Инструкция обслуживания Amana PACKAGE HEAT PUMP

20 страниц 0.66 mb
Скачать

Перейти на страницу of 20

Summary
  • Amana PACKAGE HEAT PUMP - page 1

    Goodman Company, L.P. 1810 Wilson Parkway • Fayetteville, Tennessee 37334 www .amana-hac.com Installer: Affix literature adjacent to the unit. Part No. 10730420 Printed in USA  2000-2004 Goodman Company , L.P . Effective: July 2004 ® is a trademark of Maytag Corporation and is used under license to Goodman Company , L.P . All rights reserved. ...

  • Amana PACKAGE HEAT PUMP - page 2

    2 R ECOGNIZE S AFETY S YMBOLS , W ORDS , AND L ABELS The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner ’s and installer’s responsibility to read and comply with all safety information and instructions accompanying these symbols. Failure to heed safety information ...

  • Amana PACKAGE HEAT PUMP - page 3

    3 GENERAL INFORMA TION T O T HE I NSTALLER Before installing this unit please read this manual and the Product Data Book applicable to your model* to familiarize yourself on the specific items which must be adhered to such as maximum external static pressure to unit, air temperature rise, minimum or maximum CFM and motor speed connections. T O T HE ...

  • Amana PACKAGE HEAT PUMP - page 4

    4 blower section, to allow splicing-in of field-installed wiring, or con- nect to terminal strip in unit control box. See the unit wiring diagram for electrical connections. C/X G Y R O W W1 W2 C/ X G Y R O W1 W2 E ROOM THERMOS T AT OUTDOOR UNIT PH__C02E Wiring shown i s for D9945804 (THSMEC1H2 BA) thermostat. C/X G Y R O W W1 W2 C/ X G Y R O W2 E ...

  • Amana PACKAGE HEAT PUMP - page 5

    5 ON ON CG Y R W W 1 W2 O Low Voltage Term inal St rip Low Voltage Connection Heater Kit Control Box Low Vol t age Termina l Strip Low Voltage Connection Unit Control Box C G Y R W W1 W2 O 123 456 789 1 3 L2 L1 4 5 T HE RMOS TA T CB1 GY BU RD 0R GY BU RD BR BR BR YL YL BK VT RD VT BR BK BK RD RD BU BK BK BK BK BK BK OL OL 10K W FIE LD CO NNECT IO N ...

  • Amana PACKAGE HEAT PUMP - page 6

    6 Remo ve Loosen Duct Removal 3. Remove the clamp securing the blower assembly to the bottom of the unit. Discard clamp and screws. Remo ve } { Ai rflo w Clamp Removal 5. Rotate the blower assembly 90° clockwise, setting the blower assembly outlet on the panel removed from bottom of the unit. Ensure the blower motor is oriented with the motor wire ...

  • Amana PACKAGE HEAT PUMP - page 7

    7 CLI PS SELF-DRIL LING SCREWS Cover Clip Installation 3. Attach 16x16 horizontal covers using screws provided with kit to the outer duct opening flange and cover clip holes. 4. Secure the center of the top flat cover flange to the unit using a self-drilling screw included with the unit. Horizontal Duct Cover Installation D UCTWORK Duct systems and ...

  • Amana PACKAGE HEAT PUMP - page 8

    8 2- 1/2" of 3/4" P VC Co nden sa te Dra in Trap 90° E LL 1- 1/2" Minimu m dr op at out let Figure 13 - Condensate Drain Connection NORMAL SEQUENCE OF OPERA TION NOTE: There is a fan delay on initial power to unit before the low voltage board resets and is operational. 1. Thermostat calls for heating or cooling. The compressor and o ...

  • Amana PACKAGE HEAT PUMP - page 9

    9 ACCESSORIES Hor iz ontal D uc t C ov ers (CHK 001A ) S ingle P oint P o wer C onnec tions ( S P K * *A ) Roof Curb - Heat P um p ( P RC06A 1) Roof Curb - Univ ers al (P RC08A 1) O v er -Under t o S ide by S ide ( P DT ROU 4A ) O v er -Under t o S ide by S ide ( P DT ROU 6A ) Additional accessories, as described above, can be purchased to fit spec ...

  • Amana PACKAGE HEAT PUMP - page 10

    10 WARNING TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEA TH, DISCONNECT ELECTRICAL POWER T O THIS FURNACE BEFORE SERVICING OR PERFORMING MAINTENANCE. PHB[24-36]C02* 1 Ø WIRING 75 °C MIN 208/230 VAC 1 Ø 1 90 60 30 TEST TEST AL TE R N A TE CONFIGURA TI ON XFMR -R R XFMR -C C G NO NC COM G C XFMR C XFMR R R COM NC NO WH-7 YL YEL LOW OR ORA NGE ...

  • Amana PACKAGE HEAT PUMP - page 11

    11 PHB[42-48]C02** 1Ø WI RI NG 208/ 230 V AC 1Ø 75°C M IN 208/ 230 V A C 1Ø 1 90 60 30 TEST TEST ALTERNATE CONFIGURAT I ON XFMR -R R XFMR -C C G NO NC COM G C XFMR C XFMR R R COM NC NO WH-7 YL YE LLOW OR ORA NGE VT V IOLET GN GRE EN BK BL ACK BR B ROWN WH WHITE BU BLUE GY GR AY RD RE D CO L OR CO DE LOW VO L TAGE LOW VOLT AGE F IELD HI VOLT AGE ...

