Bedienungsanleitung Belshaw Brothers 718LCG

42 Seiten 0.4 mb
Download

Zur Seite of 42

Summary
  • Belshaw Brothers 718LCG - page 1

    Gas Fryer Models 718LCG, 724CG, and 734CG Operator’s Manual Serial # W 06060001 - on If you accept the machine from the shipping company, you are, in effect, saying that the machine is in good condition, and you must pay for the machine. Belshaw cannot pay for shipping damage, because the freight company has accepted the machine from Belshaw in g ...

  • Belshaw Brothers 718LCG - page 2

    EQUIPMENT RECORD Please provide the information below when you correspond with us about your machine. Purchased by _____________________________________________________________________ Installed by ______________________________________________________________________ Date of Installation ____________________________________________________________ ...

  • Belshaw Brothers 718LCG - page 3

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN iii Contents Sections 1 Installation 1 Conforming to Codes 1 Selecting a Workstation 1 Unpacking the Fryer 2 Initial Cleaning 2 Assembling the Fryer 2 Installing the Fryer 3 Moving the Fryer 4 2 ...

  • Belshaw Brothers 718LCG - page 4

    B Donut-Making Helps B-1 Tips on Making Quality Cake Donuts B-1 Calculating Correct Water Temperature B-2 Ratios of Plunger Sizes to Donut Weights B-2 Temperature Conversion B-2 C Parts Lists C-1 Limited Warranty Insert ...

  • Belshaw Brothers 718LCG - page 5

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN v Preface The 718LCG, 724CG, and 734CG Gas Fryers are designed to fry cake and yeast-raised donut products. Each must be bolted to a flat, dry floor. The operator should stand opposite the flue s ...

  • Belshaw Brothers 718LCG - page 6

    Contact Belshaw Brothers at 1-800-578- 2547 to obtain necessary parts and instructions. ...

  • Belshaw Brothers 718LCG - page 7

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 1 1 Installation In a prominent location, post instructions to be followed in the event the user smells gas. Obtain this information by consulting your local gas supplier. FOR YOUR SAFETY Do not ...

  • Belshaw Brothers 718LCG - page 8

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers The workstation should allow at least 2”/5 cm clearance between the machine and all construction, whether combustible or noncombustible. In addition, it should allow access to the rear of the ...

  • Belshaw Brothers 718LCG - page 9

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 3 3. Put the heat shield and splash shield on the fryer. They slide over the flue stack, and the back of the kettle slides between the heat shield and the splash shield. The mounting holes in the ...

  • Belshaw Brothers 718LCG - page 10

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers gas supply line on the fryer itself is 1/2”/1.3 cm I.P.S.) b. Connect the fryer to the building’s gas supply. c. Seal all threaded joints between gas pipes with pipe joint compound. You mus ...

  • Belshaw Brothers 718LCG - page 11

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 5 Operation 2 Taking Safety Precautions In a prominent location, post information about what to do if there is a gas leak. Make sure that all employees know what to do. WARNING To avoid the possi ...

  • Belshaw Brothers 718LCG - page 12

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 4. Move the on/off switch to the OFF position. 5. Rotate the gas control knob counterclock- wise to the ON position. 6. Move the on/off switch to the ON position. The yellow pilot light near th ...

  • Belshaw Brothers 718LCG - page 13

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 7 CAUTION To avoid damaging the machine, do not operate the conveyor until all the shortening has melted. 11. Continue supplying shortening to the kettle as required. Keep the kettle filled up to ...

  • Belshaw Brothers 718LCG - page 14

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 8 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 3 Cleaning For your safety, observe the following warnings throughout the entire cleaning process. WARNING Thoroughly clean and dry the floor if shortening, water, or other materials are spille ...

  • Belshaw Brothers 718LCG - page 15

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 9 WARNING Do not allow the shortening to overflow the containers. Shortening will get on the floor, and if the shortening is not cool enough, you may be burned. WARNING Thoroughly clean and dry t ...

  • Belshaw Brothers 718LCG - page 16

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 10 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers WARNING Do not allow the cleaning solution to overflow the containers. Cleaning solution will get on the floor, and if the solution is not cool enough, you may be burned. 8. When the draining ...

  • Belshaw Brothers 718LCG - page 17

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 11 Maintenance 4 SB-0308 rev 3 AFFECTS: OPEN KETTLE FRYERS PURPOSE: PROGRAMMING THE OGDEN ETR-9000 TEMPERATURE CONTROLLER NOTE: Use Rev. 3 to correct existing open Kettle Fryer settings. (SP1L se ...

  • Belshaw Brothers 718LCG - page 18

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 12 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Menu Overview: There are three main menus that contain parameters that require programming; they are User Menu, Setup Menu, and Calibration Mode. The figure below (Figure 2) shows the sequence ...

  • Belshaw Brothers 718LCG - page 19

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 13 Open Kettle Fryer Parameter Settings Tables 1, 2 and 3 below list of the temperature controller default settings and the Belshaw Factory settings. When installing a new controller 4 of the def ...

  • Belshaw Brothers 718LCG - page 20

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 14 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Table 1 - Parameter Descriptions Set to 375 ºF set to “uSEr” after setup 0ºF 410ºF 0ºF ...

  • Belshaw Brothers 718LCG - page 21

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 15 Table 2 - Parameter Descriptions Set to “nonE” ...

  • Belshaw Brothers 718LCG - page 22

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 16 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Table 3 - Parameter Descriptions Set to ...

  • Belshaw Brothers 718LCG - page 23

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN 17 5 Troubleshooting If you have a problem with your fryer that you cannot solve, call your dealer or another qualified technician. If your dealer cannot help you, please call Belshaw Bros. at (2 ...

  • Belshaw Brothers 718LCG - page 24

    ...

  • Belshaw Brothers 718LCG - page 25

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-1 A Pilot Module This appendix contains supplemental information about the Honeywell S8600 Intermittent Pilot Module. The Belshaw 718LCG, 724CG, and 734CG gas fryers all use this module. Fryers ...

  • Belshaw Brothers 718LCG - page 26

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers module will not energize the second main valve, and the main burner will not light. The S8600F, which is used on natural gas fryers, will continue to spark as long as the fryer’s thermostat ...

  • Belshaw Brothers 718LCG - page 27

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-3 Figure A-1. Normal Operating Sequence. ST A R T TRIAL FO R IGN ITIO N MA I N BUR NE R OP E R A T ION T her mos tat c al l s for heat. F i r s t mai n v al v e opens . G as fl ow s to pi l ot ...

  • Belshaw Brothers 718LCG - page 28

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Step 5: Check Normal Operation 1. Set the fryer’s thermostat above 200°F/93°C. 2. Watch to see whether the pilot lights smoothly when the gas reaches the pilot burner. 3. Watch to see whe ...

  • Belshaw Brothers 718LCG - page 29

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN A-5 A common ground, usually supplied by the pilot burner bracket, is required for the module and the pilot burner/igniter-sensor. 1. Check for good metal-to-metal contact between the pilot burne ...

  • Belshaw Brothers 718LCG - page 30

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 A-6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers c. Make sure the electrical connections are clean and tight. Replace damaged wire with moisture-resistant #18 wire rated for continuous duty up to 221°F/105°C. d. Check to see if ceramic in ...

  • Belshaw Brothers 718LCG - page 31

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN B-1 B Donut-Making Helps Tips on Making Quality Cake Donuts • Use the correct batter temperature. In general, the correct batter temperature is 75 ° -80 ° F/24 ° -27 ° C. Check the mix manu ...

  • Belshaw Brothers 718LCG - page 32

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 B-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers Calculating Correct Water Temperature The following is an example of how to calculate the correct water temperature to use. You must use your own room temperature, dry m ix temperature, desir ...

  • Belshaw Brothers 718LCG - page 33

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-1 C Parts Lists The following pages contain lists of the parts that make up the 718LCG, 724CG, and 734CG Gas Fryers. Each parts list refers to an exploded- view assembly drawing. You can use th ...

  • Belshaw Brothers 718LCG - page 34

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-2 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 718LCG PARTS LIST. ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 232 1 EA POWER CORD, 18GA SJO #PLT-0001 1 EA CLEAR NEON PILOT LIG #PLT-0002 1 EA CLEAR NEON PILOT LIG 618-0007A 2 EA PROOFING SCRE ...

