  • Seagate FR-A7AY - page 1

    INVER TER Plug-in option INSTRUCTION MA NUAL 1 2 3 4 5 FR-A7A Y Analog output function Digital output function INST ALLA TION AND WIRING P ARAMETER LIST EXTENSION ANALOG OUTPUT PRE-OPERA TION INSTRUCTIONS DIGIT AL OUT PUT ...

  • Seagate FR-A7AY - page 2

    A-1 Thank you for choosing thi s Mitsu bishi Inverter pl ug-in option. This in struct ion manua l gives h andling infor mation and precau tion s for us e of th is equip ment. Incorrec t handling m ight cause an u nexp ected f ault. Be fore u sing the eq uipm ent, plea se read t his man ual care fully to use the equ ipment to its optim um. Please fo ...

  • Seagate FR-A7AY - page 3

    A-2 2. Injury Prevention 3. Additional I nstructions Also n ote the fo llowin g points to prev ent an accide ntal failur e, injury , ele ctric sh ock, etc. 1) T ransportation and mounting 2) Trial run 3) Usage 4) Maintenance, inspection and part s replaceme nt 5) Di spo sal 6) Ge ne ral i nstr ucti on CAUTION • Appl y only t he vol tage s pecif i ...

  • Seagate FR-A7AY - page 4

    I  CONTENTS  1 PRE-OPE RATIO N INSTRUC TIONS 1 1.1 Unpacking and Product Conf irmation .......................................................................................... ...1 1.1.1 Packing confir mation ......... ......... .......... .......... ............. ......... .......... .......... ............. ......... ....... ......... ... ...

  • Seagate FR-A7AY - page 5

    II 5 DIGITAL OUTPUT 21 5.1 Internal Block Diagram ...................................................................................................... ..............21 5.2 Terminals ................................................................................................................... ....................... 22 5.3 Digital Output Func ...

  • Seagate FR-A7AY - page 6

    1 1 1 PRE-OPERATION INSTRUCTIO NS 1.1 Unpack ing and Pr oduct Con f ir mation T ake the plug-in option out of the p ackage, check the unit name, and c onfirm that the product is as you ordered and intact. This product is a plug-in option dedic ated for the FR-F 700 series . 1.1.1 Packing confirmation Check the enclosed items. Plug-in opt ion ...... ...

  • Seagate FR-A7AY - page 7

    2 PRE-OPE RAT I ON IN ST RUC TI ON S 1.1.2 Parts AMC NC SE Y3 Y4 Y5 Y6 AM0 AM1 NC SE Y0 Y1 Y2 Front view T erminal layout Rear view Mounting hole Mounting hole Mounting hole T erminal block Connector Connect to the inverter option slot (Refer t o page 6. ) ...

  • Seagate FR-A7AY - page 8

    3 PRE-OPE RA TI ON IN ST RU CTION S 1 1.1.3 Specif ications (1) Output signals Voltage output (across terminals AM 0-AMC) 0 to 10VMAXDC Current output (across terminals AM1-AMC) 0 to 20mADC (2) Output resolution Voltage output 3mV Current output 10 µ A (3) Output accuracy (reference value) ±10% of the full-scale output value Depends on the output ...

  • Seagate FR-A7AY - page 9

    4 MEMO ...

  • Seagate FR-A7AY - page 10

    5 2 2 INSTALLATION AN D WIRING 2.1 Pre-Inst allation Inst ructions Make sure that the input power of the inverter is of f. CAUTION With input power on, do not install or remo ve the plug-in option. Ot herwise, the inverter and plug-in op tion may be dam aged. ...

  • Seagate FR-A7AY - page 11

    6 INSTALLATION AND WIRI NG 2.2 Insta llation P r ocedure 1) Remove the inverter front cover. 2) Mount the hex-head screw for option mounting into the inverter screw hole (on earth plate). (size 5.5mm, tightening torque 0.56N ⋅ m to 0.75N ⋅ m) 3) Securely fit the connector of the plug-in option to the inverter connector along the guides. 4) Secu ...

  • Seagate FR-A7AY - page 12

    7 INSTALLATION AND WI RING 2 2.3 Wi ring (1) Strip off the sheath of the cable to wire. Strip off the sheath about the size below. If the length of the s heath pealed is too long, a short circuit may occur among neighboring wires. If the length is too short, wires might come off. (2) Loosen the terminal screw and insert the cable into the terminal. ...

  • Seagate FR-A7AY - page 13

    8 INSTALLATION AND WIRI NG (3) For wiring of the 30K(00620 (EC Version)) o r less , route w ires between the c ontrol circuit ter minal block and front c over. If cables can not be routed between the control c ircuit ter minal block an d front cover due to the increased number of cable s, remove a hook of the front cover and use a space bec ome ava ...

