Bedienungsanleitung American International Electric SEG-1

34 Seiten 6.92 mb
Download

Zur Seite of 34

Summary
  • American International Electric SEG-1 - page 1

    Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual Section 1: Introduction SECURITY WARNING: New SEG's shipped after April 2008 will have Telnet setup option enabled by default. Enabling Telnet on the SEG allows you (the customer) to be able to configure the settings of the SEG via LAN without requiring the seri ...

  • American International Electric SEG-1 - page 2

    Table of Contents Section 1: Introduction ........... .......... ........... .......... .......... ........... .......... ........... .......... ........... ........... .... .... .1 Section 2: Product Overview ............ .......... .......... ........... .......... ........... .......... ........... ........... .... .... .... .... ... 3 2.1 Produ ...

  • American International Electric SEG-1 - page 3

    Section 2: Product Overview 2.1 Product Specifications The chart below contains the environmental and electrical specifications. Electrical Voltage 12VDC (9V Min; 20V Max) Current 150mA @ 9V; 100mA @ 20V Environmental Temperature 0° to 70 ° C (32° to 158° F) Humidity 0-95% RH Non-condensing Environment Indoor Only 2.2 LED Status The following d ...

  • American International Electric SEG-1 - page 4

    Section 3: Hardware Installation The following section contains information about installing the SEG-1 and SEG-M hardware. 3.1 SEG-1 Diagrams Page 4 of 34 Document Nu mber: 6066 005, Rev 3. 2 ...

  • American International Electric SEG-1 - page 5

    3.2 Connection the SEG-1 to a HubMax or Hub MiniM ax (RS-232) Two different methods can be used to connect Port A of the HubMax or HubMiniMax to the SEG-1: 1. Connect to the RS232 modular jack (front of SEG-1) 2. Connect to the RS232 terminals (rear of SEG-1) NOTE: If connection to SEG-1 is NOT located at the HubMax or HubMiniMax then the connectio ...

  • American International Electric SEG-1 - page 6

    3.3 Connecting the SEG-1 to HC500P (RS-232) Two different methods to can be used to connect Port A of the HC500P to the SEG-1 1. Connect to the RS232 modular jack (front of SEG-1) 2. Connect to the RS232 terminals (rear of SEG-1) NOTE: If connection to SEG-1 is NOT located at the HC500P then the connection must be made via stranded/shielded cable. ...

  • American International Electric SEG-1 - page 7

    3.4 Connecting Multiple HubMax/Hub MiniMax Netw orks Document N umber: 60660 05, Rev 3.2 Page 7 of 34 ...

  • American International Electric SEG-1 - page 8

    3.5 Connecting the SEG-1 to a prox.pad p lus (RS-485) Two different methods can be used to connect P5 Connector of the prox.pad plus to the SEG-1: 1. Connect to the RS485 modular jack (front of SEG-1) 2. Connect to the RS485 terminals (rear of SEG-1) NOTE: If connection to SEG-1 is NOT located at the prox.pad plus then the connection must be made v ...

  • American International Electric SEG-1 - page 9

    3.6 Connecting Multiple prox.pad plus Netw orks Document N umber: 60660 05, Rev 3.2 Page 9 of 34 ...

  • American International Electric SEG-1 - page 10

    3.7 Connecting the SEG-1 to a Max 3 System ( RS-485) You can also use the SEG-1 to connect your Max 3 or MiniMax 3 system to your LAN/WAN. Follow the instructions below and refer to the diagram. Run y our RS-485 cable between terminal strip TS1 on the SEG-1 to TS 3 on the backplane as shown in the diagram. You must also connect each module to the b ...

  • American International Electric SEG-1 - page 11

    3.8 Connecting the SEG-1 to a MiniMax 3 System (RS-485) You can also use the SEG-1 to connect your MiniMax 3 s y stem to your LAN/WAN. Follow the instructions below and refer to the diagram. Run y our RS-485 cable between terminal strip TS1 on the SEG-1 to TS 3 on the backplane as shown in the diagram. You must also connect the module to the backpl ...

