Инструкция обслуживания Hobart 652

40 страниц 1.3 mb
Скачать

Перейти на страницу of 40

Summary
  • Hobart 652 - page 1

    Cyber Flex 652 Model Processes Description Multiprocess W elding Arc Welding Power Source OM-278 163 769N June 2000 ...

  • Hobart 652 - page 2

    Hobart W elders manufactures a full line of welders and welding related equipment. For information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-877-Hobart1. Thank you and congratulations on ch ...

  • Hobart 652 - page 3

    The following terms are used interchangeably throughout this manual: MIG = GMAW T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Hobart 652 - page 4

    ...

  • Hobart 652 - page 5

    OM-278 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_5/97 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! Watch O ...

  • Hobart 652 - page 6

    OM-278 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87 ...

  • Hobart 652 - page 7

    OM-278 Page 3 1-3. Additional Symbols for Installation, Operation, and Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit. F A ...

  • Hobart 652 - page 8

    OM-278 Page 4 1-5. EMF Information Considerations About W elding And The Ef fects Of Low Frequency Electric A n d M a g n e t i c F i e l d s W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However , after examining more than 500 studies spanning ...

  • Hobart 652 - page 9

    OM-278 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_Fre 4/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives. Y Identifie un message de s é curit é particulier . ...

  • Hobart 652 - page 10

    OM-278 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage. LES RA YONS DE L ’ ARC peuvent pro- voquer des br û lures dans le ...

  • Hobart 652 - page 11

    OM-278 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables. D Ne pas installer l ’ appareil à proximit é de produits inflammables D Ne pas surcharger l ...

  • Hobart 652 - page 12

    OM-278 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American W el- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Safe Practice for the ...

  • Hobart 652 - page 13

    OM-278 Page 9 SECTION 2 – DEFINITIONS 2-1. General Precautionary Label W arning! Watch Out! There are possible hazards as shown by the symbols. 1 Electric shock from welding electrode or wiring can kill. 1.1 Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. 1.2 Protect yourself from electric sho ...

  • Hobart 652 - page 14

    OM-278 Page 10 2-2. Input Connection Label 1 W arning! Watch Out! There are possible hazards as shown by the symbols. 2 Electric shock from wiring can kill. 3 Disconnect input plug or power before working on machine. 4 Read the Owner ’ s Manual before working on this machine. 5 Consult rating label for input power requirements, and check power av ...

  • Hobart 652 - page 15

    OM-278 Page 1 1 2-5. Manufacturer ’ s Rating Label For CE Products S-174 343 . For label location see Section 3-4. ...

  • Hobart 652 - page 16

    OM-278 Page 12 2-6. Symbols And Definitions Some symbols are found only on CE products. NOTE A Amperes Amperage/V oltage Control – Panel Gas Tungsten Arc W elding (GT AW) Shielded Metal Arc W elding (SMA W) T emperature Wire Feeder Arc Force (DIG) Gas Metal Arc W elding (GMA W) Output Circuit Breaker Remote V V olts Positive High In- ductance Wel ...

  • Hobart 652 - page 17

    OM-278 Page 13 3-2. Duty Cycle And Overheating Duty Cycle is percentage of 10 m in - utes that unit can weld at rated load without overheating. If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. W ait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding. Y Exceeding duty cycle can damage unit and v ...

  • Hobart 652 - page 18

    OM-278 Page 14 3-4. Selecting A Location 1 Lifting Eye 2 Lifting Forks Use lifting eye or lifting forks to move unit. If using lifting forks, extend forks beyond opposite side of unit. 3 Rating Label (Non CE Models Only) Use rating label to determine input power needs. Label located under front access door . 4 Plate Label (CE Models Only) Label loc ...