  • Seagate FR-A7AY - page 14

    9 3 3 PARAMETER LIST When the FR-A7A Y is mounted on the inverter , the following parameters are extended. Parameter Number Name Setting Range Minimum Incr em ents Initial V alue Refer to Page EXTENSION A NALOG OUT PUT 306 Anal og ou tput s igna l sel ecti on 1 to 3, 5, 6, 8,(9) , 10 to1 4 ,17, 21 , 24, 50 , 52, 53 12 1 1 an d later 307 Setting for ...

  • Seagate FR-A7AY - page 15

    10 PARAMETER LIST DIGIT AL OU TPUT 313 DO0 out pu t selecti on 0 to 5, ( 7), 8, 10 to 19 , 25, 26 , 45 to 47 , 64, 70, (71 to 78), 86 to 96, 98, 99, 100 to 105 , (107) , 108, 1 10 to 1 16 , 125, 126, 1 45 to 147, 1 64, 170, 1 86 to 196, 1 98, 199, 999 9 1 9999 21 and later 314 DO1 out pu t selecti on 315 DO2 out pu t selecti on 316 DO3 out pu t sel ...

  • Seagate FR-A7AY - page 16

    11 4 4 EXTENSION ANALOG OUTPU T 4.1 Wirin g Example By setting the Pr . 30 6 to Pr . 3 12 values, analog signals such as the output frequency and output current can be output from the voltage output termi nal (AM 0) and current output terminal (AM1) . Connect the voltmeter or ammeter as shown below: CAUTION The wiring length betwe en th e FR-A 7A Y ...

  • Seagate FR-A7AY - page 17

    12 EXTENSION ANALOG OUTPUT 4.2 Inter nal Bl ock Diagr am The following is the inte rnal block diagram about the FR-A7A Y analog output function. Controller Connector AM0 AM1 AMC Current amplifier V oltage amplifier Common to AM0/AM1 ...

  • Seagate FR-A7AY - page 18

    13 EXTENS ION A NALOG OUT PUT 4 4.3 Termi nals T erminal Sym bol T erminal Name Description AM0 V oltage outpu t term ina l Connect a DC voltmeter ( 10VDC). AM1 Curr ent ou t p ut term ina l Co nne ct a D C am meter (2 0m ADC ). AMC Common term ina l Com m on t o AM 0 a nd AM1 Y0 to Y6 Used for an al og output func tion. (R ef er to page 21 ) SE NC ...

  • Seagate FR-A7AY - page 19

    14 EXTENSION ANALOG OUTPUT 4.4 Exten sion Analo g O utput Func ti on Para meter List Parameter Number Name Setting Rang e Min imum Incr em ents Initial Va l u e 306 Anal og out put s igna l sel ection 1 to 3, 5, 6, 8, (9), 10 to 14, 17, 21, 24, 50 , 52, 53 12 307 Setting for zer o an alog out pu t 0 to 100% 0.1 0% 308 Setting for m axi m um a nalog ...

  • Seagate FR-A7AY - page 20

    15 EXTENS ION A NALOG OUT PUT 4 4.5 Adjustm ent Proc edure 4.5.1 Setting of analog out put signal voltage/cur rent switchover ( Pr. 309) Use Pr . 309 Anal og outp ut si gnal v olta ge/c urrent switc hov er to select whether to output the same signal or different si gnals from terminal AM0 (vol tage output) and terminal AM1(current output). Pr . 309 ...

  • Seagate FR-A7AY - page 21

    16 EXTENSION ANALOG OUTPUT 4.5.2 Calibration of meter (1) Outputting the same select signal s from terminals AM0 and AM1 ( Pr . 309 = 0 or 10) CAUTION 1. If ca libration is mad e withou t "2 1" (refe rence vo ltage output ) set in Pr . 306 , T erminals FM/AM of th e i nve rt er is calibrat ed. T o calibrat e th e ext en sion an alog ou tp ...

  • Seagate FR-A7AY - page 22

    17 EXTENS ION A NALOG OUT PUT 4 (2) Outputting different sele ct signals from term inals AM0 and AM 1 ( Pr . 309 = 1 or 11) CAUTION 1. If calibrat ion i s m ade withou t "2 1" (ref ere nce vol tage outp ut ) se t in Pr . 306 or Pr . 310 , terminals FM/AM of the in v erte r i s cali br ated . T o calibr ate th e exten sion an alo g ou t p ...

