Инструкция обслуживания Thermador PRG304

28 страниц 0.96 mb
Скачать

Перейти на страницу of 28

Summary
  • Thermador PRG304 - page 1

    Gas Supply: Natural Gas – 6 inch water column. (14.9mb) min., 8 inch (20mb) nominal Propane Gas – 11 inch water column. (27.4 mb), 14 inch (37mb) maximum Electrical Power Supply: PRG304, PRG36 and PRG48 Models – 120 VAC, 60 Hz., 1Ph., 20 Amp circuit. PRDS304 Model - 120/240 VAC, 50/60 HZ., 1Ph., 20 Amp circuit. PRDS36 Models – 120/240 VAC, ...

  • Thermador PRG304 - page 2

    IMPOR T ANT INST ALLA TION INFORMA TION WARNING: Improper installation, adjustment, alteration, service or main- tenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency, manufac- turer (dealer) or the gas supplier. Model PRDS364GD (Shown with High Shel ...

  • Thermador PRG304 - page 3

    ALL-GAS MODELS - PRG304 AND PRG36, DUAL FUEL MODELS PRDS304, PRDS36 AND PRDS48 CET MAN U EL CONTEN IT AVERTISSEMENTS EN FRANCAIS For Residential Use Only AVERTISSEMENT: Couper le courant avant d'installer. Avant de mettre EN MARCHE, soyez certain que tous les controles sont dans la position ARRÊTE. • Ne pas emmagasuner ou utiliser de l&apos ...

  • Thermador PRG304 - page 4

    A VERTISSEMENTS EN FRANCAIS A VER TISSEMENT Page 2 ...

  • Thermador PRG304 - page 5

    IMPOR T ANT INST ALLA TION INFORMA TION Notes: * For wall installations where adequate space is available, the installer or user may elect to use a hood that is wider than the range cooking surface. This may be particularly beneficial for those cases, such as a long duct run or heavy usage of the grill, in which improved capturing of the cooking ex ...

  • Thermador PRG304 - page 6

    STEP 2: CABINET PREP ARA TION For Electrical and Gas Supply Zone, see Figures 3a, 3b and 3c. Zone size and position differ according to the model. Cooking Surface required for each type of backguard. 7. Always keep appliance area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 8. Do not obstruct the flow ...

  • Thermador PRG304 - page 7

    STEP 2: CABINET PREP ARA TION CAUTION: Do not install the Model PRDS304 and PRDS48 ranges such that the front surface of the oven door is flush with the cabinet face. A flush installation could result in damage to the cabinets due to high heat. The face of the cabinet should line up with the oven front frame. The front frame location relative to th ...

  • Thermador PRG304 - page 8

    GAS AND ELECTRIC SUPPLY ZONES: STEP 2: CABINET PREP ARA TION 5/8" Flex Line to Appliance NOTE: A Manual Gas Shut-Off Valve (not shown) must be easily accessible through an adjacent cabinet without moving the range. NOTE: A Manual Gas Shut-Off Valve (not shown) must be easily accessible through an adjacent cabinet without moving the range. FIG. ...

  • Thermador PRG304 - page 9

    STEP 2: CABINET PREP ARA TION ELECTRICAL SUPPLY, DUAL FUEL RANGES Installation of Dual Fuel ranges must be planned so that the rough-in of the junction box for the receptacle or conduit connec- tion will allow maximum clear- ance to the rear of the unit. When the power supply cord (not supplied) or conduit is connected to the mating receptacle or j ...

  • Thermador PRG304 - page 10

    • The range has an approximate shipping weight as shown in Chart A. It is recommended that the door(s), grates, burner caps, front kick panel and oven racks be removed to facilitate handling. This will reduce the weight as shown in Chart A and allow the range to pass through 30" door- ways. See Chart B and Fig. 2a and 2b. Do not remove the g ...

  • Thermador PRG304 - page 11

    • Due to the weight, a dolly with soft wheels should be used to move this unit. The weight must be supported uniformly across the bottom (See Fig. 7). • After transporting the professional range by dolly close to its final location, the range can be tipped back and supported on the rear legs while the dolly is carefully removed. THE FLOOR UNDER ...

  • Thermador PRG304 - page 12

    STEP 4: INST ALLING ANTI-TIP DEVICE personal injury. CAUTION PROPERTY DAMAGE • Contact a qualified installer or contrac- tor to determine the proper method for drilling holes through the wall or floor material (such as ceramic tile, hard- wood, etc.) • Do not slide the range across an unpro- tected floor. • Failure to follow these instruction ...

  • Thermador PRG304 - page 13

    STEP 4: INST ALLING ANTI-TIP DEVICE P arts Required for Installation of Anti-T i p Device: PRG304 and PRG36 All Gas Ranges ( F igures 9 and 10) 15-10-948 (2 Each) 15-10-910 (1 Each) 15-10-911 (2 Each) 15-10-771 (1 Each) 15-10-916 (4 Each) 15-10-772 (1 Each) 15-10-909 (1 Each) Mounting Bracket FIG. 9 Mounting Kit for PRG304 and PRG36 All-Gas Ranges ...

  • Thermador PRG304 - page 14

    STEP 4: INST ALLING ANTI-TIP DEVICE PRG304 AND PRG36 All-Gas Ranges (Figures 9 , 10, 12a 12b and 13) STEP A : Determine the best location for the PRG Mounting Bracket. The bracket may be mounted to the wall or floor behind the range, offset from either the left or right side wall by 2-3/4" for model PRG304 or 4-5/8" for Model PRG36. - Loc ...

