Bedienungsanleitung Pelco REL2064

20 Seiten 0.85 mb
Download

Zur Seite of 20

Summary
  • Pelco REL2064 - page 1

    REL2064 Relay Interface Unit C1518M-A (11/02) ® INST ALLA TION/OPERA TION ...

  • Pelco REL2064 - page 2

    2 C1518M-A (11/02) CONTENTS Section Page IMPORT ANT SAFEGUARDS AND W ARNINGS .............................................................................................. .................................................................... 3 OVERVIEW .................................................................................................. ...

  • Pelco REL2064 - page 3

    C1518M-A (11/02) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Read, keep, and follow these instructions. 2. Heed all warnings. 3. There are no user -serviceable parts inside this unit. Only authorized service personnel may open the unit. 4. Installation and servicing should only be done by qualified service personnel and conform to all local codes. 5. ...

  • Pelco REL2064 - page 4

    4 C1518M-A (11/02) Figure 1. Front View with Panel Removal OVERVIEW DESCRIPTION The REL2064 Relay Interface Unit provides up to 64 single-pole, single-throw (SPST) dry contact outputs for direct or automatic control of peripheral equipment. Using Pelco’ s proprietary M protocol, the relay unit communicates with Pelco’ s CM6800 matrix switcher v ...

  • Pelco REL2064 - page 5

    C1518M-A (11/02) 5 REAR VIEW The rear of the REL2064 unit consists of the following: 1. Four groups of 16 contact pairs, each with mating plugs for the attachment of peripheral equipment; only the group for the first 16 contact pairs is shown in Figure 2 with mating plugs 2. One RS-485 output communication port (RJ-45 type connector) 3. One RS-485 ...

  • Pelco REL2064 - page 6

    6 C1518M-A (11/02) Figure 3. Rack-Mount Installation WIRING RELA YS The relay unit has four groups of relay contacts. Each group represents 16 pairs of relay contacts: • Group I – 1-8, 9-16 • Group II – 17-24, 25-32 • Group III – 33-40, 41-48 • Group IV – 49-56, 57-64 Each of the four groups contains two connectors with input mating ...

  • Pelco REL2064 - page 7

    C1518M-A (11/02) 7 Figure 4. Relay Interface Contact Configuration 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 00702 ...

  • Pelco REL2064 - page 8

    8 C1518M-A (11/02) Figure 5. Wiring Relays to Peripheral Equipment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32-122F (0-50C) + — 9 WA RNING: W ARNING: 00703 ...

  • Pelco REL2064 - page 9

    C1518M-A (11/02) 9 CONNECTING TO THE CM6800 Connect the supplied RJ-45 straight cable from the REL2064 OUT port to the CM6800 COM 3 port. The active pin-outs are associated with the four outer pins: 1, 2, 7, and 8. Refer to Figure 6. If you want to place the relay unit some distance from the CM6800, the RS-485 communication from the relay unit to t ...

  • Pelco REL2064 - page 10

    10 C1518M-A (11/02) SETTING THE DIP SWITCHES The positioning of the DIP switches on the front of the relay unit deter mines how the relay unit operates. Y ou must recycle pow er whenever you make changes to the DIP switches. 1. Remove the front panel by unscrewing the five flat-head Phillips screws. Y ou see three switches. 1-16 17-32 33-48 49-64 O ...

  • Pelco REL2064 - page 11

    C1518M-A (11/02) 11 2. Set the DIP switches. Figure 7. SW1 DIP Switches DIAGNOSTICS: OFF LOCAL DEVICE ADDRESS ON 1 2 3 4 5 6 7 8 9 10 NOT USED: OFF DEF AUL T SETTINGS: LOCAL DEVICE ADDRESS 1, DIP SWITCH 9 OFF , DIP SWITCH 10 ON 00697 NOT USED: OFF MEMORY (MEM) CONT ACTS 1-16: OFF OR ON 17-32: OFF OR ON 33-48: OFF OR ON 49-64: OFF OR ON NOT CONNECTE ...

  • Pelco REL2064 - page 12

    12 C1518M-A (11/02) OPERA TION The function of the relay unit is to operate relays to control peripheral equipment. Each relay unit processes and executes only commands with addresses that match those of the relay units. When power is turned on, the green power LEDs on the front and back of the unit light. The red data LED light on the front contin ...