  • Seagate FR-A7AY - page 23

    18 EXTENSION ANALOG OUTPUT 4.5.3 Output signal setting Set the output signals to be mon itored. Set Pr . 3 06 to output the same signal from terminals AM0 and AM1 and Pr . 30 6 and Pr . 31 0 to output different signals. For detai ls of signal definitions, refer to Pr . 54 an d Pr . 158 of the inverter manual (applied) . *1 Setting can be made on ly ...

  • Seagate FR-A7AY - page 24

    19 EXTENS ION A NALOG OUT PUT 4 4.5.4 Analog signal a djustment [P r. 307, Pr. 308, Pr. 311 , Pr. 312] Use Pr . 30 7 or Pr . 31 1 to set for zero analog output (meter points 0). In addition, use Pr . 308 or Pr . 31 2 to set for maximum analog output (full-scale). Use Pr . 30 7 to set the value for zero analog output and Pr . 30 8 for maximum analog ...

  • Seagate FR-A7AY - page 25

    20 EXTENSION ANALOG OUTPUT 4.6 In structi ons (1) A voltmeter having smaller internal impedance (or an ammeter having larger internal impedance) than the value indicated in the S pecifications may not deflect to full-scale and may not be calibrated. (2) When calibrating a meter which has a small full-scale value, set the output of terminal AM0 (or ...

  • Seagate FR-A7AY - page 26

    21 5 5 DIGITAL O UTPUT 5.1 Inter nal Bl ock Diagr am The following is the inte rnal block diagr am about the FR-A7A Y digital output func tion Controller Connector Y0 Y6 SE Common to Y0-T6 ...

  • Seagate FR-A7AY - page 27

    22 DIGITAL OUTPUT 5.2 Termi nals By setting the Pr . 313 to Pr . 319 values, output signals available with an inverter as st andard can be output from the open collector terminals. (1) Open collector output specifications : Permissible load 24V, 0.1ADC (2) The circuit logic is the same as that of the inverter. For details of changing the control lo ...

  • Seagate FR-A7AY - page 28

    23 DIGITAL OUTPUT 5 5.3 Dig ital Ou tput F unction Para meter List Parameter Number Name Initial V alue Set ti ng Ra nge 313 DO0 ou tput selec tion 9999 0 to 5, (7), 8, 10 to 19, 25, 26, 45 to 47, 64, 70, (71 to 78), 86 to 96, 98, 99 , 100 to 105, (1 07 ), 108, 1 10 to 1 16 , 125, 126, 145 to 147, 164, 170, 186 to 19 6, 198 , 19 9, 9999 314 DO1 ou ...

  • Seagate FR-A7AY - page 29

    24 DIGITAL OUTPUT 5.4 Outpu t S ignal List For details of s ignal definitions, refer to Pr . 190 to Pr . 196 Ou tput termin al fu nctio n sele ctio n of the invert er manua l (applie d) . Setting Signal Name Function Settin g Signal Name Function Posit ive Logic Negati ve Logic Po sitive Logic Negati ve Logic 0 100 RUN Inverter running 15 1 15 FUP ...

  • Seagate FR-A7AY - page 30

    25 DIGITAL OUTPUT 5 *1 Setting ca n be ma de on ly for the 7 5K (0 18 00-EC, S75 K-CH) or m or e. *2 Setting ca n be made onl y fo r EC an d C H ve rsion. *3 Y86 to Y89 ca n not be set from the i nv erte r . 72  RO2 Commercial-power supply side motor 2 connection RO2 *2 90 190 Y90 Life alarm 73  RO3 Commercial-power supply side motor 3 connec ...

  • Seagate FR-A7AY - page 31

    REVISIONS *The manua l numbe r is give n on t he bottom le ft of the bac k cover. Print Date *Manual Number Revision May , 200 4 IB(NA)- 06 00165E NG-A Fir st e dit ion ...

Produzent Seagate Kategorie Marine Battery

Dokumente, die wir vom Produzenten des Geräts Seagate FR-A7AY erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Seagate
- Bedienungsanleitungen FR-A7AY
- Produktkarten Seagate
- Informationsbroschüren
- oder Energieetiketten Seagate FR-A7AY
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Seagate FR-A7AY.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Seagate FR-A7AY, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Seagate FR-A7AY. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Seagate FR-A7AY ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Seagate FR-A7AY, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Seagate FR-A7AY hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Seagate FR-A7AY verständlich ist.

Eine gänzliche Bedienungsanleitung von Seagate sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Seagate FR-A7AY bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Seagate FR-A7AY befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Seagate FR-A7AY, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Seagate FR-A7AY - die uns die ersten Schritte während der Nutzung von Seagate FR-A7AY erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Seagate FR-A7AY hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Seagate FR-A7AY im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Seagate FR-A7AY?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Seagate FR-A7AY nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Seagate FR-A7AY hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen