  • FMI CGMFN - page 1

    For more information, visit www .fmiproducts.com W ARNING: If the information in this manual is not fol-           ? ...

  • FMI CGMFN - page 2

    www .fmiproducts.com 1 19315-01D 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Local Codes......................................................... 4 Unpacking............................................................ 4 Product Identication ........................................ ...

  • FMI CGMFN - page 3

    www .fmiproducts.com 1 19315-01D 3         Early sign s of carb on mo noxi de poi soni ng res embl e the  u, w ...

  • FMI CGMFN - page 4

    www .fmiproducts.com 1 19315-01D 4 SAFETY INFORMA TION Continued 17. Operating replace above elevations of 4,500 feet could cause pilot outage. 18 . Do not operate fireplace if any log is broken. Do not operate replace if a log is chipped (dime-sized or larger). 19. T o prevent performance problems, do not use propane/LP fuel tank of less tha ...

  • FMI CGMFN - page 5

    www .fmiproducts.com 1 19315-01D 5 PRODUCT IDENTIFICA TION Piezo Ignitor Screen Access Door Log Control Knob Figure 1 - V ent-Free Mini Compact Fireplace PRODUCT FEA TURES  This replace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free r ...

  • FMI CGMFN - page 6

    www .fmiproducts.com 1 19315-01D 6 Screen Shoulder Screw Figure 3 - Assembling Hood Figure 2 - Removing and Replacing Screen AIR FOR COMB USTION AND VENTILA TION             -  ...

  • FMI CGMFN - page 7

    www .fmiproducts.com 1 19315-01D 7 Th e air tha t leak s arou nd do ors a nd win do ws may provide enough fresh air for combus - ti on and ven ti lat io n. How eve r , in buil di ngs of un us ual ly tig ht co nst ruct io n, you mus t pr ov ide additional fresh air .    ...

  • FMI CGMFN - page 8

    www .fmiproducts.com 1 19315-01D 8 The space in the example is a conned space because the actual Btu/Hr used is more than the maximu m Bt u/Hr the space can sup port. Y o u must provide additional fresh air . Y our options are as follows: A. Rewo rk w orksh eet, addi ng the spa ce of an adj oin in g room . If the extr a spac e prov ide s an unco ...

  • FMI CGMFN - page 9

    www .fmiproducts.com 1 19315-01D 9 INST ALLA TION NOTICE: This heater is intended            ...

  • FMI CGMFN - page 10

    www .fmiproducts.com 1 19315-01D 10 INST ALLA TION Continued  W ARNING: Maintain the minimum clearances shown            ? ...

  • FMI CGMFN - page 11

    www .fmiproducts.com 1 19315-01D 11 INST ALLA TION Continued Actual Framing Height 23 3 / 4 " 22 1 / 4 " Front Width 19 3 / 4 " 17 1 / 2 " Depth 8 7 / 8 " 8 7 / 8 " Bottom 0" 0" 1. Fr am e in ro ug h op en in g. Use dim en si on s shown in Figure 7 for the rough opening. If installi ng in a corner, use dimens ...

  • FMI CGMFN - page 12

    www .fmiproducts.com 1 19315-01D 12 INST ALLA TION Continued Mantel Shelf 3 1 / 4 " 6" 9" 18" 3/4" 1" 3" 9" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches. Figure 9 - Minimum Mantel Clearances for Built-In Installation ? ...

  • FMI CGMFN - page 13

    www .fmiproducts.com 1 19315-01D 13 INST ALLA TION Continued        -         ? ...

  • FMI CGMFN - page 14

    www .fmiproducts.com 1 19315-01D 14 INST ALLA TION Continued We recommend that you install a sediment trap in supply line as shown in Figure 14. Lo - cat e se dime nt t rap whe re i t is wit hin reac h fo r cle ani ng. Inst all in pipin g syste m betwee n fuel supply and heater . Locate sediment trap where trapped matter is not likely to freeze. A ...

  • FMI CGMFN - page 15

    www .fmiproducts.com 1 19315-01D 15 INST ALLA TION Continued            and connections, internal and external to unit, for leaks after   ? ...

  • FMI CGMFN - page 16

    www .fmiproducts.com 1 19315-01D 16 INST ALLA TION Continued  CONNECTIONS 1. Op en eq uipm ent sh ut of f va lve (s ee Fi gur e 16, page 15). 2. Open main gas valve located on or near gas meter for natural gas or open pro - pane/LP supply tank valve. 3. Mak ...

  • FMI CGMFN - page 17

    www .fmiproducts.com 1 19315-01D 17 INST ALLA TION Continued       W ARNING: Read and fol -   ? ...

  • FMI CGMFN - page 18

    www .fmiproducts.com 1 19315-01D 18    W ARNING: Read and fol -    ? ...

  • FMI CGMFN - page 19

    www .fmiproducts.com 1 19315-01D 19 OFF PILOT ON OPERA TING FIREPLACE Continued                       ...

  • FMI CGMFN - page 20

    www .fmiproducts.com 1 19315-01D 20 OPERA TING FIREPLACE Continued                to ? ...