  • Amana PACKAGE HEAT PUMP - page 12

    12 WARNING TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEA TH, DISCONNECT ELECTRICAL POWER T O THIS FURNACE BEFORE SERVICING OR PERFORMING MAINTENANCE. PHB60 / PHD48C02** 1Ø WI RI NG 208/ 230 V AC 1 Ø 75 °C MIN 1 90 60 30 TEST TEST ALTERNATE CONFIGURAT I ON IN DUCTOR (OP TIONA L ) INDUCTOR ( OPTIONAL) YL YE LLOW OR ORA NGE VT V IOLET GN GRE E ...

  • Amana PACKAGE HEAT PUMP - page 13

    13 PHD[24-36]C02** WARNING TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEA TH, DISCONNECT ELECTRICAL POWER T O THIS FURNACE BEFORE SERVICING OR PERFORMING MAINTENANCE. 208/ 230 V AC 1 Ø LOW YLB K SWITC H PRES SURE LOW WH-7 G C G Y - 5 5 YL- 27 BR -21 RD- 13 OR-49 DF2 DF1 C Y O O W 2 R R D F T T E S T 3 0 6 0 9 0 BO ARD DEFR OST BU -34 VT- 18 B ...

  • Amana PACKAGE HEAT PUMP - page 14

    14 PHD42C02** WARNING TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEA TH, DISCONNECT ELECTRICAL POWER T O THIS FURNACE BEFORE SERVICING OR PERFORMING MAINTENANCE. 1 Ø WI RI NG 208/ 230 V AC 1 Ø 75°C M IN 1 90 60 30 TEST TEST 90 60 30 TEST TEST ALTERNAT E CONFIGUR ATION YL YE LLOW OR OR ANGE VT VIOL ET GN GR EEN BK B LACK BR B ROWN WH W HITE B ...

  • Amana PACKAGE HEAT PUMP - page 15

    15 PHD60C02** WARNING TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEA TH, DISCONNECT ELECTRICAL POWER T O THIS FURNACE BEFORE SERVICING OR PERFORMING MAINTENANCE. 1Ø WI RI NG 208/ 230 V AC 1 Ø 75 °C MI N 1 90 60 30 TEST TEST ALTERNATE CONFIGURAT I ON IN DUCTOR (OP TIONA L ) INDUCTOR ( OPTIONAL) Y1 2ND ST AG E COOL RELAY 2ND STAG E DEFR RELAY ...

  • Amana PACKAGE HEAT PUMP - page 16

    16 PHB[24-36]CC2** WARNING TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEA TH, DISCONNECT ELECTRICAL POWER T O THIS FURNACE BEFORE SERVICING OR PERFORMING MAINTENANCE. 1 Ø WIRING 75 °C MIN 1 90 60 30 TEST TEST AL TE R N A TE CONFIGURA TION XFMR -R R XFMR -C C G NO NC COM WH-7 YL YEL LOW OR ORA NGE VT VIO LET GN GRE EN BK B LACK BR BROWN WH W H ...

  • Amana PACKAGE HEAT PUMP - page 17

    17 PHD[24-36]CC2** ALTERNATE CONFIGURAT I ON T E S T 3 0 6 0 9 0 RD- 27 TEST TEST 30 60 90 T2 GND T1 YLB K SWITC H PRES SURE LOW ACCE SS ORY INS TALLATI ON INSTRUCTION S. HE ATER ACCES SORIE S. SEE HEAT ER LEA DS M AY BE USED WIT H ELEC TRI C ALT ERNAT E UNI T POWER REF RIGE RANT GN BK RD YL BK WH-7 LOW G C G Y - 5 5 YL- 27 BR -21 RD- 13 OR-49 DF ...

  • Amana PACKAGE HEAT PUMP - page 18

    18 WARNING T O A VOID PROPERTY DAMAGE , PERSONAL INJURY OR DEAT H DUE TO FIRE , CLEARANCES TO COMBUSTIBLE SURF ACES LISTED AS SHOWN MUST BE OBSER VED . CLEARANCES 36" Maximum O ver ha ng 48" Min im um Overhang 36" S i d e Clear an ce for Servicing Re com m e nd ed Minimu m 9" Cleara nce to C om b us ti bl es 3 6" Clearance ...

  • Amana PACKAGE HEAT PUMP - page 19

    19 ...

  • Amana PACKAGE HEAT PUMP - page 20

    20  2000-2004 Goodman Company , L.P . Effective: July 2004 ...

Производитель Amana Категория Electric Heater

Документы, которые мы получаем от производителя устройства Amana PACKAGE HEAT PUMP мы можем разделить на несколько групп. Это в частности:
- технические чертежи Amana
- инструкции обслуживания PACKAGE HEAT PUMP
- паспорта изделия Amana
- информационные брошюры
- энергетические этикетки Amana PACKAGE HEAT PUMP
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Amana PACKAGE HEAT PUMP.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Amana PACKAGE HEAT PUMP, инструкции обслуживания, короткие инструкции или инструкции пользователя Amana PACKAGE HEAT PUMP. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Amana PACKAGE HEAT PUMP.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Amana PACKAGE HEAT PUMP, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Amana PACKAGE HEAT PUMP пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Amana PACKAGE HEAT PUMP.

Полная инструкция обслуживания Amana, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Amana PACKAGE HEAT PUMP - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Amana PACKAGE HEAT PUMP, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Amana PACKAGE HEAT PUMP, которое найдем в данном документе
3. Советы по использованию основных функций устройства Amana PACKAGE HEAT PUMP - которые должны облегчить нам первые шаги во время использования Amana PACKAGE HEAT PUMP
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Amana PACKAGE HEAT PUMP
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Amana PACKAGE HEAT PUMP в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Amana PACKAGE HEAT PUMP?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Amana PACKAGE HEAT PUMP, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Amana PACKAGE HEAT PUMP со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)