  • Belshaw Brothers 718LCG - page 35

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-3 718LCG PARTS LIST (CONT’D) ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 724G-0183 1 EA SHORTENING CAUTION L 724G-0186 2 EA DOOR MAGNET 724G-0188 2 EA HINGE PIN 724G-0200 1 EA ELECTRICAL BOX CO ...

  • Belshaw Brothers 718LCG - page 36

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-4 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 724CG PARTS LIST. ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 135 1 EA PLUG,BRASS 1/8 I.P.S 618L-0098 1 EA DRAIN VALVE KNOB,EXT 618L-0103 1 EA LABEL,DRAIN VALVE 618L-0105 2 EA WARNING LABEL 618 ...

  • Belshaw Brothers 718LCG - page 37

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-5 734CG PARTS LIST. ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. 232 1 EA POWER CORD, 18GA SJO #PLT-0001 1 EA CLEAR NEON PILOT LIG #PLT-0002 1 EA CLEAR NEON PILOT LIG 618L-0098 1 EA DRAIN VALVE KN ...

  • Belshaw Brothers 718LCG - page 38

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 C-6 MN-1141EN 718LCG, 724CG, and 734CG Gas Fryers 0080A 5 ...

  • Belshaw Brothers 718LCG - page 39

    Belshaw Bros., Inc. • 1750 22 nd Ave. S. • Seattle, WA 98144 • Phone 206-322-5474 • Fax 206-322-5425 718LCG, 724CG, and 734CG Gas Fryers MN-1141EN C-7 734FG PARTS LIST ITEM NUMBER QTY PER UM DESCRIPTION-TRUNC. FM200-0102 6 EA FIBER WASHER 3/4OD 1 FT100-0063 2 EA SUPPORT BRACKET H-0024 6 EA WASHER GREY FIBER 1/16 MDD-0459 1 EA LABEL,WARNING ...

  • Belshaw Brothers 718LCG - page 40

    ...

  • Belshaw Brothers 718LCG - page 41

    Belshaw Brothers Inc. 1750 22 nd Avenue S. Seattle, WA 98144-4590 Phone (206) 322-5474 Fax: (206) 322-5425 Revised 04/04/2006 US/Canada/Mexico Limited Warranty Page 1 US/Canada/Mexico Limited Warranty and Return Policy Belshaw Brothers Inc. warrants parts of its manuf acture and assembly of equipment to be free from defects in workmanship and mater ...

  • Belshaw Brothers 718LCG - page 42

    Belshaw Brothers Inc. 1750 22 nd Avenue S. Seattle, WA 98144-4590 Phone (206) 322-5474 Fax: (206) 322-5425 Revised 04/04/2006 US/Canada/Mexico Limited Warranty Page 2 Exclusions This warranty excludes from its coverage and does not apply to: (a) solenoid and relay coils; (b) lamps; (c) “O” rings; (d) belts; and (e) impellers. These items are ex ...

Produzent Belshaw Brothers Kategorie Fryer

Dokumente, die wir vom Produzenten des Geräts Belshaw Brothers 718LCG erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Belshaw Brothers
- Bedienungsanleitungen 718LCG
- Produktkarten Belshaw Brothers
- Informationsbroschüren
- oder Energieetiketten Belshaw Brothers 718LCG
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Belshaw Brothers 718LCG.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Belshaw Brothers 718LCG, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Belshaw Brothers 718LCG. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Belshaw Brothers 718LCG ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Belshaw Brothers 718LCG, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Belshaw Brothers 718LCG hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Belshaw Brothers 718LCG verständlich ist.

Eine gänzliche Bedienungsanleitung von Belshaw Brothers sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Belshaw Brothers 718LCG bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Belshaw Brothers 718LCG befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Belshaw Brothers 718LCG, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Belshaw Brothers 718LCG - die uns die ersten Schritte während der Nutzung von Belshaw Brothers 718LCG erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Belshaw Brothers 718LCG hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Belshaw Brothers 718LCG im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Belshaw Brothers 718LCG?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Belshaw Brothers 718LCG nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Belshaw Brothers 718LCG hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)