    Installation Instructions TP-P AC, TP-PHP TP-NAC, TP-NHP P erformance t Series AC / HP Thermostat A07049 A07048 Pr ogrammable Control Non − Pr ogrammable Contr ol Designed and Assembled in the U.S.A. NOTE : Read the entire instruction manual before starting the installation. US patents: US7287709 B2, US20080147242 A1, USD582800 SI, US20060165149 ...

  • Carrier TP-NAC - page 2

    ...

  • Carrier TP-NAC - page 3

    1 T ABLE OF CONTENTS P AGE SAFETY CONSIDERA TIONS 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INTRODUCTION 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INST ALLA TION CONSIDERA TIONS 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INST ALLA TION 6 . . . . . ...

  • Carrier TP-NAC - page 4

    2 INTRODUCTION Carrier ’ s 7 − day , 5/2 − day , 1 − day programmable and non − programmable Performance Series Thermostat Control is a wall − mounted, low − voltage temperature control in either a single unit or a two − piece unit. In two − piece configuration, the relays are located near the equipment and a two − wire connecti ...

  • Carrier TP-NAC - page 5

    3 INST ALLA TION CONSIDERA TIONS Power This control is powered by 24V AC only . It requires 24V AC (Rh and/or Rc and C terminals) of the low − voltage transformer to be connected to it for proper operation. It will not operate without these 2 connections. Rh and Rc are connected via PCB breakout jumper . See Fig. 1. For applications using two 24V ...

  • Carrier TP-NAC - page 6

    4 A07052 Fig. 1 − PCB Br eakout Jumper Models There are programmable and non − programmable models for all applications. They can be configured for AC or HP installations, allowing it to be used in place of all Carrier thermostats. Programmable thermostats may be configured as non − programmable if user desires. Outdoor T emperatur e Sensor T ...

  • Carrier TP-NAC - page 7

    5 dedicated sensor wires may be used for its connection. Details are provided in sensor instructions. Remote Indoor T emperatur e Sensor A remote temperature sensor may be used with the programmable heat pump and programmable air conditioner thermostats where it is desirable to install the thermostat in a limited access location while measuring the ...

  • Carrier TP-NAC - page 8

    6 Wiring W ire length should be no more than 250 ft (76m). Use 22 A WG for normal wiring applications. Continuous wire lengths over 100 ft (30.5m) should use 20 A WG or larger . INST ALLA TION Carton contains the following components. See Fig. 2 for programmable models or Fig. 3 for non − programmable models. A07754 Fig. 2 − TP − P AC / TP ? ...

  • Carrier TP-NAC - page 9

    7 A07755 Fig. 3 − TP − NAC / TP − NHP Carton Contents 1. Display Module 2. Stand − of f for Equipment Control Module 3. Screws and pig tail 4. Equipment Control Module AC/HP Control Location AC/HP Control should be mounted:  Approximately 5 ft (1.5m) from floor .  Close to or in a frequently used room, preferably on an inside parti- t ...

  • Carrier TP-NAC - page 10

    8 AC/HP Control should NOT be mounted:  Close to a window , on an outside wall, or next to a door leading to the outside.  Exposed to direct light or heat from a lamp, sun, fireplace, or other temperature − radiating objects which could cause a false reading.  Close to or in direct airflow from supply registers and return − air regis- ...

  • Carrier TP-NAC - page 11

    9 UNIT DAMAGE HAZARD Failure to follow this caution may result in equipment damage or improper operation. Improper wiring or installation may damage AC/HP Control. Check to make sure wiring is correct before proceeding with installation or turning on power. CAUTION ! 1. Turn of f all power to equipment. 2. If an existing thermostat is being replace ...

  • Carrier TP-NAC - page 12

    10 Tw o − Piece Installation The following steps should be followed for the installation of the two − piece configuration. NOTE : The 2 − wire pigtail is not intended to support the weight of the User Interface. Do not hang the User Interface from the equipment Control Module screw terminals. 1. Remove mounting plate from back of Display Modu ...

  • Carrier TP-NAC - page 13

    11 A07226 Fig. 5 − T ake Apart 2. Route wires through lar ge hole in mounting base. Level mounting base against wall (for aesthetic value only—Display Module need not be lev- eled for proper operation) and mark wall through 4 mounting holes. T o avoid unintended bending of wall plate plastic, use all 4 screws and an- chors. See Fig. 6. ...

  • Carrier TP-NAC - page 14

    12 A07165 Fig. 6 − Backplate Mounting 3. Drill two 3/16 − in. mounting holes in wall where marked. Thermostat may be mounted to a standard junction box, if desired. Hole pattern on ther- mostat mounting base matches junction box mounting holes. 4. Secure rear plastic mounting base to wall with 4 screws and anchors pro- vided. T o avoid unintend ...

  • Carrier TP-NAC - page 15

    13 Relays OAT RRS SRTN HUM D1 D2 V+ Vg Rc Rh W / W1 G Y/Y2 Y used for single stage cooling C O/W2/B Y1 Y1 used for multi-speed cooling Y1 = stage 1 Y2 = stage 2 Control Module Wiring Guide connect to user interface dry contact OAT / RRS return { Relays OAT RRS SRTN HUM D1 D2 V+ Vg Rc Rh W / W1 G Y/Y2 Y used for single stage cooling C O/W2/B Y1 Y1 u ...

  • Carrier TP-NAC - page 16

    14 A07166 Fig. 8 − Secur e W ir es to T erminal Strip A07167 Fig. 9 − Connect Pigtail W ir es to Display Module ...

  • Carrier TP-NAC - page 17

    15 NOTE : The 2 − wire pigtail is not intended to support the weight of the User Interface. Do not hang the User Interface from the equipment Control Module screw terminals.  Red is V+  Black is Vg 7. Push any excess wire into wall and against mounting base. Seal hole in wall to prevent air leaks. Leaks can affect operation and cause incorr ...

  • Carrier TP-NAC - page 18

    16 10. Find suitable indoor mounting location for Equipment Control Module, either near or on equipment. See Fig. 11. IMPOR T ANT NOTE: Equipment Control Module should not be mounted to duct work or below any other contr ols or equipment (i.e. humidistat, humidifier , etc.) A07217 Fig. 1 1 − Equipment Control Module on Equipment 11. Route wires t ...

  • Carrier TP-NAC - page 19

    17 A07227 Fig. 12 − Standoff NOTE : Standof fs are provided as an aid when installing Equipment Control Module on inside equipment or a solid wall. 12. Match and connect equipment wires to proper terminals of each connector block being careful not to over tighten the screws. Correct polarity must be observed when connecting the two wires from the ...

  • Carrier TP-NAC - page 20

    18 A07218 Fig. 13 − Cover on Equipment Control Module 14. T urn on power to equipment. On power up, all display segments will light for 5 sec. For the next 5 sec a 2 − digit code appears on lar ge display which identifies AC/HP Control configuration. Refer to Option 33. a. AC — 1 − stage air conditioner , AC, with furnace or fan coil b. HP ...

  • Carrier TP-NAC - page 21

    19 Single − Piece Installation The following steps should be followed for the installation of the single − piece configuration. 1. Remove cover from Equipment Control Module by pressing the two tabs on the bottom edge and pulling away . Route wires through lar ge hole in Equipment Control Module. Level Equipment Control Module against wall (for ...

  • Carrier TP-NAC - page 22

    20 A07219 Fig. 14 − Equipment Control Module 5. Match and connect equipment wires to proper terminals of each connector block. 6. Push any excess wire into wall and against Equipment Control Module. Seal hole in wall to prevent air leaks. Leaks can affect operation and cause incorrect temperature measurement. 7. Remove 2 − wire pigtail from the ...

  • Carrier TP-NAC - page 23

    21 A07220 Fig. 15 − Reattach Display Module 9. T urn on power to equipment. On power up, all display segments will light for 5 sec. For the next 5 sec a 2 − digit code appears on lar ge display which identifies AC/HP Control configuration. Refer to Option 33. a. AC — 1 − stage air conditioner , AC, with furnace or fan coil b. HP — 1 − s ...

  • Carrier TP-NAC - page 24

    22 must be properly set by the installer . (Only those marked with an asterisk * below are available to the homeowner .) The homeowner configurations are described in the owner’ s manual. A special procedure allows entry into the configuration mode. Description of each selection and how to use the configuration mode follows. CONFIGURA TION OPTION ...

  • Carrier TP-NAC - page 25

    23 Option 18* — Backlight Configuration Option 19 — Dry Contact (programmable models only) Option 20 — Outdoor Air T emperature Offset Adjustment Option 21* — Keypad Lockout Option 24* — Programmable/Non − Programmable (programmable models only) Option 25* — Number of Programmable Periods per Day (programmable models only) Option 26 ? ...

  • Carrier TP-NAC - page 26

    24 WHILE IN CONFIGURA TION MODE The option number is displayed in the heat setpoint location and the configuration setting is displayed in the cool setpoint location. On the TP − P AC/PHP (programmable) models, a box will surround the option number . The mode button is used to move the box between the two displayed values. The soft keys below the ...

  • Carrier TP-NAC - page 27

    25 Defaults HP model defaults to HP . AC model defaults to AC. Option 02 — Clean Filter T imer Select hours of blower operation (heating, cooling, or fan) before CHECK FIL TER icon is displayed. With OF selected, icon will never come on, disabling this feature. Time selection can range from 800 to 7200 hr by selecting numbers 1 through 9. (Time i ...

  • Carrier TP-NAC - page 28

    26 Sensor 1 Sensor 2 Sensor 3 Sensor 4 RRS SRTN A09130 Fig. 16 − Remote Room Sensor − Parallel W iring This selection determines which sensor the control will use for measuring room air temperature. Room air temperature can be sensed in one of three ways; the local sensor (L) located on the Display Module, the remote room air sensor (r), or the ...

  • Carrier TP-NAC - page 29

    27 Option 07 — Zoning This selection should be set to On when the thermostat is to be used as part of a zoning system. It is assumed that the zoning equipment will take care of time guard and cycle timers. The minimum on time is still controlled by the thermostat. Default is OF (off). Option 08 — Auxiliary Heat Lockout T emperatur e This select ...

  • Carrier TP-NAC - page 30

    28 C — Reversing valve output (O/W2/B) is energized when COOL mode is selected. Default is C. Option 1 1 — Deadband Setting Between Heat & Cool This option is not available on Heat Only and Cool Only systems. This selection is to allow the installer to choose how much differential exists between the heating and cooling setpoints. Allowable ...

  • Carrier TP-NAC - page 31

    29 On — Auto mode is available. OF — Auto mode is not available. Default is On. Option 16 — Maximum Cycles Per Hour This selection limits the number of cycles per hour that the thermostat allows the system to operate. Selections are 2, 4, 6. 2 — The heating and cooling outputs will be energized no more than 2 times per hour . When an output ...

  • Carrier TP-NAC - page 32

    30 becomes brighter when a button is pressed. After 10 seconds of no button presses, the backlight will return to the dimmer level until another button press occurs. The range of brightness is 1 through 5 with 5 being full brightness. Default is 3. Option 19 — Dry Contact Configuration (pr ogrammable models only) There are 2 available selections, ...

  • Carrier TP-NAC - page 33

    31 1 — The user has access to modify setpoints, time of day . 2 — The user has access to change the setpoints only . 3 — The entire keypad is locked. When a button is pressed, the backlight will turn on but none of the operating parameters will be changed. When the keypad lock selection is turned on, the padlock icon will be displayed. T o un ...

  • Carrier TP-NAC - page 34

    32 Option 22 — High Cool Latch T emperatur e (only available if outdoor sensor is pr esent) An outdoor sensor is required for high cool latch feature. This selection is only available when Option 1 is set to H2, A2, or h2 and when Option 7 (zoning) is set to OF (off). Configuration settings are OF (of f), 80, 85, 90, 95, 100, 105, 110, On. OF (of ...

  • Carrier TP-NAC - page 35

    33 When a cycle starts under a high heat latch, it will finish the heating cycle on high stage. On — The Y1 and Y/Y2 outputs are simultaneously energized to satisfy all heating demands. Default is OF (off). Option 24 — Pr ogrammable/Non − Pr ogrammable This selection allows the installer to configure the thermostat as either programmable or n ...

  • Carrier TP-NAC - page 36

    34 Option 27 — Maximum Heating Setpoint This selection allows the installer to configure the maximum heating setpoint. The range is based on the adjustable deadband value Option 1 1, such that the minimum of the range is 50  F/10  C and the maximum is 90  F/32  C minus the deadband. Default is 88  F/31  C (based on the adjustabl ...

  • Carrier TP-NAC - page 37

    35 “overrides” the programmed fan setting by pressing the fan button, the override selection will remain in effect until the next programmed period time. Default is OF (off). Option 31 — Daylight Savings T ime Configuration (programmable models only) This selection allows the installer to set the thermostat to automatically change by one hour ...

  • Carrier TP-NAC - page 38

    36 2 — Thermostat will control the W1 and O/W2/B outputs. Default is 1. Option 33 — Single or T wo − Piece Installation This configuration allows the thermostat to compensate for the amount of heat generated by the thermostat electronics to allow more accurate sensing of the temperature sensor . The amount of heat compensation will be differe ...

  • Carrier TP-NAC - page 39

    37 of f even if the user has the fan selection set to continuous fan. The fan output will be turned back on in this temperature range if the maximum capacity of auxiliary heat is on due to system demand (auxiliary heat on in response to a defrost signal shouldn’ t cause the fan to turn back on). If the outdoor air temperature is below 12  F/ ? ...

  • Carrier TP-NAC - page 40

    38 SYSTEM ST AR T − UP AND CHECKOUT The AC/HP Control is designed with a built − in installer test capability . It allows easy operation of equipment without delays or setpoint adjustments to force heating or cooling. T o enable installer test mode, press and hold the fan button for 15 seconds. After 10 seconds, the thermostat will enter Config ...

  • Carrier TP-NAC - page 41

    39 TO TEST F AN Fan button switches F AN icon between AUT O and On. While On is displayed, G output will be ener gized, turning fan on. On some fan coils, fan continues to operate for 90 sec after G signal is removed. Final Settings Be sure to press DONE to exit installer setup mode. If the system is to be left in operation after installation is co ...

  • Carrier TP-NAC - page 42

    40 The F AN button may be used to select between AUTO (fan on only with equipment) and On (fan on continuously) fan modes. For further information on temperature selection and programming, refer to Homeowner’ s Guide. Setting The Clock, Calendar , Daily Schedule, and V acation Settings (pr ogrammable models only) T o set the clock, press the SET ...

  • Carrier TP-NAC - page 43

    41 provides temperature protection for the home in the selected mode, but not comfort. When vacation mode is active, an arrow will be displayed beside “V ACA TION” in the upper left corner of the display . V acation Setpoints A special set of temperature setpoints exist which are active in vacation mode. They are adjustable by the homeowner, ar ...

  • Carrier TP-NAC - page 44

    42 Te n − Minute Staging Timer In multistage heating or cooling, this timer prevents any higher stage from turning on until preceding stage has been on for 10 minutes. When staging between compressor and electric heat or between compressor and furnace heat, the time is configurable. The timer is configurable via Option 17. This timer is overridde ...

  • Carrier TP-NAC - page 45

    43 Thr ee − Minute Minimum on Time In normal operation, when a stage turns on, it will not turn off for a minimum of 3 minutes. If the setpoint is changed, this timer is canceled, allowing the equipment to turn of f immediately when the demand is removed. Heat/Cool Setpoints (Desir ed T emperatur e) A minimum difference of 1  and maximum of 6 ...

  • Carrier TP-NAC - page 46

    44 Pr ogrammable Fan (programmable models only) The fan output can be programmed based on period of the day . When programming for each day and period the fan can be set to On or AUTO. If the fan button is pressed to change from On to Auto or vice versa when programmable fan has been enabled, the manual change will only remain in ef fect until the ...

  • Carrier TP-NAC - page 47

    45 T emperatur e Offset After Power Cycle T o compensate for internal heat build − up from the electronics in the thermostat, the thermostat will add an offset to the actual temperature that it measures. If the thermostat power is cycled quickly , one can witness an immediate increase in the actual temperature displayed due to this added offset. ...

  • Carrier TP-NAC - page 48

    46 E3 − If AC/HP Control cannot properly read outdoor temperature, and it is needed for proper operation, display will indicate “ −− ” in the outdoor temperature location. E4 − If AC/HP Control’ s internal memory fails, E4 will be displayed. Replace AC/HP Control. T able 3 can be used as a troubleshooting tool for determining which ou ...

  • Carrier TP-NAC - page 49

    47 T able 3 – Equipment Configuration Outputs For COOL, HEA T and Emergency Heat modes, the following chart shows the state for each output in each stage of operation EQUIP CONFIG OPTION 01 HARD- W ARE CONFIG COOL STG 1 COOL STG 2 HEA T STG 1 HEA T STG 2 HEA T STG 3 HEA T STG 4 EM HEA T STG 1 EM HEA T STG 2 SS AC AC Y/Y2 - W/W1 - - - - - SS AC HP ...

  • Carrier TP-NAC - page 50

    48 T able 3 − Equipment Configuration Outputs (cont.) EQUIP CONFIG OPTION 01 HARD- W ARE CONFIG COOL STG 1 COOL STG 2 HEA T STG 1 HEA T STG 2 HEA T STG 3 HEA T STG 4 EM HEA T STG 1 EM HEA T STG 2 2SPD HP RVS + B 2S Y1/W2 Y1/W2 Y/Y2 Y1/W2 O/W2/B Y1/W2 Y/Y2 O/W2/B Y1/W2 Y/Y2 O/W2/B W/1 - W/W1 - Heat Only Unit AC HP 2S - - W/W1 If HP or 2S board AND ...

  • Carrier TP-NAC - page 51

    49 WIRING DIAGRAMS Display module Display module wall m ount Equipment Control Module Fan Coil Heat P ump V+ V+ Vg Vg O O V+ V+ RVS/Heat Stage 2 O/B W 2 W3 W2 Vg Vg Heat Stage 1 W /W1 W2 Compressor Y/Y2 Y Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Common C COM COM Outdoor Air Temp OAT ...

  • Carrier TP-NAC - page 52

    50 WIRING DIAGRAMS(cont.) Therm ostat Fan Coil Heat Pum p OO RVS/Heat Stage 2 O/B W 2 W 3 W 2** Heat Stage 1 W /W1 W 2 Compressor Y/Y 2 Y Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Comm on C COM COM Outdoor Ai r Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Remo ...

  • Carrier TP-NAC - page 53

    51 WIRING DIAGRAMS(cont.) Therm ostat Fan Coil O RVS/Heat Stage 2 O/B W 2 W 3 Heat Stage 1 W/W 1 W 2 Compressor Y/Y 2 Not Used Y1 Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 Aux. Connection 24VAC Common C COM Outdoor A ir Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Remote Room Senso ...

  • Carrier TP-NAC - page 54

    52 WIRING DIAGRAMS(cont.) Therm ostat Fan Coil Air Conditioner O RVS/Heat Stage 2 O/B W2 W 3 Heat Stage 1 W /W 1 W 2 Compressor Y/Y 2 Y Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Common C COM COM Outdoor A ir Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Remote ...

  • Carrier TP-NAC - page 55

    53 WIRING DIAGRAMS(cont.) Therm ostat Fan Coil O RVS/Heat Stage 2 O/B W 2 W 3 Heat Stage 1 W /W1 W2 Compressor Y/Y 2 Not Used Y1 Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 Aux. Connection 24VAC Comm on C COM Outdoor Ai r Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Remote Room Senso ...

  • Carrier TP-NAC - page 56

    54 WIRING DIAGRAMS(cont.) Therm ostat Furnace Air Conditioner Heat Stage 1 W /W 1 W/W1 Compressor Y/Y 2 Y/Y2 Y Not Used Y1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Common C COM COM Outdoor Ai r Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Remote Room Sensor * * Heat Stage ...

  • Carrier TP-NAC - page 57

    55 WIRING DIAGRAMS(cont.) Therm ostat RVS/Heat Stage 2 O/B W 2 Heat Stage 1 W /W 1 Compressor Y/Y 2 Not Used Y1 Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Comm on C C Outdoor A ir Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT /RRS A09158 Fig. 23 − Thermostat with Dry Contact Control for Run Time ...

  • Carrier TP-NAC - page 58

    56 WIRING DIAGRAMS(cont.) Therm ostat Furnace Air Conditioner W2 RVS/Heat Stage 2 O/B W 2 Heat Stage 1 W /W 1 W /W1 Compressor Y/Y 2 Y/Y2 Y Not Used Y 1 Fan G G 24VAC Hot Heating Rh R R 24VAC Hot Cooling Rc Dry Contact 1 D1 Dry Contact 2 D2 24VAC Comm on C COM C OM Outdoor Ai r Temp OAT Remote Room Sensor RRS OAT/RRS Com OAT/RRS Outdoor Sensor * Re ...

  • Carrier TP-NAC - page 59

    57 WIRING DIAGRAMS(cont.) Single-Stage Single-Stage Therm ostat Furnace Air Conditioner RVS/Heat Stage 2 O/B W 2 Heat Stage 1 W /W 1 W/W1 Compressor Low Y1 Compressor High Y/Y 2 Y/Y2 Y Fan G G 24VAC Hot Heating Rh R 24VAC Hot Cooling Rc R* Dry Contact 1 D1 Dry Contact 2 D2 24VAC Comm on C COM COM Outdoor Ai r Temp OAT Remote Room Sensor RRS OAT/RRS ...

  • Carrier TP-NAC - page 60

    58 THERMOSTA T CONFIGURA TION RECORD Installer _________________________ Model Number ______________________________ Date _________________________ A. Hardware Configuration __________ Seal Hole In W all B. Mode Settings __________ Mode (Off, Heat, Cool, Auto, Em Heat) __________ Heating Setpoint Value __________ Cooling Setpoint V alue __________ ...

  • Carrier TP-NAC - page 61

    59 E Configuration Options Option 01 _____ Equipment Type Option 02 _____ Clean Filter Timer Adjustment Option 03* _____ Fahrenheit/Centigrade Selection Option 04 _____ Fan (G) on with W/W1 Selection Option 05 _____ Room Air T emperature Sensing Option 06 _____ Cooling Lockout Below 55  F/13  C Selection (only available if outdoor air sensor ...

  • Carrier TP-NAC - page 62

    60 E Configuration Options (cont) Option 21* _____ Keypad Lockout Option 22 _____ High Cool Latch T emperature Option 23 _____ High Heat Latch T emperature Option 24* _____ Programmable/Non-Programmable (programmable models only) Option 25* _____ Number of Programmable Periods Per Day (programmable models only) Option 26 _____ Minimum Cooling Setpo ...

  • Carrier TP-NAC - page 63

    ...

  • Carrier TP-NAC - page 64

    0 Copyright 2009 Carrier Corp.  7310 W . Morris St.  Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 04/09 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: TP-P AC-2SI Catalog No: TP-P AC-3SI ...

Produzent Carrier Kategorie Thermostat

Dokumente, die wir vom Produzenten des Geräts Carrier TP-NAC erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Carrier
- Bedienungsanleitungen TP-NAC
- Produktkarten Carrier
- Informationsbroschüren
- oder Energieetiketten Carrier TP-NAC
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Carrier TP-NAC.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Carrier TP-NAC, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Carrier TP-NAC. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Carrier TP-NAC ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Carrier TP-NAC, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Carrier TP-NAC hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Carrier TP-NAC verständlich ist.

Eine gänzliche Bedienungsanleitung von Carrier sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Carrier TP-NAC bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Carrier TP-NAC befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Carrier TP-NAC, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Carrier TP-NAC - die uns die ersten Schritte während der Nutzung von Carrier TP-NAC erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Carrier TP-NAC hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Carrier TP-NAC im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Carrier TP-NAC?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Carrier TP-NAC nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Carrier TP-NAC hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)