    Global leaders in sleep and respiratory medicine www.resmed.com Ultra Mirage™ NoN-veNted full face mask Clinical Guide English ...

  • ResMed 1 - page 2

    Note: F or complete instructions, read the te xt section in conjunction with the illustrations on this sheet. Hi nw eis: V ollständige A nw eisungen finden Sie im Te xtabschnit t und in den Illustrationen auf diesem Blat t. Remarque : pour les instr uctions complètes, veuillez lire le texte du guide av ec cet te fic he d'illustrations. Not ...

  • ResMed 1 - page 3

    B B-1 B-2 B-3 B-4 B-5 B-6 © 20 1 1 ResMed Ltd. 1 3 4 2 Fo rehead support tab / Stirnbauteillasc he / languet te du support frontal / Linguet ta del supporto frontale / Lengüeta del apo yo para la frente / Dispositivo de fixação do suporte da testa / T ab van de voorhoofdsteun Fitting the Mask / Anlegen der Maske / Mise en place du masque / Com ...

  • ResMed 1 - page 4

    D-1 D-6 D-3 a b D-5 D-2 D-4 D D-7 © 20 1 1 ResMed Ltd. Reassembling the Mask / Wieder zusammenbau der Maske / Remontage du masque / Riassemblaggio della masc hera / Mont aje de la mascarilla / Montagem da máscara / Het masker opnieuw monteren Luer lock por ts cap / Ansc hlusskappen für Luer-Verbindungss tü ck / Bouc hon(s) d'entrée de rac ...

  • ResMed 1 - page 5

    English 1 Ultra Mirage ™ NON-VENTED FULL F ACE MASK The Ultra Mirage NV (non-vented) F u ll F ace Mask is a non-inv asive device used for c hannelling air flow with or w ithout supplemen tal oxy gen. Int ended Use The Ultra Mirage NV F ull Face Mask is in tended to be used w ith active-exhaust- valv e ventilator sy stems, to provide ventilatory a ...

  • ResMed 1 - page 6

    2 the ventilator enclosure. Oxygen accu mulated in the ventilator enclosure will creat e a risk of fire. This w arnin g applies to most types of ventilators. • Please refrain from smoking while oxy gen is in use. • Using a mask may cause tooth, gum or jaw soreness or aggravate an existing dental condition. If symptoms occur , consult y our phys ...

  • ResMed 1 - page 7

    3 English 5 Gently tighten the low er headgear straps (B-4). The pads of the forehead support sh ould sit comfortably o n the forehead when the mask is in place. If the pads are at an angle and not completely seated on the forehead, c h ange the position of the forehead support tab. Note: Do not overtighten the headgear stra ps as this may cause di ...

  • ResMed 1 - page 8

    4 Simply pull the Emergency Release Cord and the two part clip separates, allow ing you to remo ve the mask from the face. Figure 1: Emer gency Release Cord. Note : T he Eme rgency R elease Cord should only be used to remove the mask in the ev ent of an emergency . Ov eruse of the Emergency Release Cord may result in the deterioration of the t w o ...

  • ResMed 1 - page 9

    5 English Cleaning the Mask in the Home Notes: • W ash your hands before cleaning the mask. • It is important to alway s handwash the headgear . • The headgear ma y be washed without being disassembled from the headgear clips. Daily/After each use Handwash the mask components in warm (appro ximately 30ºC) water for one minute using mild soap ...

  • ResMed 1 - page 10

    6 3 T o at tac h the elbow retainer , fit one side of the elbow retainer against the groov e of the elbow . While holding one wing of the elbow retainer down (D-3a) , press the other wing do wn until it clic ks into place (D-3b) . 4 Rotate the elbo w ret ainer to its original position (D-4) . 5 Chec k that you hav e fit ted the elb o w and elbow re ...

  • ResMed 1 - page 11

    7 English Dead Space Dead space is the empt y v olume of the mask up to the elbow . The dead space of the mask v aries accord ing to cushion sizes but is less than 260 mL. Standards CE designation in accordance with EC directive 93/42/EEC, class IIa . EN ISO 1 4971, ISO 535 6-1, ISO 594-1, ISO 1 0993-1 and ISO 1 3485. Operating Pressure 0 to 40 cm ...

  • ResMed 1 - page 12

    8 Clinical Guide Or der ing Infor mation T emperature limitation Does not contain natural r ubber latex Manufact urer Indicates a W arning or Cautio n and al erts you to a possible injur y or explains special measures f or the sa fe and ef fectiv e use of the device. Pa rt N o . I te m Syst e m 60643 UM NVFFM Sy stem Small, Standard – Europe 1 60 ...

  • ResMed 1 - page 13

    9 English Europe 1 - English, German, F renc h, It alian, Spa nish, P ort uguese, Dutc h. Consumer W ar ranty ResMed ac knowledges all consumer rights granted under the EU Directive 1 999/44/EG and the respective national laws w ithin the EU for products sold within the European Union. 60 1 24 F orehead pad (1 0 pk.) 60675 Mask F rame, Small (1 pk. ...

  • ResMed 1 - page 14

    Manuf acturer: ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Distr ibuted by: ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA ResMed (UK) Ltd 96 Milton Park Abingdon Oxfordshire OX14 4RY UK See www .resmed.com for other ResMed locations worldwide. For patent information, see www .resmed.com/ip Ultra Mirage ...

  • ResMed 1 - page 15

    Global leaders in sleep and respiratory medicine www.resmed.com 608323/1 2011-12 Ultra Mirage NVFFM CLINICAL EUR 1 - ENG 608323 ...

Производитель ResMed Категория Nebulizer

Документы, которые мы получаем от производителя устройства ResMed 1 мы можем разделить на несколько групп. Это в частности:
- технические чертежи ResMed
- инструкции обслуживания 1
- паспорта изделия ResMed
- информационные брошюры
- энергетические этикетки ResMed 1
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания ResMed 1.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа ResMed 1, инструкции обслуживания, короткие инструкции или инструкции пользователя ResMed 1. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия ResMed 1.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства ResMed 1, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании ResMed 1 пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей ResMed 1.

Полная инструкция обслуживания ResMed, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией ResMed 1 - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания ResMed 1, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся ResMed 1, которое найдем в данном документе
3. Советы по использованию основных функций устройства ResMed 1 - которые должны облегчить нам первые шаги во время использования ResMed 1
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем ResMed 1
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра ResMed 1 в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся ResMed 1?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с ResMed 1, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с ResMed 1 со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)