Bedienungsanleitung Kohler CH1000

20 Seiten 0.93 mb
Download

Zur Seite of 20

Summary
  • Kohler CH1000 - page 1

    1 O WNER ' S M ANUAL H ORIZONT AL C RANKSHAFT COMMAND PRO CH940-CH1000 ...

  • Kohler CH1000 - page 2

    2 Safety Precautions T o ensure safe operations please read the following statements and understand their meaning. Also refer to your equipment owner's manual for other important safety information. This manual contains safety precautions which are explained below . Please read carefully . W ARNING W arning is used to indicate the presence of ...

  • Kohler CH1000 - page 3

    3 Safety Precautions (Cont.) Lethal Exhaust Gases! Engine exhaust gases contain poisonous carbon monoxide. Carbon monoxide is odorless, colorless, and can cause death if inhaled. Avoid inhaling exhaust fumes, and never run the engine in a closed building or confined area. Accidental Starts! Disabling engine. Accidental starting can cause severe inj ...

  • Kohler CH1000 - page 4

    4 Figure 1. T ypical Command PRO Horizontal Shaf t Engine. Oil Recommendations Using the proper type and weight of oil in the crankcase is extremely important. So is checking oil daily and changing oil regularly . It is also recommended that a consistent brand of oil be used. Failure to use the correct oil, or using dirty oil, causes premature engi ...

  • Kohler CH1000 - page 5

    5 Fuel Recommendations W ARNING: E x plosive Fuel! Gasoline is extremely flammable and its vapors can explode if ignited. Store gasoline only in approved containers, in well ventilated, unoccupied buildings, away from sparks or flames. Do not fill the fuel tank while the engine is hot or running, since spilled fuel could ignite if it comes in conta ...

  • Kohler CH1000 - page 6

    6 Operating Instructions Also read the operating instructions of the equipment this engine powers. Figure 6. Throttle and Choke Control Linkage in Inner Pull Configuration. W ARNING: L e t h a l E x h a u s t G a s e s ! Engine exhaust gases contain poisonous carbon monoxide. Carbon monoxide is odorless, colorless, and can cause death if inhaled. A ...

  • Kohler CH1000 - page 7

    7 Figure 8. Optional Control Panel with Engine Mounted Controls. 2. Start the engine by activating the key switch. Release the switch as soon as the engine starts. N OT E : Do not crank the engine continuously for more than 10 seconds at a time. If the engine does not start, allow a 60 second cool down period between starting attempts. Failure to f ...

  • Kohler CH1000 - page 8

    8 Check Oil Level The importance of checking and maintaining the proper oil level in the crankcase cannot be overemphasized. Check oil BEFORE EACH USE as follows: 1. Make sure the engine is stopped, level, and is cool so the oil has had time to drain into the sump. 2. T o keep dirt, debris, etc., out of the engine, clean the area around the dipstic ...

  • Kohler CH1000 - page 9

    9 Figure 9. Dipstick and Oil Fill. 4. Remove the dipstick and check the oil level. The oil level should be up to, but not over , the F mark on the dipstick. See Figure 10. Figure 10. Oil Level Marks on Dipstick. 5. If the level is low , remove the cap from the v alv e cover and add oil of the proper type, up to the F mark on the dipstick. (Refer to ...

  • Kohler CH1000 - page 10

    10 Figure 15. Optional Remote Mounted Oil Filter . Replace the oil filter as follows: 1. Before removing the oil filter , clean the area around the oil filter and housing to keep dirt and debris out of the engine. Remove the old filter . On crankcase mounted oil filter housings, a spring loaded inner cup allows automatic oil drainback into the cran ...

  • Kohler CH1000 - page 11

    11 T o access and service the oil cooler, remov e the top mounting screw and loosen the two side screws, then lift off the No. 2 side cylinder shroud. If required, remove the two screws holding the oil cooler to the blower housing. Pull the cooler away from the blower housing. Clean both sides of the cooler with a brush as shown in Figures 17 and 1 ...

  • Kohler CH1000 - page 12

    12 Figure 21. Removing Elements. 3. After the paper element is removed, check the condition of the inner element. It should be replaced whenever it appears dirty , typically every other time the paper element is replaced or every 600 hours . Clean the area around the base of the inner element before removing it, so dirt does not get into the engine ...

  • Kohler CH1000 - page 13

    13 Ignition System An electronic Capacitive Discharge (CD) ignition system is used. Other than periodically checking/ replacing the spark plugs, no maintenance, timing, or adjustments are necessary or possible with this system. Check Spark Plugs Every 200 hours of operation, remove the spark plugs, check condition, and reset the gap. Replace with n ...

  • Kohler CH1000 - page 14

    14 Figure 26. Keihin T wo-Barrel Carburetor . N OT E : Carburetor adjustments should be made only after the engine has warmed up. N OT E : T o ensure correct engine operation at altitudes above 1525 meters (5000 ft.), it may be necessary to have an authorized Kohler dealer install a special high-altitude jet kit in the carburetor . If a high-altitu ...

  • Kohler CH1000 - page 15

    15 Adjust Carburetor Low Idle Speed (RPM) and Governed Idle Adjustment 1. Low Idle Speed (RPM) Setting: Place the throttle control into the idle or slow position. Hold the governor lever away from carburetor so the throttle lever is against the Idle Speed (RPM) Adjustment Screw of carburetor . See Figure 26. Set the low idle speed to 1200 RPM* (± ...

  • Kohler CH1000 - page 16

    16 T roubleshooting When troubles occur , be sure to check the simple causes which, at first, may seem too obvious to be considered. For example, a starting problem could be caused by an empty fuel tank. Some common causes of engine troubles are listed in the following table. Do not attempt to service or replace major engine components, or any item ...

  • Kohler CH1000 - page 17

    17 Specifications Model : ................................................................... CH940 .................... CH960 .................. CH980 .............................. CH1000 B o r e : ................................................ mm (in.) ..... 90 (3.54) ................. 90 (3.54) ............... 90 (3.54) ...................... ...

  • Kohler CH1000 - page 18

    18 KOHLER CO. FEDERAL AND CALIFORNIA EMISSION CONTROL SYSTEMS LIMITED W ARRANTY SMALL OFF-ROAD AND CLASS 1 LSI ENGINES The U.S. Environmental Protection Agency (EP A), the California Air Resources Board (CARB), and Kohler Co. are pleased to explain the Federal and California Emission Control Systems W arranty on your off-road equip ment engine. In ...

  • Kohler CH1000 - page 19

    19 Listed below are the parts covered by the Federal and California Emission Control Systems W arranty . Some parts listed below may require scheduled maintenance and are warranted up to the first scheduled replacement point for that part. The warranted parts include the following if they were present in the engine purchased: • Oxygen sensor (if ...

  • Kohler CH1000 - page 20

    ENGINE DIVISION, KOHLER CO., KOHLER, WISCONSIN 53044 FOR SALES AND SERVICE INFORMA TION IN U.S. AND CANADA, CALL 1-800-544-2444 LITHO IN U.S.A. FO RM N O .: 62 590 01-A ISSUED: 1 / 0 7 REVISED: 4 / 0 9 KohlerEngines.com ...

Produzent Kohler Kategorie Automobile Parts

Dokumente, die wir vom Produzenten des Geräts Kohler CH1000 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Kohler
- Bedienungsanleitungen CH1000
- Produktkarten Kohler
- Informationsbroschüren
- oder Energieetiketten Kohler CH1000
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Kohler CH1000.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Kohler CH1000, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Kohler CH1000. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Kohler CH1000 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Kohler CH1000, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Kohler CH1000 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Kohler CH1000 verständlich ist.

Eine gänzliche Bedienungsanleitung von Kohler sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Kohler CH1000 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Kohler CH1000 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Kohler CH1000, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Kohler CH1000 - die uns die ersten Schritte während der Nutzung von Kohler CH1000 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Kohler CH1000 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Kohler CH1000 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Kohler CH1000?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Kohler CH1000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Kohler CH1000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)