    ® Technical Guide SPLIT -SYSTEM EV APORA TOR BLOW ERS K2EU060, K4EU090, K3EU120 & K3EU180 5 THRU 15 NOMINAL TONS 036-21300-002-A-09 05 FOR DISTRIBUTION USE ONL Y - NOT TO BE USED A T POINT OF RET AIL SALE DESCRIPTION These completely assembled un its include a well-insulated cabinet, a DX cooling coil with copper tubes and aluminum fin s, expa ...

  • York K4EU090 - page 2

    036-21300-002-A-09 05 2 Unitary Products Group TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 ACCESSORIES—FIELD INSTALLED . . . . . . . . . . . . . . . . 1 NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 APPLICATION FLEXIBILITY . . . . . . . . . . . . . . . . . ...

  • York K4EU090 - page 3

    036-21300-002-A-0905 Unitary Products Group 3 NOMENCLATURE ACCESSORIES-FIELD INS T ALLED (CONT .) HOT W A TER COILS These drainable coi ls have 2 rows of 1/2" co pper tubes, 12 aluminum fins per inch, a casing th at is finished to match the exterior of the basic unit, but no wate r control valve. The coils slide out of their casings for easy f ...

  • York K4EU090 - page 4

    036-21300-002-A-09 05 4 Unitary Products Group MODEL 15 TON These units have two distinct mod ules . . . a blower module and a coil module. Although th e unit is always shipped in the vertical position with a vertical air discharge as shown in illus- tration (a), the blower module can be repositioned in the field as shown in illustrations (b) and ( ...

  • York K4EU090 - page 5

    036-21300-002-A-0905 Unitary Products Group 5 FIGURE 3 - SUSPENSION MOUNTING (H ORIZONTAL) - KEU060, 090 AND 120  + %5   + %5    +%5  + %5   !)2 /54 !)2 ). &(17(5 2)? ...

  • York K4EU090 - page 6

    036-21300-002-A-09 05 6 Unitary Products Group NOTE: These values have been accessed using a mode l of soun d pr op agation from a poi nt source into t he hemispheric f ree field. Th e dBA values provided are for reference only . Calcul ation of dBA values cove r mat ters of system design and the fan ma nufacturer has no wa y of knowing the details ...

  • York K4EU090 - page 7

    036-21300-002-A-0905 Unitary Products Group 7 T ABLE 4: HEATING CAPACITY - ELECTRIC HEAT ACCESSORY UNIT MODEL HEA TER MODEL VOL T AGE TEST NOMINAL RA TINGS 1 CAP AC ITY 1ST ST AGE 2ND ST AGE KW MBH KW MBH KW MBH 060 2HT045010 25 208 / 240 2 10 34.2 10 34.2 - - 2HT045016 25 208 / 240 2 16 54.7 10 34.2 6 20.5 2HT045026 25 208 / 240 2 26 88.9 16 54.7 ...

  • York K4EU090 - page 8

    036-21300-002-A-09 05 8 Unitary Products Group NOTE: Steam rate (lb./hr.) = 1.025 x MBH CAUTION: Do NOT operate a motor above its nominal HP ratin g when a unit is equipped with a steam coi l acces- sory. NOTE: W ater T emperature Drop, 0 F = 2 x MBH CAUTION: Do NOT operat e a motor above it s nominal HP rati ng when a unit is equipped with a hot w ...

  • York K4EU090 - page 9

    036-21300-002-A-0905 Unitary Products Group 9 T ABLE 9: SUPPLY AIR BLOWER PERFORMANCE - KEU060 (5 TON) CFM EXTERNAL ST A TIC PRESSURE 0.2 0.4 0.6 0.8 RPM W BHP RPM W BHP RPM W BHP RPM W B HP 1400 677 74 0.08 753 174 0.19 831 2 68 0.29 912 355 0.38 1600 725 225 0.24 801 325 0.35 879 419 0.45 959 506 0.54 1800 773 366 0.39 849 466 0.50 927 560 0.60 1 ...

  • York K4EU090 - page 10

    036-21300-002-A-09 05 10 Unitary Products Group T ABLE 10: SUPPLY AIR BLOWER PERFORMANCE - K EU090 (7.5 TON) CFM EXTERNAL ST A TIC PRESSURE 0.2 0.4 0.6 0.8 RPM W BHP RPM W BHP RPM W BHP RPM W B HP 2200 561 281 0.30 612 400 0.43 670 530 0.57 734 661 0.71 2400 579 414 0.44 630 533 0.57 688 663 0.71 752 794 0.85 2600 599 542 0.58 649 662 0.71 707 792 ...

