authorized Dealer: ...

Производитель Milwaukee Категория Marine Instruments

Документы, которые мы получаем от производителя устройства Milwaukee MW600 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Milwaukee
- инструкции обслуживания MW600
- паспорта изделия Milwaukee
- информационные брошюры
- энергетические этикетки Milwaukee MW600
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Milwaukee MW600.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Milwaukee MW600, инструкции обслуживания, короткие инструкции или инструкции пользователя Milwaukee MW600. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Milwaukee MW600.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Milwaukee MW600, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Milwaukee MW600 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Milwaukee MW600.

Полная инструкция обслуживания Milwaukee, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Milwaukee MW600 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Milwaukee MW600, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Milwaukee MW600, которое найдем в данном документе
3. Советы по использованию основных функций устройства Milwaukee MW600 - которые должны облегчить нам первые шаги во время использования Milwaukee MW600
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Milwaukee MW600
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Milwaukee MW600 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Milwaukee MW600?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Milwaukee MW600, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Milwaukee MW600 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)