  • Pelco REL2064 - page 13

    C1518M-A (11/02) 13 OPERA TING RELA YS FROM THE KBD960 To operate relays from a KBD960 keyboard, you must know which GPI to call, and which auxiliary (AUX) to select on the keyboard. Y ou can cascade two relay units. Each relay unit has eight GPIs. Relay Unit 1 has a GPI range of 1-8, and Relay Unit 2 has a GPI range of 9-16. Refer to T ables C and ...

  • Pelco REL2064 - page 14

    14 C1518M-A (11/02) Table D. Relay Unit 1 GPI Relay Contacts 1 12345678 29 1 0 11 12 13 14 15 16 31 7 1 81 92 02 12 22 32 4 42 5 2 62 72 82 93 03 13 2 53 3 3 43 53 63 73 83 94 0 64 1 4 24 34 44 54 64 74 8 74 9 5 05 15 25 35 45 55 6 85 7 5 85 96 06 16 26 36 4 Associated Aux 12345678 Table E. Relay Unit 2 GPI Relay Contacts 96 5 6 66 76 86 97 07 17 2 ...

  • Pelco REL2064 - page 15

    C1518M-A (11/02) 15 Figure 10. Power Input Fuse Replacement Problem Why were the contact positions lost when there was a power failure? Why is the unit not operating as it should? What is the DB9 port used for? Solution Make sure DIP switches 3-6 of SW3 are enabled so that your settings remain in memory . Make sure the power cord is plugged in and ...

  • Pelco REL2064 - page 16

    16 C1518M-A (11/02) DIP Switch Address 12345678 1 00000000 2 10000000 3 01000000 4 11000000 5 00100000 6 10100000 7 01100000 8 11100000 9 00010000 10 10010000 11 01010000 12 11010000 13 00110000 14 10110000 15 01110000 16 11110000 17 00001000 18 10001000 19 01001000 20 11001000 21 00101000 22 10101000 23 01101000 24 11101000 25 00011000 26 10011000 ...

  • Pelco REL2064 - page 17

    C1518M-A (11/02) 17 DIP Switch Address 12345678 125 00111110 126 10111110 127 01111110 128 11111110 129 00000001 130 10000001 131 01000001 132 11000001 133 00100001 134 10100001 135 01100001 136 11100001 137 00010001 138 10010001 139 01010001 140 11010001 141 00110001 142 10110001 143 01110001 144 11110001 145 00001001 146 10001001 147 01001001 148 ...

  • Pelco REL2064 - page 18

    18 C1518M-A (11/02) Figure 11. REL2064 Dimension Diagram 19.00 (48.26) PWR ALARM REL2064 Relay Interface Unit Made in USA 17.40 (44.20) 1.75 (4.45) 8.15 (20.70) NOTE: V ALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES 00695 SPECIFICA TIONS ELECTRICAL Input V oltage: 100-240 V AC, 50/60 Hz, auto-ranging Power: 30 V A Data Ports Diagnostic ...

  • Pelco REL2064 - page 19

    C1518M-A (11/02) 19 REVISION HISTORY Manual # Date Comments C1518M 5/01 Original version. C1518M-A 11/02 Updated manual to new format. Revised T able A and updated T able B. ® Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco. © Copyright 2002, Pelco. All rights reserved. REGULA TORY NOTICES ...

  • Pelco REL2064 - page 20

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada ® ...

Produzent Pelco Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts Pelco REL2064 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Pelco
- Bedienungsanleitungen REL2064
- Produktkarten Pelco
- Informationsbroschüren
- oder Energieetiketten Pelco REL2064
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Pelco REL2064.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Pelco REL2064, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Pelco REL2064. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Pelco REL2064 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Pelco REL2064, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Pelco REL2064 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Pelco REL2064 verständlich ist.

Eine gänzliche Bedienungsanleitung von Pelco sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Pelco REL2064 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Pelco REL2064 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Pelco REL2064, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Pelco REL2064 - die uns die ersten Schritte während der Nutzung von Pelco REL2064 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Pelco REL2064 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Pelco REL2064 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Pelco REL2064?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Pelco REL2064 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Pelco REL2064 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)