Bedienungsanleitung Bard Dc3003

22 Seiten 0.77 mb
Download

Zur Seite of 22

Summary
  • Bard Dc3003 - page 1

    Manual 2100-484E Page 1 of 22 DC3002 and DC3003 SOLID ST A TE LEAD/LAG CONTROLLER with DC F AN CONTROL INST ALLA TION INSTRUCTIONS & REPLACEMENT P ARTS LIST Manual No.: 2100-484E Supersedes: 2100-484D File: V ol. III T ab 19 Date: 08-29-1 1 Bard Manufacturing Company , Inc. Bryan, Ohio 43506 Since 1914...Moving ahead, just as planned. ...

  • Bard Dc3003 - page 2

    Manual 2100-484E Page 2 of 22 CONTENTS Getting Other Information and Publications 3 DC3000 General Information Shipping Damage .................................................. 4 General .................................................................. 4 Theory of Operation ............................................... 4 Controller Certificatio ...

  • Bard Dc3003 - page 3

    Manual 2100-484E Page 3 of 22 Getting Other Information and Publications These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard. Standard for the Installation .............. ANSI/NFPA ...

  • Bard Dc3003 - page 4

    Manual 2100-484E Page 4 of 22 SHIPPING DAMAGE Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent. GENERAL NOTE: DC3000 is used throughout this Manual as ...

  • Bard Dc3003 - page 5

    Manual 2100-484E Page 5 of 22 SPECIFICATIONS/FEATURES FOR BASIC CONTROLLER DC3000 Basic Controller •Input power: 18 to 32VAC, 60/50Hz, power is supplied from A/C #1 and/or A/C #2 •Isolation circuitry: no line or low voltage phasing required •Backup power: connection for -24VDC or -48VDC (-20 to -56V) maintains microprocessor operation, front ...

  • Bard Dc3003 - page 6

    Manual 2100-484E Page 6 of 22 Note: All alarm relays are dry contacts rated 1A @ 24VAC, 120VAC or 150VDC. DC3002/3003 CONTROLLER CONNECTIONS Located on Main Controller Board Unit #1 C – 24V AC common R – 24V AC hot G – fan (Form A, NO) Y1 – 1 st -stage cool (Form A, NO) Y2 – 2 nd -stage cool (Form A, NO) W – heat (Form A, NO) Unit #2 C ...

  • Bard Dc3003 - page 7

    Manual 2100-484E Page 7 of 22 LOW VOLTAGE FIELD WIRING The DC3000 is powered from the air conditioners that it is controlling, 24VAC (18-32V) low voltage only. Circuitry in the DC3000 isolates the power supplies of all connected air conditioners so that no back feeds or phasing problems can occur. Additionally, if any air conditioner loses power, t ...

  • Bard Dc3003 - page 8

    Manual 2100-484E Page 8 of 22 SEQUENCE OF OPERATION – COOLING AIR CONDITIONERS – (NO ECONOMIZER) First stage cooling set point is the setting (SP) input into the controller. Factory default is 75F/24C. At Stage 1 cooling SP, the blower of the lead unit will come on (if not already operating because of continuous fan selection for lead unit). Th ...

  • Bard Dc3003 - page 9

    Manual 2100-484E Page 9 of 22 SEQUENCE OF OPERATION – HEATING (AIR CONDITIONERS W/ELECTRIC HEAT) First stage heating set point is the dead band setting below first stage cooling set point (the SP entered into the program). The dead band is adjustable from 2-20F (1-10C), and the factory default is 10F (5C). Second stage heating set point is 2F (1C ...

  • Bard Dc3003 - page 10

    Manual 2100-484E Page 10 of 22 DC FAN CONTROL The primary reason the DC30002 or DC3003 controller system would be used is for additionally controlling a DC Fan ventilation system installed in the shelter in addition to controlling either 2 or 3 HV AC units. The DC Fan package and intake system is independent of the HV AC systems, and is supplied by ...

  • Bard Dc3003 - page 11

    Manual 2100-484E Page 11 of 22 FIGURE 1 DC3002 CONNECTION DIAGRAM 2 UNITS WITH ECONOMIZERS ...

