Инструкция обслуживания Milwaukee 1500HT

27 страниц 1.19 mb
Скачать

Перейти на страницу of 27

Summary
  • Milwaukee 1500HT - page 1

    INSTALLATION AND OPERATION MANUAL RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE THIS APPLIANCE MUST BE INSTALLE D BY A QUALIFIED INSTALLER. READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION. P P/N 775001M, Rev. Q, 12/03 MODEL 1500HT EPA CERTIFIED WOOD BURNING STOVE ...

  • Milwaukee 1500HT - page 2

    IMPORTANT WARNINGS CAUTION: PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FOR YOUR SAFETY, FOLLOW THE INST ALLATION, OPERATION AND MAINTENANCE INSTRUC- TIONS EXACTLY, WITHOUT DEVIATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. IF THIS APPLI ANCE IS NOT PROPER ...

  • Milwaukee 1500HT - page 3

    PAGE 3 TABLE OF CONTENTS Important Warn ings ................................................ 2 Testing/Listing, EPA, Using this Manual .................. 3 Planning Your Inst allation ..................................... 4-6 Manufactured (Mobile) Ho me Requirements ........... 6 Installati on ...................................................... ...

  • Milwaukee 1500HT - page 4

    PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood burning appliances are improperly installed. The installer must follow all of the manufacturers’ in- structions. The installation of a wood burnin ...

  • Milwaukee 1500HT - page 5

    PLANNING YOUR INSTALLATION PAGE 5 COMBUSTIBLE WALL CLEARANCE WARNING: IT IS VERY IMPORTANT THAT YOU OBSERVE THE MINIMUM CLEARANCES. There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney. Minimums are first estab- lished for the stove itself and increased base ...

  • Milwaukee 1500HT - page 6

    PLANNING YOUR INSTALLATION PAGE 6 REDUCED MASONRY ST RUCTURE CLEARANCE (ALCOVE) Your Earth Stove can be installed in a masonry struc- ture with reduced clearances if the structure was built to National Building Code for fireplaces and chimneys (UBC 37). The firebox of the masonry structure must be of ade- quate size to allow a minimum of 6" (1 ...

  • Milwaukee 1500HT - page 7

    INSTALLATION PAGE 7 Once the outside air floor duct is in position, replace the floor protector. Make sure that the floor protector's hole is aligned with the outside air opening. Next position and align the stove on the hearth pad. Manufactured (mobile) home installations require that the stove be secured to the floor. This ens ures that the ...

  • Milwaukee 1500HT - page 8

    INSTALLATION PAGE 8 INSTALLING THE BAFFLE BRICKS There are 2 brick retainer tube assemblies located be- low the ceiling of the firebox which require baffle brick before the stove can be operated. Install the baffle brick as follows: 1. Place the first three brick onto the brick retainers with the notch facing up and toward the front. Next, slide th ...

  • Milwaukee 1500HT - page 9

    INSTALLATION PAGE 9 ACCEPTABLE CONNECTOR PIPE FOR INSTALLA- TIONS For Standard Residential Clearances: Six 6 inch (152 mm) minimum, single wall, 25 gage minimum thickness, stove pipe is acceptable. Three (3) pre-drilled holes are provided in the flue collar fo r fastening the pipe securely to the stove. Use sheet metal screws to do this. Addi- tion ...

  • Milwaukee 1500HT - page 10

    INSTALLATION PAGE 10 CHIMNEY HEIGHT REQUIREMENTS The chimney must extend 3 feet (914 mm) above the level of roof penetration and a minimum of 2 feet (610 mm) higher than any roof surface within 10 feet (305 cm) (see below). Check with your local building officials for any additional requirements for your area. Due to prevailing winds, local terrain ...

  • Milwaukee 1500HT - page 11

    INSTALLATION PAGE 11 RESIDENTIAL STANDARD Using 6” (152 mm) Diameter Single Wall Con- nector Pipe Not Approved For Manufactured (Mobile) Home MANUFACTURED (MOBILE) HOME STANDARD Using 6” (152 mm) Diameter Ty pe L-Vent Connector Pipe ...

  • Milwaukee 1500HT - page 12

    INSTALLATION Combustible Wall Chimney Connector Pass-Throughs NOTES: 1. Connectors to a masonry chimney , excepting method B, shall ext end in one continuous section through the wall pass-through syste m and the chimney wall, to but not past the inner flue liner face. 2. A chimney connector shall not pass through an attic or roof space, closet or s ...

  • Milwaukee 1500HT - page 13

    PRODUCT FEATURES AND CONTROLS CARE AND OPERATI0N PAGE 13 ASH DRAWER The large ash drawer located on the left side of the ped- estal is designed to make cleaning easier by containing the ashes in a removable drawer. CAUTION: DO NOT OPERATE THE STOVE WITH THE ASH DRAWER OPEN OR AJAR, AS THIS WILL PRODUCE EXTREME TEMPERATURES WITHIN THE STOVE (OVERFIR ...

  • Milwaukee 1500HT - page 14

    CARE AND OPERATION PAGE 14 PRIMARY AIR CONTROL This appliance is equipped with a control for the combustion air, located on the lower right si de (front) of the stove. Slid- ing the control to the right increases the burn rate, to the left decreases the burn rate. You will generally want to set the control in the low or me- dium range. The stove is ...

  • Milwaukee 1500HT - page 15

    FUEL PAGE 15 BURN RECOMMENDED FUEL This appliance is approved for use with untreated natural dry wood only (see Important Warnings , page 2, #8). Do not burn particleboard scraps or pressed logs using bond- ing agents because they can produce conditions that will deteriorate metal. Green or uncured wood does not work well as fuel, and can cause inc ...

  • Milwaukee 1500HT - page 16

    MAINTENANCE PAGE 16 SMALL AREA PAINT TOUCH-UP The stove body is painted with a quality high-temperature stove paint. Use only model TSPK-B Stove Paint, Catalog # 70K99. Do not touch-up your stove with any other paint. Using one small piece of 320 grit sand paper and lightly sand the blemish so that the edges are “feathered” or smooth to the tou ...

  • Milwaukee 1500HT - page 17

    MAINTENANCE PAGE 17 Replacing Glass: 1. Remove door from stove by lifting door up and off hinge pins: Place the door on a flat protected (towel) clean flat surface with the inside of the door facing up. Remove the glass clips (by removing screws holding clips), then care- fully remove broken glass one piece at a time (protective gloves are recommen ...

  • Milwaukee 1500HT - page 18

    TROUBLESHOOTING PAGE 18 SMOKES OUT FUEL DOOR WHEN OPEN (see ✸ ) 1. The primary air control is closed. 2. The chimney is too cool. Set the primary air control on "HIGH" for a few minutes before opening the fuel door. 3. Excess creosote will not only re strict your draft but it will create a risk of a creosote fire. Strictly adhere to mai ...

  • Milwaukee 1500HT - page 19

    TROUBLESHOOTING PAGE 19 The following are a few conditions that should be evaluated and (corrected if necessary) if an overfiring condition is sus- pected: Overfiring Caused From Improper Installation - Ensure that all installation requirements have been met as outlined in the installation manual. The chimney should be clean and in good repair. A d ...

  • Milwaukee 1500HT - page 20

    SPECIFICATIONS: Model 1500 HT PAGE 20 Approximate heating capacity Up to ~1500 Sq. Ft. (Up to ~450 Sq. M) Outside air provision Yes Log length 20" (508 mm) Flue position Top Flue collar size 6" (152 mm) Width 27 1/2" (699 mm) Depth 24" (610 mm) Height (to flue) 30 3/4" (781 mm) Height 29 3/4" (756 mm) Stove back to flu ...

  • Milwaukee 1500HT - page 21

    REPLACEMENT PARTS LIST - Model 1500HT PAGE 21 PART NO. DESCRIPTION Door Parts G6000 Door Assembly, Cast Black 14M72 Door Assembly, Gold 27M67 Clip Set, Glass 86-128 Door Gasket Kit, 3/4" Rope (includes adhesive) 27M81 Gasket, Glass Channel (Per Foot) G2000-7 Glass, Arched 9 1/2 X 15 3/4" (glass gasket not included) 10300 Handle Assembly ( ...

  • Milwaukee 1500HT - page 22

    COMPONENT DIAGRAMS – Model 1500HT FIREBRICK Part/Catalog # Quantity Dimensions Part/Catalog # Quantity Dimensions FB-1 6 9 x 4 1/2” FB11 1 4 1/2” x 4 3/8” FB2 10 9 x 4 1/2” w/notch 10545 5 * 9 x 4 1/2” w/notch 01115 1 Grate FB-5 1 9 x 2 1/2” w/hole * Baffle brick are a special dens er brick. Do not substi- tute Note: All brick are 1 ? ...

  • Milwaukee 1500HT - page 23

    OPTIONAL ACCESSORIES – Model 1500HT Note: Install and use accessories per instructions provided with the accessory kit. PAGE 23 Catalog # Model # Description Notes 14M67 OAFD-S Outside Air Floor Duct 5 1/4" Square 14M72 DK100-G Gold Door Kit 14M22 BK-100 Blower Kit Includes Dial-A- Temp for Variable Speed Control 14M21 SSK Stove Stat Kit T h ...

  • Milwaukee 1500HT - page 24

    SAFETY/LISTING LABEL PAGE 24 ...

  • Milwaukee 1500HT - page 25

    EPA LABEL PAGE 25 ...

  • Milwaukee 1500HT - page 26

    Page 26 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

  • Milwaukee 1500HT - page 27

    1110 West Taft Avenue Orange, CA 92865 ...

Производитель Milwaukee Категория Stove

Документы, которые мы получаем от производителя устройства Milwaukee 1500HT мы можем разделить на несколько групп. Это в частности:
- технические чертежи Milwaukee
- инструкции обслуживания 1500HT
- паспорта изделия Milwaukee
- информационные брошюры
- энергетические этикетки Milwaukee 1500HT
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Milwaukee 1500HT.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Milwaukee 1500HT, инструкции обслуживания, короткие инструкции или инструкции пользователя Milwaukee 1500HT. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Milwaukee 1500HT.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства Milwaukee 1500HT, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании Milwaukee 1500HT пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Milwaukee 1500HT.

Полная инструкция обслуживания Milwaukee, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией Milwaukee 1500HT - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Milwaukee 1500HT, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся Milwaukee 1500HT, которое найдем в данном документе
3. Советы по использованию основных функций устройства Milwaukee 1500HT - которые должны облегчить нам первые шаги во время использования Milwaukee 1500HT
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Milwaukee 1500HT
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Milwaukee 1500HT в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся Milwaukee 1500HT?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с Milwaukee 1500HT, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с Milwaukee 1500HT со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)