Bedienungsanleitung Sennheiser FT-906B20

40 Seiten 2.51 mb
Download

Zur Seite of 40

Summary
  • Sennheiser FT-906B20 - page 1

    INSTRUCTION FOR USE EM 203 ...

  • Sennheiser FT-906B20 - page 2

    CONTENTS 1 TECHNICAL OVERVIEW 1.1 Computer Control 1.2 Diversity 1.3 HIDYN plus ® noise reduction system 1.4 Block diagrams 2 POSSIBLE TRANSMITTER/RECEIVER COMBINATIONS 2.1 EM 203 receiver/SK 2012 TV(HiDyn plus ® ) and SKM 4031 HiDyn plus ® 2.2 EM 203 receiver/SK 50/250 UHF and SKM 5000 (HiDyn plus ® ) 2.3 EM 203 receiver/SER 20 transceivers 3 ...

  • Sennheiser FT-906B20 - page 3

    Introduction The wireless Mikroport multi-channel sound transmission system EM 1046 is a transmitter/receiver system in a modular design. It offers comfortable handling and can be relied on for dependable service. • 3-channel diversity receiver EM 203 with microprocessor-controlled receiver modules • Ultimate flexibility in the selection of tra ...

  • Sennheiser FT-906B20 - page 4

    T echnical overview 1 Computer control 1.1 Diversity 1.2 HiDyn plus ® noise reduction 1.3 Block diagrams 1.4 ...

  • Sennheiser FT-906B20 - page 5

    Every single EM 1046 RX receiver module has an in-built micro- processor for the RF section, the operating elements and all indicators. It serves to control the following components or parameters: • phase locked loop (PLL) synthesizer • function of keys • 8 digit LED display • two LED bargraph displays • true diversity • monitoring • ...

  • Sennheiser FT-906B20 - page 6

    Diversity 1.2 Every EM 1046 RX receiver module operates on true diversity. An antenna splitter, integrated into the chassis, serves to route the antenna signals from both antennas to the three receiver modules. The receiving antenna not only receives direct electromagnetic waves, but also reflections from walls, windows, ceilings and other installa ...

  • Sennheiser FT-906B20 - page 7

    HiDyn plus ® 1.3 »HIDYN plus ® « NOISE REDUCTION SYSTEM The »HIDYN plus ® « noise reduction system serves to reduce the effects of RF interference fields. It increases the signal-to-noise ratio and gets close to about 110 dB for peak modulation. »HIDYN plus ® « is a wideband compander system. It is a combination of a compressor at the tra ...

  • Sennheiser FT-906B20 - page 8

    Block diagram EM 203 1.4 ...

  • Sennheiser FT-906B20 - page 9

    Possible transmitter/ 2 receiver combinations EM 203 receiver/ 2.1 SK 2012 TV (HiDyn plus ® ) and SKM 4031 TV-HiDyn plus ® T ransmitters EM 203 receiver/ 2.2 SK 50/250 UHF and SKM 5000 (HiDyn plus ® ) T ransmitters EM 203 RECEIVER/ 2.3 SER 20 TRANSCEIVER ...

  • Sennheiser FT-906B20 - page 10

    2.1 EM 203 receiver/ SK 2012 TV (HiDyn plus ® ) and SKM 4031 TV -HiDyn plus ® AB 1036 TV 2 GZA 1036 TV 450 - 800 MHz or 2 GZA 1036-9 140 -960 MHz SKM 4031 TV-HiDyn plus ® SK 2012 TV (HiDyn plus ® ) MKE 10-2 R MKE 102-2 R MKE 2-2 R EM 203 receiver NOTA BENE NOTA BENE SK 2012 body-pack transmitters can be retrofitted (change from HIDYN ® to HIDY ...

  • Sennheiser FT-906B20 - page 11

    EM 1046/ SK 50 UHF / SK 250 UHF and SKM 5000 2.2 2 GZA 1036 TV 450 - 800 MHz or 2 GZA 1036-9 140 -960 MHz SK 50 UHF / SK 250 UHF AB 1036 TV MKE 10-4 MKE 2-4 MKE 102-4 SKM 5000 EM 203 receiver ...

  • Sennheiser FT-906B20 - page 12

    EM 203 receiver/ 2.3 SER 20 transceiver SER 20 transceiver with HiDyn plus © 2 GZA 1036 TV 450 - 800 MHz or 2 GZA 1036-9 140 -960 MHz Retrofitted SER 20 transceivers (change from HIDYN © to HIDYN plus © ) can be used in conjunction with EM 203 receivers. Refer retrofitting to Sennheiser distributors or Sennheiser's Service Department, 30900 ...

  • Sennheiser FT-906B20 - page 13

    MANIPULA TION FUNCTION DISPLA Y (RX) 13 EM 203, Publ. 10/94 engl Putting the EM 203 receiver 3 to work M ains connection 3.1 A ntenna connection 3.2 A F connection 3.3 S tart-up procedure/ operating indicators 3.4 ...

  • Sennheiser FT-906B20 - page 14

    Power is supplied by a plug-in power supply unit. The power module is available as a 110, 230 or 240 V AC model. The unit can easily be adapted to changing power requirements by replacing the power module. Connection of the plug-in power supply unit is via socket P at the back panel of the EM 203. Mains connection 3.1 The two antennas needed for di ...

  • Sennheiser FT-906B20 - page 15

    MANIPULA TION FUNCTION DISPLA Y (RX) 15 EM 203, Publ. 10/94 engl This is how the channel module indicates that it is ready for operation (after power-up). The three LED indicators for the operating voltages light up (see ch. 4.2.1 ). The display changes after about 5 seconds It shows the frequency on which the mdoule is operating or the name of the ...

  • Sennheiser FT-906B20 - page 16

    A vailable modules 4 EM 1046 RX 4.1 receiver module Monitor 4.2 ...

  • Sennheiser FT-906B20 - page 17

    EM 1046 RX receiver module 4.1 Adjustment 4.1.1 Receiver frequencies 4.1.2 Squelch 4.1.3 Selection 4.1.4 RF Signal level/deviation/ battery condition Display 4.1.5 T ext/frequency/battery condition Entry of brief texts 4.1.6 System configurations and specifications 4.1.7 Remote monitoring 4.1.8 Of transmitter battery Monitoring of audio signals 4.1 ...

  • Sennheiser FT-906B20 - page 18

    OPERA TING ELEMENTS ON THE EM 1046 RX MODULE RACK CONNECTOR (invisible) 8 DIGIT ALPHANUMERIC LED DISPLAY KEYS TO CONTROL THE MENU AND TO PROGRAM THE MODULE INDICATOR FOR REMOTE MONITORING MONITOR KEY STAND-BY APPROVAL NUMBER DIVERSITY CHANNELS LED BARGRAPH DISPLAYS FOR DEVIATION/RF SIGNAL LEVEL/ BATTERY CONDITION ...

  • Sennheiser FT-906B20 - page 19

    MANIPULA TION FUNCTION DISPLA Y (RX) 19 EM 203, Publ. 10/94 engl Adjustment 4.1.1 Y N SET ESC MENU AB DIVERSITY Depress an arbitrary menu key on the EM 1046 RX receiver module: Y N SET ESC The receiver switches to the menu mode. It is now ready for data entry. Receiver operation remains unaffected. The receiver is not set to the new parameters unle ...

  • Sennheiser FT-906B20 - page 20

    MANIPULA TION FUNCTION DISPLA Y (RX) 20 EM 203, Publ. 10/94 engl Receiver frequencies 4.1.2 Y N SET ESC MENU AB DIVERSITY SET 24 MHz maximal 24 MHz maximal 24 MHz maximal Chose option "RX-Freq." ( chapter 4.1.1 ). Depress to allow the receiver frequencies to be selected. The "M" on the display starts blinking. The EM 1046 RX rec ...

  • Sennheiser FT-906B20 - page 21

    MANIPULA TION FUNCTION DISPLA Y (RX) 21 EM 203, Publ. 10/94 engl Use keys to select a receiver frequency as per pre-programmed parameters. • Keeping the key depressed acdelerates selection. Depress to store new frequency. Y N • Freely selectable receiver frequencies can easily be adjusted in a 5 kHz grid. The unit changes automatically from one ...

  • Sennheiser FT-906B20 - page 22

    MANIPULA TION FUNCTION DISPLA Y (RX) 22 EM 203, Publ. 10/94 engl Depress to store data or depress or to stop storage. Y Y = YES ! The new frequency is stored in the memory. The EM 1046 RX receiver module switches to the new frequency selected. For a short time the display indicates The program returns to the selection mode. Additional frequencies c ...

  • Sennheiser FT-906B20 - page 23

    MANIPULA TION FUNCTION DISPLA Y (RX) 23 EM 203, Publ. 10/94 engl Squelch 4.1.3 Choose option „Squelch“ (see ch. 4.1.1 ) Depress to allow the squelch threshold to be set. Use keys to select the squelch threshold. • Keeping the key depressed accelerates adjustment. Depress and subsequently: to store the squelch threshold or depress or: to stop ...

  • Sennheiser FT-906B20 - page 24

    MANIPULA TION FUNCTION DISPLA Y (RX) 24 EM 203, Publ. 10/94 engl Selection 4.1.4 RF signal level/deviation/batery condition SET Y N It is useful to have permanent settings to facilitate day-to-day applications. The LED bargraph displays on the EM 1046 RX receiver module can be set to four different modes: DEVIATION/FIELD STRENGTH OF THE ACTIVE CHAN ...

  • Sennheiser FT-906B20 - page 25

    MANIPULA TION FUNCTION DISPLA Y (RX) 25 EM 203, Publ. 10/94 engl Use or to select the parameters to be indicated. Depress and subsequently to store the latest setting or depress to stop storage. DEVIATION/FIIELD STRENGTH to be indicated: The left-hand bargraph display indicates DEV (= Deviation) in % The right-hand bargraph display shows the field ...

  • Sennheiser FT-906B20 - page 26

    MANIPULA TION FUNCTION DISPLA Y (RX) 26 EM 203, Publ. 10/94 engl Use or to select the parameters to be indicated. Depress and subsequently to store the latest setting or depress to stop storage. Y = YES ! Y SET N = NO ! N CONTINUED FROM PAGE 25, CH. 4.1.4 SET ESC MENU AB DIVERSITY Y N RFA RFB µ V 1000 100 RF µ V 1000 100 RF FIELD STRENGTH OF CHAN ...

  • Sennheiser FT-906B20 - page 27

    MANIPULA TION FUNCTION DISPLA Y (RX) 27 EM 203, Publ. 10/94 engl Y N SET N = NO ! N CONTINUED FROM PAGE 26, CH. 4.1.4 SET ESC MENU AB DIVERSITY Y N DEV A DEV B DEVIATION CHANNELS A/B (DIVERSITY) to be indicated: The left-hand bargraph display indicates DEV (= deviation) in % for diversity channel A. The right-hand bargraph display shows the DEV (= ...

  • Sennheiser FT-906B20 - page 28

    MANIPULA TION FUNCTION DISPLA Y (RX) 28 EM 203, Publ. 10/94 engl Use or to select the parameters to be indicated. Depress and subsequently to store the latest setting or depress to stop storage. Y N Y = YES ! Y SET N = NO ! N CONTINUED FROM PAGE 27, CH. 4.1.4 SET ESC MENU AB DIVERSITY Y N µ V 1000 100 RF 150 100 DEV % After having depressed and NO ...

  • Sennheiser FT-906B20 - page 29

    MANIPULA TION FUNCTION DISPLA Y (RX) 29 EM 203, Publ. 10/94 engl Y N SET ESC MENU AB DIVERSITY Choose option "DispConf" (see ch. 4.1.1 ). Depress to allow the display to be set. Use to select the parameters to be indicated. Depress and subsequently to store the latest setting or depress key to stop storage. Display 4.1.5 T ext/frequency/b ...

  • Sennheiser FT-906B20 - page 30

    MANIPULA TION FUNCTION DISPLA Y (RX) 30 EM 203, Publ. 10/94 engl Entry of brief texts 4.1.6 SET Y N Y N SET ESC MENU AB DIVERSITY The display indicates the latest text entered. Thefirst segment of the eight alphanumeric segments starts blinking. NOT A BENE • If you don't want to use all segments: When "scrolling" the character set, ...

  • Sennheiser FT-906B20 - page 31

    MANIPULA TION FUNCTION DISPLA Y (RX) 31 EM 203, Publ. 10/94 engl System configurations 4.1.7 and identification data Y N SET ESC MENU AB DIVERSITY The receiver specifications are stored in every single module: The display indicates the MODEL/SERIES • EM 1046-U-L UHF ( 450 - 790 MHz) • EM 1046-U-H UHF ( 630 - 960 MHz) SERIAL NUMBER OF THE MODULE ...

  • Sennheiser FT-906B20 - page 32

    MANIPULA TION FUNCTION DISPLA Y (RX) 32 EM 203, Publ. 10/94 engl Remote monitoring of 4.1.7 transmitter battery Y N SET ESC MENU AB DIVERSITY Choose the option to indicate the condition of the transmitter battery (see ch. 4.1.1 ). Depress to select the display mode for the indication of the battery condition. NOT A BENE This function is only operat ...

  • Sennheiser FT-906B20 - page 33

    MANIPULA TION FUNCTION DISPLA Y (RX) 33 EM 203, Publ. 10/94 engl CONTINTUED FROM PAGE 32, CH. 4.1.8 CAPACITY OF RECHARGEABLE BATTERIES: Capacity of 100 % Capacity of about 80 % Capacity of about 60 % Capacity of about 40 % Capacity of about 20 %, the display starts blinking. Attention ! Replace the battery pack. The remaining capacity only suffices ...

  • Sennheiser FT-906B20 - page 34

    MANIPULA TION FUNCTION DISPLA Y (RX) 34 EM 203, Publ. 10/94 engl Monitoring of audio signals 4.1.8 It is only possible to monitor the active channel, i. e. one channel at a time. The LED on the monitor key lights up if the key is depressed, i. e. monitoring is possible. Depress to monitor the audio signal via headphones connected to the mainframe. ...

  • Sennheiser FT-906B20 - page 35

    MANIPULA TION FUNCTION DISPLA Y (RX) 35 EM 203, Publ. 10/94 engl Stand-by 4.1.9 Y N Y N SET ESC MENU AB DIVERSITY Y N In some situations it is useful not only to mute the audio signal at the mixing console but also to switch off the complete RF section of the EM 1046 receiver module. Two reasons of several possible are: • the wish to have only ac ...

  • Sennheiser FT-906B20 - page 36

    Monitor 4.2 LED indicators 4.2.1 Monitor headphones 4.2.2 OPERA TING ELEMENTS MONITORING VOLUME 20 dB GAIN FOR MONITORING ON/OFF SWITCH POWER INDICATORS BOOSTER INDICATORS (INCL. OVERLOAD) REMOTE SWITCH (REMOTE CONTROL) WITHOUT FUNCTION! MONITOR HEADPHONES (STEREO, 6,3 mm Ø MIN. IMPED. 50 Ω ) ...

  • Sennheiser FT-906B20 - page 37

    MANIPULA TION FUNCTION DISPLA Y (RX) 37 EM 203, Publ. 10/94 engl LED indicators 4.2.1 REMOTE + 20 dB + 20 dBu + 12 V - 12 V + 5 V DC - A DC - B OL - A OL- B POWER LED DISPLA Y The three upper LEDs light up if the in-built power supply unit operates perfectly + 12 V supply voltage = 12 V - 12 V supply voltage = -12 V + 5 V supply voltage = 5 V If on ...

  • Sennheiser FT-906B20 - page 38

    MANIPULA TION FUNCTION DISPLA Y (RX) 38 EM 203, Publ. 10/94 engl Monitor headphones 4.2.2 REMOTE + 20 dB + 20 dBu + 12 V - 12 V + 5 V DC - A DC - B OL - A OL- B POWER The monitor socket is suited to connect mono or stereo headphones with an impedance of about 50 to 300 Ω . The rotary switch serves to adjust the volume. The " + 20 dB " s ...

  • Sennheiser FT-906B20 - page 39

    T echnical data 5 Frequency range 450 - 790 MHz with RX module item no. 03246 760 - 960 MHz with RX module item no. 03247 Bandwidth 24 MHz Channel spacing, min. 300 kHz Channel grid, min. 5 kHz 1st oscillator frequency (1st LO) 71 MHz below / above Fe 1st intermediate frequency (1st IF) 71 MHz 2nd oscillator frequency (2nd LO) 81.7 MHz 2nd intermed ...

  • Sennheiser FT-906B20 - page 40

    SENNHEISER ELECTRONIC KG 30900 Wedemark Subject to alterations. Errors and omissions excepted! Publ.: 10/94 51104 ...

Produzent Sennheiser Kategorie Satellite Radio

Dokumente, die wir vom Produzenten des Geräts Sennheiser FT-906B20 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sennheiser
- Bedienungsanleitungen FT-906B20
- Produktkarten Sennheiser
- Informationsbroschüren
- oder Energieetiketten Sennheiser FT-906B20
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sennheiser FT-906B20.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sennheiser FT-906B20, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sennheiser FT-906B20. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sennheiser FT-906B20 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Sennheiser FT-906B20, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sennheiser FT-906B20 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sennheiser FT-906B20 verständlich ist.

Eine gänzliche Bedienungsanleitung von Sennheiser sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sennheiser FT-906B20 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sennheiser FT-906B20 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sennheiser FT-906B20, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sennheiser FT-906B20 - die uns die ersten Schritte während der Nutzung von Sennheiser FT-906B20 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sennheiser FT-906B20 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sennheiser FT-906B20 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sennheiser FT-906B20?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sennheiser FT-906B20 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sennheiser FT-906B20 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen