    7.5x9-inch cover with bleed on 4 sides Enterasys Matrix ® DFE-Platinum Series Hardware Installation Guide 7G4285-49 7G4205-72 P/N 9034160-03 ...

  • Enterasys Networks 7G4205-72 - page 2

    ...

  • Enterasys Networks 7G4205-72 - page 3

    i Notice Enterasys Networks  reserv es  the  right  to  make  changes  in  specif ications  and  other  info rmation  contained  in  this  document  and  its  web  site  without  prior  notice.  The  reader  should  in  all  cases  consult  Enterasy s Networks ...

  • Enterasys Networks 7G4205-72 - page 4

    ii Regulatory Compliance Information Federal Communications Commission (FCC) Notice This  device  com plies  with  Par t  15  of  th e  FCC  rules.  Operat ion  is  subject  to  the  foll owing  tw o  conditions:  (1)  this  device  may  not  cause  harmful  interference, ? ...

  • Enterasys Networks 7G4205-72 - page 5

    iii Electromagnetic Compatibility (EMC) This  product  complies  with  the  follo wing:  47  CFR  Par t s  2  and  15,  CSA  C108.8,  2004/108/EC,  EN  55022,  EN  61000 ‐ 3 ‐ 2,  EN 61000 ‐ 3 ‐ 3,  EN  55024,  AS/NZS  CISPR  22,  VCCI  V ‐ 3.  Compatibilidad ...

  • Enterasys Networks 7G4205-72 - page 6

    iv Enterasys  Customer  Support  at  353  61  705586  (Ireland). ѻ ѻ ક䇈ᯢк䰘ӊ Supplement to Product Instructions ᳝↦᳝ᆇ⠽䋼៪ܗ㋴ (Hazardous Substance) 䚼ӊৡ⿄ (Parts) 䪙 3E ∲ +J 䬝 &G ݁Ӌ䫀 &U   ໮⒈㘨㣃 3%% ໮⒈Ѡ㣃䝮  ...

  • Enterasys Networks 7G4205-72 - page 7

    v VCCI Notice This  is  a  class  A  product  based  on  the  standard  of  the  Vo l u n t a r y  Control  Co uncil  for  Interfe rence  by  Information  Te c h n o l o g y  Equipment  (VCCI).  If  this  equipmen t  is  used  in  a  domestic  environment,  ...

  • Enterasys Networks 7G4205-72 - page 8

    vi Safety Information Class 1 Laser Transceivers The single mode interface modules use Class 1 laser transceivers . Read the following safe ty information before installing or operating these m odules. The  Class  1  laser  transceivers  use  an  optical  feedback  loop  to  maintain  Class  1  operation ? ...

  • Enterasys Networks 7G4205-72 - page 9

    vii ENTERASYS NETWORKS, INC. FIRMWARE LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This  document  is  an  agreement  (“ Agreement”)  betwee n  the  end  user  (“Y o u”)  and  Enteras ys  Networks,  In c.,  on  behalf  of  its ...

  • Enterasys Networks 7G4205-72 - page 10

    viii 3. APPLICABLE  LAW. This  Agreem ent  shall  be  interpreted  and  governed  under  the  laws  and  in  the  state  and  federal  courts  of  th e  Commonwealth  of  Massachu setts  with out  regard  to  its  conflicts  of  laws  provis ions.  You  ...

  • Enterasys Networks 7G4205-72 - page 11

    ix 8. AUDIT  RIGHTS. You  here by  acknowled ge  that  the  intellectual  property  rights  associated  with  the  Program  are  of  critical  value  to  Enterasys,  and,  accordingly,  You  hereby  agree  to  maintain  complete  books,  re cords  and  account ...

  • Enterasys Networks 7G4205-72 - page 12

    x ...

  • Enterasys Networks 7G4205-72 - page 13

    xi Contents About This Guide Who Should Use This G uide .............. ....................... ....................... ......................... ................ .......... xv How to Use This Guide ................ ....................... ...................... ....................... ..................... ........ ..... xvi Related Documents ..... ...

  • Enterasys Networks 7G4205-72 - page 14

    xii Connecting to an IBM PC or Co mpatible Device .......... ...................... ....................... ................ 3-18 Connecting to a VT Series Term inal ...... ....................... ................... ....................... ................... 3- 19 Connecting to a Modem ........................ ....................... ............ ...

  • Enterasys Networks 7G4205-72 - page 15

    xiii Figures 1-1 7G4285-49 DFE-Platinum Modu le .......... ...................... ....................... ...................... ............ 1-3 1-2 7G4205-72 DFE-Platinum Modu le ......... ...................... ....................... ...................... ............ 1-5 3-1 Examples, Module Placement in Matrix E7 Chassis ............ ....... ...

