Инструкция обслуживания Nortel 4500 FIPS

14 страниц 0.29 mb
Скачать

Перейти на страницу of 14

Summary
  • Nortel 4500 FIPS - page 1

    © Copyright 2000 Nortel Networks. This document may be freely reproduced and distributed whole and intact including this Copyright Notice. Contivity™ Extranet Switch 4500 FIPS 140-1 Non-Proprietary Cryptographic Module Security Policy Level 2 Validation February 2000 ...

  • Nortel 4500 FIPS - page 2

    © Copyright 2000 Nortel Networks. 2 Table of Contents 1 Introduction .................................................................................................................. 3 1.1 Purpose ................................................................................................................... 3 1.2 References .................. ...

  • Nortel 4500 FIPS - page 3

    © Copyright 2000 Nortel Networks. 3 1 Introduction 1.1 Purpose This is a non-proprietary Cryptographic Module Security Policy for the Contivity™ Extranet Switch 4500. This security policy describes how the Contivity™ Extranet Switch 4500 meets the security requirements of FIPS 140-1, and how to operate the Contivity™ Extranet Switch 4500 in ...

  • Nortel 4500 FIPS - page 4

    © Copyright 2000 Nortel Networks. 4 This document provides an overview of the Contivity™ Switch and explains the secure configuration and operation of the module. This introduction section is followed by Section 2, which details the general features and functionality of the Contivity™ Switch. Section 3 specifically addresses the required confi ...

  • Nortel 4500 FIPS - page 5

    © Copyright 2000 Nortel Networks. 5 2 The Contivity Extranet 4500 Switch The Nortel Networks Contivity Extranet Switch 4500 provides a scalable, secure, manageable remote access server that meets FIPS 140-1 level 2 requirements. This section will describe the general features and functionality provided by the Contivity Extranet Switch. Section 3 w ...

  • Nortel 4500 FIPS - page 6

    © Copyright 2000 Nortel Networks. 6 . Figure 2 – Physical Interfaces The physical interfaces include the dual power plugs for the redundant power supplies, the power and reset buttons, the serial port, the LAN Port RJ-45 connector, and up to six slots containing additional network connectors. The power and reset buttons light up to indicate powe ...

  • Nortel 4500 FIPS - page 7

    © Copyright 2000 Nortel Networks. 7 Figure 4 – 10/100BASE-TX LAN LEDs These physical interfaces are separated into the logical interfaces from FIPS as described in the following table: Switch physical interface FIPS 140-1 Logical Interface 10/100BASE-TX LAN Port, LAN Port, Serial Port Data Input Interface 10/100BASE-TX LAN Port, LAN Port, Serial ...

  • Nortel 4500 FIPS - page 8

    © Copyright 2000 Nortel Networks. 8 front bezel allows access to the dual power supplies, hard drives, and floppy drive. Removing the top cover or the I/O panel allows access to the motherboard, memory, and expansion slots. Figure 5 – The Steel Cover of the Extranet Switch 4500 Once the Extranet Switch 4500 has been configured in its FIPS 140-1 ...

  • Nortel 4500 FIPS - page 9

    © Copyright 2000 Nortel Networks. 9 (2) Top Cover Labels (2) Front Bezel Labels Figure 6 – Tamper-Evident Labels Applied to Switch Front Bezel and Top Cover (2) AC Filter Input Labels (1) Air Hole Label (1) I/O Panel Label (1) Keyboard Connector Label Figure 7 – Tamper Evident Labels Applied to Rear Panel The tamper-evident seals are produced ...

  • Nortel 4500 FIPS - page 10

    © Copyright 2000 Nortel Networks. 10 Attempting to remove a label breaks it or continually tears off small fragments as depicted in Figure 9 . Other signs of tamper-evidence include a strong smell of organic solvents, warped or bent cover metal, and scratches in the paint on the module. FIPS 140-1 Level 2 Tamper Evident Label Serial Number: 567342 ...

  • Nortel 4500 FIPS - page 11

    © Copyright 2000 Nortel Networks. 11 • IPSec Protocol Tunnels • PPTP Protocol Tunnels • L2TP Protocol Tunnels • L2F Protocol Tunnels • Change Password 2.4.1 Crypto Officer Services There is a factory default login ID and password, which allows access to the Crypto Officer role. This initial account is the primary administrator's acc ...

  • Nortel 4500 FIPS - page 12

    © Copyright 2000 Nortel Networks. 12 • Status Functions : to view the switch configuration, routing tables, active sessions, use Gets to view SNMP { XE "SNMP" } MIB II { XE "SNMP:MIB II" } statistics, usage graphs, health, temperature, memory status, voltage, packet statistics, and review accounting logs. • Manage the Switc ...

  • Nortel 4500 FIPS - page 13

    © Copyright 2000 Nortel Networks. 13 2.5 Key Management The switch securely administers both cryptographic keys and other critical security parameters such as User passwords. Ephemeral sessions keys are created during the negotiation of secure tunnels on behalf of Users who have successfully authenticated themselves to the switch with their user I ...

  • Nortel 4500 FIPS - page 14

    © Copyright 2000 Nortel Networks. 14 Recommended • Change the default administrator password on the switch. • Disable all management protocols over private non- tunnelled interfaces Required • Select the “FIPS Enabled” button on the Service Available Management screens and restart the module. • Apply the tamper evident labels as descri ...

Производитель Nortel Категория Switch

Документы, которые мы получаем от производителя устройства Nortel 4500 FIPS мы можем разделить на несколько групп. Это в частности:
- технические чертежи Nortel
- инструкции обслуживания 4500 FIPS
- паспорта изделия Nortel
- информационные брошюры
- энергетические этикетки Nortel 4500 FIPS
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Nortel 4500 FIPS.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Nortel 4500 FIPS, инструкции обслуживания, короткие инструкции или инструкции пользователя Nortel 4500 FIPS. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Nortel 4500 FIPS.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Nortel 4500 FIPS, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Nortel 4500 FIPS пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Nortel 4500 FIPS.

Полная инструкция обслуживания Nortel, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Nortel 4500 FIPS - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Nortel 4500 FIPS, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Nortel 4500 FIPS, которое найдем в данном документе
3. Советы по использованию основных функций устройства Nortel 4500 FIPS - которые должны облегчить нам первые шаги во время использования Nortel 4500 FIPS
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Nortel 4500 FIPS
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Nortel 4500 FIPS в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Nortel 4500 FIPS?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Nortel 4500 FIPS, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Nortel 4500 FIPS со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)