Bedienungsanleitung Design Dynamics HKE-24-RFP

20 Seiten 2.41 mb
Download

Zur Seite of 20

Summary
  • Design Dynamics HKE-24-RFP - page 1

    Sav e this manual for future reference. For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any ...

  • Design Dynamics HKE-24-RFP - page 2

    www .desatech.com 1 15481-01B 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier . W ARN ING ...

  • Design Dynamics HKE-24-RFP - page 3

    www .desatech.com 1 15481-01B 3 SAFETY INFORMA TION W ARN ING : Th is pro duc t co n- ta ins an d/o r gen era tes c he mic als kno wn t o the Sta te o f Cal ifo rni a to cause c anc er or b irt h def ect s or oth er rep rod uct ive ha rm. W ARNING: Keep flue open when operating unit. I M P O RT AN T : Re ad th is o w n e r’ s m a n u al c ar e f ...

  • Design Dynamics HKE-24-RFP - page 4

    www .desatech.com 1 15481-01B 4 Ch ild ren an d ad ul ts sh ou ld be al ert ed t o t he ha zar d of h ig h te m- pe rat ure an d sho uld st ay aw ay to av oid bu rns or cl oth ing ig nit ion . 1. This appliance, as supplied, is only for use with the type of gas indicated on the rating plate. This a ppliance i s n ot conver tible for use with other ...

  • Design Dynamics HKE-24-RFP - page 5

    www .desatech.com 1 15481-01B 5 UNP ACKING CA UTI ON: Do not re move th e data plates from the grate as- sembly . The data plates contain important warranty and safety information. 1. Remove log set assembly from carton. 2. Re mov e a ll pr ot ect ive pa ck agi ng ap pli ed to lo g se t f or shi pme nt. 3. Check all items for any shipping damage. I ...

  • Design Dynamics HKE-24-RFP - page 6

    www .desatech.com 1 15481-01B 6 PLACEMENT OF APPLIANCE Center the appliance in the fireplace. Make certain the g rate fron t feet s it inside t he front ed ge of the fireplace and that there is adequate clearance around the appliance for access and operation. CONNECTING TO GAS SUPPL Y W AR NI NG : A q u al ifi ed s er vi ce p er so n m u s t co ...

  • Design Dynamics HKE-24-RFP - page 7

    www .desatech.com 1 15481-01B 7 INST ALLA TION Continued The appliance gas inlet connection is 3/8" NPT at the regulator , located at the rear of the appliance. IMPORT ANT : Hold appliance regulator with a wrench to prevent movement when connecting to inlet piping. CAUT ION: Use only ne w , black iron or steel pipe. Inter- nally-tinned copper ...

  • Design Dynamics HKE-24-RFP - page 8

    www .desatech.com 1 15481-01B 8 INST ALLA TION Continued Figure 5 - Equipment Shutoff V alve Equipment Shutoff V alve Open Closed Figure 7 - Checking Gas Joints (Natural Gas Only) Control V alve Location Equipment Shutoff V alve Propane/LP Supply T ank Equipment Shutoff V alve Gas Meter Figure 6 - Checking Gas Joints (Propane/LP Gas Only) Control V ...

  • Design Dynamics HKE-24-RFP - page 9

    www .desatech.com 1 15481-01B 9 3. Pl ace fibe r log pi ec es ra nd oml y on la va ro ck an d em be r mate ria l ar ou nd u nit (se e Fi gu re 10) . 4. Use remaining lava rock to blend the floor media together . Y our finished effect should resemble Figure 1 1. W ARNING: Failure to posi- tion the floor media as shown in Figures 8 through 1 1 or ...

  • Design Dynamics HKE-24-RFP - page 10

    www .desatech.com 1 15481-01B 10 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: Keep flue open when operating unit. W ARNING: If you do not fol- low these instructions exactly , a fire or explosion may result causing property damage, per- sonal injury or loss of life. A. This appliance has a pilot which must be lighted with a piezo ignitor . When ...

  • Design Dynamics HKE-24-RFP - page 11

    www .desatech.com 1 15481-01B 1 1 OPERA TING HEA TER Continued 4. P r e s s M O D E b u t t o n u n t i l m o d e shows in display window of transmitter/ remote. Press up or down key to change set temperature. 5. T o set del ay ti me r , pr ess TIM ER but to n fo ll ow ed b y e it he r t he up or d ow n ke y . 6. T o c ha n g e t h e f l a me h ei ...

  • Design Dynamics HKE-24-RFP - page 12

    www .desatech.com 1 15481-01B 12 CLEANING AND MAINTENANCE W ARNING: T urn off the ap- pliance and allow to cool before cleaning. CAUTION: Y ou must keep control areas, burners and circulating air passageways of fireplace clean. In spect these areas of fireplace before each use. Have firepl ace and chimney (if applicable) inspected yearly by a qu ...

