Bedienungsanleitung A.O. Smith 305 Series 100

40 Seiten 0.65 mb
Download

Zur Seite of 40

Summary
  • A.O. Smith 305 Series 100 - page 1

    PRINTED 0209 186965-001 Design information for single and multiple unit installations for residential, commercial, recircula- tion and storage tank systems. On-Demand Water Heater System Design Manual ...

  • A.O. Smith 305 Series 100 - page 2

    2 Certifications .................................................................................. 3 Water Quality and Scale ................................................................ 8 Pump Sizing for Circulation .......................................................... 9 Tank Water Heaters in a Circulation Loop Additional Guidelines Pump ...

  • A.O. Smith 305 Series 100 - page 3

    3 Certified to applicable U.S. standards for appliances using gas or other petroleum fuel. Certified to applicable Canadian standards for appliances using gas or other petroleum fuel. Certified by the Uniform Plumbing Code (UPC) Certified by National Sanitation Foundation (NSF), www.nsf.org (indoor models must use the NSF approved top guard) Air-Co ...

  • A.O. Smith 305 Series 100 - page 4

    Consumer Information The on-demand water heaters must be installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1 (NFPA 54) - current edition. CSA American, Inc. National Fire Protection Association 8501 East Pleasat Valley Road 1 Batterymarch Park Cleveland, OH 4413 ...

  • A.O. Smith 305 Series 100 - page 5

    In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, should be used at hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturer’s instructions for installation of the valves. Before ...

  • A.O. Smith 305 Series 100 - page 6

    Closed System/Thermal Expansion CAUTION - PROPERTY DAMAGE HAZARD As water is heated, it expands (thermal expan- sion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pres- sure due to thermal expansion. Thermal expan- sion can cause premature tank failure (leakage). T ...

  • A.O. Smith 305 Series 100 - page 7

    Temperature and Pressure Relief Valve For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening on the on-demand storage tank. This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed eq ...

  • A.O. Smith 305 Series 100 - page 8

    8 W a ter Quality and Scale A complete water analysis and an unde rstandi ng of system requirements are needed to protect the on-demand water heaters and water heating systems from scale. Water analysis shows whether water is hard or soft. Hard water, unless treated, will cause scaling or liming of the heat exchanger. The rate of scaling increases ...

  • A.O. Smith 305 Series 100 - page 9

    9 Pump Sizing for Circulation 1. Use the chart below or one appropriate for your con ditions to determine the heat loss in the length of the hot water supply and return piping. For example, 100 ft of 1-1/2 in bare copper tubing results in a heat loss of 5300 Btu/h. 2. Determine the acceptable temperature drop at the last fixture in the loop. For ex ...

  • A.O. Smith 305 Series 100 - page 10

    10 T ank W a ter Heaters in a Circulation Loop The following applies when using a tank water heater (gas or electric) to provide heat for a circulation loop. Drawing H-1-RP is an example. The heat output of the tank must be equal to or greater t han the calculated circulation loop heat loss. (Reference page 5, Step 1 on calculating heat loss). Elec ...

  • A.O. Smith 305 Series 100 - page 11

    The following applies when using on-demand water heaters to recover a storage tank. Drawing H-1-TC is an example. On-Demand water heaters have a pressure loss which must be considered in the system design. Reference the pressure loss curve for the heater m odel being used to determine the pump size for the desired recovery rate. For recommended pum ...

  • A.O. Smith 305 Series 100 - page 12

    12 Pressure Loss (psi) Water Flow (gpm) 0. 0 5. 0 10. 0 15. 0 20. 0 25. 0 30. 0 35. 0 40. 0 45. 0 01 234 56 789 1 0 1 1 0. 0 10. 0 20. 0 30. 0 40. 0 50. 0 60. 0 Pressure Loss (ft head) 305 i 505 305 e Figure “4” Pressure Loss Curves 100/101 Series ...

  • A.O. Smith 305 Series 100 - page 13

    13 Pressure Loss (psi) Water Flow (gpm) Pressure Loss (ft head) Figure “5” 0 5 10 15 20 25 30 35 40 45 0123456789 1 0 1 1 0 10 20 30 40 50 60 70 80 90 100 705 505 305 Pressure Loss Curves 200/201 Series ...

  • A.O. Smith 305 Series 100 - page 14

    Domestic Hot W ater - S tandard Installation 1 On-Demand W ater Heater Preferred Piping Installation Drawing Number: Drawing Date: H-1 September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance wit ...

  • A.O. Smith 305 Series 100 - page 15

    Domestic Hot W ater - S tandard Installation 2 On-Demand W ater Heaters Preferred Piping Installation Drawing Number: Drawing Date: H-2 September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance wi ...

  • A.O. Smith 305 Series 100 - page 16

    Domestic Hot W ater - S tandard Installation 3 On-Demand W ater Heaters Preferred Piping Installation Drawing Number: Drawing Date: H-3 September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance wi ...

  • A.O. Smith 305 Series 100 - page 17

    Domestic Hot W ater - S tandard Installation 4 On-Demand W ater Heaters Preferred Piping Installation Drawing Number: Drawing Date: H-4 September 07, 2008 Pr i ma ry Hot W ater Supply Line Cold W ater Supply Line Gas Supply Su b 1 Su b 2 Su b 3 On-Demand Equipment List QTY On-Demand 4 W ater Heaters Electronic Connection * * Refer to On-Demand Acce ...

  • A.O. Smith 305 Series 100 - page 18

    Domestic Hot W ater - S tandard Installation 5 On-Demand W ater Heaters Preferred Piping Installation Drawing Number: Drawing Date: H-5 September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance wi ...

  • A.O. Smith 305 Series 100 - page 19

    Domestic Hot W ater - S tandard Installation 6 On-Demand W ater Heaters Preferred Piping Installation Drawing Number: Drawing Date: H-6 September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance wi ...

  • A.O. Smith 305 Series 100 - page 20

    Drawing Number: Drawing Date: H-1-E September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 21

    Drawing Number: Drawing Date: H-2-E September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 22

    Drawing Number: Drawing Date: H-3-E September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 23

    Drawing Number: Drawing Date: H-6-E September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 24

    Drawing Number: Drawing Date: H-1-RP September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 25

    Drawing Number: Drawing Date: H-1-RO September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 26

    Drawing Number: Drawing Date: H-2-RP September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 27

    Drawing Number: Drawing Date: H-2-RO September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 28

    Drawing Number: Drawing Date: H-3-RP September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 29

    Drawing Number: Drawing Date: H-6-RP September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 30

    Drawing Number: Drawing Date: H-1-T September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 31

    Drawing Number: Drawing Date: H-1-TC September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 32

    Drawing Number: Drawing Date: H-2-T September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 33

    Drawing Number: Drawing Date: H-2-TC September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 34

    Drawing Number: Drawing Date: H-3-T September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 35

    Drawing Number: Drawing Date: H-3-TC September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 36

    Drawing Number: Drawing Date: H-6-T September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 37

    Drawing Number: Drawing Date: H-6-TC September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 38

    Drawing Number: Drawing Date: MP-01 September 07, 2008 NOTE: This drawing is not intended to describe a complete system and is not a replacement for a pro- fessional engineering drawing. It is intended only as a guide and does not imply compliance with local building code requirements. Confer with local building officials before installation . The ...

  • A.O. Smith 305 Series 100 - page 39

    39 Notes ...

  • A.O. Smith 305 Series 100 - page 40

    • 500 T ennessee Waltz Parkway • Ashland, TN 37015 • ...

Produzent A.O. Smith Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts A.O. Smith 305 Series 100 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen A.O. Smith
- Bedienungsanleitungen 305 Series 100
- Produktkarten A.O. Smith
- Informationsbroschüren
- oder Energieetiketten A.O. Smith 305 Series 100
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung A.O. Smith 305 Series 100.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen A.O. Smith 305 Series 100, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen A.O. Smith 305 Series 100. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts A.O. Smith 305 Series 100 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts A.O. Smith 305 Series 100, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von A.O. Smith 305 Series 100 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von A.O. Smith 305 Series 100 verständlich ist.

Eine gänzliche Bedienungsanleitung von A.O. Smith sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von A.O. Smith 305 Series 100 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von A.O. Smith 305 Series 100 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich A.O. Smith 305 Series 100, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts A.O. Smith 305 Series 100 - die uns die ersten Schritte während der Nutzung von A.O. Smith 305 Series 100 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit A.O. Smith 305 Series 100 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von A.O. Smith 305 Series 100 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich A.O. Smith 305 Series 100?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit A.O. Smith 305 Series 100 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit A.O. Smith 305 Series 100 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)