  • Hobart 652 - page 19

    OM-278 Page 15 3-6. Tipping Y Be careful when placing or moving unit over uneven surfaces. 3-7. 1 15 V AC Receptacle And Circuit Breakers 3 Ref. ST-800 166-C Y T urn Off power before connecting to receptacle. 1 1 15 V 15 A AC Receptacle RC9 Power i s shared between RC9 a n d Remote 14 receptacle RC8 or terminal strip 1T (see Section 3-10). 2 Circui ...

  • Hobart 652 - page 20

    OM-278 Page 16 3-8. W eld Output T erminals And Selecting Cable Sizes Y ARC WELDING can cause Electromagnetic Interference. T o reduce possible interference, keep weld cables as short as possible, close together , and down low , such as on the floor . Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding ...

  • Hobart 652 - page 21

    OM-278 Page 17 3-10. Connecting Remote Control Ref. ST-800 170-E / Ref. S-0004-A / S-0750 1 Remote 14 Receptacle RC8 Connect remote control to RC8. If plug does not fit, wire cord to terminal strip 1T . Y T urn Off power before open- ing terminal strip cover . 2 T erminal Strip 1T 3 Remote Control Cord 4 Strain Relief (Customer Supplied) Secure cor ...

  • Hobart 652 - page 22

    OM-278 Page 18 3-1 1. Electrical Service Guide 60 Hz Models 50 Hz Models Input V oltage 230 460 575 380 400 440 520 Input Amperes At Rated Output 126 63 50.4 77 73 66 54 Max Recommended Standard Fuse Rating In Amperes 1 Time-Delay 2 150 70 60 90 90 80 60 Normal Operating 3 200 90 80 125 11 0 100 80 Min Input Conductor Size In A WG/Kcmil 1 6 6 4 4 4 ...

  • Hobart 652 - page 23

    OM-278 Page 19 3-12. Placing Jumper Links And Connecting Input Power 1 230 VOL TS Ref. S-174 973-A 575 VOL TS 460 VOL TS ST-800 103-B / Ref. ST -801 1 16 Check input voltage available at site. 1 Jumper Link Label Check label – only one is on unit. 2 Jumper Links Move jumper links to match input voltage. 3 Input And Grounding Conductors See Sectio ...

  • Hobart 652 - page 24

    OM-278 Page 20 SECTION 4 – OPERA TION 4-1. Controls (Non CE Models) 4 1 2 3 7 8 5 6 Ref. ST-184 939 1 Arc Force (Dig) Control Control increases SMAW short-circuit amperage which allows the operator to use a very short arc length without sticking the electrode. Set control at 0 for normal welding amper- age. T urn clockwise to increase short-circu ...

  • Hobart 652 - page 25

    OM-278 Page 21 4-2. Controls (CE Models) 4 Ref. ST-184 936 12 3 7 8 5 6 1 Arc Force (Dig) Control Control increases SMAW short-circuit amperage which allows the operator to use a very short arc length without sticking the electrode. Set control at 0 for normal welding amper- age. T urn clockwise to increase short-circuit amperage. 2 Process Selecto ...

  • Hobart 652 - page 26

    OM-278 Page 22 SECTION 5 – MAINTENANCE & TROUBLESHOOTING 5-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace unreadable labels. Clean and tighten weld terminals. Repair or replace cracked weld cable. 6 Months Blow out or vacuum inside. During heavy service, clean monthly . OR 5-2. Fuse F1 Ref. ST-800 101-C Y T urn ...

  • Hobart 652 - page 27

    OM-278 Page 23 5-3. T roubleshooting T rouble Remedy No weld output; unit completely inoperative; pilot light PL1 off. Place line disconnect device in On position (see Section 3-12). Check for open line fuse(s), and replace if open (see Section 3-12). Check for proper input power connections (see Section 3-12). Check for proper jumper link position ...

  • Hobart 652 - page 28

    OM-278 Page 24 Notes ...

  • Hobart 652 - page 29

    OM-278 Page 25 SECTION 6 – ELECTRICAL DIAGRAM SC-196 108-A For Primary Circuit Diagram Portion, refer to the Circuit Dia- gram located inside the wrapper of the welding power source. Figure 6-1. Circuit Diagram ...