  • FMI CGMFN - page 21

    www .fmiproducts.com 1 19315-01D 21 OPERA TING FIREPLACE Continued                                             ? ...

  • FMI CGMFN - page 22

    www .fmiproducts.com 1 19315-01D 22                  -      ...

  • FMI CGMFN - page 23

    www .fmiproducts.com 1 19315-01D 23 INSPECTING B URNERS Check pilot ame pattern and burner ame patterns often.    Fi gu re 30 sho ws a cor rect pilo t am e pat tern . Fi gu re 31 sh ows an in co rr ec t p il ot a me pa t - te rn . T he inc orre ct pi lot am e i s no t tou chi n ...

  • FMI CGMFN - page 24

    www .fmiproducts.com 1 19315-01D 24 CLEANING AND MAINTENANCE               -     ? ...

  • FMI CGMFN - page 25

    www .fmiproducts.com 1 19315-01D 25 CLEANING AND MAINTENANCE Continued TROUBLESHOO TING                  ...

  • FMI CGMFN - page 26

    www .fmiproducts.com 1 19315-01D 26 TROUBLESHOO TING Continued  When ignito r butto n is press ed, there is spark at ODS/pilot but no ignition ODS/pilot lights but flame goes out when con trol knob is released Burner does not light after ODS/pilot is lit  1. G ...

  • FMI CGMFN - page 27

    www .fmiproducts.com 1 19315-01D 27 TROUBLESHOO TING Continued  Delayed ignition of burner Burner backring during com - bustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit White powder residue forming within burner box or on adja- cent walls ...

  • FMI CGMFN - page 28

    www .fmiproducts.com 1 19315-01D 28          ? ...

  • FMI CGMFN - page 29

    www .fmiproducts.com 1 19315-01D 29 SPECIFICA TIONS SERVICE HINTS   • pilot will not stay lit • burners will have delayed ignition • replace will not produce specied heat • for propane/LP units, propane/LP gas sup - ply may be low Yo u may fee l y ou r ...

  • FMI CGMFN - page 30

    www .fmiproducts.com 1 19315-01D 30 1 2 3 4 4 1 42 41 3 39 4 32 15 16 20 41 41 41 29 26 27 30 14 28 34 23 33 38 21 22 31 43 17 25 36 40 35 40 15 16 24 34 19 18 5 6 7 8 9 34 1 1 13 10 37 12 ILL USTRA TED P ARTS BREAKDOWN   ...

  • FMI CGMFN - page 31

    www .fmiproducts.com 1 19315-01D 31       1 1 18596-01 T op Panel • • 1 2 1 18573-01CK T op T rim Panel • • 1 3 1 18574-01 Heat Deector • • 1 4 1 18576-01CK Screen Assembly • • 1 5 1 18577-01CK Access Door • • 1 6 1 18578-01CK Side Panel T ...

  • FMI CGMFN - page 32

    www .fmiproducts.com 1 19315-01D 32 1 2 34 33 31 33 3 39 4 32 15 16 33 33 33 27 30 14 28 29 26 33 38 25 24 36 40 5 22 40 15 16 19 34 20 41 18 23 17 21 6 7 35 9 34 1 1 13 10 37 12 8 ILL USTRA TED P ARTS BREAKDOWN   AA Battery Positive UP AAA Batt ...

  • FMI CGMFN - page 33

    www .fmiproducts.com 1 19315-01D 33 P ARTS LIST REMOTE-READY MODELS This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.       1 1 18596-01 T op Panel ...

  • FMI CGMFN - page 34

    www .fmiproducts.com 1 19315-01D 34 ACCESSORIES NOTICE: All accessories may        Purchase these replace accessories from your lo cal deal er. If they can not su pply the se accessories, call F MI PR ODU CTS, LLC at 1-86 6- ...

  • FMI CGMFN - page 35

    www .fmiproducts.com 1 19315-01D 35 NO TES _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _________________________________ ...

  • FMI CGMFN - page 36

    1 19315-01 Rev . D 03/10 WARRANTY KEEP THIS WARRANTY FMI PRODUCTS, LL C LIMITED WARRANTIES  Standard Warranty: FM I PR O D UC TS , LL C w ar ra nt s th i s ne w pr od u ct an d an y pa rt s th e re of to b e fr ee fr o m de fe ct s i n ma te ri a l an d wo rk ma ns hi p f or a p er io d o f f ou r (4 ) ye a r s f ...

Produzent FMI Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts FMI CGMFN erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen FMI
- Bedienungsanleitungen CGMFN
- Produktkarten FMI
- Informationsbroschüren
- oder Energieetiketten FMI CGMFN
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung FMI CGMFN.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen FMI CGMFN, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen FMI CGMFN. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts FMI CGMFN ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts FMI CGMFN, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von FMI CGMFN hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von FMI CGMFN verständlich ist.

Eine gänzliche Bedienungsanleitung von FMI sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von FMI CGMFN bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von FMI CGMFN befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich FMI CGMFN, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts FMI CGMFN - die uns die ersten Schritte während der Nutzung von FMI CGMFN erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit FMI CGMFN hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von FMI CGMFN im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich FMI CGMFN?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit FMI CGMFN nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit FMI CGMFN hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)