  • York K4EU090 - page 11

    036-21300-002-A-0905 Unitary Products Group 11 T ABLE 1 1: SUPPLY AIR BLOWER PERFORMA NCE - KEU120 (10 TON) CFM EXTERNAL ST A TIC PRESSURE 0.2 0.4 0.6 0.8 RPM W BHP RPM W BHP RPM W BHP RPM W BHP 2800 571 122 0.13 630 332 0.36 682 489 0.52 733 618 0.66 3000 595 349 0.37 654 559 0.60 706 716 0.77 756 845 0.91 3200 619 558 0.60 678 768 0.82 730 925 0. ...

  • York K4EU090 - page 12

    036-21300-002-A-09 05 12 Unitary Products Group T ABLE 12: SUPPLY AIR BLOWER PERFORMANCE - K EU180 (15 TON) CFM EXTERNAL ST A TIC PRESSURE 0.2 0.4 0.6 0.8 RPM W BHP RPM W BHP RPM W BHP RPM W BHP 4000 555 382 0.41 594 620 0.67 633 851 0.91 676 1085 1.16 4200 562 616 0.66 600 854 0.92 640 1085 1.16 683 1319 1.42 4400 569 828 0.89 608 1066 1.14 648 12 ...

  • York K4EU090 - page 13

    036-21300-002-A-0905 Unitary Products Group 13 T ABLE 13: ST ATIC RESIST ANCE FOR UN IT ACCESSORIES (I WG) - KEU060-120 CFM Electric Heat KW Supply Air Plenum Return Air Grill Hot W ater Coil Steam Coil 10 16 26 36 2200 0.01 0.01 0.03 0.04 0.02 0.02 0.07 0.1 1 2400 0.01 0.0 2 0.03 0.05 0.03 0.03 0.09 0.13 2600 0.01 0.0 2 0.04 0.06 0.03 0.03 0.10 0. ...

  • York K4EU090 - page 14

    036-21300-002-A-09 05 14 Unitary Products Group T ABLE 15: SUPPLY AIR PLENUM PERFORMANCE DATA Model CFM Face Ve l o c i t y (FPM) Angle of Deflection Ve r t i c a l Louvers 1 (Plan Vie w) Horizontal Louvers 2 (Elevati on View) Ve r t i c a l Louvers (Plan View ) Horizontal Louvers (Elevation View ) Ve r t i c a l Louvers (Plan View ) Horizontal Lou ...

  • York K4EU090 - page 15

    036-21300-002-A-0905 Unitary Products Group 15 T ABLE 17: KEU PHYS ICAL DATA Component Descript ion Model 060 090 120 180 EVAPORATOR BLOWER 1 Centrifugal Blower (Dia. X Wd. in.) 15 X 15 15 X 15 15 X 15 18 X 18 Fan Motor HP (Belt Drive) 3/4 1-1/2 2 3 EVAPORATOR COIL Rows Deep 3 3 3 3 Finned Length (in.) 30 46 46 54 Fins per Inch 13 13 13 13 Face Are ...

  • York K4EU090 - page 16

    036-21300-002-A-09 05 16 Unitary Products Group ACCESSORIES • ELECTRIC HEA TER - Add 13” to unit height when used. • SUPPL Y AIR PLENUM - Add 24-1/4” to unit height when used. • BASE - Add 20” to unit height when used. FIGURE 1 - UNIT DIMENSIONS KEU060  +./#+/54 2EMOVEDONLYWHEN %LECTRIC(EAT!CCESSOR ...

  • York K4EU090 - page 17

    036-21300-002-A-0905 Unitary Products Group 17 ACCESSORIES • ELECTRIC HEA TER - Add 14-1/4” to unit h eight when used. • SUPPL Y AIR PLENUM - Add 27-1/2” to unit height when used. • BASE - Add 20” to unit height when used. FIGURE 2 - UNIT DIMENSIONS KEU090 & 120  +./#+/54 2EMOVEDONLYWHEN %LECTRIC( ...

  • York K4EU090 - page 18

    036-21300-002-A-09 05 18 Unitary Products Group ACCESSORIES • ELECTRIC HEA TER - Add 14-1/4” to unit height when using 10, 16, 26, or 36 KW heater • SUPPL Y AIR PLENUM - Add 27” to unit height when used. • BAS E - Add 24” to unit height when used. • HOT W A TER OR STEAM COIL - Add 6” to unit depth w hen used. FIGURE 3 - UNIT DIMENSI ...

  • York K4EU090 - page 19

    036-21300-002-A-0905 Unitary Products Group 19 Plenum Model Unit Model Plenum Dimensions (inches) ABC DE F G H K L 1SP0450 060 36 25-1/2 34-2/8 31-3/4 15-3/4 7-5/8 7/8 2-1/8 1 1-1/4 2 1SP0451 090 120 52-1/8 28-1/4 27-1/2 49-3/8 17-7/8 8-3/4 7/8 1-1/8 1 5-1/4 1-3/4 1SP0452 180 60-3/4 31 27 55-3/4 19-7/8 6-1/8 1 - 2-1/2 19-1/2 1-3/4 ( * ) + ' $ ...