  • Hobart 652 - page 30

    OM-278 Page 26 SECTION 7 – P ARTS LIST ST-800 703-D Figure 7-1. Main Assembly (652 Model Illustrated) . Hardware is common and not available unless listed. 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 14 17 18 (Fig.7 – 4) 19 20 21 1 22 3 4 23 25 26 24 27 28 (Fig. 7-2) 22 29 (Fig. 7-3) ...

  • Hobart 652 - page 31

    OM-278 Page 27 Description Part No. Dia. Mkgs. Item No. Figure 7-1. Main Assembly (652 Model Illustrated) Quantity 1 +179 432 P ANEL, side 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 179 431 COVER, top 1 . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Hobart 652 - page 32

    OM-278 Page 28 Description Part No. Dia. Mkgs. Item No. Figure 7-2. Panel, Front w/Components (Fig 7-1 Item 30) Quantity 1 159 863 ELECTRONICS BOX 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 PC1 187 834 CIRCUIT CARD, control (60Hz) 1 . . . . . . . . . . . . . . . . ...

  • Hobart 652 - page 33

    OM-278 Page 29 Description Part No. Dia. Mkgs. Item No. Figure 7-2. Panel, Front w/Components (Fig 7-1 Item 30) (Continued) Quantity 14 174 937 PLA TE, control lower (60Hz) 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 179 389 PLA TE, control lower (50Hz) 1 . . . . . . . . . . . ...

  • Hobart 652 - page 34

    OM-278 Page 30 Description Part No. Dia. Mkgs. Item No. Figure 7-3. Rectifier , Si Diode (Fig 7-1 Item 31) Quantity 1 C7.12 048 420 CAP ACITOR, cer disc .01uf 1000VDC 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 191 989 BAR, mtg rectifier 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Hobart 652 - page 35

    OM-278 Page 31 Description Part No. Dia. Mkgs. Item No. Figure 7-4. Panel, Rear w/Components (Fig 7-1 Item 18) Quantity 1 124 275 CHAMBER, plenum 14 in 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 180 165 BLADE, fan 14 in 3wg 23deg .375 bore CCW 1 . . . . . . . . . . . . . ...

  • Hobart 652 - page 36

    Notes ...

  • Hobart 652 - page 37

    ...

  • Hobart 652 - page 38

    ...

  • Hobart 652 - page 39

    Warranty Questions? Call 1-877-HOBART1 for your local Hobart distributor. hobart standard 7/00 Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor or call 1-800-332-3281. The expertise of the distribu ...

  • Hobart 652 - page 40

    PRINTED IN USA  2000 Hobart Welding Products. 1/00 Hoba rt We lding Produc ts An I l li noi s T ool Works Company 600 West Main St reet Troy , OH 45373 U SA For Technical A ssistan ce: Call1-800-332-3281 For Li terat ure Or Neares t Dealer: Call 1-877-Hobart 1 Model Name Serial/Style Number Purchase Date (Date which equipment was delivered to or ...

Производитель Hobart Категория Welding System

Документы, которые мы получаем от производителя устройства Hobart 652 мы можем разделить на несколько групп. Это в частности:
- технические чертежи Hobart
- инструкции обслуживания 652
- паспорта изделия Hobart
- информационные брошюры
- энергетические этикетки Hobart 652
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Hobart 652.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Hobart 652, инструкции обслуживания, короткие инструкции или инструкции пользователя Hobart 652. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Hobart 652.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Hobart 652, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Hobart 652 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Hobart 652.

Полная инструкция обслуживания Hobart, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Hobart 652 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Hobart 652, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Hobart 652, которое найдем в данном документе
3. Советы по использованию основных функций устройства Hobart 652 - которые должны облегчить нам первые шаги во время использования Hobart 652
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Hobart 652
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Hobart 652 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Hobart 652?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Hobart 652, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Hobart 652 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)