  • Enterasys Networks 7G4205-72 - page 16

    xiv ...

  • Enterasys Networks 7G4205-72 - page 17

    Matrix DFE-Platinum Series PoE Hardware Installation Guide xv About This Guide This  guide  provides  an  ov erview ,  installation  and  troubleshooting  instructions,  and  specifications  for  the  Enterasys  Matr ix ®  7G4285 ‐ 49  and  7G4205 ‐ 72  DFE ‐ Platinum  Po E  modules ...

  • Enterasys Networks 7G4205-72 - page 18

    How to Use This Guide xvi About This Guide How to Use This Guide This  preface  provides  an  overview  of  this  guide  and  the  DFE ‐ Platinum  Series  manual  set,  and  a  brief  summary  of  each  chapter;  defines  the  conv entions  used  in  this  document; ...

  • Enterasys Networks 7G4205-72 - page 19

    Conventions Used in This Guide Matrix DFE-Platinum Series PoE Hardware Installation Guide xvii Conventions Used in This Guide The  following  conventions  are  used  in  this  guide. Lowercase  x:  Indicates  the  general  use  of  an  alphanumeric  character  (for  example,  7x2xx,  the ? ...

  • Enterasys Networks 7G4205-72 - page 20

    Getting Help xviii About This Guide Getting Help For  additional  support  related  to  the  modules  or  this  document,  contact  Enterasys Networks  using  one  of  the  following  metho ds: Before  contacting  Enterasys Networks  for  technical  support,  have  the  foll ...

  • Enterasys Networks 7G4205-72 - page 21

    DFE-Platinum Series Hardware Installation Guide 1-1 1 Introduction This  chapter  provides  an  overview  of  the  DFE ‐ Plati num  Series  module  capabilities,  and  introduces  the  7G 4285 ‐ 49  and  7G4205 ‐ 72  DFE ‐ Plat inum  Po E  modules. Overview of DFE-Platinum Series Modu ...

  • Enterasys Networks 7G4205-72 - page 22

    DFE Module and Interface Options 1-2 Introduction •H i g h ‐ av ailability  services  with  stateful  failover  for  services  and  management  •S e l f ‐ learning  configuration  modules  with  increased  reliability  and  fault  tolerance  that  reduces  configuration  time ? ...

  • Enterasys Networks 7G4205-72 - page 23

    DFE Module and Interface Options DFE-Platinum Series Hardware Installation Guide 1-3 Figure 1- 1 7G4285-49 DFE-Platinum Module 1 OFFLINE/RESET switch 7 GROUP ST A TUS LEDs 2 RJ45 COM port 8 GROUP SELECT LEDs 3 MGMT LED 9 NEM option slot 4 CPU LED 10 48 Vdc ~ 20 A Max. Optional Power Input 5 PoE LED connector 6 GROUP SELECT switch 11 Ports (1-48), 1 ...

  • Enterasys Networks 7G4205-72 - page 24

    DFE Module and Interface Options 1-4 Introduction 7G4205-72 The  7G4205 ‐ 72  has  72,  10BASE ‐ T/10 0BASE ‐ TX/1000BASE ‐ T,  PoE ‐ complia nt  ports  that  are  accessed  through  the  fixed  front  panel  RJ45  connectors.  The  DFE  module  can  be  installed  in ? ...

  • Enterasys Networks 7G4205-72 - page 25

    DFE Module and Interface Options DFE-Platinum Series Hardware Installation Guide 1-5 Figure 1-2 7G4205-72 DFE-Platinum Module 1 OFFLINE/RESET switch 6 GROUP LEDs 2 RJ45 COM port 7 GROUP SELECT button 3 CPU LED 8 GROUP status LEDs 4 MGMT LED 9 Groups 1&2, 40 ports, 10/100/1000 Mbps 5 Group 3, 20 ports, 10/100/1000 Mbps Â Ã Ä Å Æ Á À È Ç ...

  • Enterasys Networks 7G4205-72 - page 26

    Network Expansion Module (NEM) 1-6 Introduction Network Exp ansion Module (NEM) The  7G4285 ‐ 49  option  slot  provides  access  to  an  installed  network  expansion  module .  Refer  to  the  Enterasys Networks  webs ite  for  a  current  listing  of  the  available  NEMs. ...

  • Enterasys Networks 7G4205-72 - page 27

    Secure Networks Policy Support DFE-Platinum Series Hardware Installation Guide 1-7 Switch Configuration Using CLI Commands The  CLI  commands  enable  you  to  perform  more  complete  switch  configuration  management  tasks. For  CLI  command  set  information  and  how  to  configure ? ...

  • Enterasys Networks 7G4205-72 - page 28

    LANVIEW Diagnostic LEDs 1-8 Introduction LANVIEW Diagnostic LEDs LANVIEW  diagnostic  LEDs  serv e  as  an  important  troubleshooting  aid  by  providing  an  easy  wa y  to  observe  the  status  of  indivi dual  ports  and  overall  netw ork  operations. ...

  • Enterasys Networks 7G4205-72 - page 29

    DFE-Platinum Series Hardware Installation Guide 2-1 2 Network Requirements Before  inst alling  the  module,  review  the  requirements  and  specificat ions  referred  to  in  this  chapter  concerning  the  following: The  network  install ation  must  meet  the  requiremen ts  ...

  • Enterasys Networks 7G4205-72 - page 30

    Link Aggregation 2-2 Network Requirements Link Aggregation Link  Aggregation  is  a  method  of  grouping  multiple  physical  ports  on  a  network  device  into  one  logical  link  according  to  the  IEEE  802.3ad ‐ 2002  standard.  Because  Link  Aggregation  is ...

  • Enterasys Networks 7G4205-72 - page 31

    100BASE-TX Network DFE-Platinum Series Hardware Installation Guide 2-3 100BASE-TX Network The  fixed  front  panel  ports  of  the  7G4285 ‐ 49  and  7G4205 ‐ 72  provide  a  connection  that  supports  Category  5  UTP  cabling.  The  device  at  the  other  end  of  ...

  • Enterasys Networks 7G4205-72 - page 32

    1000BASE-T Network 2-4 Network Requirements ...

  • Enterasys Networks 7G4205-72 - page 33

    DFE-Platinum Series Hardware Installation Guide 3-1 3 Installation This  chapter  provides  the  instructions  to  install  the  7G4285 ‐ 49  and  7G4205 ‐ 72  DFE modules.  Follow  the  order  of  the  sections  listed  below  to  correctly  install  the  DFE modules. Elec ...

  • Enterasys Networks 7G4205-72 - page 34

    Installation Site Requirement 3-2 Installation Inst allation Site Requirement The  DFE modules  must  be  installed  in  a  Matrix  E7,  N3 ,  N5,  or  N7  chassis  located  in  a  Restricted  Access  Location  (RAL).  This  location  should  only  be  accessible  by ? ...

  • Enterasys Networks 7G4205-72 - page 35

    Installing an Optional Ne tw ork Expansion Module (NEM) DFE-Platinum Series Hardware Installation Guide 3-3 Inst alling an Optional Network Exp ansion Module (NEM) Refer  to  the  Enterasys Networks  web  site  for  a  cur rent  listing  of  the  av aila ble  NEMs.  Specific  installation  instruction ...

  • Enterasys Networks 7G4205-72 - page 36

    DFE Module Placement and Installation Rules 3-4 Installation Figure 3-1 Examples, Module Placement in Matrix E7 Chass is Example 1 ( Figure 3-1 , A) Shows  the  chassis  fully  po pulated  with  DFE modules  (7xxxxx).  These  modules  communicate  with  each  other  via  the  FTM2  chassis  back ...

  • Enterasys Networks 7G4205-72 - page 37

    DFE Module Placement and Installation Rules DFE-Platinum Series Hardware Installation Guide 3-5 Example 4 ( Figure 3-1 , D) Shows  chassis  slots  1  through  5  populated  wi th  a  mix  of  6x1xx,  6x2xx,  and  6x3xx  modules  and  only  third  generation  modules  in  slots  6 ...

  • Enterasys Networks 7G4205-72 - page 38

    Preparing to Install into a Chassis 3-6 Installation Prep aring to Install into a Chassis Before  installing  any  module  into  the  Matrix E7 chassi s,  refer  to  “ DFE  Module  Placement  and  Installation  Ru les ”  on  page 3 ‐ 3  to  familiarize  your se lf  with  the  F ...

  • Enterasys Networks 7G4205-72 - page 39

    Preparing to Install into a Chassis DFE-Platinum Series Hardware Installation Guide 3-7 5. Examine  the  module  for  dam age.  If  any  damage  exists,  DO  NOT  install  the  module.  Immediately  contact  Enterasys N etworks.  Refer  to  “ Getting  Help ”  on  page xviii. 6 ...

