    Automotive Dealership Design Guide ...

  • Cooper Lighting ADH080747 - page 2

    AUTOMOTIVE DESIGN GUIDE TABLE OF CONTENTS Outdoor Site Lighting that heightens consumer awareness ...................3 - Feature Display Lighting ...................................................................7 - High Competition Displays ...............................................................8 - Medium Competition Displays ............ ...

  • Cooper Lighting ADH080747 - page 3

    SITE | SHOWROOM | SERVICE LEADING THE LIGHTING INDUSTRY Cooper Lighting is a recognized industry leader offering first-class lighting solutions for even the most challenging applications. Addressing every area of an automotive dealership, Cooper Lighting manufactures high performance products that create inviting areas of uniform illumination, endu ...

  • Cooper Lighting ADH080747 - page 4

    3 4 OUTDOOR SITE LIGHTING CONSIDER YOUR LOCATION When selecting the proper light levels for your next dealership project, first determine how much visual competition is created by adjoining properties. The human eye is drawn to the brightest area in its field of view. In order to capture consumer attention, site lighting illuminance levels should b ...

  • Cooper Lighting ADH080747 - page 5

    CONSIDER YOUR IMAGE Site lighting provides a means of navigation through the exterior merchandising area and rounds out the overall aesthetic appeal of the automotive dealership. Whether your style calls for the simple elegance of a square housing or the fluid appeal of a rounded architectural luminaire, Cooper Lighting is a recognized site lightin ...

  • Cooper Lighting ADH080747 - page 6

    5 6 CONSIDER YOUR POCKETBOOK When selecting site lighting products, three important cost factors should be evaluated— fixture construction, energy consumption and maintenance cycle. Corrosive moisture, broad temperature variation and flocking insects make the outdoor environment particularly challenging for optimal luminaire performance. Premium ...

  • Cooper Lighting ADH080747 - page 7

    Lamp Type Lamp Orientation Maintained Lumens Life [hrs.] Input Watts Efficacy [lms/w] 1000W Probe Start MH Vertical 82,000 10,000 1080 102 Horizontal 71,500 9,000 1080 97 1000W Pulse Start MH Vertical 96,000 15,000 1100 109 Horizontal 86,000 9,000 1100 98 875W Pulse Start MH Vertical 80,000 20,000 940 106 Horizontal 76,000 12,000 940 101 750W Pulse ...

  • Cooper Lighting ADH080747 - page 8

    7 8 FEATURE DISPLAY LIGHTING FLEXIBILITY AND VERSATILITY The use of floodlighting products to highlight an automobile on an exterior display stand or platform is a powerful merchandisi ng technique. Directional sources play off the vehicle’s form to reveal its appeal, attracting attention and increasing the likelihood of con necting with the cust ...

  • Cooper Lighting ADH080747 - page 9

    HIGH COMPETITION SITE LIGHTING High Horizontal Maintained Uniformity Area to Illuminate Levels [fc] [Max.Min.] Parking and Circulation [Non-Merchandising Area] 10 10:1 General Merchandise [Main Automotive Display Lot] 50 5:1 Featured Displays [Front Row and Display Stands] 75 3:1 1000W MH FLAT GLASS ENHANCED FRONT ROW DISPLAY Areas with extremely h ...

  • Cooper Lighting ADH080747 - page 10

    9 10 ENHANCED 1000W MH FLAT GLASS ENERGY SAVING DIMMING After hours operation of money and energy saving Hi-Lo dimming relay mounted internal to the fixture. Mounting Height [ft.] 27.5 Spacing [ft.] 55 Maintained Average FC 32.1 Uniformity 1.15 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH ...

  • Cooper Lighting ADH080747 - page 11

    1000W MH FLAT GLASS GENERAL MERCHANDISE DISPLAY IESNA recommends 50 FC average illuminance for areas of high competition. Mounting Height [ft.] 27.5 Spacing [ft.] 60 Maintained Average FC 50.2 Uniformity 1.26 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH Area Round [AR] 3 @ 90° Ta ...

  • Cooper Lighting ADH080747 - page 12

    11 12 MEDIUM COMPETITION SITE LIGHTING 1000W MH FLAT GLASS FRONT ROW DISPLAY IESNA recommends 50 FC average illuminance for areas of medium competition. Mounting Height [ft.] 25 Spacing [ft.] 60 Maintained Average FC 61.9 Uniformity 2.45 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MP ...

