    2200 RA TED W A TTS/2400 MAX W A TTS PORT ABLE GENERA T OR 98452 OPERA TING INSTRUCTIONS Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright © 2009 by Harbor Freight T ools ® . All rights reserved. No portion of this manual o ...

  • Chicago Electric 98452 - page 2

    Page 2 SKU 98452 For technical questions, please call 1-800-444-3353. SPECIFICA TIONS V AC Electrical Specications 1 15 V olts @ 20 Amps Current Output 60 Hz 2200 Rated W atts / 2400 Max Watts T wo 120V , Household Receptacles with a 20 Amp circuit breaker VDC Electrical Specications 12 VDC @ 10 Amps Current Output V oltmeter Equipped 0-150 V ...

  • Chicago Electric 98452 - page 3

    Page 3 SKU 98452 For technical questions, please call 1-800-444-3353. UNP ACKING Whe n unp ack ing, che ck to make sur e all the parts show n on the Part s LIs ts on pages 20 and 22 are included. If any parts are missing or broken, please call Harbor Freight T ools at the number shown on the cover of the manual as soon as possible. GENERAL SAFETY R ...

  • Chicago Electric 98452 - page 4

    Page 4 SKU 98452 For technical questions, please call 1-800-444-3353. Do not abuse the Power Cords. Never use a Power Cord to carry tools or pull 8. the Plug from the outlet. Keep Power Cords away from heat, oil, sharp edges, or moving parts. Replace damaged Power Cords immediately . Da ma ge d Po wer Cords increase the risk of electric Shock. When ...

  • Chicago Electric 98452 - page 5

    Page 5 SKU 98452 For technical questions, please call 1-800-444-3353. the generator . Such preventive safety measures reduce the risk of starting the generator accidentally . Store idle generators out of reach of children and other untrained persons. 19. Generators are dangerous in the hands of untrained users. Maintain generators with care. 20. Do ...

  • Chicago Electric 98452 - page 6

    Page 6 SKU 98452 For technical questions, please call 1-800-444-3353. Maintain labels and nameplates on the Generator and Engine. 25. These carry important information. If unreadable, or missing, contact Harbor Freight T ools for a replacement. Generator service must be performed only by qualied repair personnel. 26. Service or maintenance perfo ...

  • Chicago Electric 98452 - page 7

    Page 7 SKU 98452 For technical questions, please call 1-800-444-3353. SPECIFIC SAFETY RULES AND PRECAUTIONS HEART P ACEMAKER PRECAUTION W ARNING! People with pacemakers should consult their physician(s ) before using this product. Electromagnetic elds in close proximity to a heart pacemaker could cause interference to or failure of the pacemaker ...

  • Chicago Electric 98452 - page 8

    Page 8 SKU 98452 For technical questions, please call 1-800-444-3353. Install sound and weather proong only when it is not raining or snowing to 1 1. avoid trapping moisture with the Generator ’ s area. FIRE AND EXPLOSION PRECAUTIONS Gasoline fuel and fumes are ammable, and potentially explosive. 1. Us e proper fuel storage and handling pro ...

  • Chicago Electric 98452 - page 9

    Page 9 SKU 98452 For technical questions, please call 1-800-444-3353. MECHANICAL PRECAUTIONS AL W A YS 1. make sure the Power Switch is in its “OFF” position. Disconnect the spark plug wire, and allow the Engine to completely cool before carrying our maintenance. Check for damaged parts. 2. Before using the Generator , any part that appears dam ...

  • Chicago Electric 98452 - page 10

    Page 10 SKU 98452 For technical questions, please call 1-800-444-3353. NOISE PRECAUTION Prolonged exposure to noise levels above 85 dBA is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the Generator when it is running. ELECTRICAL PRECAUTIONS All connections and conduits from the Generator to the loa ...

  • Chicago Electric 98452 - page 11

    Page 1 1 SKU 98452 For technical questions, please call 1-800-444-3353. Keep all electrical equipment clean and dry . 8. Replace any wiring where the in- sulation is cracked, cut, abraded, or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight. Insulate all connections and disconnected wires. ...

  • Chicago Electric 98452 - page 12

    Page 12 SKU 98452 For technical questions, please call 1-800-444-3353. GENERA TOR SUPPORT AND MOUNTING Mount the Generator on a concrete slab capable of supporting the weight of the Gen- erator . The slab must extend on all sides beyond the Frame (41B) by a least one foot. Contact a cement contractor for slab specications if necessary . Attach t ...

  • Chicago Electric 98452 - page 13

    Page 13 SKU 98452 For technical questions, please call 1-800-444-3353. AC Applications Before connecting an appliance or power cord to the generator: Make sure that it 1. is in good working order . Faulty appliances or power cords can create a potential for electrical shock. If an appliance begins to operate abnormally , becomes sluggish or stops s ...

  • Chicago Electric 98452 - page 14

    Page 14 SKU 98452 For technical questions, please call 1-800-444-3353. REV 09h THIS GENERA TOR HAS AN AUT O- SHUTDOWN OIL SENSOR. IF ENGINE STOPS OR WILL NOT ST ART , CHECK OIL LEVEL. ...

  • Chicago Electric 98452 - page 15

    Page 15 SKU 98452 For technical questions, please call 1-800-444-3353. Before the rst use, remove the Fuel T ank Cap (33B 3. 1 ) and ll the Fuel T ank (30B 1 ) with unleaded gasoline. Then, replace the Fuel T ank Cap. If necessary , rell the Fuel T ank with unleaded gasoline. (See Figure C.) T o Start The Engine: Make sure the electrical p ...

  • Chicago Electric 98452 - page 16

    Page 16 SKU 98452 For technical questions, please call 1-800-444-3353. T urn the Engine Power Switch (2) to its “ON” position. 5. (See Figure F .) Hold the Start Handle (41A) loosely and pull it slowing several times to allow the 6. gasoline to ow into the Engine’s carburetor . Then hold the Start Handle rmly and pull the rope hard and ...

  • Chicago Electric 98452 - page 17

    Page 17 SKU 98452 For technical questions, please call 1-800-444-3353. Powering 120 V olt AC T ools and Equipment: Prior to powering tools and equipment, make sure the Generator ’ s rated voltage, 1. and amperage capacity (1 15 V AC / 20 AMPs) is adequate to supply all electrical loads that the unit will power . If powering exceeds the Generator ...

  • Chicago Electric 98452 - page 18

    Page 18 SKU 98452 For technical questions, please call 1-800-444-3353. When nished using the Generator , turn the Engine Power Switch (2) to its 5. “OFF” position. T urn the Fuel V alve (40B) to its “OFF” position. Then, disconnect the electrical powered tool or equipment from the Generator ’s DC T erminals (7). (See Figure H.) After t ...

  • Chicago Electric 98452 - page 19

    Page 19 SKU 98452 For technical questions, please call 1-800-444-3353. REV 09a INSPECTION, MAINTENANCE, AND CLEANING CAUTION! Always make sure the Engine Power Switch (2) is in its “OFF” position. 1. Disconnect the spark plug wire from the engine and allow sufcient time for the Engine and Generator to completely cool before performing any in ...

  • Chicago Electric 98452 - page 20

    Page 20 SKU 98452 For technical questions, please call 1-800-444-3353. P ARTS LIST Part Description Qty 1 Bolt (M6 x 12) w/Lock W asher 9 2 Engine Power Switch 1 3B Control Panel 1 4 V oltmeter 1 5 Circuit Breaker 1 6 Outlet 2 7 DC T erminal 2 8 Ground Connector 1 9 DC Fuse 1 10 Pilot Light 1 11 Shock Absorber 4 12 Shock Absorber Foot 4 13 Lock W a ...

  • Chicago Electric 98452 - page 21

    Page 21 SKU 98452 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM ...

  • Chicago Electric 98452 - page 22

    Page 22 SKU 98452 For technical questions, please call 1-800-444-3353. P ARTS LIST - CONTINUED Part Description Qty 1A Mufer 1 2A Cylinder Head Bolt 4 3A Cylinder Head Cover Bolt 4 4A Cylinder Head Cover 1 5A Lock Nut 2 6A Adjusting Screw 2 7A Rocker Arm 3 8A Rocker Arm Bolt 2 9A V alve Push Rod Guiding Board 1 10A V alve Push Rod 2 1 1A Cylinde ...

  • Chicago Electric 98452 - page 23

    Page 23 SKU 98452 For technical questions, please call 1-800-444-3353. ASSEMBL Y DIAGRAM NOTE: Some parts are listed and shown for illustration purposes only , and are not available individually as replacement parts. ...

  • Chicago Electric 98452 - page 24

    Page 24 SKU 98452 For technical questions, please call 1-800-444-3353. California and United States Emission Control Defects W arranty Statement The California Air Resources Board (herein CARB), the United States Environmental Protection Agency (herein EP A), and Harbor Freight T ools ® (herein HFT) are pleased to explain the emission control syst ...

  • Chicago Electric 98452 - page 25

    Page 25 SKU 98452 For technical questions, please call 1-800-444-3353. 1. Length of Coverage HFT warrants to a rst retail purchaser and each sub - sequent purchaser that the engine is free from defects in materials and workmanship that cause the failure of warranted parts for a period of two (2) years after the date of delivery to the rst ret ...

Produzent Chicago Electric Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts Chicago Electric 98452 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Chicago Electric
- Bedienungsanleitungen 98452
- Produktkarten Chicago Electric
- Informationsbroschüren
- oder Energieetiketten Chicago Electric 98452
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Chicago Electric 98452.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Chicago Electric 98452, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Chicago Electric 98452. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Chicago Electric 98452 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Chicago Electric 98452, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Chicago Electric 98452 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Chicago Electric 98452 verständlich ist.

Eine gänzliche Bedienungsanleitung von Chicago Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Chicago Electric 98452 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Chicago Electric 98452 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Chicago Electric 98452, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Chicago Electric 98452 - die uns die ersten Schritte während der Nutzung von Chicago Electric 98452 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Chicago Electric 98452 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Chicago Electric 98452 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Chicago Electric 98452?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Chicago Electric 98452 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Chicago Electric 98452 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)