    ® VDVF36PN/PP (PENINSULA) AND VDVF36STN/STP (SEE-THRU) SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appli- ance, it also contains information that will enable you to obtain replacement parts or optional accessory items when needed. Keep it with your other important papers. (Peninsula Show ...

  • Desa VDVF36STN/STP - page 2

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 2 Figure 1 - VDVF36PN/PP (Peninsula) Dimensions FRONT VIEW 30" (76cm) (Opening) 25" (64cm) 19 7 / 8 " (50cm) (Opening) RIGHT SIDE 1 1 / 4 " (3cm) 22 5 / 8 " (57cm) 41 1 / 8 " (104cm) 32" (81cm) (Opening) 1 7 / 8 &q ...

  • Desa VDVF36STN/STP - page 3

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 FRONT VIEW 30" (76cm) (Opening) 23 5 / 8 " (60cm) 25" (64cm) RIGHT SIDE 22 5 / 8 " (57cm) 43 1 / 8 " (110cm) 32" (81cm) (Opening) 1 7 / 8 " (5cm) 1 1 / 4 " (3cm) B A CK VIEW 39 3 / 4 " (101cm) 26 3 / ...

  • Desa VDVF36STN/STP - page 4

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 4 WARNING: Installation and repair should be done by a qualified service person. The appliance should be inspected before use, and at least annually there- after by a qualified service person. More frequent cleaning may be required due to excessive ...

  • Desa VDVF36STN/STP - page 5

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Surround: ......................................... 0" min. • V ent Surfaces: ............................................... 1" (2.54cm) min. • Ceiling to Op ...

  • Desa VDVF36STN/STP - page 6

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 6 39 3 / 4 " (101cm) Min. 4 3 1 / 4 " ( 1 0 9 . 8 c m ) 2 3 5 / 8 " ( 6 0 c m ) 39 3 / 4 " (101cm) Min. 4 0 1 / 2 " (1 0 2 .9 c m ) 2 3 5 / 8 " ( 6 0 c m ) * Figure 8 - Rough Opening for Installing Peninsula Fireplace o ...

  • Desa VDVF36STN/STP - page 7

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 3" (7.6cm) 1" (2.5cm) Dia. Hole 3" (7.6cm) 2" (5.1cm) Dia. Hole 1" (2.5cm ) 2" (5.1cm ) Height Depends On Installation 10" (25.4cm) Square Min. Figure 10 - Hole Locations For Gas Line and Electric Wires for Pen ...

  • Desa VDVF36STN/STP - page 8

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 8 Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porc ...

  • Desa VDVF36STN/STP - page 9

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 WARNING: Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could resu ...

  • Desa VDVF36STN/STP - page 10

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 10 Figure 16 - Vent Pipe Connections Installing Vent System in a Chase A chase is a vertical box-like structure built to enclose venting that runs along the outside of a building. A chase is not required for such venting. NOTICE: Treatment of firest ...

  • Desa VDVF36STN/STP - page 11

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 VENTING INST ALLA TION Continued Note: Horizontal runs of vent must be supported every three feet. Use wall straps for this purpose. Flexible vent pipe must be installed with spacer springs every 12". See Figure 16, page 10 . All connecti ...

  • Desa VDVF36STN/STP - page 12

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 12 V enting with T wo 90 ° Elbo ws V ertical (V) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 4' max. 6' min. 8' max. 7' min. 10' max. 8' min. 15' max. 20' max. 20' max. Figure 23 - Horizontal Term ...

  • Desa VDVF36STN/STP - page 13

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 VENTING INST ALLA TION Continued 1. Determine the route your vertical venting will take. If ceiling joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 24) to avoid cutting loadbearing member ...

  • Desa VDVF36STN/STP - page 14

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 14 Figure 26 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 27 - Installed Cathedral Ceiling Support Box Vertical Termination Configurations Figures 28 through 31 show four diff ...

  • Desa VDVF36STN/STP - page 15

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been CSA tested and approved for operation at altitudes in the USA from 0-2000 ft. and in Canada from 0-45000 ft. When installing this fireplace at an elevation above 2000 feet ...

  • Desa VDVF36STN/STP - page 16

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 16 INST ALLA TION WALL SWITCH INSTALLATION Since the VDVF36 series models use a valve that operates on millivolt current generated by the pilot, a wall switch may be used to activate the gas control valve without the use of normal household electric ...

  • Desa VDVF36STN/STP - page 17

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 Figure 33 - Wall Switch Wiring Diagram WARNING: Do not wire remote wall switch to main power supply (Standard 120v household current). Note: If any of the original wire supplied must be replaced, use type 18 AWG-105 degree C (25 feet length MA ...

