  • Lochinvar 399 - 800 - page 1

    User ’ s Information Manual Models: 399 - 800 If the information in this manual is not followed exactly , a fir e or explosion may r esult causing property damage, personal injury or loss of life. This appliance MUST NO T be installed in any location wher e gasoline or flammable vapors are likely t o be present. WHA T T O DO IF Y OU SMELL GAS • ...

  • Lochinvar 399 - 800 - page 2

    2 Hazar d definitions The following defined terms are used thr oughout this manual to bring attention to the presenc e of hazards of various r isk level s or to important information concerning the life of the product.  DANGER  W ARNING  CAUTION CAUTION NOTICE D ANGER indicates an imminently hazardous situation which, if not avoided, w ill ...

  • Lochinvar 399 - 800 - page 3

    User ’s Information Manual Please r ead bef ore pr oceeding The Knight XL Installation and Operation Manual along with the Knight XL Serv ice Man ual are for use only by a qualified heating installer/serv ice technician. Refer only to this U ser’ s Information Man ual for your refer ence. Improper installation, adjustment, alt eration, serv ice ...

  • Lochinvar 399 - 800 - page 4

    User ’s Information Manual 1 Prev ent combustion air contamination 4 If the boiler combustion air inlet is located in a laundr y room or pool facility , for example, these areas will alwa ys co ntain hazardous c ontaminants. T o pr event the potential of severe personal injur y or death, check for areas and pr oducts listed in T able 1A before in ...

  • Lochinvar 399 - 800 - page 5

    User ’s Information Manual 2 Maintenance sc hedule 5  W ARNING Follow the maint enance pr ocedur es given thr oughout this manual. Failur e to perform the serv ice and maintenance or follo w the directions in this manual c ould result in damage t o the boiler or system, resulting in sever e personal injury , death, or substantial property dama ...

  • Lochinvar 399 - 800 - page 6

    User ’s Information Manual 6 2 Maintenance sc hedule Maintenance procedur es Boiler must be ser viced and maintained  W ARNING The boiler must be inspected and started annually at the beginning of the heating season by a qualified serv ice tec hnician. In addition, the maintenance and car e of the boiler designated on page 5 of this manual and ...

  • Lochinvar 399 - 800 - page 7

    User ’s Information Manual 2 Maintenance sc hedule (continued) 7 3. Fill with fresh water until the water begins to pour out of the drain. 4. Replac e the cap . Press the cap onto the trap until the cap makes c ontact with the drain. 5. Replac e the retaining scr ew .  W ARNING The condensate trap (FIG. 2-1) must be filled with water during al ...

  • Lochinvar 399 - 800 - page 8

    User ’s Information Manual 2 Maintenance sc hedule 8  W ARNING Hav e leaks fixed at once b y a qualified serv ice technician. Failure to co mply could result in sever e personal injury , death, or substantial property damage. Operate relief valve 1. Before pr oceeding, verify that the relief valve outlet has been piped to a safe place of disch ...

  • Lochinvar 399 - 800 - page 9

    User ’s Information Manual 9 3 Oper a ting instr uctions FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury , or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically l ...

  • Lochinvar 399 - 800 - page 10

    User ’s Information Manual 10 4 SMART SY STEM contr ol module • Hold 5 seconds to enter code Input Mode (Menu Mode) • Press to move up one level in Menu Mode or to exit Menu Mode • Press to turn boiler off or back on • Press to select a menu item • Press after parameter programming to store parameter data • Press to exit Service Mode ...

  • Lochinvar 399 - 800 - page 11

    User ’s Information Manual 11 Access modes User The user can adjust space heating target temperatur e by using the UP and DO WN buttons (FIG. 4-1) at any time during normal operation. By ent ering the USER code (0704), the user can also change temperature units, time and date, and night setback settings. In U ser Mode, the following parameters ca ...

  • Lochinvar 399 - 800 - page 12

    User ’s Information Manual 12 4 SMART SY STEM contr ol module Parameter table MENU SUB ITEM DESCRIPTION SEE PAGE USER ACCESS INSTALLER ACCESS DISPLAY MODIFY DISPLAY MODIFY A 1 Boiler Model 13 Ye s No Ye s No 2 User Code 13 Ye s Ye s Ye s Ye s 3 Date and T ime 13 Ye s Ye s Ye s Ye s 4 Software V ersion 13 Ye s No Ye s No 5 T emperature Units 13 Ye ...

  • Lochinvar 399 - 800 - page 13

    User ’s Information Manual 13 A: General Boiler model The control will displa y “Knight Boiler” as the model number because the same contr ol is used on several models. This w ill be display ed when parameter A1 has been accessed. This parameter is not changeable. User code The U ser Code allo ws the user to ac cess and change a limit ed numb ...

  • Lochinvar 399 - 800 - page 14

    User ’s Information Manual 14 4 SMART SY STEM contr ol module E: DHW settings DHW boiler set point W hen a DHW call for heat becomes acti ve, the control will use the DHW boiler set point to determine the firing rate of the boiler based on the actual water temperature. This parameter can be changed by the installer b y accessing parameter E1 . Th ...

  • Lochinvar 399 - 800 - page 15

    User ’s Information Manual 15 Status Display Screens By using the P revious/Next (  ,  ) arrow k eys on the SMAR T SYSTEM displa y panel, you can na v igate through the eight (8) display scr eens. Each scr een will contain two (2) viewable items. The following is a description of the individual items and what they can display: Screen Displa ...

  • Lochinvar 399 - 800 - page 16

    User ’s Information Manual 16 4 SMART SY STEM contr ol module Status Display Screens (cont ’ d) By using the Pr evious/Next (  ,  ) arrow k eys on the SMAR T SYSTEM displa y panel, you can na v igate through the eight (8) display scr eens. Each scr een will contain two (2) viewable items. The following is a description of the individual i ...

  • Lochinvar 399 - 800 - page 17

    User ’s Information Manual 17 Status Display Screens (cont ’ d) By using the P revious/Next (  ,  ) arrow k eys on the SMAR T SYSTEM displa y panel, you can na v igate through the eight (8) display scr eens. Each scr een will contain two (2) viewable items. The following is a description of the individual items and what they can display: ...

  • Lochinvar 399 - 800 - page 18

    User ’s Information Manual 18 4 SMART SY STEM contr ol module Status Display Screens (cont ’ d) Operation of the cascade The boiler designated as the Leader will have tw o additional display scr eens that can be viewed. These screens will pro vide information regarding the operation of the Cascade. Each screen will contain tw o viewable items. ...

  • Lochinvar 399 - 800 - page 19

    User ’s Information Manual 19 Notes ...

  • Lochinvar 399 - 800 - page 20

    Revision Notes: Revision B (KBX-USER-Rev B) reflects changes made to the “Check Air Piping” section on page 6. Revision C (ECO #C02545) reflects the addition of references to periodic cleaning of screens in vent terminations. Revision D (ECO #C02940) reflects the addition of (C to denote Celisius) after 10 under SH Set Point User (pg. 13). Revi ...

Produzent Lochinvar Kategorie Boiler

Dokumente, die wir vom Produzenten des Geräts Lochinvar 399 - 800 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lochinvar
- Bedienungsanleitungen 399 - 800
- Produktkarten Lochinvar
- Informationsbroschüren
- oder Energieetiketten Lochinvar 399 - 800
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lochinvar 399 - 800.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lochinvar 399 - 800, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lochinvar 399 - 800. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lochinvar 399 - 800 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Lochinvar 399 - 800, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lochinvar 399 - 800 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lochinvar 399 - 800 verständlich ist.

Eine gänzliche Bedienungsanleitung von Lochinvar sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lochinvar 399 - 800 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lochinvar 399 - 800 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lochinvar 399 - 800, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lochinvar 399 - 800 - die uns die ersten Schritte während der Nutzung von Lochinvar 399 - 800 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lochinvar 399 - 800 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lochinvar 399 - 800 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lochinvar 399 - 800?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lochinvar 399 - 800 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lochinvar 399 - 800 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.