  • American International Electric SEG-1 - page 12

    3.9 SEG-M Installation (Plug On Module) The SEG-M plug on module was created to allow HubMax and Mi niMax panels an easier way to use the SEG-M functionality. When used with HubMax or Hub MiniMax panels, no power or communication wiring is required between the SEG-M and the backplane. All connections are made through the connector used to connect t ...

  • American International Electric SEG-1 - page 13

    3.9.2 SEG-M Connectors The chart below describes the connectors on the S EG-M. Connector Description Pin Configuration J1 RS-485 Data Connector Pin Label Description 1 A RS-485 Data A (+) 2 B RS-485 Data B (-) 3 GND RS-485 Data GND 4 A RS-485 Data A (+) 5 B RS-485 Data B (-) 6 GND RS-485 Data GND S1 Power/RS-232 Data Connector Power/RS-232 Connecto ...

  • American International Electric SEG-1 - page 14

    3.9.4 Connecting the SEG-M to a HubMax S ystem (RS-232) Connect the SEG-M to the eight-position pin rail S1 above the first module on the backplane. Make sure the components on the SEG- M are facing away from the module. Use the t wo card guides to secure the SEG-M in place by snapping them into the holes on either side and sliding the SEG-M into t ...

  • American International Electric SEG-1 - page 15

    3.9.6 Connecting the SEG-M to a Max 3 System (RS-485) You can connect your Max 3 to your LAN/WAN by using the SEG-M, Secured Ethernet Gateway. Follow the instructions below and refer to the diagram. The connection from the SEG-M to the Max 3 requires you to plug the modul e onto the backplane connector S1 to power the unit. You must also use the si ...

  • American International Electric SEG-1 - page 16

    3.9.7 Connecting the SEG-M to a MiniMax 3 System (R S-485) You can connect your MiniMax 3 to your LAN/WAN by using the SEG-M, S ecured Ethernet Gateway . Follow the instructions below and refer to the diagram. The connection from the SEG-M to the MiniMax 3 requires you to pl ug the module onto the backplane connector J2 to power the unit. You must ...

  • American International Electric SEG-1 - page 17

    Section 4: SEG Configuration The SEG is a device created for the purpose of allowing data to be exported from your PC over a LAN/WAN to either Secured S eries Controllers or the prox.pad Plus. A minimal amount of setup must be performed on the SEG in order for it to be properly addressed on the LAN. There are 3 methods that can be used to configure ...

  • American International Electric SEG-1 - page 18

    Page 18 of 34 Document Number : 60660 05, Rev 3.2 Figure 1: No SEG parameters defined Figure 2: SEG firmware requirements ...

  • American International Electric SEG-1 - page 19

    Document N umber: 606 6005, R ev 3.2 Pa ge 19 of 34 Figure 3: Found SEG's are displayed in grid Figure 4: Select a SEG ...

  • American International Electric SEG-1 - page 20

    4.2 Dynamic IP A ddress, non-expiring lease No setup of the SEG via the serial port is required. Just supply the SEG's MAC address (the 12 digit number located on the label on the SEG; for example 00-20-4A-52-F2-84) to the IT department and ask them to assign it an IP Address with a non-expiring lease. Once you have the IP address that the IT ...

  • American International Electric SEG-1 - page 21

    4.3 Static IP A ddress The static IP address can be set through the serial port of the S EG using the PC's serial communications port (or through the USB port using a USB to RS232 adapter). This method allows you to configure the IP address of the SEG without any network devices such as a router or a network switch interfering. Refer to the se ...

  • American International Electric SEG-1 - page 22

    8. Disconnect power to the SEG (if it was powered up). 9. Press and hold down the x key (lowercase) on the PC keyboard while the HyperTerminal program is running. 10. Power up the SEG. 11. In a few seconds you should get a response from the SEG asking y ou to press enter to go into Setup Mode. 12. Release the x key. 13. After pressing ENTER to go i ...

  • American International Electric SEG-1 - page 23

    4. Type cmd and then press OK. A DOS prompt will appear. 5. Type the following and press enter: telnet <IP address of SEG> 9999 (for example: telnet 192.168.1.1 9999 ) 6. You should get a response from the SEG asking you to press enter to go into S etup Mode. 7. Press enter to enter the setup menu of the SEG. 8. Now go to section “4.3.3 SEG ...

  • American International Electric SEG-1 - page 24

    4.3.3 SEG Setup Menu 1. To change the IP address you should select option 0 server Configu ration . A 3 digit number will be displayed in brackets. This is the first 'octet' of the current IP address of this SEG device. You will either enter a new 3 digit number and then press enter to accept it, or you can accept this num ber by pressing ...

  • American International Electric SEG-1 - page 25

    Here is a brief description of each m enu and sub option, and what the default values should be. The SEG device is factory set to have the highest security possible. Changing any options, especially i n the 'Security' menu could result in not having a completely secure environment. 0 – Sever Configuration IP Address (XXX).(XXX).(XXX).(X ...

  • American International Electric SEG-1 - page 26

    6 – Security Here you can change the Encryption key manually to match the encry ption ke y Hub Manager Professional is using. This is normally not necessary because Hub Manager Professional normall y performs this function. After going through this menu item completely, the encryption settings will automaticall y be saved and the session will be ...

  • American International Electric SEG-1 - page 27

    4.3.4 Configuring the IP Address in H ub Manager Professional Now it is time to open Hub Manager Professional, create a new site, and configure this site to communicate to the SEG wit h the I P address you have received from the IT administrator. Thi s example shows how to set up a SEG connected Hub controller network, but the SEG can also be used ...

  • American International Electric SEG-1 - page 28

    4.4.5 Generate Random Security Key This button will generate a new 128 bit security key and wi ll then display the hexadecimal representation in the 'Current Security Key' field (see below) 4.4.6 Generate Default Security Key After selecting this option, you will receive a warning m essage explaining that setting the security key back to ...

  • American International Electric SEG-1 - page 29

    4.5.2 Reset the Security Key in the SEG to a ll 0's NOTE: This requires SEG firmware v1.30 or higher. This feature is provided to allow you to reset the S ecurity Key in the SEG back to all 0's, which is the default out-of-box state. Resetting the Security Key in the SEG would be required if y ou are replacing a SEG with a previously used ...

  • American International Electric SEG-1 - page 30

    Section 5: Trouble Shooting Page 30 of 34 Document Number : 60660 05, Rev 3.2 ...

  • American International Electric SEG-1 - page 31

    Document N umber: 606 6005, R ev 3.2 Pa ge 31 of 34 ...

  • American International Electric SEG-1 - page 32

    Page 32 of 34 Document Number : 60660 05, Rev 3.2 ...

  • American International Electric SEG-1 - page 33

    Section 6: FCC Compliance Statement This equipment has been tested and found to comply with the limi ts for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated i n a commercial environment. This equipment generates, use ...

  • American International Electric SEG-1 - page 34

    Page 34 of 34 Document Number : 60660 05, Rev 3.2 International Electronics, Inc. 427 Turnpike St. Canton, MA 02021 U.S.A. Phone: 800-343-9502, 781-821-5566 Fax: 781-821-4443 Website: www .ieib.com ...

Produzent American International Electric Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts American International Electric SEG-1 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen American International Electric
- Bedienungsanleitungen SEG-1
- Produktkarten American International Electric
- Informationsbroschüren
- oder Energieetiketten American International Electric SEG-1
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung American International Electric SEG-1.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen American International Electric SEG-1, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen American International Electric SEG-1. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts American International Electric SEG-1 ansehen.

Die komplette Bedienungsanleitung des Geräts American International Electric SEG-1, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von American International Electric SEG-1 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von American International Electric SEG-1 verständlich ist.

Eine gänzliche Bedienungsanleitung von American International Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von American International Electric SEG-1 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von American International Electric SEG-1 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich American International Electric SEG-1, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts American International Electric SEG-1 - die uns die ersten Schritte während der Nutzung von American International Electric SEG-1 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit American International Electric SEG-1 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von American International Electric SEG-1 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich American International Electric SEG-1?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit American International Electric SEG-1 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit American International Electric SEG-1 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)