    1 Majestic Fireplaces ® SR/SC Series SR/SC Series W oodbur ning Fireplace For Models: SR36 SR42 SC36 SC42 For use in U.S./Canada Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use. ™ 7412948 4/02 Rev . 7 Homeowner's Installation and Operating Manual ...

  • Vermont Casting SR36 - page 2

    2 Majestic Fireplaces ® SR/SC Series Safety Infor mation PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING FIREPLACE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty . Description The SR/SC Series fireplac ...

  • Vermont Casting SR36 - page 3

    3 Majestic Fireplaces ® SR/SC Series FP590 FP589 Fig. 2 SC36 Series specifications and framing. SC36 Series W oodburning Fireplace — Circulating Model SR36 Series W oodburning Fireplace Fig. 1 SR36 Series specifications and framing. 36" (914mm) 14⁵⁄₈ " (372mm) 15 ³⁄₈ " (391mm) 9¹⁄₂ " (241mm) 40" (1016mm) ...

  • Vermont Casting SR36 - page 4

    4 Majestic Fireplaces ® SR/SC Series SR42 Series W oodburning Fireplace Fig. 3 SR42 Series specifications and framing. FP591 Fig. 4 SC42 Series specifications and framing. SC42 Series W oodburning Fireplace — Circulating Model FP592 42" (1067mm) 46" (1168mm) 36 ⁵⁄₈ " (930mm) ⁵⁄₈ " (16mm) ⁵⁄₈ " (16mm) ¹ ...

  • Vermont Casting SR36 - page 5

    5 Majestic Fireplaces ® SR/SC Series Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. FP554 Fig. 5 Fireplace and chase parts identification. TERMINATION CAP STORM COLLAR PAN FLASHING DRAFTSTOP FIRESTOP ST ANDOFF NAILING FLANGE GAS LINE ACCESS (both sides) ELECTRICAL ACCESS OUTSIDE AIR ...

  • Vermont Casting SR36 - page 6

    6 Majestic Fireplaces ® SR/SC Series Chimney Requirements - Offset Installations 0000 0 3 " 1 1 " 1000 0 8 ¹⁄₄ " 20" 0100 0 1 1 ¹⁄₄ "2 5 ¹⁄₄ " 2000 0 1 3 ¹⁄₂ "2 9 ¹⁄₄ " 1100 0 1 6 ¹⁄₂ "3 4 ¹⁄₄ " 0010 0 2 0 ¹⁄₄ "4 0 ³⁄₄ " 2100 0 2 1 ³⁄₄ &qu ...

  • Vermont Casting SR36 - page 7

    7 Majestic Fireplaces ® SR/SC Series Planning Infor mation Preplanning an installation is very important to ensure safety and to save time and money . An installer must predetermine where a fireplace will be set and how the chimney system will be run. Mounting The Fireplace A fireplace may only be mounted on the following surfaces: 1. A flat combu ...

  • Vermont Casting SR36 - page 8

    8 Majestic Fireplaces ® SR/SC Series ■ 1. Insulating Fireplace Enclosure For Cold Climates If you live in a cold climate, it is not required but highly recommended that you insulate fire- place enclosure to eliminate cold air penetration as much as possible. Insulate base of fireplace with a non-combus- tible insulation rated for a minimum of 30 ...

  • Vermont Casting SR36 - page 9

    9 Majestic Fireplaces ® SR/SC Series ■ 2. Framing Framing can be constructed before or after the fire- place is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 X 4 lumber or heavier materials. Refer to framing dimensions in Figures 1, 2, 3 or 4 for basic fireplace specifications. Note: ...

  • Vermont Casting SR36 - page 10

    10 Majestic Fireplaces ® SR/SC Series Straight-Up Chimney Installation To mark the centerline of the flue, put the fireplace in final position and measure out from the wall: 9 ¹⁄₄ inches. Mark a spot on the ceiling directly above the fireplace. Draw a line parallel to the back wall through this mark. (Fig. 1 1) Using a plumb bob positioned di ...

  • Vermont Casting SR36 - page 11

    11 Majestic Fireplaces ® SR/SC Series Note: Safety strips are not required over non-combus- tible floors where all supports at the base of the fireplace are non-combustible. Four (4) nailing flanges are supplied with the fireplace (found on the fireplace hearth). T o level the box and secure it firmly in place, remove the nailing flanges from the ...

  • Vermont Casting SR36 - page 12

    12 Majestic Fireplaces ® SR/SC Series Continue installing the pipe as required until pipe is installed up through the ceiling. At this point, you must install a firestop spacer . Installing the Firestop Spacer in the Ceiling Hole A firestop spacer is used to keep pipe spaced properly and required for safety . Nail the firestop spacer (at each corn ...

  • Vermont Casting SR36 - page 13

    13 Majestic Fireplaces ® SR/SC Series Install the attic insulation shield with the flanges on its base extending down into the framing hole. Nail each corner of attic insulation shield to the framing members of the ceiling hole using 8d nails. Attic shields are not required at the roof. Continue Installing Pipe to Complete Run Continue attaching p ...