  • Thermador PRG304 - page 15

    STEP 4: INST ALLING ANTI-TIP DEVICE STEP A : Determine the best location for Anti- Tip Channel Mounting Bracket. The bracket may be mounted to the wall or floor behind the range, offset from side wall as indicated in the chart below and in Figures 14 and 15: Model No. "A", Min. "B", Max. PRDS304 5-1/2" 16-1/2" PRDS36 6 ...

  • Thermador PRG304 - page 16

    STEP B: Set the bracket on the floor and turn it until it is oriented properly. The long channel should be on the top with the free end facing towards you, one set of mounting flanges should be resting horizontally on the floor, and the other set of mount ing flanges should be positioned vertically facing the rear. STEP C: Slide the bracket to the ...

  • Thermador PRG304 - page 17

    CAUTION: “The appliance must be isolated from the gas supply piping system by closing its individual manual shut- off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa.).” “The appliance and its individual shut off valve must be disconnected from the gas supply piping sy ...

  • Thermador PRG304 - page 18

    STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING absence of local codes and ordinances, the power supply connection shall be in accor- dance with the National Electric Code. • Observe all governing codes and ordinances when ground- ing. In the absence of these codes or ordinances observe National Electrical Code ANSI/ NFPA No. 70 Curre ...

  • Thermador PRG304 - page 19

    STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GR OUNDING Dual Fuel models PRDS304, PRDS36 and PRDS48 must be connected to the power supply utilizing one of the following methods. For all methods of connection, the length of the cord or conduit/wiring must allow the unit to be slid completely out of the cabinet without having to unplug or discon ...

  • Thermador PRG304 - page 20

    Supply Wire ➝ Flat Washer ➝ ➝ FIG.17 Upper Nut Cupped Washer ➝ STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING A 3 or 4 conductor supply may be connected to the terminal block. A 4 conductor supply shall be used only when the range is installed in a mobile home or where local codes do not permit grounding through the neutral. 3 ...

  • Thermador PRG304 - page 21

    STEP 6: ELECTRICAL REQUIREMENTS, CONNECTION & GROUNDING Recommended Grounding Method – All-Gas Models PRG304, PRG36 and PRG48 The 30," 36" and 48" all-gas ranges are factory equipped with a power supply cord with a three-prong grounding plug (with polarized parallel blades). IT MUST BE PLUGGED INTO A MATING GROUNDING TYPE RECEP ...

  • Thermador PRG304 - page 22

    Chart D: BACKGUARD KIT MODEL NUMBERS RANGE MODEL NO. 9" STD. LOW BACK 12" LOW BACK 22" HIGH SHELF 1-1/2" ISLAND TRIM PRDS304/PRG304 Included with Range N/A PHS30T PRS30ITS PRDS36/PRG36 N/A PRS36LBS PHS36T PRS36ITS PRDS48/PRG48 N/A PRS48LBS PHS48T PRS48ITS FIG. 22 Front of Unit STEP 6: ELECTRICAL REQUIREMENTS, CONNECTIONS & G ...

  • Thermador PRG304 - page 23

    STEP 7: BA CKGU ARD INST ALLA TION STEP 8: TEST AND ADJUSTMENT Install any loose components, such as burner caps and grates, that may have been removed earlier. Be certain that burner caps seat properly into the alignment slots in the burner bases. Before testing operation of the appliance, verify that the unit and the gas supply have been carefull ...

  • Thermador PRG304 - page 24

    STEP 8: TEST AND ADJUSTMENT * The gas oven infra-red broiler burner has no air shutter and is not adjustable when used with natural gas. When used on propane gas, an air shutter is attached, but it is not adjustable. It is necessary to operate the oven broiler for 45 minutes to eliminate the harsh odor of the insulation binder. This must be done be ...

  • Thermador PRG304 - page 25

    INST ALLER CHECKLIST ❑ Manual gas shut off valve installed in an accessible location (without requiring removal of range). ❑ Unit tested and free of gas leaks. ❑ Gas supply pressure does not exceed 14" (37mb) W.C. ELECTRICAL ❑ Receptacle with correct over- current protection is provided for service cord connection. ❑ Proper ground co ...

  • Thermador PRG304 - page 26

    NO TES Page 24 ...

  • Thermador PRG304 - page 27

    NO TES Page 25 ...

  • Thermador PRG304 - page 28

    5551 McFadden Avenue, Huntington Beach, CA • 800/735-4328 ECO 14028 • 15-12-596C • © BSH Home Appliances Corp • Litho U. S. A. 4/01 For the most up to date critical installation dimensions by fax, use your fax handset and call 702/833-3600. Use code #8030. Specifications are for planning purposes only. Refer to installation instructions an ...

Производитель Thermador Категория Double Oven

Документы, которые мы получаем от производителя устройства Thermador PRG304 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Thermador
- инструкции обслуживания PRG304
- паспорта изделия Thermador
- информационные брошюры
- энергетические этикетки Thermador PRG304
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Thermador PRG304.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Thermador PRG304, инструкции обслуживания, короткие инструкции или инструкции пользователя Thermador PRG304. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Thermador PRG304.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Thermador PRG304, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Thermador PRG304 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Thermador PRG304.

Полная инструкция обслуживания Thermador, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Thermador PRG304 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Thermador PRG304, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Thermador PRG304, которое найдем в данном документе
3. Советы по использованию основных функций устройства Thermador PRG304 - которые должны облегчить нам первые шаги во время использования Thermador PRG304
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Thermador PRG304
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Thermador PRG304 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Thermador PRG304?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Thermador PRG304, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Thermador PRG304 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)