  • York K4EU090 - page 20

    036-21300-002-A-09 05 20 Unitary Products Group T ABLE 21: ELECTRIC HEA TER DIME NSIO NS KEU060, 09 0, 120 & 18 0 Heater Model Nom. kW Unit Model Heater Dimensions (inches) ABC D E F GHK LM 2HT04501025 1 2HT04501625 1 2HT04502625 1 10 16 26 060 25-1/8 22-1/2 13 7 /8 4 1/2 5-1/4 1-1 1/16 1-3/4 20 -1/8 16-7/8 2HS04501025, 46, 58 2HS04501625, 46, ...

  • York K4EU090 - page 21

    036-21300-002-A-0905 Unitary Products Group 21 FIGURE 8 - STEAM COIL B A D 2 E F 1-1/2" NPTE CONNS. C Coil Model Unit Model Steam Coil Dimensions ( inches) A BCD E F 1NF0450 1 1. Installs ove r the return air opening of the unit- before the filters. 060 36 21-7/8 5 2-1/2 2-5/8 10-5/8 1NF0451 1 090 52 25 5 2-1/2 2-5/8 13-5/8 1NF0451 1 120 52 25 ...

  • York K4EU090 - page 22

    036-21300-002-A-09 05 22 Unitary Products Group T ABLE 22: KEU ELECTRICAL DATA Model (TONS) Power Supply Vo l t a g e Indoor Motor FLA Heater Model Number Nominal Heater KW Applied Heater KW Electric Heat Amps Min. Circuit Ampacity (AMPS) Max. Fuse 1 / HACR Breaker 2 (AMPS) 060 3 (5) 208 7.6 None -- -- -- 9.5 15 2HT04501025 10 7.5 20.8 35.6 40 2HT0 ...

  • York K4EU090 - page 23

    036-21300-002-A-0905 Unitary Products Group 23 T ABLE 22: KEU ELECTRICAL DATA (CONTINUED) Model (TONS) Power Supply Vo l t a g e Indoor Motor FLA Heater Model Number Nominal Heater KW Applied Heater KW Electric Heat Amps Min. Circuit Ampacity (AMPS) Max. Fuse 1 / HACR Breaker 2 (AMPS) 180 (15) 208 10.6 None -- -- -- 13.3 20 2HS04501025 10 7.5 20.8 ...

  • York K4EU090 - page 24

    036-21300-002-A-09 05 24 Unitary Products Group FIGURE 10 - FIELD WIRING FOR POWER SUPPLY COOLING ONLY UNITS AN D UNITS WITH STEAM OR HOT WATER COIL ACCESSORY T ERMINALS ON SU PP LY AIR B LOWER MOTOR CONTACTOR 10M GROUN D SCREW P OWER WIRING, D ESCONNECT SWITCH AN D FUSING TO B E SU PP LIE D B Y FIEL D LINE VOLTAGE P OWER SU PP LY *Not required on ...

  • York K4EU090 - page 25

    036-21300-002-A-0905 Unitary Products Group 25 FIGURE 13 - FIELD WIRI NG FO R UNITS WITH ELECTRIC HEAT R Y 1 Y 2 W 1 W 2 G 1 1 2 R Y O 6 6 6 0 5 3 G B 2 4 - V O L T C O N T R O L W I R I N G T E R M I N A L B L O C K 4 T B O N B L O W E R U N I T J U M P E R A n o u t d o o r t h e r m o s t a t c a n b e w i r e d b e t w e e n t e r m i n a l s 5 ...

  • York K4EU090 - page 26

    036-21300-002-A-09 05 26 Unitary Products Group ...

  • York K4EU090 - page 27

    036-21300-002-A-0905 Unitary Products Group 27 ...

  • York K4EU090 - page 28

    Subject to change without notice. Pr inted in U.S.A. 036-21300-002-A-09 05 Copyright © by Unitary Products Group 2005. All rights reserved. Supersedes: 036-21 300-001-A-0901 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York K4EU090 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen K4EU090
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York K4EU090
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York K4EU090.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York K4EU090, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York K4EU090. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York K4EU090 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York K4EU090, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York K4EU090 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York K4EU090 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York K4EU090 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York K4EU090 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York K4EU090, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York K4EU090 - die uns die ersten Schritte während der Nutzung von York K4EU090 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York K4EU090 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York K4EU090 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York K4EU090?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York K4EU090 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York K4EU090 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)