  • Enterasys Networks 7G4205-72 - page 40

    Preparing to Install into a Chassis 3-8 Installation 3. Align  the  module  card  between  the  upper  and  lower  card  guides  of  the  desired  slot  and  slide  it  into  the  chassis,  taking  care  that  the  module  slides  in  straight.  See  Caution ? ...

  • Enterasys Networks 7G4205-72 - page 41

    Preparing to Install into a Chassis DFE-Platinum Series Hardware Installation Guide 3-9 Figure 3-2 Installing Module into Matr ix E7 o r N7 Chassis (Matrix E 7 shown) 1 Card guides 7 Backplane connectors 2 Slot number 6 (Left-most slot is 1) • T op two connectors (power and FTM2 3 Module card • Bottom two connectors (power and FT M1) 4 Metal ba ...

  • Enterasys Networks 7G4205-72 - page 42

    Preparing to Install into a Chassis 3-10 Installation Inst alling the DFE Modules into a Matrix N3 or N5 Chassis A  DFE ‐ Platinum  module  can  be  installed  in  any  av ailable  N3  chassis  slot  (1  through  3).  To  install  a  module  into  the  Mat rix N3  chassis,  refe ...

  • Enterasys Networks 7G4205-72 - page 43

    Preparing to Install into a Chassis DFE-Platinum Series Hardware Installation Guide 3-11 4. Slide  the  module  into  the  slot  unt il  yo u  can  engage  the  top  and  bottom  locking  levers. 5. Refer  to  the  Caution  note  above,  then  rotate  the  two  lever s  i ...

  • Enterasys Networks 7G4205-72 - page 44

    Connecting 48 Vdc Power for PoE Operation 3-12 Installation Connecting 48 Vdc Power for PoE Operation The  Matri x N7  (7C105 ‐ P)  chassis  provides  48  Vdc  to  connecte d  PDs  (pow ered  devices)  by  wa y  of  its  backplane  connection  to  a  PoE ‐ compliant  DFE module such ...

  • Enterasys Networks 7G4205-72 - page 45

    Connecting to the Network DFE-Platinum Series Hardware Installation Guide 3-13 Connecting UTP Cabl es to DFE Modules The  fixed  RJ4 5  front  panel  connections  of  the  7G4285 ‐ 49  and  7G4205 ‐ 72  are  10/100/ 1000 Mbps  ports.  These  ports  have  inter nal  crossovers,  and  su ...

  • Enterasys Networks 7G4205-72 - page 46

    Connecting to the Network 3-14 Installation Figure 3-4 Connecting a T wisted Pair Segment with RJ45 Connector 3. V erify  that  a  link  ex ists  by  check ing  that  the  port  RX  (Receive)  LED  is  ON  (flashing  amber ,  blinking  green,  or  solid  green).  If  the  RX ? ...

  • Enterasys Networks 7G4205-72 - page 47

    Connecting to the Network DFE-Platinum Series Hardware Installation Guide 3-15 e. V erify  that  the  RJ45  connectors  on  the  twisted  pair  segment  hav e  the  proper  pinouts  and  check  the  cable  for  continuity .  Ty p i c a l l y ,  a  crossover  cable  is  used ...

  • Enterasys Networks 7G4205-72 - page 48

    Connecting to the Network 3-16 Installation Figure 3-7 Eight-Wire Crossover Cable RJ45 Pin outs , Connections Between Hub Devices Figure 3-8 Eight-Wire Straight -Throu gh Cable RJ45 Pinout s, Connections Between Switches and End User Devi ces 1 RJ45 device port 3 RJ45-to-RJ45 crossover cable 2 Other device port 1 RJ45 device port 3 RJ45-to-RJ45 str ...

  • Enterasys Networks 7G4205-72 - page 49

    Connecting to the Network DFE-Platinum Series Hardware Installation Guide 3-17 f. Ensure  that  the  twisted  pai r  connection  meets  the  dB  loss  and  cable  specifications  outlined  in  the  Cabling  Guide.  Refer  to  “Related  Documents”  in  About  This  Gui de ...

  • Enterasys Networks 7G4205-72 - page 50

    Connecting to COM Port for Local Management 3-18 Installation Connecting to COM Port for Local Management This  section  describes  how  to  install  a  UTP  straight ‐ through  cable  with  RJ45  connectors  and  optional  adapters  to  connect  a  PC,  a  VT  series  terminal, ...

  • Enterasys Networks 7G4205-72 - page 51

    Connecting to COM Port for Local Management DFE-Platinum Series Hardware Installation Guide 3-19 4. T u rn  on  the  PC  and  set  the  following  parameters  on  you r  VT  emulation  packag e: 5. When  these  parameters  are  set,  the  Local  Management  password  screen  will ...

  • Enterasys Networks 7G4205-72 - page 52

    Connecting to COM Port for Local Management 3-20 Installation 3. Connect  the  RJ45 ‐ to ‐ DB25  adapter  to  the  port  labeled  COMM  on  the  VT  terminal. 4. T u rn  on  the  terminal  to  access  the  Setup  Directory  and  set  the  following  parameters: When  ...

  • Enterasys Networks 7G4205-72 - page 53

    Connecting to COM Port for Local Management DFE-Platinum Series Hardware Installation Guide 3-21 2. Plug  the  RJ45  connector  at  the  other  end  of  the  UTP  straight ‐ through  cable  into  the  RJ45 ‐ to ‐ DB25  modem  adapter . 3. Connect  the  RJ45 ‐ to ‐ DB25  adapter ? ...

  • Enterasys Networks 7G4205-72 - page 54

    Connecting to COM Port for Local Management 3-22 Installation Adapter Wiring and Signal Assignment s COM Port Adapter Wir ing and Signal Diagram RJ45 DB9 Pin Conductor Pin Signal 1 Blue 2 Receive (RX) 4 Red 3 Transmit (TX ) 5 Green 5 Ground (GRD) 2 Orange 7 Request to Send (RTS) 6 Y ellow 8 Clear to Send (CTS) VT Series Port Adapter W iring and Sig ...

  • Enterasys Networks 7G4205-72 - page 55

    Connecting to COM Port for Local Management DFE-Platinum Series Hardware Installation Guide 3-23 Modem Port Adapter Wiring and Sig nal Diagram RJ45 DB25 Pin Conductor Pin Signal 1 Blue 2 T ransmit (TX) 2 Orange 8 Data Carrier Detect (DCD) 4 Red 3 Receive 5 Green 7 Ground (GRD) 6 Y ellow 20 Data T erminal Ready (DTR) 8 Gray 22 Ring Indicator 6 9 DB9 ...

  • Enterasys Networks 7G4205-72 - page 56

    Completing the Installation 3-24 Installation Completing the Inst allation Completing  the  DFE module  installation  depends  on  whether  the  module  is  being  installed  in: •a  new  DFE module  system  (refer  to  “ Completing  the  Installation  of  a  New  System ? ...

  • Enterasys Networks 7G4205-72 - page 57

    Completing the Installation DFE-Platinum Series Hardware Installation Guide 3-25 The  module  is  now  ready  to  be  configured.  For  information  about  set ting  the  IP  address  and  configuring  Te l n e t  settings  for  remote  access  to  DFE  management,  refer ? ...

  • Enterasys Networks 7G4205-72 - page 58

    Completing the Installation 3-26 Installation Completing the Inst allation of a DFE Mo dule in an Existing System In  an  established  DFE module  system, •a  DFE module  is  already  established  as  the  management  module, •t h e  passwords  hav e  alrea dy  been  set  for  var io us ? ...

  • Enterasys Networks 7G4205-72 - page 59

    DFE-Platinum Series Hardware Installation Guide 4-1 4 T roubleshooting This  chapter  provides  information  concerning  the  following: Using LANVIEW The  DFE  module  uses  a  built ‐ in  visual  diagnostic  and  status  monitoring  system  called  LANVIEW .  The  LANVIEW  LEDs ? ...

  • Enterasys Networks 7G4205-72 - page 60

    Using LANVIEW 4-2 Troubleshooting V iewing Receive/T ransmit Activity on 7G4285-49 Yo u  can  view  the  7G4285 ‐ 49  receive  and  trans mit  port  activity  on  the  RX  and  TX  LEDs.  Howeve r ,  only  one  group  of  12  ports  may  be  view ed  at  a  time. ...

  • Enterasys Networks 7G4205-72 - page 61

    Using LANVIEW DFE-Platinum Series Hardware Installation Guide 4-3 V iewing Receive/T ransmit Activity on 7G4205-72 On  the  7G4205 ‐ 72,  you  can  view  the  rec eive  and  transmit  activity  on  the  RX  and  TX  LEDs.  Howeve r ,  only  one  group  of  24  ports  may  ...

  • Enterasys Networks 7G4205-72 - page 62

    Using LANVIEW 4-4 Troubleshooting V iewing the PoE Port St atus If  the  7G4285 ‐ 49  or  7G4205 ‐ 72  is  installed  in  an  N5  chassis  or  if  the  7G4285 ‐ 49  is  receiving  48  Vdc  from  an  external  N ‐ POE  Po we r  System  to  support  connections ? ...

  • Enterasys Networks 7G4205-72 - page 63

    Using LANVIEW DFE-Platinum Series Hardware Installation Guide 4-5 T able 4-1 LANVIEW LEDs LED Color State Recommended Action MGMT Off Off . This DFE module is NOT the Management Module. None. Green Solid . This module is the designated Manag ement Module. None. Amber Flas hing . This is a temporary indication t hat the DFE module is saving data. No ...

  • Enterasys Networks 7G4205-72 - page 64

    Using LANVIEW 4-6 Troubleshooting RX/TX Indications in S ta ndard Mode RX (Receive) Off No link . No activity . Port enabled or disabled. None. Green Solid . Link present, port enabled, no traffic is being received by the interface. None. Amber Flashing . Link present, port enabled, traffic is being received by the interface. None. Red Blinking . I ...

  • Enterasys Networks 7G4205-72 - page 65

    Using LANVIEW DFE-Platinum Series Hardware Installation Guide 4-7 RX/TX LED Indications in PoE Port S ta tus Mode RX/TX Green/Of f There is a connecti on to a PD. There is 48 Vdc at the RJ45 connector . None. Off/Red Port is off due to overload. The attached device exceeded maximu m load according to 802.3 af standard PoE device power classificatio ...

  • Enterasys Networks 7G4205-72 - page 66

    Troubleshooting Checklist 4-8 Troubleshooting T roubleshooting Checklist If  the  module  is  not  work in g  properly ,  refer  to  Ta b l e 4 ‐ 2  on  page 4 ‐ 8  for  a  checklist  of  problems,  possible  causes,  and  recommended  actions  to  resolv e  the  problem ...

  • Enterasys Networks 7G4205-72 - page 67

    Troubleshooting Checklist DFE-Platinum Series Hardware Installation Guide 4-9 Cannot contact the module through in- band management. IP address not assigned. Refer to the Enterasys Matrix DFE- Platinum Series Configurati on Guide for the IP address assignment proce dure. Port is disab led. Enable port. Refe r to the Enterasys Matrix DFE-Platinum Se ...

  • Enterasys Networks 7G4205-72 - page 68

    Overview of DFE Module Shutdown Procedure 4-10 Troubleshooting Overview of DFE Module Shut down Procedure The  DFE  mo dules  ins talled  in  a  Mat rix  E7,  Matrix  N3,  Matrix  N5,  or  Matrix  N7  chassis  are  interdependent  and  operate  unde r  a  single  IP  address ? ...

  • Enterasys Networks 7G4205-72 - page 69

    Overview of DFE Module Shutdown Procedure DFE-Platinum Series Hardware Installation Guide 4-11 Figure 4-3 OFFLINE/RESET S witch Recommended Shut down Procedure Using OFFLINE/RESET Switch Before  pulling  a  DFE  module  out  of  a  chassis,  press  or  tap  on  its  OFFLINE /RESET  switch  for  les ...

  • Enterasys Networks 7G4205-72 - page 70

    Overview of DFE Module Shutdown Procedure 4-12 Troubleshooting Last Resort Shut down Proced ure Using OFFLINE/RESET Switch To  reset  a  DFE  module  without  it  performing  an  orderly  shutdown  routine,  press  and  ho ld  the OFFLINE/RESET  switch  for  approximately  6  seconds.  ...

  • Enterasys Networks 7G4205-72 - page 71

    DFE-Platinum Series Hardware Installation Guide A-1 A Specifications This  appendix  provides  information  about  the  foll owing: Enterasys Networks  reserves  the  right  to  change  the  specifications  at  any  time  without  notice. For information about... Refer to p age... DFE Module S p ...

  • Enterasys Networks 7G4205-72 - page 72

    DFE Module Specifications A-2 Specifications DFE Module S pecifications Ta b l e A ‐ 1  provides  the  Input/Output  ports,  processors  and  memory ,  physical,  and  environmental  modul e  specific ations  for  the  7G4285 ‐ 49  DFE module.  Ta b l e A ‐ 2  provides  the  same  ...

  • Enterasys Networks 7G4205-72 - page 73

    DFE Module Specifications DFE-Platinum Series Hardware Installation Guide A-3 T able A-2 7G4205-72  S pecifications Item Specification Ports 1 through 72 Seventy-two, 10BASE-T/100BASE-TX /1000BASE-T ports by way of RJ45 connectors. These ports also support PoE operation. Processors/Memo ry Processor MPC750CX, 400 MHz processor Dynamic Random Acc ...

  • Enterasys Networks 7G4205-72 - page 74

    COM Port Pinout Assignments A-4 Specifications COM Port Pinout Assignment s The  COM  port  is  a  serial  communications  port  for  loc al  access  to  Local  Management.  Refer  to  Ta b l e A ‐ 3  for  the  COM  port  pin  assi gnments. Regulatory Compliance The  7G4285 ‐ ...

  • Enterasys Networks 7G4205-72 - page 75

    DFE-Platinum Series Hardware Installation Guide B-1 B Mode Switch Settings and Option Installations This  appendix  covers  the  following  items: Required T ools Use  the  following  tools  to  perform  the  procedures  provided  in  this  appendix: •A n t i s t a t i c  wrist  stra p • Phi ...

  • Enterasys Networks 7G4205-72 - page 76

    Setting the Mode Switches B-2 Mode Switch Settings and Option Installations Setting the Mode Switches Figure B ‐ 1  shows  the  location  of  the  mode  switches  and  the  switch  settings  for  nor mal  operation.  These  switches  are  set  at  the  factory  and  rarel y  ...

  • Enterasys Networks 7G4205-72 - page 77

    Memory Locations and Replacement Procedures DFE-Platinum Series Hardware Installation Guide B-3 Figure B-1 Mode Switch Location (7G4285-49 shown without safety cover) Memory Locations and Replacement Procedures If  the  Dual  In ‐ line  Memory  Modul e  (DIMM)  or  DRAM  Single  In ‐ line  Memory  Module  ...

  • Enterasys Networks 7G4205-72 - page 78

    Memory Locations and Replacement Procedures B-4 Mode Switch Settings and Option Installations Figure B-2 DIMM and DRAM SIMM Locations (7G4285-49 shown without sa fety cover) 1 DRAM SIMM 2 DIMM 3 Main PC board ...

  • Enterasys Networks 7G4205-72 - page 79

    Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Guide B-5 Gaining Access to Memory Modules Before  you  can  replace  the  DRAM  SIMM,  you  must  gain  access  to  it  by  removing  the  safety  cover  and  the  network  expansion  module,  if  one ? ...

  • Enterasys Networks 7G4205-72 - page 80

    Gaining Access to Memory Modules B-6 Mode Switch Settings and Option Installations Figure B-3 Removing the Safety Cover 1 Safety cover 3 S tandoffs (7) 2 Cover screws (7) 4 S tandoff/spacer screwed to st andoff under expansion module ...

  • Enterasys Networks 7G4205-72 - page 81

    Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Guide B-7 DRAM SIMM Replacement Procedure After  you  have  removed  the  safety  cov er  as  described  in  “ Removi ng  the  Safety  Cover ”  on  page B ‐ 5,  proceed  to  “ Removing  the  Optional  Net ...

  • Enterasys Networks 7G4205-72 - page 82

    Gaining Access to Memory Modules B-8 Mode Switch Settings and Option Installations 2. Remove  the  tw o  screws  fastenin g  the  netw ork  expansion  module  to  the  DFE module  front  panel  and  remov e  the  standoff  fastening  the  network  expansion  module  to  the  ...

  • Enterasys Networks 7G4205-72 - page 83

    Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Guide B-9 Removing the DIMM To  remov e  the  DIMM,  refer  to  Figu re B ‐ 5  and  proceed  as  follows. 1. Refer  to  Figure B ‐ 5 .  Push  the  connector  arms  aw ay  from  the  DIMM  to  release  i ...

  • Enterasys Networks 7G4205-72 - page 84

    Gaining Access to Memory Modules B-10 Mode Switch Settings and Option Installations 4. Reinstall  the  safety  cover .  Refer  to  “ Reinstalling  the  Safety  Cov er ”  on  page B ‐ 14  for  instructions. Figure B-6 I nst alli ng the DIMM DIMM Replacement Procedure In  the  event  that  the ...

  • Enterasys Networks 7G4205-72 - page 85

    Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Gu ide B-11 3. Push  the  connector  arms  aw a y  from  the  DIMM,  as  shown  in  Figure B ‐ 7 ,  and  simultaneously  lift  the  DIMM  enough  to  release  it  from  the  connector  fingers. Figure ...

  • Enterasys Networks 7G4205-72 - page 86

    Gaining Access to Memory Modules B-12 Mode Switch Settings and Option Installations Figure B-8 I nst alli ng the DIMM Inst alling the Network Ex pa nsion Module (NEM) Refer  to  Figure B ‐ 9  and  proceed  as  follows: 1. P osition  the  network  expansion  module  so  its  front  panel  is  under ? ...