  • Cooper Lighting ADH080747 - page 13

    1000W MH FLAT GLASS GENERAL MERCHANDISE DISPLAY IESNA recommends 30 FC average illuminance for areas of medium competition. Mounting Height [ft.] 27.5 Spacing [ft.] 62 Maintained Average FC 31.9 Uniformity 1.16 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH 2 Area Round [AR] 2 @ 180 ...

  • Cooper Lighting ADH080747 - page 14

    13 14 LOW COMPETITION SITE LIGHTING 1000W MH FLAT GLASS FRONT ROW DISPLAY IESNA recommends 35 FC average illuminance for areas of medium competition. Mounting Height [ft.] 2 5 Spacing [ft.] 65 Maintained Average FC 52.5 Uniformity 2.89 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH ...

  • Cooper Lighting ADH080747 - page 15

    1000W MH FLAT GLASS GENERAL MERCHANDISE DISPLAY IESNA recommends 20 FC average illuminance for areas of medium competition. Mounting Height [ft.] 27.5 Spacing [ft.] 93 Maintained Average FC 21.9 Uniformity 1.88 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH 2 Area Round [AR] 2 @ 180 ...

  • Cooper Lighting ADH080747 - page 16

    15 16 SHOWROOM LIGHTING NEO-RAY [Nimbus] AMBIENT METALUX [Ovation] TASK + AMBIENT LUMARK [Avid] TASK + AMBIENT RSA [Combolight] TASK + ACCENT INSPIRATION AND FUNCTIONALITY Showrooms are multifunctional facilities used for customer reception, retail display and business-closing transactions. Discret e tasks performed in each area require custom ligh ...

  • Cooper Lighting ADH080747 - page 17

    SHOWROOM LIGHTING THAT ENHANCES MERCHANDISE APPEAL. PORTFOLIO [MD6] TASK + WALL WASH HALO [Stasis] ACCENT HALO [Connetix] ACCENT SURE-LITES [CCX] SAFETY INVITING Overall dealership ambiance plays a crucial role in evoking a sense of comfort and directly impacts the customer’s ability to make important decisions. A warm and inviting ambiance can b ...

  • Cooper Lighting ADH080747 - page 18

    17 18 SERVICE DEPARTMENT LIGHTING PRODUCTIVITY LEADS TO PROFITABILITY The success of the service department is measured in productivity, and ultimately, profitability. Without proper lighting, the likelihood of costly mistakes and wasted time increases. The appropriate type and level of illumination greatly improves quality and workmanship in gener ...

  • Cooper Lighting ADH080747 - page 19

    SERVICE DEPARTMENT LIGHTING THAT INCREASES PRODUCTIVITY. ENERGY SAVINGS Service department lighting offers a great opportunity to increase energy savings and improve overall profitability. Energy efficient building design practices outlined in the ASHRAE 90.1-2004 standard recommend a maximum power density of 0.7 W/ft 2 for automotive service depar ...

  • Cooper Lighting ADH080747 - page 20

    Cooper Lighting Customer First Center 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 www .cooperlighting.com International Sales, USA Cooper Lighting 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-400 ...

Produzent Cooper Lighting Kategorie Landscape Lighting

Dokumente, die wir vom Produzenten des Geräts Cooper Lighting ADH080747 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Cooper Lighting
- Bedienungsanleitungen ADH080747
- Produktkarten Cooper Lighting
- Informationsbroschüren
- oder Energieetiketten Cooper Lighting ADH080747
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Cooper Lighting ADH080747.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Cooper Lighting ADH080747, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Cooper Lighting ADH080747. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Cooper Lighting ADH080747 ansehen.

Die komplette Bedienungsanleitung des Geräts Cooper Lighting ADH080747, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Cooper Lighting ADH080747 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Cooper Lighting ADH080747 verständlich ist.

Eine gänzliche Bedienungsanleitung von Cooper Lighting sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Cooper Lighting ADH080747 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Cooper Lighting ADH080747 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Cooper Lighting ADH080747, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Cooper Lighting ADH080747 - die uns die ersten Schritte während der Nutzung von Cooper Lighting ADH080747 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Cooper Lighting ADH080747 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Cooper Lighting ADH080747 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Cooper Lighting ADH080747?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Cooper Lighting ADH080747 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Cooper Lighting ADH080747 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)