  • Desa VDVF36STN/STP - page 18

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 18 WARNING: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is open, apply a soap and water solution to all connections and joints. If bubbles appear, leaks can be detect ...

  • Desa VDVF36STN/STP - page 19

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 GAS SUPPLY TESTING Note: This section is intended as a guide for qualified service technicians installing gas to the appliance. CAUTION: Do not connect appliance before pres- sure testing gas piping. Damage to the gas valve may result and an u ...

  • Desa VDVF36STN/STP - page 20

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 20 WARNING: Improper installation, adjustment, al- teration, service, or maintenance can cause injury or property damage. Refer to this manual. For assis- tance or additional information, consult a qualified installer, service agency, or gas supplie ...

  • Desa VDVF36STN/STP - page 21

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 BURNER FLAME ADJUSTMENT The air shutter, located at the underside of the main burner (see Figure 48), has been factory preset to the proper air-to-gas ratio which results in an even, clean burning flame across the burner (see Figure 49). If re ...

  • Desa VDVF36STN/STP - page 22

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 22 OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life. A. This appliance has a pilot which mus ...

  • Desa VDVF36STN/STP - page 23

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be perf ormed. LIGHTING INSTRUCTIONS 1. STOP! Read the safety inf or mation in co l umn 2, page 22, bef ore pr oceedin ...

  • Desa VDVF36STN/STP - page 24

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 24 Ther mocouple Incoming Main Gas Supply Piezo Ignitor Control V alve V ar iable Speed Control * Remote Control Electrical Rating: 120v , 60Hz, 0.7A Blow er * Use Extension Cord (Included With Kit) Pilot TH TP TPTH Ther mopile Piezo Ignitor Do Not ...

  • Desa VDVF36STN/STP - page 25

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 TROUBLESHOOTING OBSERVED PROBLEM Pilot will not light No gas to burner, although wall switch and valve are set to the ON position Frequent pilot outage Burner goes off after a short time When ignitor button is pressed, there is no spark at pil ...

  • Desa VDVF36STN/STP - page 26

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 26 TROUBLESHOOTING Continued POSSIBLE CAUSE 1 . Gas supply turned of f or equipment shutoff valve closed 2. Control knob not in PILOT position 3. Control knob not pressed in while in PILOT position 4. Air in gas lines when installed 5 . Depleted gas ...

  • Desa VDVF36STN/STP - page 27

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Glass soots Fireplace prod ...

  • Desa VDVF36STN/STP - page 28

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 28 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neigh ...

  • Desa VDVF36STN/STP - page 29

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 ACCESSORIES RECEIVER AND HAND-HELD ON/OFF REMOTE CONTROL KIT - GHRC SERIES For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control. LOG SET - 105891-01 (27237) Log Piece A - 105896-01 (27238) Log P ...

  • Desa VDVF36STN/STP - page 30

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 30 GAS CONTROL VALVE Natural - 105882-01 (25699) Propane/LP - 105882-02 (25700) If in need of replacing, have a qualified technician replace it. ORIFICE Natural - 105890-01 (27224) Propane/LP - 105890-02 (25238) REFRACTORY PIECES Front (Bottom) - 10 ...

  • Desa VDVF36STN/STP - page 31

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 1. Where will the product be used? ❍ Living/Family Room ❍ Office/W arehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product yourself, did you plan to purchase this type of product be ...

  • Desa VDVF36STN/STP - page 32

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 32 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE T APE ...

  • Desa VDVF36STN/STP - page 33

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________ ...

  • Desa VDVF36STN/STP - page 34

    105706-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 34 LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operate ...

Produzent Desa Kategorie Outdoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Desa VDVF36STN/STP erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Desa
- Bedienungsanleitungen VDVF36STN/STP
- Produktkarten Desa
- Informationsbroschüren
- oder Energieetiketten Desa VDVF36STN/STP
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Desa VDVF36STN/STP.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Desa VDVF36STN/STP, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Desa VDVF36STN/STP. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Desa VDVF36STN/STP ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Desa VDVF36STN/STP, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Desa VDVF36STN/STP hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Desa VDVF36STN/STP verständlich ist.

Eine gänzliche Bedienungsanleitung von Desa sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Desa VDVF36STN/STP bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Desa VDVF36STN/STP befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Desa VDVF36STN/STP, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Desa VDVF36STN/STP - die uns die ersten Schritte während der Nutzung von Desa VDVF36STN/STP erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Desa VDVF36STN/STP hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Desa VDVF36STN/STP im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Desa VDVF36STN/STP?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Desa VDVF36STN/STP nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Desa VDVF36STN/STP hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)