  • Bard Dc3003 - page 12

    Manual 2100-484E Page 12 of 22 FIGURE 2 DC3002 CONNECTION DIAGRAM 2 UNITS NO ECONOMIZERS ...

  • Bard Dc3003 - page 13

    Manual 2100-484E Page 13 of 22 FIGURE 3 DC3003 CONNECTION DIAGRAMS 3 UNITS WITH ECONOMIZERS ...

  • Bard Dc3003 - page 14

    Manual 2100-484E Page 14 of 22 FIGURE 4 DC3003 CONNECTION DIAGRAMS 3 UNITS WITH ECONOMIZERS (NO ECONOMIZER A/C #3) ...

  • Bard Dc3003 - page 15

    Manual 2100-484E Page 15 of 22 FIGURE 5 DC3003 CONNECTION DIAGRAMS 3 UNITS WITH NO ECONOMIZERS ...

  • Bard Dc3003 - page 16

    Manual 2100-484E Page 16 of 22 ALARM WIRING Alarm relays can be wired for NO (close on alarm) or NC (open on alarm) strategy. Alarm relays can be used individually if there are enough available building alarm points, or can be arranged into smaller groups or even a single group so that all alarm capabilities can be utilized. When multiple alarms ar ...

  • Bard Dc3003 - page 17

    Manual 2100-484E Page 17 of 22 FIGURE 6 ALARM BOARD CONNECTIONS FOR NORMALLY CLOSED "NC" OPEN-ON-ALARM STRATEGY ...

  • Bard Dc3003 - page 18

    Manual 2100-484E Page 18 of 22 FIGURE 7 ALARM BOARD CONNECTIONS FOR NORMALLY OPEN "NO" CLOSE-ON-ALARM STRATEGY ...

  • Bard Dc3003 - page 19

    Manual 2100-484E Page 19 of 22 PROGRAMMING INSTRUCTIONS To swap lead and lag unit positions, press the ADVANCE button. To enter the Program mode, press the PROGRAM button and release it when the message PROG appears on the display. When in Program mode, the DOWN and UP arrows are used to scroll through the programming steps. NOTE: When using the UP ...

  • Bard Dc3003 - page 20

    Manual 2100-484E Page 20 of 22 7961-665C Cooling Heati ng 1st Stage 2nd Stage 3rd Stage 4th Stage 1st Stage 4th Stage 3rd Stage 2nd Stage Lead Unit Unit #1 Unit #2 Dehumid . Op er ation Program Advance Comfort Digital Display Temperature at Remote 1 sensor l ocation* Lead-lag-change-over ti me (1 to 30 days or 0 for disabl ed, Default i s 7) Cooli ...

  • Bard Dc3003 - page 21

    Manual 2100-484E Page 21 of 22 FIGURE 8 PARTS LIST DESCRIPTION DIAGRAM 5 7 3 4 6 9 2 11 SEXP- 445 B 8 1 10 ...

  • Bard Dc3003 - page 22

    Manual 2100-484E Page 22 of 22 Parts List . o N . g w D. o N t r a Pn o i t p i r c s e D2 0 0 3 C D3 0 0 3 C D 14 - 3 4 3 - 7 2 1x o B l o r t n o CX X 27 3 0 - 2 1 6 8d r a o B r e l l o r t n o CX X 35 2 0 - 2 1 6 82 0 0 3 B A d r a o B m r a l AX 36 2 0 - 2 1 6 83 0 0 3 B A d r a o B m r a l AX 42 2 0 - 2 1 6 8y a l p s i D m r a l AX 54 - 0 4 ...

Produzent Bard Kategorie Webcam

Dokumente, die wir vom Produzenten des Geräts Bard Dc3003 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Bard
- Bedienungsanleitungen Dc3003
- Produktkarten Bard
- Informationsbroschüren
- oder Energieetiketten Bard Dc3003
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Bard Dc3003.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Bard Dc3003, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Bard Dc3003. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Bard Dc3003 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Bard Dc3003, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Bard Dc3003 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Bard Dc3003 verständlich ist.

Eine gänzliche Bedienungsanleitung von Bard sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Bard Dc3003 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Bard Dc3003 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Bard Dc3003, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Bard Dc3003 - die uns die ersten Schritte während der Nutzung von Bard Dc3003 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Bard Dc3003 hilft