  • Enterasys Networks 7G4205-72 - page 87

    Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Gu ide B-13 Figure B-9 In st a lling the Network Ex p ans ion Module (NEM ) 3. Use  two  of  the  saved  cov erplate  screws  to  fasten  the  network  expansion  module  to  the  DFE module  front  panel,  but  do  ...

  • Enterasys Networks 7G4205-72 - page 88

    Gaining Access to Memory Modules B-14 Mode Switch Settings and Option Installations Reinst alling the Safety Cover To  install  the  safety  cover ,  refer  to  Figure B ‐ 10  and  proceed  as  follows: 1. Locate  the  seven  screw s  saved  in  the  procedure  “ Removing  the  Safe ...

  • Enterasys Networks 7G4205-72 - page 89

    Gaining Access to Memory Modules DFE-Platinum Series Hardware Installation Gu ide B-15 Figure B-10 Installing the Safet y Cover 1 Safety cover 2 Screws (7) 3 S tandoff (7) ...

  • Enterasys Networks 7G4205-72 - page 90

    Gaining Access to Memory Modules B-16 Mode Switch Settings and Option Installations ...

  • Enterasys Networks 7G4205-72 - page 91

    DFE-Platinum Series Hardware Installation Guide C-1 C About PoE (Power over Ethernet) This  appendix  provides  an  overview  of  Pow e r  over  Ethernet  T echnology  and  how  it  is  implemented  in  relation  to  the  7G4285 ‐ 49  and  7G4205 ‐ 72  DFE  modules. Overview P ...

  • Enterasys Networks 7G4205-72 - page 92

    Overview C-2 About PoE (Power over Ethernet) Propriet ary PD Detection The  7G4285 ‐ 49  and  7G4205 ‐ 72  support  a  subset  of  the  currently  deploy ed  proprietary  PoE  methods.  This  includes  support  for  Cisco  PDs,  including  a  proprietary  capacitor  based ? ...

  • Enterasys Networks 7G4205-72 - page 93

    Overview DFE-Platinum Series Hardware Installation Guide C-3 PoE Port St atus LEDs The  Po E  port  status  of  each  10/100/100 0  Mbps  front ‐ panel  port  is  indicated  by  the  two ‐ color  RX  and  TX  LED  display  for  each  port.  To  observe  the  Po E  ...

  • Enterasys Networks 7G4205-72 - page 94

    Overview C-4 About PoE (Power over Ethernet) ...

  • Enterasys Networks 7G4205-72 - page 95

    Index-1 Index Numerics 100BASE-TX requirements 2-3 10BASE-T connection 3-13 requirements 2-2 7G4205-72 introduction to 1-4 , 1-5 specifications for A-3 7G4285-49 introduction to 1-2 , 1-3 specifications for A-2 C Cable connections 7G4205-72 3-13 7G4285-49 3-13 UTP 3-13 Cable specifications 100BASE-TX network 2-3 10BASE-T network 2-2 CLI command int ...

  • Enterasys Networks 7G4205-72 - page 96

    Index-2 Module coverplate removal of B-7 Module features 1-2 , 1-4 N NEM B-12 installing 1-6 Network connecting to 3-12 Network Expansion Module 1-6 Network expansion module installation of B-12 Network Requirements list of 2-1 O Offline/reset switch use of 4-1 1 Optional netw ork expansion module installation of 3-3 P Pinout assignments console po ...

Produzent Enterasys Networks Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Enterasys Networks 7G4205-72 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Enterasys Networks
- Bedienungsanleitungen 7G4205-72
- Produktkarten Enterasys Networks
- Informationsbroschüren
- oder Energieetiketten Enterasys Networks 7G4205-72
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Enterasys Networks 7G4205-72.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Enterasys Networks 7G4205-72, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Enterasys Networks 7G4205-72. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Enterasys Networks 7G4205-72 ansehen.

Die komplette Bedienungsanleitung des Geräts Enterasys Networks 7G4205-72, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Enterasys Networks 7G4205-72 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Enterasys Networks 7G4205-72 verständlich ist.

Eine gänzliche Bedienungsanleitung von Enterasys Networks sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Enterasys Networks 7G4205-72 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Enterasys Networks 7G4205-72 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Enterasys Networks 7G4205-72, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Enterasys Networks 7G4205-72 - die uns die ersten Schritte während der Nutzung von Enterasys Networks 7G4205-72 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Enterasys Networks 7G4205-72 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Enterasys Networks 7G4205-72 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Enterasys Networks 7G4205-72?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Enterasys Networks 7G4205-72 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Enterasys Networks 7G4205-72 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen