    Reduced wiring system EX250 - SEN1 Instruction Manual EtherNet/IP™ Compatible SI Unit URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherNet/IP™ is a trademark used under licence by ODVA. The descriptions of products shown in this document may be used b ...

  • Sierra Monitor Corporation EX250-SEN1 - page 2

    Contents Thank you for purchasing the SMC reduced wiring system EX250 series. Please read this instruction manual carefully and understand the contents before use so that you can operate this unit safely and correctly. Please keep this manual handy for future reference. OPERA T OR This instruction manual has been written for those who ha ve kno wle ...

  • Sierra Monitor Corporation EX250-SEN1 - page 3

    2 3 SAFETY The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling. Please check that you fully understand the definitions of the following messages ( symbols ) before going on to read the body of this manual, and always follow ...

  • Sierra Monitor Corporation EX250-SEN1 - page 4

    4 5 Pr oduct Summar y Power supply for Output Block (for high wattage load) 24VDC Connecting to bus at upper level (EtherNet/IP) Power supply for output/input and control 24VDC Solenoid valve Output Block (for high wattage load) Power Block Output Block (for low wattage load) SI Unit applicable to EtherNet/IP Input Block End Plate This system reali ...

  • Sierra Monitor Corporation EX250-SEN1 - page 5

    6 7 SI Unit Model Indication Method Ti e-rod (2 pcs.) Accessory Note1 : For wiring method, refer to subsection "Wiring" (page 12) in this manual. Note2 : For display and setting method, refer to subsection "Display/Setting" (page 15) in this manual. Dimensions ( unit : mm ) BUS BUS PWR PWR SOL SOL NS NS PWR PWR SETTINGS SETTINGS ...

  • Sierra Monitor Corporation EX250-SEN1 - page 6

    8 9 Mounting/Installation (continued ) Layout of the Input Block Position the Input Block on the left side of the SI Unit. Layout of the EX9 series Output Block / Power Block Position the Output Block / Power Block on the right side of the SI Unit and between the SI Unit and solenoid valve or End Plate R (on the Output Block side). 1) Output Block ...

  • Sierra Monitor Corporation EX250-SEN1 - page 7

    10 11 Specifications Sensor input area 1 0 I/O mapping Offset (word) Input data MSB LSB MSB LSB 15 8 70 0 1 Input area mapping 15 14 L : Fixed to Low Item Status Condition SP Solenoid power supply status 0 No supply voltage 1 Supply voltage OK DI Status of sensor power supply 0 Short circuit 1 Normal Diagnostics (Status input area) 2 LL LL LL LL L ...

  • Sierra Monitor Corporation EX250-SEN1 - page 8

    12 13 Wiring 43 2 1 1 34 2 M12 1 2 +Rx 3 - Tx 4 - Rx 1 2 3 4 5 6 7 8 Shield RJ45 6.7 47.3 45 2000 Model No. : EX9-AC020EN-PSRJ +Tx Wiring diagram Cable core wire external color Terminal No. Pin assignment of plug connector Pin assignment of plug connector White/Orange Orange White/Green Green 8 7 6 5 4 3 2 1 Connect the Power Supply Cable to the po ...

  • Sierra Monitor Corporation EX250-SEN1 - page 9

    14 15 Wiring ( continued ) 24VDC 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blue : 24VDC (for input and control) Black : 0V (for input and control) Cable P ar t No . : EX500-AP -S 24VDC Brown : 24VDC (for solenoid valv es/output) White : 0V (for solenoid valv es/output) Grey : Ear th Blu ...

  • Sierra Monitor Corporation EX250-SEN1 - page 10

    16 17 12345678 ON 1 0 IP address 192.168.0.X 1 0 1 0 1 0 1 2 0 0 1 1 1 1 3 0 0 0 0 1 1 4 0 0 0 0 1 1 Remote control * 1 X 3 2 1 14 DHCP mode * 2 SW1 Communication setting CLEAR/HOLD Manual set up of IP address * 3 SW1 5 0 1 1 1 1 1 6 - - 0 1 - - 7 - - - - 0 1 SW1 Item Communication setting Communication speed Communication method Contents AUTO : Th ...

  • Sierra Monitor Corporation EX250-SEN1 - page 11

    18 19 Input Bloc k Model Indication Method EX250 IE Block type 1 2 3 Input points : 2, M12 connector (2pcs.) Input points : 4, M12 connector (2pcs.) Input points : 4, M8 connector (4pcs.) Input Block Model indication method Pa rt Names No. Part names Application 1 Input equipment connector Connects the input equipment such as sensor, etc. Note1 2 O ...

  • Sierra Monitor Corporation EX250-SEN1 - page 12

    20 21 Wiring EX250-IE3 EX250-IE1/2 EX250-IE1 (M12 connector, 5 pin, Socket) EX250-IE2 (M12 connector, 5 pin, Socket) *1) Input No.1 is connected to the pin No.2 of the input connector "0", 2 input signals can be directly input from the input connector "0". *2) NC : Not connected EX250-IE3 (M8 connector, 3 pin, Socket) 1 1 2 2 3 ...

  • Sierra Monitor Corporation EX250-SEN1 - page 13

    22 23 Displa y/Setting EX250-IE1 EX250-IE2/IE3 0 0 1 1 EX250 EX250 0 0 1 1 2 2 3 3 EX250 EX250 Display Description PWR Lights up Power supply for sensor is ON. Off Power supply for sensor is OFF. 0, 1, 2, 3 Lights up Sensor signal input corresponding to the number is ON. (Logic "1") Off Sensor signal input corresponding to the number is O ...

  • Sierra Monitor Corporation EX250-SEN1 - page 14

    24 25 Pa rt Names T ie-rod (2 pcs.) Accessory T ie-rod (2 pcs.) Accessory W aterproof cap (for socket)(1 pc.) Dimensions ( unit : mm ) 59.8 72.6 21 Output Block 59.8 80.3 21 PWR PWR Po wer Bloc k Mounting/Installation Refer to subsection "Mounting/Installation" (page 7) in this manual. Specifications Model No. EX9-OET1 EX9-OEP1 Power supp ...

  • Sierra Monitor Corporation EX250-SEN1 - page 15

    26 27 Wiring ( continued ) Output connector pin lay out EX9-OET1, EX9-OEP1 (M12 connector, 5 pin, Socket) Output No.1 *1 Output No.0 NC *2 1 NC *2 3 GND 5 NC *2 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5 Output connector "0" Output connector "1" Output wiring Cable wiring Pin alignment and connection drawing of the Output Cable Plu ...

  • Sierra Monitor Corporation EX250-SEN1 - page 16

    28 29 Wiring ( continued ) M12 connector, 5 pin, Reverse key 1 Power supply for output (24VDC) 2 Power supply for output (0VDC) 5 Ground ( 3 Power supply for sensor (24VDC)) * ( 4 Power supply for sensor (0V)) * 4 4 1 1 4 4 1 1 2 2 3 3 2 2 3 3 5 5 5 5 Power supply connector (Socket) Power input connector (Plug) * It is used when power is supplied t ...

  • Sierra Monitor Corporation EX250-SEN1 - page 17

    30 31 Wiring ( continued ) Displa y Output Block PWR PWR Po wer Bloc k The Power Supply Cable (for Power Supply Connector of Power Block) is a bypass cable which can be used when the Power Block is positioned next to the SI Unit. Option EX500 - AP 050 - S How to order Cable length (L) Connector specification 010 1 [m] 050 5 [m] S Straight EX9 - AC ...

  • Sierra Monitor Corporation EX250-SEN1 - page 18

    32 33 Option ( continued ) Waterproof Cap Mounted on the unused ports of the Input Block, Output Block and Power Block. The proper use of this Waterproof Cap can achieve IP67 Enclosure. (The Waterproof Caps are delivered together with the Power Block as accessories.) 9 EX500 - AW How to order Connector specification ES M8 connector ( for socket ) / ...

  • Sierra Monitor Corporation EX250-SEN1 - page 19

    34 Tr oubleshooting ( continued ) MS LED status Normal status : Green light ON Fatal failure : Red light ON 1 The effect of noise is possible. Check the installation conditions. If the trouble cannot be solved even if the installation conditions are checked, contact our sales branch. NS LED status Offline/Power is OFF : Light OFF Online/Communicati ...

Produzent Sierra Monitor Corporation Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts Sierra Monitor Corporation EX250-SEN1 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sierra Monitor Corporation
- Bedienungsanleitungen EX250-SEN1
- Produktkarten Sierra Monitor Corporation
- Informationsbroschüren
- oder Energieetiketten Sierra Monitor Corporation EX250-SEN1
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sierra Monitor Corporation EX250-SEN1.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sierra Monitor Corporation EX250-SEN1, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sierra Monitor Corporation EX250-SEN1. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sierra Monitor Corporation EX250-SEN1 ansehen.

Die komplette Bedienungsanleitung des Geräts Sierra Monitor Corporation EX250-SEN1, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sierra Monitor Corporation EX250-SEN1 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sierra Monitor Corporation EX250-SEN1 verständlich ist.

Eine gänzliche Bedienungsanleitung von Sierra Monitor Corporation sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sierra Monitor Corporation EX250-SEN1 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sierra Monitor Corporation EX250-SEN1 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sierra Monitor Corporation EX250-SEN1, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sierra Monitor Corporation EX250-SEN1 - die uns die ersten Schritte während der Nutzung von Sierra Monitor Corporation EX250-SEN1 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sierra Monitor Corporation EX250-SEN1 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sierra Monitor Corporation EX250-SEN1 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sierra Monitor Corporation EX250-SEN1?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sierra Monitor Corporation EX250-SEN1 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sierra Monitor Corporation EX250-SEN1 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.