  • Design Dynamics HKE-24-RFP - page 13

    www .desatech.com 1 15481-01B 13 TROUBLESHOO TING Note: In normal operation, LED blinks once every two seconds; also, LED will be on for one second after every valid command received by the receiver/valve' these are not error codes. Failure codes can occur anytime after the pilot burner is lit. Failure code timing is 1/4 second on, 1/2 second ...

  • Design Dynamics HKE-24-RFP - page 14

    www .desatech.com 1 15481-01B 14 OBSERVED PROBLEM Pilot burning, no gas to burner, valve knob "ON", wall switch "ON" Frequent pilot/burner outage problem REMEDY 1. Check wall switch and wires for proper connections. Jump - er wire acro ss termi nal s at wall switch. If burner comes on, replace defective wall switch. If okay , ju ...

  • Design Dynamics HKE-24-RFP - page 15

    www .desatech.com 1 15481-01B 15 SPECIFICA TIONS HCA-24-RFN HCA-24-RFP HCA-18-RFN HCA-18-RFP HCM-24-RFN HCM-24-RFP HCM-18-RFN HCM-18-RFP HKE-24-RFN HKE-24-RFP HKE-18-RFN HKE-18-RFP Btu (V ariable) 45,000/67,000 43,000/65,000 41,000/56,000 42,000/51,000 T ype Gas Natural Gas Only Propane/LP Only Natural Gas Only Propane/LP Only Ignition Piezo Piezo ...

  • Design Dynamics HKE-24-RFP - page 16

    www .desatech.com 1 15481-01B 16 ILL USTRA TED P ARTS BREAKDOWN HCA-24-RFN, HCA-24-RFP , HCA-18-RFN, HCA-18-RFP , HCM-24-RFN, HCM-24-RFP , HCM-18-RFN, HCM-18-RFP , HKE-24-RFN, HKE-24-RFP , HKE-18-RFN, HKE-18-RFP 1 3 7 6 5 4 2 8 9 10 12 13 17 15 16 1 1 ...

  • Design Dynamics HKE-24-RFP - page 17

    www .desatech.com 1 15481-01B 17 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual. P ART NUMBER HCA-24-RFN HCA-24-RFP HCA-18-RFN HCA-18-RFP KEY HCM-24-RFN HCM-24-RFP HCM-18-RFN HCM-18-RFP NO. HKE-24-RFN HKE-24-RFP HKE-18-RFN H ...

  • Design Dynamics HKE-24-RFP - page 18

    www .desatech.com 1 15481-01B 18 ACCESSORIES Purchase these appliances from your local dealer . If they can not supply thes e acce ssor ies, call DESA at 1-866-672-6040 for referral informatioin. Y ou can also write to the address listed on the back page of this manual. EQUIPMENT SHUTOFF V AL VE GA5010 Equipment shutoff valve with 1/8" NPT tap ...

  • Design Dynamics HKE-24-RFP - page 19

    www .desatech.com 1 15481-01B 19 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________ ...

  • Design Dynamics HKE-24-RFP - page 20

    LIMITED WARRANTY VENT -FREE FIREBO X DESA warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. T o make a claim under this warranty the Bill of Sale ...

Produzent Design Dynamics Kategorie Log Splitter

Dokumente, die wir vom Produzenten des Geräts Design Dynamics HKE-24-RFP erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Design Dynamics
- Bedienungsanleitungen HKE-24-RFP
- Produktkarten Design Dynamics
- Informationsbroschüren
- oder Energieetiketten Design Dynamics HKE-24-RFP
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Design Dynamics HKE-24-RFP.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Design Dynamics HKE-24-RFP, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Design Dynamics HKE-24-RFP. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Design Dynamics HKE-24-RFP ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Design Dynamics HKE-24-RFP, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Design Dynamics HKE-24-RFP hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Design Dynamics HKE-24-RFP verständlich ist.

Eine gänzliche Bedienungsanleitung von Design Dynamics sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Design Dynamics HKE-24-RFP bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Design Dynamics HKE-24-RFP befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Design Dynamics HKE-24-RFP, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Design Dynamics HKE-24-RFP - die uns die ersten Schritte während der Nutzung von Design Dynamics HKE-24-RFP erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Design Dynamics HKE-24-RFP hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Design Dynamics HKE-24-RFP im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Design Dynamics HKE-24-RFP?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Design Dynamics HKE-24-RFP nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Design Dynamics HKE-24-RFP hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)