  • Vermont Casting SR36 - page 14

    14 Majestic Fireplaces ® SR/SC Series ■ 7. Installing T op Housing Or T ermination Follow the installation instructions provided with the V ermont Castings, Majestic Products chimney termina- tion you have selected. Installing Chimney In a Chase Refer to Figure 5, Page 5 for an illustration of a typical chase installation. CAUTION: T reatment of ...

  • Vermont Casting SR36 - page 15

    15 Majestic Fireplaces ® SR/SC Series Side W all Protection Adjacent combustible side walls that are within the minimum dimensions shown in Figure 23 of fireplace opening must be protected with V ermont Castings, Majestic Products W all Shield Model SP40 or a specifically built wall shield described below . The special wall shield design described ...

  • Vermont Casting SR36 - page 16

    16 Majestic Fireplaces ® SR/SC Series ■ 9. Hearth Installation A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 23 for minimum dimensions and mounting detail. Note: Hearth Extension must not cover the air inlet opening of a fireplace. The hearth extension described in Figure 23 must be a du ...

  • Vermont Casting SR36 - page 17

    17 Majestic Fireplaces ® SR/SC Series COMMON MA TERIALS AND F A CT ORS MA TERIAL K* R MINIMUM THICKNESS EH2416 Common Brick 0.458 5.0 1.09 0.50 in.** 0.10 5.46 in.** (Majestic Products Company) R V alue is f or ¹⁄₂ inch. * Units of K = BTU/SQ FT/HR/˚F/IN ** Thic kness of Listed Material FP533ADD Example of Determining Hearth Extension Equiva ...

  • Vermont Casting SR36 - page 18

    18 Majestic Fireplaces ® SR/SC Series ■ 10. Installing Line For Gas Logs V ermont Castings, Majestic Products fireplaces are designed to accept a 1/2 inch gas line for installation of an approved gas appliance. (V ermont Castings, Majestic Products manufactures a wide variety of gas logs for use in V ermont Castings, Majestic Products fireplaces ...

  • Vermont Casting SR36 - page 19

    19 Majestic Fireplaces ® SR/SC Series SR/SC36/42 Series SR/SC36 SR/SC42 Item/Model Number Part Number Part Number 1. Damper Weld Assembly RP199 RP199 2. Damper Bracket 3030176 3030176 3. Screen Rod Assembly 3030126 30321 12 4. Screen* 7554338 7554340 5. Screen Pulls 5584139 5584139 6a. Firebrick - Hearth 3041 103 3034105 6b. Firebrick - Rear 30301 ...

  • Vermont Casting SR36 - page 20

    20 Majestic Fireplaces ® SR/SC Series The following accessories for this appliance are available from your local V ermont Castings, Majestic Products distributor . Should you need additional information beyond what your distributor can furnish, contact: V ermont Castings, Majestic Products, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, ...

  • Vermont Casting SR36 - page 21

    21 Majestic Fireplaces ® SR/SC Series Chimney Components Round T op T ermination T op used to terminate chimney at roof. RL TSK8 (Flashing not included.) Round T op T ermination - T op used to terminate chimney at chase. RL TSK8L Extended (Flashing not included.) Flashing Metal finishing required around Contemporary 8-6-12 with 8" flue: T erm ...

  • Vermont Casting SR36 - page 22

    22 Majestic Fireplaces ® SR/SC Series Chimney Collar Enclosure Installs on the "over the chimney collar" of the CCE-SK fireplace; provides outside air to assist in cooling the chimney system. Attic Insulation Shield Used to prevent insulation from coming in AIS-SK contact with the chimney system. SK8 Chimney Sections Used to build chimne ...

  • Vermont Casting SR36 - page 23

    23 Majestic Fireplaces ® SR/SC Series ™ LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems V ermont Castings, Majestic Products warrants its MAJESTIC FIREPLACES® Pre-Engineered Fireplace (“Fireplace”) and V ermont Castings, Majestic Products supplied firegrate, glass doors, outside ai ...

  • Vermont Casting SR36 - page 24

    24 Majestic Fireplaces ® SR/SC Series © V ermont Castings, Majestic Products 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com Ve r mont Castings, Majestic Products ...

Produzent Vermont Casting Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Vermont Casting SR36 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Vermont Casting
- Bedienungsanleitungen SR36
- Produktkarten Vermont Casting
- Informationsbroschüren
- oder Energieetiketten Vermont Casting SR36
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Vermont Casting SR36.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Vermont Casting SR36, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Vermont Casting SR36. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Vermont Casting SR36 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Vermont Casting SR36, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Vermont Casting SR36 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Vermont Casting SR36 verständlich ist.

Eine gänzliche Bedienungsanleitung von Vermont Casting sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Vermont Casting SR36 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Vermont Casting SR36 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Vermont Casting SR36, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Vermont Casting SR36 - die uns die ersten Schritte während der Nutzung von Vermont Casting SR36 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Vermont Casting SR36 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Vermont Casting SR36 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Vermont Casting SR36?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Vermont Casting SR36 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Vermont Casting SR36 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)